A 20-kW DC Oak Ridge Converter with Integrated AC & DC Sources for Grid Services and Energy Storage Systems

This paper proposes a wireless power transfer (WPT) platform with integrated energy conversion that has the capability for 1) recharging the energy storage systems (ESSs) from the grid systems, including renewable energy sources such as wind, solar, etc., 2) off grid systems recharging the ESSs from dc grid systems, 3) grid recharging of electric vehicles (EVs), and 4) off grid recharging of EVs from ESSs. The unique aspect of the method is the use of multi-interface power electronic converter for the grid and ESSs and EVs that can support a range of applications with ac / dc and dc / dc energy conversion ability in a single converter system. The key enabling technology to achieve these functionalities is Oak Ridge Converter (ORC) with polyphase coupler coil system both developed at ORNL. This new technology enables higher power density WPT systems while allowing the coils to interface from ac grid at 60 Hz frequency or dc source directly merging with 85 kHz operating frequency of switching component. The experimental results of the proposed system are presented for 20 kW output power with the system overall efficiency around 95.4% from dc source and 93% overall efficiency from ac grid achieving 9-10% current total harmonic distortion (THD) and 0.98-0.99 power factor (PF).

Asa, Erdem↗

Inverted Geometry Ceramic Insulators in High Voltage DC Electron Guns for Accelerators

A direct current (dc) high voltage photo-emission electron gun operating at 130 kV is utilized at the Jefferson Lab (JLab) Continuous Electron Beam Accelerator Facility to generate spin-polarized electrons for nuclear physics experiments. Over the past decade, JLab has tested and implemented inverted-geometry ceramic insulators in photoguns, connecting the cathode electrode in vacuum to the high voltage power supply using commercial high voltage cables. This contribution reports on tests performed up to 375 kV dc, implementation of inverted insulators in a 300 kV dc photogun generating magnetized electron beams, and describes plans to develop a reliable insulator-cable connector for applying 500 kV dc to a future polarized beam photogun operating reliably and without field emission at 350 kV.

Hernandez-Garcia, C.↗

Applying Machine Learning to the Classification of DC-DC Converters. NA-22 Final Report

Tools are now available that enable measurement electromagnetic radiation (EMR) from active electronics in an item. This radiation may be intended WIFI or cellular network links, for example or unintended such as the switching noise generated by DC-to-DC converters. It would be extremely valuable to have the capability to discriminate between the low-voltage DC-to-DC converters or other digital noise prevalent in most modern electronics, versus the high-voltage DC-to-DC converters used in utility firesets. Previous work performed under a Sandia Laboratory Directed Research and Development (LDRD) project on Charge State Detection using a deep neural network has been continued in this effort. A state-of-the-art supervised machine learning algorithm has not only been extended to discriminate between low and high voltage converters but has been validated in determining a converters make and model.

42 ENGINEERING↗

Four-phase interleaved TCM DC-DC buck converter with matrix inductor in battery charging application

In this paper, a 1-kW DC-DC buck converter with a four-phase interleaved matrix inductor is proposed for battery charging applications. It is well-known that the DC bias on the inductor will cause high core loss as it changes the B–H characteristic. Typically, the transient conduction mode employed in high voltage applications for zero-voltageswitching of devices would cause higher inductor current ripple. The conventional approach to reduce the effect of DC bias and inductor current ripple is employing multi-phases. However, the cost and size of the converter will increase significantly. This paper proposes the matrix inductor which has a small volume and reduces the effect of the DC bias by flux sharing and flux cancellation at the same time, results in low inductor core loss. With the interleaved operations the output current ripple can be lower which is suitable for battery charging application. Besides, the comparison of the synchronous and interleaved operation is presented. A 1-kW prototype is built and the experimental results show that the peak efficiency is 99.1% and 99.2% for synchronous and interleaved control, respectively. Additionally, the output current ripple of the interleaved operation is reduced by 85% in comparison with the synchronous operation.

