Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “default parameters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

TU-FG-209-04: Testing of Digital Image Receptors Using AAPM TG-150’s Draft Recommendations - Investigating the Impact of Different Processing Parameters

Purpose: To evaluate implementation of AAPM TG-150’s draft recommendations via a parameter study for testing the performance of digital image receptors. Methods: Flat field images were acquired from 9 calibrated digital image receptors associated with 9 new portable digital radiography systems (Carestream Health, Inc.) based on the draft recommendations and manufacturer-specified calibration conditions (set of 4 images at input detector air kerma ranging from 1 to 25 µGy). Effects of exposure response function (linearized and logarithmic), ‘Presentation Intent Type’ (‘For Processing’ and ‘For Presentation’), detector orientation with respect to the anode-cathode axis (4 orientations; 900 rotations per iteration), different ROI sizes (5×5–40×40 mm{sup 2}) and elimination of varying dimensions of image border (0 mm i.e., without boundary elimination to 150 mm) on signal, noise, signal-to-noise ratio (SNR) and the associated nonuniformities were evaluated. Images were analyzed in Matlab and quantities were compared using ANOVA. Results: Signal, noise and SNR values averaged over 9 systems with default parameter values in draft recommendations were 4837.2±139.4, 19.7±0.9 and 246.4±10.1 (mean ± standard deviation), respectively (at input detector air kerma: 12.5 µGy). Signal, noise and SNR showed characteristic dependency on exposure response function and on ‘Presentation Intent Type’. These values were not affected by ROI size and detector orientation, but analysis showed that eliminating the edge pixels along the boundary was required for the noise parameter (coefficient of variation range for noise: 72%–106% and 3%–4% without and with boundary elimination; respectively). Local and global nonuniformities showed a similar dependence on the need for boundary elimination. Interestingly, computed non-uniformities showed agreement with manufacturer-reported values except for noise non-uniformities in two units; artifacts were seen in images from these two units highlighting the importance of independent evaluations. Conclusion: The effect of different parameters on performance characterization of digital image receptors was evaluated based on TG-150’s draft recommendations.

60 APPLIED LIFE SCIENCES↗

Maxine Onsite: Estimating Dose from Chronic Atmospheric Radioactive Releases

Maxine Onsite: Developed to estimate dose to individuals who are working onsite but are not site employees. Follows the methodologies discussed in US NRC Regulatory Guides 1.109 and 1.111 to determine dose from a chronic atmospheric release. Determines the dose given relative air concentrations and deposition concentrations as input. We look at four locations onsite that may be accessed by members of the public. To show compliance with the EPA and DOE public dose limit of 10 mrem/yr, determining who is a member of the public or a worker onsite is necessary. SRS has defined a member of the public for NESHAPS and DOE O 458.1. Maxine Onsite runs on Microsoft Windows Operating System through a Microsoft Excel spreadsheet. Input from the user includes parameters that are variable such as air concentrations, and fixed, such as distance to the receptor and elemental iodine fraction. Maxine Onsite was developed from Maxine which is a program meant to calculate dose to the MEI via three pathways, external, inhalation, and ingestion. Maxine Onsite is meant for looking at the exposure through the external and inhalation pathways only, no local food production onsite. The ways that Maxine Onsite is used to calculate the dose to the MEI includes the following: - Determining the respective air concentration values at each location using distances from the release stack; - Breathing rates for the MEI; - Determining the amount of time the MEI is outside; - Determining the plume travel time. The following relative air and ground deposition values for proper execution of the spreadsheet come from MAXDOSE-SR and are needed to accurately determine the dose to the MEI: relative air concentration, relative air concentration decayed by 2.26 days, relative air concentration decayed and depleted for 8 days, and relative deposition. Test cases were designed, developed, and executed to determine the accuracy of Maxine Onsite, which were verified additionally through hand calculations. Several changes were made for testing, including varying air concentrations, distances, breathing rates, and shielding factors. Each test case was then verified through hand calculations to assure the accuracy of the calculated doses. The results from the test cases, as well as the default parameters, can be used for benchmarking Maxine Onsite in the future. Maxine Onsite performs as expected and produces correct and accurate results at each of the different locations onsite (TRL, B-Area Barracks, SRELCC, and Gunsite 51) for varying test cases. The input required by the user is minimal and includes the results of the dose to the MEI on the first page for ease of access. Future plans for Maxine Onsite include adding in the ingestion pathway and adding in atmospheric dispersion estimates to the spreadsheet.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coupling localized Noah-MP-Crop model with the WRF model improved dynamic crop growth simulation across Northeast China

