Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “density maps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

CryoFold: Determining protein structures and data-guided ensembles from cryo-EM density maps

Cryoelectron microscopy requires molecular modeling for refinement of structures. Ensemble models arrive at low free-energy molecular structures, but are computationally expensive and limited to resolving only small proteins. Here, we introduce CryoFold, a pipeline of molecular dynamics simulations that determines ensembles of protein structures by integrating density data of varying sparsity at 3–5 Å resolution with sequence information and coarse-grained topological knowledge of the protein folds. We present six examples, folding proteins between 72 and 2,000 residues, including large membrane and multi-domain systems, and results from two Electron Microscopy Data Bank (EMDB) competitions. Driven by data from a single state, CryoFold discovers ensembles of common low-energy models together with rare low-probability structures that capture the equilibrium distribution of proteins constrained by the density maps. Many of these conformations are experimentally validated and functionally relevant. We arrive at a set of best practices for data-guided protein folding that are controlled using a Python graphical user interface (GUI).

59 BASIC BIOLOGICAL SCIENCES↗

MO-F-CAMPUS-J-04: Tissue Segmentation-Based MR Electron Density Mapping Method for MR-Only Radiation Treatment Planning of Brain

Purpose: Automatically derive electron density of tissues using MR images and generate a pseudo-CT for MR-only treatment planning of brain tumours. Methods: 20 stereotactic radiosurgery (SRS) patients’ T1-weighted MR images and CT images were retrospectively acquired. First, a semi-automated tissue segmentation algorithm was developed to differentiate tissues with similar MR intensities and large differences in electron densities. The method started with approximately 12 slices of manually contoured spatial regions containing sinuses and airways, then air, bone, brain, cerebrospinal fluid (CSF) and eyes were automatically segmented using edge detection and anatomical information including location, shape, tissue uniformity and relative intensity distribution. Next, soft tissues - muscle and fat were segmented based on their relative intensity histogram. Finally, intensities of voxels in each segmented tissue were mapped into their electron density range to generate pseudo-CT by linearly fitting their relative intensity histograms. Co-registered CT was used as a ground truth. The bone segmentations of pseudo-CT were compared with those of co-registered CT obtained by using a 300HU threshold. The average distances between voxels on external edges of the skull of pseudo-CT and CT in three axial, coronal and sagittal slices with the largest width of skull were calculated. The mean absolute electron density (in Hounsfield unit) difference of voxels in each segmented tissues was calculated. Results: The average of distances between voxels on external skull from pseudo-CT and CT were 0.6±1.1mm (mean±1SD). The mean absolute electron density differences for bone, brain, CSF, muscle and fat are 78±114 HU, and 21±8 HU, 14±29 HU, 57±37 HU, and 31±63 HU, respectively. Conclusion: The semi-automated MR electron density mapping technique was developed using T1-weighted MR images. The generated pseudo-CT is comparable to that of CT in terms of anatomical position of tissues and similarity of electron density assignment. This method can allow MR-only treatment planning.

60 APPLIED LIFE SCIENCES↗

Subgrain geometrically necessary dislocation density mapping in spalled Ta in three dimensions

Here, in this work, the intragranular distributions of the densities of geometrically necessary dislocations (GNDs) generated in a polycrystalline tantalum (Ta) sample loaded in shock compression to spall are investigated. The sample studied is a highly resolved three-dimensional (3D) map of the orientations, grain boundary morphology, and voids across a 0.276mm 3 (with sample dimensions of 688.5µm x 669µm x 600µm) region of the microstructure about the spall plane obtained by TriBeam tomography. We present a formulation for calculating the crystallographic screw and edge character GND densities at a material point within body centered cubic (BCC) crystals when provided any number of potential slip systems or modes. Combining the 3D characterization, GND formulation, and a sample containing ≈ 6000 grains, we sought statistically relevant correlations between GND density per grain with grain size, grain orientation, void formation, and proximity from the spall plane. We show that GND density per grain increases with decreasing distance from the spall plane. Most grains had heterogeneously distributed GND densities but were free of any detectable voids, at least within the ≈ 1.5µm resolution of the characterization technique. It is found that the GND density for most grains is insensitive to grain size and grain orientation. Only the fraction of grains with the highest GND densities tended to have a [001] parallel to shock-direction orientation. Intragranular 3D maps of GNDs reveals that grains that contain voids have high GND density concentrations in the intragranular region immediately surrounding the void. The local intragranular GND mapping also showed voids that are connected to grain boundaries preferred to grow into the grain with the larger size, regardless of orientation.