14 SOLAR ENERGY↗

Implementing the DC Mode in Cosmological Simulations with Supercomoving Variables

As emphasized by previous studies, proper treatment of the density fluctuation on the fundamental scale of a cosmological simulation volume - the 'DC mode' - is critical for accurate modeling of spatial correlations on scales ~> 10% of simulation box size. We provide further illustration of the effects of the DC mode on the abundance of halos in small boxes and show that it is straightforward to incorporate this mode in cosmological codes that use the 'supercomoving' variables. The equations governing evolution of dark matter and baryons recast with these variables are particularly simple and include the expansion factor, and hence the effect of the DC mode, explicitly only in the Poisson equation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiterminal High-Voltage dc Systems with Series-Parallel Valve Group-Based High-Voltage dc Substations

To transfer large amount of power over long distances, multiterminal direct current (MTdc) system based on bipole high-voltage direct current (HVdc) technology is a viable option. However, such system results in large dc transmission loss. The same can be reduced by increasing the dc voltage level. This paper introduces a new MTdc system architecture comprising of series (for increasing dc voltage level) and parallel (for increasing dc current capability) connected HVdc converters. The new architecture is compared with the bipole MTdc architecture in terms of equipment needed and dc transmission loss. The control modifications needed for the MTdc system are identified and the performance of the developed control is verified through electromagnetic transient (EMT) simulations.

Jaldanki, Sreenivasa↗

DC to DC electrical transformer

An electrical transformer system using helical electrodes applied to a plasma. Systems and methods transform DC voltages and currents to different DC voltages and currents. Instead of using wires and iron cores similar to known transformers, the present DC to DC transformer system exploits plasma, helical electrodes, an axial magnetic field and radial magnetic field coils, with a control system to specify a radial magnetic field at the edge of a specified magnitude. A DC input voltage is applied, and an output is taken from electrodes at opposite the ends of the central apparatus. The system and apparatus contains a radial magnetic field embedded in the helical electrodes; the secondary current is taken from either solid or split (slotted) electrodes. Methods are disclosed for changing the output voltage and current relative to the input values. The system can function as either a stepup or a stepdown transformer.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analytical Expression for DC Link Capacitor Current in a Cascaded H-Bridge Multi-Level Active Front-End Converter

Medium-voltage grid-tied systems often use a cascaded H-bridge multi-level active front-end. In this converter, dc link bus capacitors play an important role in stabilizing the converter and enabling both active and reactive power injections. The present work provides analytical expressions for the capacitor current, which are essential for optimizing system design (especially capacitor size vs. lifetime). Then, the expression is incorporated into the grid connected bidirectional power system model. Consequently, this work contributes to the guiding principles to choose accurate dc link capacitor ratings against grid-side power delivery requirements. The analytical results have been validated with detailed simulations and hardware results.

cascaded H-bridge, carrier-based PWM, dc-link capa↗

Decentralized Interleaving of Paralleled Dc-Dc Buck Converters

We present a decentralized control strategy that yields switch interleaving among parallel-connected dc-dc buck converters. The proposed method is based on the digital implementation of the dynamics of a nonlinear oscillator circuit as the controller. Each controller is fully decentralized, i.e., it only requires the locally measured output current to synthesize the pulse width modulation (PWM) carrier waveform and no communication between different controllers is needed. By virtue of the intrinsic electrical coupling between converters, the nonlinear oscillator-based controllers converge to an interleaved state with uniform phase-spacing across PWM carriers. To the knowledge of the authors, this work presents the first fully decentralized strategy for switch interleaving in paralleled dc-dc buck converters.

