Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “daylighting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Integrated Dynamic Facade Control with an Agent-based Architecture for Commercial Buildings

Dynamic façades have significant technical potential to minimize heating, cooling, and lighting energy use and peak electric demand in the perimeter zone of commercial buildings, but the performance of these systems is reliant on being able to balance complex trade-offs between solar control, daylight admission, comfort, and view over the life of the installation. As the context for controllable energy-efficiency technologies grows more complex with the increased use of intermittent renewable energy resources on the grid, it has become increasingly important to look ahead towards more advanced approaches to integrated systems control in order to achieve optimum life-cycle performance at a lower cost. This study examines the feasibility of a model predictive control system for low-cost autonomous dynamic façades. A system architecture designed around lightweight, simple agents is proposed. The architecture accommodates whole building and grid level demands through its modular, hierarchical approach. Automatically-generated models for computing window heat gains, daylight illuminance, and discomfort glare are described. The open source Modelica and JModelica software tools were used to determine the optimum state of control given inputs of window heat gains and lighting loads for a 24-hour optimization horizon. Penalty functions for glare and view/ daylight quality were implemented as constraints. The control system was tested on a low-power controller (1.4 GHz single core with 2 GB of RAM) to evaluate feasibility. The target platform is a low-cost ($35/unit) embedded controller with 1.2 GHz dual-core cpu and 1 GB of RAM. Configuration and commissioning of the curtainwall unit was designed to be largely plug and play with minimal inputs required by the manufacturer through a web-based user interface. An example application was used to demonstrate optimal control of a three-zone electrochromic window for a south-facing zone. The overall approach was deemed to be promising. Further engineering is required to enable scalable, turnkey solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Validation of Integrated Lighting Systems Retrofit Performance and Energy Savings

Light-emitting diodes (LED) fixtures and lamps have emerged as leading technologies for general illumination and are a well-established energy efficiency retrofit measure in commercial buildings (from around 2% of installed fixtures and lamps in 2013 to 28% by 2020). Retrofit approaches that integrate elements, such as networked controls, daylight dimming, and advanced shade technologies lag in comparison. Integrated retrofits have been shown to increase savings over single end-use retrofits, but are perceived as higher complexity and risk. More validation of integrated lighting system performance is needed. This study presents results from laboratory testing of three packages combining fixtures, networked controls, task tuning, and daylight dimming, advanced shades, and lighting layout changes. We characterize performance in perimeter open-office zones, finding energy savings from 20% for daylight dimming and automated shades (no LED retrofit) to over 70% for LED retrofits with advanced controls and shades or lighting layout changes. We present some implementation details, including lessons learned from installation and commissioning in the laboratory setting. We also discuss cost-benefit analysis approaches for the types of packages presented, including the need to quantify and incorporate energy and non-energy benefits for advanced shades packages, which enhance occupant comfort but add significant cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

lumicap v0.1

Automated HDR luminance imaging system designed for daylighting research and building science. It controls a fisheye-lens camera to capture time-lapse bracket sequences, merges them into calibrated HDR images, and runs a full post-processing pipeline — all unattended. Features: - Scheduled LDR bracket capture via gphoto2 - HDR merging with vignetting, ND filter, and fisheye projection corrections - Illuminance and luminance meter integration (Konica Minolta T-10A, LS-100/150) - Daylight glare probability (DGP) and solar position computation - Automated false-color rendering, JPEG thumbnails, and daily time-lapse video - CSV data logging per timestep Uses: - Long-term monitoring of daylight conditions in buildings - Glare analysis for occupant comfort research - Solar irradiance and sky luminance studies Advantages: - End-to-end automation — capture, calibration, analysis, and archiving run without manual intervention - Built on the proven Radiance toolchain, ensuring photometrically accurate HDR output - Hardware-agnostic meter support via serial auto-detection - Lightweight — no GUI overhead, deployable on a headless Raspberry Pi or similar embedded system

Wang, Taoning [Lawrence Berkeley National Laborato↗

Developing Flexible, Networked Lighting Control Systems That Reliably Save Energy in California Buildings