Croplands play a critical role in regulating the energy and moisture exchanges between the land surface and atmosphere. However, the interactions between cropland and climate are usually poorly represented due to a lack of detailed representation in crop types and field management. Here, we coupled the Noah-MP-Crop model with the state-of-the-art Weather Research and Forecasting (WRF) model to explore and evaluate the crop growth dynamics in response to climate variations across Northeast China. The default parameters of the crop model were not exactly suitable for the agricultural ecosystems in Northeast China. The detailed cropland distribution, and crop phenology parameters including growing degree days (GDD) and planting (harvesting) date were first created using multi-source remote sensing products and reanalysis data, and was then successfully used to simulate the growth and yield for corn and soybean and associated energy exchanges. We also optimized and calibrated other crop parameters using the time-series of the Moderate Resolution Imaging Spectroradiometer (MODIS) land surface products. The modified crop model substantially improved the simulation of crop growth, plant physiology, and biomass accumulation for both corn and soybean. Coupling the localized dynamic crop model into the WRF led to considerable decreases in the simulated mean-absolute-errors (MAEs) and biases of the leaf area index, evapotranspiration, and gross primary production compared with the MODIS observed values. Compared with the statistical yield from each province, the modified crop model underestimated the corn yield from 11.1% to 48.6%, whereas overestimated the soybean yield from 16.5% to 162.6%.

54 ENVIRONMENTAL SCIENCES↗

ELSI: A unified software interface for Kohn–Sham electronic structure solvers

Solving the electronic structure from a generalized or standard eigenproblem is often the bottleneck in large scale calculations based on Kohn-Sham density-functional theory. This problem must be addressed by essentially all current electronic structure codes, based on similar matrix expressions, and by high-performance computation. We here present a unified software interface, ELSI, to access different strategies that address the Kohn-Sham eigenvalue problem. Currently supported algorithms include the dense generalized eigensolver library ELPA, the orbital minimization method implemented in libOMM, and the pole expansion and selected inversion (PEXSI) approach with lower computational complexity for semilocal density functionals. The ELSI interface aims to simplify the implementation and optimal use of the different strategies, by offering (a) a unified software framework designed for the electronic structure solvers in Kohn-Sham density-functional theory; (b) reasonable default parameters for a chosen solver; (c) automatic conversion between input and internal working matrix formats, and in the future (d) recommendation of the optimal solver depending on the specific problem. As a result, comparative benchmarks are shown for system sizes up to 11,520 atoms (172,800 basis functions) on distributed memory supercomputing architectures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

54 Fe neutron elastic and inelastic scattering differential cross sections from 2–6 MeV

Measurements of neutron elastic and inelastic scattering cross sections from 54 Fe were performed for nine incident neutron energies between 2 and 6 MeV. Measured differential scattering cross sections are compared to those from previous measurements and the ENDF, JENDL, and JEFF data evaluations. TALYS calculations were performed and modifications of the default parameters are found to better describe the experimental cross sections. A spherical optical model treatment is generally adequate to describe the cross sections in this energy region; however, in 54 Fe the direct coupling is found to increase suddenly above 4 MeV and requires an increase in the DWBA deformation parameter by approximately 25%. Furthermore, this has little effect on the elastic scattering differential cross sections but makes a significant improvement in both the strength and shape of the inelastic scattering angular distribution, which are found to be very sensitive to the size and extent of the surface absorption region.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An evaluation of in vivo models for toxicokinetics of hexavalent chromium in the stomach

Hexavalent chromium (Cr6) is a drinking water contaminant that has been detected in most of the water systems throughout the United States. In 2-year drinking water bioassays, the National Toxicology Program (NTP) found clear evidence of carcinogenic activity in male and female rats and mice. Because reduction of Cr6 to trivalent chromium (Cr3) is an important detoxifying step in the gastrointestinal (GI) tract prior to systemic absorption, models have been developed to estimate the extent of reduction in humans and animals. The objective of this work was to use a revised model of ex vivo Cr6 reduction kinetics in gastric juice to analyze the potential reduction kinetics under in vivo conditions for mice, rats and humans. A published physiologically-based pharmacokinetic (PBPK) model was adapted to incorporate the new reduction model. This paper focuses on the toxicokinetics of Cr6 in the stomach compartment, where most of the extracellular Cr6 reduction is believed to occur in humans. Within the range of doses administered by the NTP bioassays, neither the original nor revised models predict saturation of stomach reducing capacity to occur in vivo if applying default parameters. However, both models still indicate that mice exhibit the lowest extent of reduction in the stomach, meaning that a higher percentage of the Cr6 dose may escape stomach reduction in that species. Similarly, both models predict that humans exhibit the highest extent of reduction at low doses. - Highlights: • We outline a new in vivo model for hexavalent chromium reduction in the stomach. • We examine in vivo reduction for mice, rats, and humans under varying conditions. • Species differences in toxicokinetics may explain susceptibility. • We show that a simplified stomach reduction model is adequate for extrapolation. • Internal dose uncertainties still exist.