36 MATERIALS SCIENCE↗

TU-AB-BRA-03: Atlas-Based Algorithms with Local Registration-Goodness Weighting for MRI-Driven Electron Density Mapping

Purpose: To develop image-analysis algorithms to synthesize CT with accurate electron densities for MR-only radiotherapy of head & neck (H&N) and pelvis anatomies. Methods: CT and 3T-MRI (Philips, mDixon sequence) scans were randomly selected from a pool of H&N (n=11) and pelvis (n=12) anatomies to form an atlas. All MRIs were pre-processed to eliminate scanner and patient-induced intensity inhomogeneities and standardize their intensity histograms. CT and MRI for each patient were then co-registered to construct CT-MRI atlases. For more accurate CT-MR fusion, bone intensities in CT were suppressed to improve the similarity between CT and MRI. For a new patient, all CT-MRI atlases are deformed onto the new patients’ MRI initially. A newly-developed generalized registration error (GRE) metric was then calculated as a measure of local registration accuracy. The synthetic CT value at each point is a 1/GRE-weighted average of CTs from all CT-MR atlases. For evaluation, the mean absolute error (MAE) between the original and synthetic CT (generated in a leave-one-out scheme) was computed. The planning dose from the original and synthetic CT was also compared. Results: For H&N patients, MAE was 67±9, 114±22, and 116±9 HU over the entire-CT, air and bone regions, respectively. For pelvis anatomy, MAE was 47±5 and 146±14 for the entire and bone regions. In comparison with MIRADA medical, an FDA-approved registration tool, we found that our proposed registration strategy reduces MAE by ∼30% and ∼50% over the entire and bone regions, respectively. GRE-weighted strategy further lowers MAE by ∼15% to ∼40%. Our primary dose calculation also showed highly consistent results between the original and synthetic CT. Conclusion: We’ve developed a novel image-analysis technique to synthesize CT for H&N and pelvis anatomies. Our proposed image fusion strategy and GRE metric help generate more accurate synthetic CT using locally more similar atlases (Support: Philips Healthcare). The research is supported by Philips HealthCare.

60 APPLIED LIFE SCIENCES↗

Enhanced magnetic flux density mapping using coherent steady state equilibrium signal in MREIT

Measuring the z-component of magnetic flux density B = (B{sub x}, B{sub y}, B{sub z}) induced by transversally injected current, magnetic resonance electrical impedance tomography (MREIT) aims to visualize electrical property (current density and/or conductivity distribution) in a three-dimensional imaging object. For practical implementations of MREIT technique, it is critical to reduce injection of current pulse within safety requirements. With the goal of minimizing the noise level in measured B{sub z} data, we propose a new method to enhance the measure B{sub z} data using steady-state coherent gradient multi-echo (SSC-GME) MR pulse sequence combining with injection current nonlinear encoding (ICNE) method in MREIT, where the ICNE technique injects current during a readout gradient to maximize the signal intensity of phase signal including B{sub z}. The total phase offset in SSC-GME includes additional magnetic flux density due to the injected current, which is different from the phase signal for the conventional spoiled MR pulse sequence. We decompose the magnetization precession phase from the total phase offset including B{sub z} and optimize B{sub z} data using the steady-state equilibrium signal. Results from a real phantom experiment including different kinds of anomalies demonstrated that the proposed method enhanced B{sub z} comparing to a conventional spoiled pulse sequence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time and space resolved current density mapping in three dimensions using magnetic field probe array in a high voltage coaxial gap