An important strategy to meet California's ambitious energy efficiency goals is to use innovative wireless communications, embedded sensors, data analytics and controls to significantly reduce lighting energy use in commercial buildings. This project developed a suite of networked lighting solutions to further this goal. The technologies include a platform for low-cost sensing, distributed intelligence and communications, the “PermaMote,” which is a self-powered sensor and controller for lighting applications. The project team also developed a task ambient daylighting system that integrates sensors with data-driven daylighting control using an open communication interface, called the “Readings-At-Desk” (RAD) system. To address the problem of building occupants being confused about how to operate traditional lighting control systems, the research team created content that could be the basis for a user interface standard for lighting controls. Finally, to address the difficulty of ensuring that advanced lighting control systems actually deliver their promised energy savings, the project team developed a new method for evaluating and specifying lighting systems’ performance. The research team validated these technologies in the laboratory, showing significant lighting energy savings, up to 73% for the PermaMote sensor system from occupancy control and daylight dimming features, compared to the same light source (LED replacement lamps) operated via simple on/off scheduling. The project team also developed a proposed standard lighting data model and user interface elements, which were contributed to the ANSI Lighting Systems Committee (C137) for standardization. Existing data models are incomplete and inconsistent, whereas the lighting-specific data model developed here is clear and comprehensive, to serve as a starting point for creating common, universally agreed upon semantic definitions of key lighting parameters, to promote interoperability. For the task on verifiable performance of lighting systems, the project team developed a more effective metric for capturing the actual energy impact of a lighting system over time — the energy usage intensity (kWh/ft2/year). Three commercial lighting systems were tested in FLEXLAB® using this new metric, and the tests show a wide range in the accuracy of the self-reported energy-use metric, from 0.5% to 28% error compared to direct measurement of lighting energy using dedicated submeters. Overall, the project team estimates that these advanced technologies can reduce California office lighting energy use by 20% (above and beyond normal advanced lighting controls mandated by Title 24), resulting in about 1,600 GWh/year in savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy and Comfort Impacts of High Performance Facades in Office Buildings

Building facades have a major effect on energy use, occupant comfort, and well-being. Yet adoption of high-performance facades is often slowed by limited data and unclear cost benefits. To address this gap, Oak Ridge National Laboratory, in collaboration with the Facade Tectonics Institute, conducted whole-building energy simulations to evaluate fenestration technologies for small and medium office buildings across three weather locations: hot (Tampa, Florida, weather zone 2A), mixed (New York, New York, weather zone 4A), and cold (Rochester, Minnesota, weather zone 6A). The simulations included parametric variations in window-to-wall ratio (30%–70%), U-values (0.1–1 Btu/h∙ft 2 ∙°F), solar heat gain coefficients (0.2–0.8), and solar control strategies and devices (e.g., interior shades and switchable glazing). Performance metrics included annual cooling, heating, and total heating, ventilation and air-conditioning (HVAC) energy use intensity, as well as nonenergy factors such as useful daylight illuminance, glare frequency, and thermal comfort during typical office hours (8 a.m.–6 p.m.). Results indicate that cooling energy consumption is most sensitive to solar heat gain coefficient (SHGC) in hot weather, whereas heating energy consumption is strongly influenced by U-value in cold weather. Total HVAC reflects these trade-offs, showing up to 60% difference for a window in total HVAC energy use intensity between different combinations of U-value and SHGC. Daylight dimming generally reduces cooling loads but can increase heating demands in colder locations. Interior solar shades improve useful daylight and reduce discomfort glare, whereas switchable glazing delivers the largest cooling reductions in hot weather but may increase heating loads in winter by limiting passive solar gains. Thermal comfort improves with lower window-to-wall ratios and lower SHGC in hot locations and with lower U-values in cold locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determining critical points to control electric lighting to meet circadian lighting requirements and minimize energy use