60 APPLIED LIFE SCIENCES↗

Macromolecular structure determination using X-rays, neutrons and electrons: recent developments in Phenix

Diffraction (X-ray, neutron and electron) and electron cryo-microscopy are powerful methods to determine three-dimensional macromolecular structures, which are required to understand biological processes and to develop new therapeutics against diseases. The overall structure-solution workflow is similar for these techniques, but nuances exist because the properties of the reduced experimental data are different. Software tools for structure determination should therefore be tailored for each method. Phenix is a comprehensive software package for macromolecular structure determination that handles data from any of these techniques. Tasks performed with Phenix include data-quality assessment, map improvement, model building, the validation/rebuilding/refinement cycle and deposition. Each tool caters to the type of experimental data. The design of Phenix emphasizes the automation of procedures, where possible, to minimize repetitive and time-consuming manual tasks, while default parameters are chosen to encourage best practice. A graphical user interface provides access to many command-line features of Phenix and streamlines the transition between programs, project tracking and re-running of previous tasks.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement of 139 La(p,x) cross sections from 35–60 MeV by stacked-target activation

A stacked-target of natural lanthanum foils (99.9119% 139 La) was irradiated using a 60 MeV proton beam at the LBNL 88-Inch Cyclotron. 139 La(p,x) cross sections are reported between 35–60 MeV for nine product radionuclides. The primary motivation for this measurement was the need to quantify the production of 134 Ce. As a positron-emitting analogue of the promising medical radionuclide 225 Ac, 134 Ce is desirable for in vivo applications of bio-distribution assays for this emerging radio-pharmaceutical. Finally, the results of this measurement were compared to the nuclear model codes TALYS, EMPIRE and ALICE (using default parameters), which showed significant deviation from the measured values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Excitation functions and isomeric cross-section ratios of (d,xn) reactions on 86 Sr

Excitation functions of the 86 Sr(d,n) 87m,87g Y, 86 Sr(d,2n) 86m,86g Y and 86 Sr(d,3n) 85m,85g Y reactions on enriched 86 Sr target were measured by the activation technique up to deuteron energies of 49 MeV. The isomeric cross-section ratios as a function of projectile energy were deduced from the measured data for 87m Y, 87g Y(cum), 86m Y, 86g Y(cum), 85m Y and 85g Y pairs for the same energy range. All measurements are reported for the first time. The experimental data were compared with the data from the TENDL library which is based on TALYS calculation with default parameters. No satisfactory agreement was observed. Nuclear model calculations were then performed using the codes TALYS and EMPIRE with some parameter adjustments, and compared with the experimental data. The quality of the agreement between experimental data and model calculations was numerically quantified. In general, the data as well as the isomeric cross-section ratios are partially reproduced by the model calculations, provided the input model parameters are properly chosen and the level structure of the product nucleus is thoughtfully considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TEMPEST (Thermo-Electric Model for Powering Energy Storage Technologies)

NREL's TEMPEST model combines electrical and thermal modeling for residential-scale battery systems. The model and default parameters are based off of two common commercial residential batteries. Key inputs to the model include house load, temperature of the battery location, and the solar profile. The key output of the TEMPEST model is the battery profile and internal battery temperature. If internal battery temperature exceeds limits, a derating will occur and this will be reflected in the battery profile. In addition to thermal modeling, the TEMPEST model uses realistic operating principals that are common in today's residential batteries. Mainly, the TEMPEST model incorporates "modes" of operation that constrain battery setpoint based on house load, solar output, and state of charge. The TEMPEST model can be used to analyze the effect of battery temperature, deratings, and mode setpoints on utility network loading and customer bills.

Blonsky, Michael↗

Verification of EPA's ''Preliminary Remediation Goals for radionuclides'' (PRG) electronic calculator

The U.S. Environmental Protection Agency (EPA) requested an external, independent verification study of their updated “Preliminary Remediation Goals for Radionuclides” (PRG) electronic calculator. The calculator provides PRGs for radionuclides that are used as a screening tool at Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) and Resource Conservation and Recovery Act (RCRA) sites. These risk-based PRGs establish concentration limits under specific exposure scenarios. The purpose of this verification study is to determine that the calculator has no inherit numerical problems with obtaining solutions as well as to ensure that the equations are programmed correctly. There are 167 equations used in the calculator. To verify the calculator, all equations for each of seven receptor types (resident, construction worker, outdoor and indoor worker, recreator, farmer, and composite worker) were hand calculated using the default parameters. The same four radionuclides (Am-241, Co-60, H-3, and Pu-238) were used for each calculation for consistency throughout.