14 SOLAR ENERGY↗

Integration of Storage in the DC Link of a Full Converter-Based Distributed Wind Turbine

Energy storage is known to support the dispatchability of variable renewable resources. In this paper, we model a battery energy storage system (BESS) integrated with the DC link of a Type IV full converter-based wind turbine and the necessary controls to achieve efficient dispatch. To support the validation of control methodologies, we build a detailed model of a Type IV research wind turbine at the National Renewable Energy Laboratory (NREL), the Controls Advanced Research Turbine (CART 3), and we integrated a lithium-ion BESS model in grid-following mode into the model. The simulation results illustrate the sizing and control of the DC link-integrated BESS for a given variable wind resource and varying dispatch strategies (i.e., under constant, uncertain, and ramping wind scenarios). The integrated storage can smooth variabilities in distributed wind output, hedge against uncertainties, provide the ramping capability, as well as support stability under voltage and frequency transients. All of these have been illustrated in MATLAB/Simulink.

DC-link voltage↗

Electrified Automotive Powertrain Architecture Using Composite DC–DC Converters

In a hybrid or electric vehicle powertrain, a boost dc-dc converter enables reduction of the size of the electric machine and optimization of the battery system. Design of the powertrain boost converter is challenging because the converter must be rated at high peak power, while efficiency at medium-to-light load is critical for the vehicle system performance. By addressing only some of the loss mechanisms, previously proposed efficiency improvement approaches offer limited improvements in size, cost, and efficiency tradeoffs. This article shows how all dominant loss mechanisms in automotive powertrain applications can be mitigated using a new boost composite converter approach. In the composite dc-dc architecture, the loss mechanisms associated with indirect power conversion are addressed explicitly, resulting in fundamental efficiency improvements over wide ranges of operating conditions. Several composite converter topologies are presented and compared to state-of-the-art boost converter technologies. It is found that the selected boost composite converter results in a decrease in the total loss by a factor of 2-4 for typical drive cycles. Furthermore, the total system capacitor power rating and energy rating are substantially reduced, which implies potentials for significant reductions in system size and cost.

25 ENERGY STORAGE↗

A Reduced-Part, Triple-Voltage DC-DC Converter for EV/HEV Power Management

Electrical power systems in future hybrid and fuel cell vehicles may consist of three voltage nets: 14 V, 42 V, and high voltage (>200 V) buses. A soft-switched, bidirectional dc-dc converter that uses only four switches was proposed for interconnecting the three nets. This paper presents a reduced-part dc-dc converter, which decreases the converter cost while retaining all the favorable features of the original topology. Experimental data are included to verify a simple power flow control scheme.

30 DIRECT ENERGY CONVERSION↗

Decentralized Interleaving of Paralleled Dc-Dc Buck Converters: Preprint

We present a decentralized control strategy that yields switch interleaving among parallel connected dc-dc buck converters without communication. The proposed method is based on the digital implementation of the dynamics of a nonlinear oscillator circuit as the controller. Each controller is fully decentralized, i.e., it only requires the locally measured output current to synthesize the pulse width modulation (PWM) carrier waveform. By virtue of the intrinsic electrical coupling between converters, the nonlinear oscillator-based controllers converge to an interleaved state with uniform phase-spacing across PWM carriers. To the knowledge of the authors, this work represents the first fully decentralized strategy for switch interleaving of paralleled dc-dc buck converters.

14 SOLAR ENERGY↗

Electric Field Characteristics of an Arc-Induction-Type DC Circuit Breaker Combined with a Magnet for Stability in the DC Power Grid

For stability in the direct current (DC) power grid, it is very important to limit the current of the fault section and to protect the system in the fault condition. That is the core technology of the DC power grid. This paper suggests characteristics and a limited range of the fault current for the new model as the significant protecting technology in the DC power grid. Such new model is the arc-induction-type DC circuit breaker (CB) combined with a magnet. The magnetic arc-induction-type direct-current circuit breaker (DCCB) consists of a neodymium magnet, an induction needle, and electrical contacts. During fault operation, the arc occurring between the contacts is induced to the induction needle. To increase the induction effect, Lorentz force is applied to blow the arc. A magnet was applied to reduce the initial fault current and to induce magnetic flux. The simulation data were analyzed using the Maxwell 3D software program. The electric field included the electric force and the electric charge. Therefore, it could analyze the arc as the electric field. The simulation was performed based on the preceding study on induction needle. As a result of the simulation, it was confirmed that the electric field value of the induction needle increased when the DCCB was combined with a magnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transient pulse‐based impedance characterisation of DC‐link capacitor for EV systems