We present an experimental analysis of the symmetry of current density in a coaxial geometry, diagnosed using a magnetic field probe array and calculations of the Fowler-Nordheim enhancement factor. Data were collected on the coaxial gap breakdown device (240 A, 25 kV, 150 ns, ~0.1 Hz), and data from experiments using 2 different gap sizes and different penetration depths are compared over runs comprising 50 shots for each case. The magnetic field probe array quantifies the distribution of current density at three axial locations, on either sides of a vacuum breakdown, and tracks the evolution with time and space. The results show asymmetries in current density, which can be influenced by changes in the gap size and the penetration depth (of the center electrode into the outer electrode). For smaller gap sizes (400 μm), symmetric current profiles were not observed, and the change in the penetration depth changes both the symmetric behavior of the current density and the enhancement factor. For larger gaps (900 μm), current densities were typically more uniform and less influenced by the penetration depth, which is reflected in the enhancement factor values. Furthermore it is possible that the change in inductance caused by the localization of current densities plays a role in the observed behavior.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive Machine Learning for Bragg Coherent Diffraction Imaging (BCDI) of 3D Electron Density Maps with Application to La 2-x Ba x CuO 4 (LBCO) High Temperature Superconductor Studies [PowerPoint]

Understanding mesoscale heterogeneity is important for evaluating fatigue and failure of structural materials and for manufacturing processes. Data-driven tools can facilitate in guiding effort investment (measurements and computations) at various stages of the materials development. Our 3D reconstruction approach is to find a set of coefficients which define a bounding surface of the electron density. Data for training the 3D CNN was generated by sampling coefficients from uniform distributions. Test vs. prediction values are shown for the 28 even-valued coefficients for 1000 test structures, with the best and worst performers highlighted. The adaptive part of this work utilized a model independent extremum seeking (ES). The predictions of the CNN were used as the starting point for the ES algorithm. The convergence of the ES algorithm for 3 different structures is illustrated, and the robustness of the adaptive ML approach was demonstrated on experimentally measured 3D crystal from high energy diffraction microscopy. Reconstruction of a non-uniform density volume with different levels of Poisson noise is also shown. Preliminary attempts at reconstructing measured La 2-x Ba x CuO 4 diffraction patterns have so far failed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hydrogen density mapping in biomolecular crystals through dynamic nuclear polarization

Many fundamental biological processes, including those in photosynthetic reaction centers and enzyme active sites, involve charge and energy transfer, bond cleavage, protonation and hydrogen bonding. Because H atoms play such central roles in these reactions, accurately determining their positions is essential. Yet, conventional X-ray crystallography primarily resolves the heavy atoms in biological structures and provides limited insight into hydrogen, even at atomic resolution. Neutron macromolecular crystallography (NMC) overcomes this limitation by offering exceptional sensitivity to hydrogen and deuterium. Here, we present a theoretical framework for the development of dynamic nuclear polarization NMC (DNP-NMC) techniques, which exploit the alignment of neutron and proton nuclear spins to enhance and tune the hydrogen signal contribution. The DNP-NMC approach advances the resolution of H atoms within biomolecular crystals, whether bound to protein residues or present in solvent. The method establishes key relationships for the coherent structure factor of polarized neutron scattering from hydrogenous matter. It theoretically achieves full accuracy in phase reconstruction and offers a path to improve neutron structure determination, achieving accuracies exceeding ≳80% by incorporating titration states. Using a variant of the hybrid input/output phase-retrieval algorithm, it allows recovery of the hydrogen density with ≳90% phase accuracy. In conclusion, we further discuss sources of experimental uncertainty for the upcoming DNP-enabled, quasi-Laue IMAGINE-X experiment at Oak Ridge National Laboratory's High Flux Isotope Reactor.

dynamic nuclear polarization↗

qFit-ligand Reveals Widespread Conformational Heterogeneity of Drug-Like Molecules in X-Ray Electron Density Maps