54 ENVIRONMENTAL SCIENCES↗

An update to the computation of the Goudsmit-Saunderson distribution in MCNP® version 6.2

To demonstrate how the number of terms used to compute the Goudsmit- Saunderson distribution impacts results, we study a thin foil problem where the outgoing angular distribution is observed for 20-MeV electrons. The foil thickness is roughly 1.5 times the default substep size for a 20-MeV electron in gold ( 2.8e -3 cm). Therefore, for the default substep size, electrons are guaranteed to undergo at least one collision before encountering a boundary (at which point an approximation is applied). In theory, one can improve the accuracy of the MCNP6.2 electron transport method by reducing the substep size. However, one must assume that the underlying data are valid. We show that when a user reduces the substep size, the angular distribution observed is different than expected, the primary reason being that the underlying data were not computed using a sufficient number of terms. We also show that the distribution is recovered when the number of terms is increased from hundreds to thousands. Here, we showed that stabilizing the underlying angular deflection distributions used in transport improves simulation results, particularly when default parameters are adjusted such that the substep size is reduced. Stabilization is achieved by adding more terms when computing the Goudsmit-Sanderson distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PNNL Measurement Results for the 2018 FlatTop Criticality Nuclear Accident Dosimetry Exercise at the Nevada National Security Site (IER-253)

The Pacific Northwest National Laboratory (PNNL) participated in the FlatTop exercise IER-253 at the National Nuclear Security Site (NNSS) during the week of May 21, 2018. This report summarizes the measurements of the personal nuclear accident dosimeters (PNAD). Additionally, portable survey instrument readings and measurements of the simulated biological samples are included. The FlatTop exercise (IER-253) tested only PNADs and did not include fixed nuclear accident dosimeters (FNAD). Previous PNAD results obtained in 2016 at the Godiva-IV exercise IER-148 were summarized in PNNL Measurement Results for the 2016 Criticality Accident Dosimetry Exercise at the Nevada National Security Site IER-148 (PNNL-26497). The results clearly indicated that the previous dose conversions were a historical legacy of the Hanford Site and corresponded closer to kerma dose (or first collision dose, and not to Hp(10) dose). The technical basis for PNAD dose was based on the Godiva-IV exercise and documented in A New Dose Calculation Methodology for New PNAD and FNAD Designs at PNNL (PNNL-27023). The configuration of the PNAD was described in these two documents. The FlatTop exercise was the first time PNNL tested this new dose calculation methodology. Results were generally favorable with some results conservatively over reported that fell above the performance criteria. The reported gamma dose results fell non-conservatively low because only the default parameters obtained from the Godiva-IV exercise were used, and because the OSL gamma dosimeter has an energy dependency. The results from the simulated biological samples were also favorable, and in several cases conservatively over reported.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterizing Seasonal Variation of the Atmospheric Mixing Layer Height Using Machine Learning Approaches

As machine learning becomes more integrated into atmospheric science, XGBoost has gained popularity for its ability to assess the relative contributions of influencing factors in the atmospheric boundary layer height. To examine how these factors vary across seasons, a seasonal analysis is necessary. However, dividing data by season reduces the sample size, which can affect result reliability and complicate factor comparisons. To address these challenges, this study replaces default parameters with grid search optimization and incorporates cross-validation to mitigate dataset limitations. Using XGBoost with four years of data from the atmospheric radiation measurement (ARM) (Southern Great Plains (SGP) C1 site, cross-validation stabilizes correlation coefficient fluctuations from 0.3 to within 0.1. With optimized parameters, the R value can reach 0.81. Analysis of the C1 site reveals that the relative importance of different factors changes across seasons. Lower tropospheric stability (LTS, ~0.53) is the dominant factor at C1 throughout the year. However, during DJF, latent heat flux (LHF, 0.44) surpasses LTS (0.22). In SON, LTS (0.58) becomes more influential than LHF (0.18). Further comparisons among the four long-term SGP sites (C1, E32, E37, and E39) show seasonal variations in relative importance. Notably, during JJA, the differences in the relative importance of the three factors across all sites are lower than in other seasons. This suggests that boundary layer development in the summer is not dominated by a single factor, reflecting a more intricate process likely influenced by seasonal conditions such as enhanced convective activity, higher temperatures, and humidity, which collectively contribute to a balanced distribution of parameter impacts. Furthermore, the relative importance of LTS gradually increases from morning to noon, indicating that LTS becomes more significant as the boundary layer approaches its maximum height. Consequently, the LTS in the early morning in autumn exhibits greater relative importance compared to other seasons. This reflects a faster development of the mixing layer height (MLH) in autumn, suggesting that it is easier to retrieve the MLH from the previous day during this period. The findings enhance understanding of boundary layer evolution and contribute to improved boundary layer parameterization.