In this study, a method for impedance characterisation of DC‐link capacitors based on transient pulse analysis is proposed. The fundamentals of the concept are presented and design considerations are discussed. The functionality of the proposed approach is supported by SPICE simulation with two different commercial capacitors from different manufacturers and validated with experimental results. Experimental results for equivalent series resistance, equivalent series inductance (ESL) and capacitance estimation are presented for commercial DC‐link capacitors and compared with component analyser results. The simulation and experimental results show that the proposed method is a promising candidate for capacitance and ESL estimation of capacitors in EV traction systems.

Gurpinar, Emre↗

Architectures and Control of Submodule Integrated DC-DC Converters for Photovoltaic Applications

This paper describes photovoltaic (PV) module architectures with parallel-connected submodule-integrated dc-dc converters (subMICs) that improve efficiency of energy capture in the presence of partial shading or other mismatch conditions. The subMICs are bidirectional isolated dc-dc converters capable of injecting or subtracting currents to balance the module substring voltages. When no mismatches are present, the subMICs are simply shut down, resulting in zero insertion losses. It is shown that the objective of minimum subMIC power processing can be solved as a linear programming problem. A simple close-to-optimal distributed control approach is presented that allows autonomous subMIC control without the need for a central controller or any communication among the subMICs. Furthermore, the proposed control approach is well suited for an isolated-port architecture, which yields additional practical advantages including reduced subMIC power and voltage ratings. The architectures and the control approach are validated by simulations and experimental results using three bidirectional flyback subMICs attached to a standard 180-W, 72-cell PV module, yielding greater than 98% module-level power processing efficiency for a mismatch less than 25%.

Olalla, C↗

Dynamic Resistance of YBCO-Coated Conductors in Applied AC Fields with DC Transport Currents and DC Background Fields

In order to predict heat loads in future saturable core fault-current-limiting devices due to ac fringing fields, dynamic resistance in YBCO-coated conductors was measured at 77 K in peak ac fields up to 25 mT at 60 Hz and in dc fields up to 1 T. With the sample orientation set such that the conductor face was either parallel or perpendicular to the ac and dc applied fields, the dynamic resistance was measured at different fractions of the critical current to determine the relationship between the dc transport current and the applied fields. With respect to field orientation, the dynamic resistance for ac fields that were perpendicular to the conductor face was significantly higher than when the ac fields were parallel to the conductor face. It was also observed that the dynamic resistance: (1) increased with increasing fraction of the dc transport current to the critical current, (2) was proportional to the inverse of the critical current, and (3) demonstrated a linear dependence with the applied ac field once a threshold field was exceeded. This functional behavior was consistent with a critical state model for the dynamic resistance, but discrepancies in absolute value of the dynamic resistance suggested that further theoretical development is needed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preventing Voltage Divergence in Series-Stacked Bidirectional Battery Energy Storage DC-DC Converter under Asymmetrical Operating Conditions

DC stacked topologies have gained popularity for interfacing individual photovoltaic panels to a high-voltage DC bus. A similar approach can be used to interface individual battery packs to the same DC bus, which allows active balancing of battery substrings and the use of lower voltage switches. Any imbalance in battery current, however, can cause the converter output voltages to diverge. This paper describes the source of voltage divergence and demonstrates a solution that allows seamless stacking of multiple battery packs to be interfaced to a high voltage DC bus. To prevent the voltage divergence phenomenon and allow asymmetrical battery charging for efficient battery state of charge management, the PI-based decentralized voltage control enabling both capacitor voltage sharing and asymmetrical capacitor voltage control is proposed. The effectiveness of the decentralized voltage control strategy is demonstrated through controller hardware-in-the-loop test results.

Kim, Namwon↗