Here, proteins and ligands sample a conformational ensemble that governs molecular recognition, activity, and dissociation. In structure-based drug design, access to this conformational ensemble is critical to understand the balance between entropy and enthalpy in lead optimization. However, ligand conformational heterogeneity is currently severely underreported in crystal structures in the Protein Data Bank, owing in part to a lack of automated and unbiased procedures to model an ensemble of protein–ligand states into X-ray data. Here, we designed a computational method, qFit-ligand , to automatically resolve conformationally averaged ligand heterogeneity in crystal structures, and applied it to a large set of protein receptor–ligand complexes. In an analysis of the cancer related BRD4 domain, we found that up to 29% of protein crystal structures bound with drug-like molecules present evidence of unmodeled, averaged, relatively isoenergetic conformations in ligand–receptor interactions. In many retrospective cases, these alternate conformations were adventitiously exploited to guide compound design, resulting in improved potency or selectivity. Combining qFit-ligand with high-throughput screening or multitemperature crystallography could therefore augment the structure-based drug design toolbox.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Opportunities and challenges for assigning cofactors in cryo-EM density maps of chlorophyll-containing proteins

Abstract The accurate assignment of cofactors in cryo-electron microscopy maps is crucial in determining protein function. This is particularly true for chlorophylls (Chls), for which small structural differences lead to important functional differences. Recent cryo-electron microscopy structures of Chl-containing protein complexes exemplify the difficulties in distinguishing Chl b and Chl f from Chl a . We use these structures as examples to discuss general issues arising from local resolution differences, properties of electrostatic potential maps, and the chemical environment which must be considered to make accurate assignments. We offer suggestions for how to improve the reliability of such assignments.

59 BASIC BIOLOGICAL SCIENCES↗

Electrode Slurry Particle Density Mapping Using X-ray Radiography

The internal structure of a porous electrode strongly influences battery performance. Understanding the dynamics of electrode slurry drying could aid in engineering electrodes with desired properties. For instance, one might monitor the dynamic, spatially-varying thickness near the edge of a slurry coating, as it should lead to non-uniform thickness of the dried film. This work examines the dynamic behavior of drying slurry drops consisting of SiO x and carbon black particles in a solution of carboxymethylcellulose and deionized water, as an experimental model of drying behavior near the edge of a slurry coating. An X-ray radiography-based procedure is developed to calculate the evolving spatial distribution of active material particles from images of the drying slurry drops. To the authors’ knowledge, this study is the first to use radiography to investigate battery slurry drying, as well as the first to determine particle distributions from radiography images of drying suspensions. The dynamic results are consistent with tomography reconstructions of the static, fully-dried films. It is found that active material particles can rapidly become non-uniformly distributed within the drops. Heating can promote distribution uniformity, but seemingly must be applied very soon after slurry deposition. Higher slurry viscosity is found to strongly restrain particle redistribution.

25 ENERGY STORAGE↗

Application of transport-based metric for continuous interpolation between cryo-EM density maps

Cryogenic electron microscopy (cryo-EM) has become widely used for the past few years in structural biology, to collect single images of macromolecules "frozen in time". As this technique facilitates the identification of multiple conformational states adopted by the same molecule, a direct product of it is a set of 3D volumes, also called EM maps. To gain more insights on the possible mechanisms that govern transitions between different states, and hence the mode of action of a molecule, we recently introduced a bioinformatic tool that interpolates and generates morphing trajectories joining two given EM maps. This tool is based on recent advances made in optimal transport, that allow efficient evaluation of Wasserstein barycenters of 3D shapes. As the overall performance of the method depends on various key parameters, including the sensitivity of the regularization parameter, we performed various numerical experiments to demonstrate how MorphOT can be applied in different contexts and settings. Finally, we discuss current limitations and further potential connections between other optimal transport theories and the conformational heterogeneity problem inherent with cryo-EM data.

3D shapes↗