54 ENVIRONMENTAL SCIENCES↗

35 GeV e-p collisions, SM type, LEPTO/ARIADNE generator: gev35ep_lepto6ard_dis1q2

Electron-proton collisions. LEPTO 6.5 with ARIADNE 4.12. Q2>1 GeV2. MSTW2008lo68cl PDF (LHAPDF= 21000). Other default parameters are E(scattered)>1 GeV and W2>5 GeV2. Collision energy: E(p)=60 GeV and E(e-)=5 GeV. These energies are designed for the JLab EIC proposal. The samples were requested by J.Repond for ANL LDRD studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

35 GeV e-p collisions, SM type, LEPTO/PYTHIA generator: gev35ep_lepto6_dis1q2

Electron-proton collisions. LEPTO 6.5 with PYTHIA 5.7 for PS and hadronization. Q2>1 GeV2. CT10W PDF (LHAPDF= 10900). Other default parameters are E(scattered)>1 GeV and W2>5 GeV2. Collision energy: E(p)=60 GeV and E(e-)=5 GeV. These energies are designed for the JLab EIC proposal. The samples were requested by J.Repond for ANL LDRD studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Water balance model (WBM) v.1.0.0: a scalable gridded global hydrologic model with water-tracking functionality

Abstract. This paper describes the University of New Hampshire Water Balance Model, WBM, a process-based gridded global hydrologic model that simulates the land surface components of the global water cycle and includes water extraction for use in agriculture and domestic sectors. The WBM was first published in 1989; here, we describe the first fully open-source WBM version (v.1.0.0). Earlier descriptions of WBM methods provide the foundation for the most recent model version that is detailed here. We present an overview of the model functionality, utility, and evaluation of simulated global river discharge and irrigation water use. This new version adds a novel suite of water source tracking modules that enable the analysis of flow-path histories on water supply. A key feature of WBM v.1.0.0 is the ability to identify the partitioning of sources for each stock or flux within the model. Three different categories of tracking are available: (1) primary inputs of water to the surface of the terrestrial hydrologic cycle (liquid precipitation, snowmelt, glacier melt, and unsustainable groundwater); (2) water that has been extracted for human use and returned to the terrestrial hydrologic system; and (3) runoff originating from user-defined spatial land units. Such component tracking provides a more fully transparent model in that users can identify the underlying mechanisms generating the simulated behavior. We find that WBM v.1.0.0 simulates global river discharge and irrigation water withdrawals well, even with default parameter settings, and for the first time, we are able to show how the simulation arrives at these fluxes by using the novel tracking functions.

54 ENVIRONMENTAL SCIENCES↗

RADIATION DOSE ASSESSMENT FOR THE BIOTA OF TERRESTRIAL ECOSYSTEMS IN THE SHORELINE ZONE OF THE CHERNOBYL NUCLEAR POWER PLANT COOLING POND

Radiation exposure of the biota in the shoreline area of the Chernobyl Nuclear Power Plant Cooling Pond was assessed to evaluate radiological consequences from the decommissioning of the Cooling Pond. The article addresses studies of radioactive contamination of the terrestrial faunal complex and radionuclide concentration ratios in bodies of small birds, small mammals, amphibians, and reptiles living in the area. The data were used to calculate doses to biota using the ERICA Tool software. Doses from {sup 90}Sr and {sup 137}Cs were calculated using the default parameters of the ERICA Tool and were shown to be consistent with biota doses calculated from the field data. However, the ERICA dose calculations for plutonium isotopes were much higher (2-5 times for small mammals and 10-14 times for birds) than the doses calculated using the experimental data. Currently, the total doses for the terrestrial biota do not exceed maximum recommended levels. However, if the Cooling Pond is allowed to drawdown naturally and the contaminants of the bottom sediments are exposed and enter the biological cycle, the calculated doses to biota may exceed the maximum recommended values. The study is important in establishing the current exposure conditions such that a baseline exists from which changes can be documented following the lowering of the reservoir water. Additionally, the study provided useful radioecological data on biota concentration ratios for some species that are poorly represented in the literature.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