Designing electric lighting systems to meet circadian lighting requirements may raise light levels and consequently energy use compared to existing practices. To reduce energy use, electric lighting can be controlled to be dimmed or turned off when sufficient daylight levels are available in space. This requires input from one or a few critical measurement points. However, it is unclear how critical points can be determined to ensure that all occupants receive the needed light levels while reducing electric lighting energy. This paper discusses three approaches for selecting critical points and utilizes annual daylight simulations modified to account for sky spectra, and coupled with spectral electric lighting simulations. Among the three evaluated approaches, the use of continuous daylight autonomy (modified to use EML measured at eye positions) is helpful for estimating electric lighting energy for dimmable electric lighting systems, and for identifying energy-saving strategies.

Abboushi, Belal K.↗

The Impact of Operated Window Shading on Visual Comfort, Non-Visual Health, and Energy Demand from Electric Lighting

This paper introduces a simulation-based workflow to assess annual circadian lighting performance, glare risk and energy demand for an array of seated view positions under operated shading and electric lighting conditions. This workflow uses a combination of 9-band and 81-band simulations to represent daylight and electric lighting respectively. Annual daylight-driven calculations rely on a python-based code provided in the LARK simulation engine which was used to run 180-degree high dynamic range (HDR) renderings with 9-bands of spectral resolution. The results reveal the impact of shading systems on equivalent melanopic lux (EML) and daylight glare probability (DGP) over time and the energy demand (kWh) from electric lighting systems to supplement eye-level recommendations from the WELL v2 Building Standard.

Rockcastle, Siobhan↗

Field validation of data-driven BSDF and peak extraction models for light-scattering fabric shades

Shading and daylighting systems affect cooling, heating, and lighting energy use by modulating solar radiation through the building façade. Characterizing shading systems holistically and accurately helps designers and engineers evaluate shading systems to achieve energy and non-energy performance goals. These complex fenestration systems can be modeled using Bidirectional Scattering Distribution Functions (BSDF), which map incident radiation to hemispherical distributions of outgoing radiation. Data-driven, tabulated BSDFs are derived from interpolated goniophotometer measured data, then sampled during the raytracing calculation. A peak extraction (PE) algorithm was developed to circumvent limits in BSDF angular resolution, where the specular peak is extracted during simulation by evaluating the BSDF in the through direction and surrounding region. The objective of this study was to validate this measurement and modeling workflow using field monitored data from a full scale testbed with eleven installed fabrics of different weaves, openness factors, and colors and assess the accuracy of the workflow under different adaptation and contrast conditions. Test conditions were limited to clear sky conditions with the sun in the field of view. Results showed that, for tensor tree datasets, vertical illuminance, solar luminance (2.5° apex), and daylight glare probability (DGP) were predicted to within a mean bias error (MBE) error of -456 lx (-12.3%), -3.46e5 (-38.4%), and -0.042 (-7.8%) when full PE occurred. With a binary classification of glare/ no glare, DGP was predicted accurately with a true positive rate of 0.98 and true negative rate of 1.0 using tensor tree data and less accurately with Klems BSDF data, particularly for cases of no glare. The workflow may be of insufficient accuracy to distinguish borderline performance between fabrics using the four-point glare scale, particularly under low adaptation, high contrast daylit conditions. Errors were due to reductions in peak shape and intensity across the BSDF interpolation and data reduction workflow. Future work is needed to better preserve measurement fidelity during interpolation and sampling, which in turn will improve PE performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multidisciplinary concurrent optimization framework for multi-phase building design process

Modern day building design projects require multidisciplinary expertise from architects and engineers across various phases of the design (conceptual, preliminary, and detailed) and construction processes. The Architecture Engineering and Construction (AEC) community has recently shifted gears toward leveraging design optimization techniques to make well-informed decisions in the design of buildings. However, most of the building design optimization efforts are either multidisciplinary optimization confined to just a specific design phase (conceptual/preliminary/detailed) or single disciplinary optimization (structural/thermal/daylighting/energy) spanning across multiple phases. Complexity in changing the optimization setup as the design progresses through subsequent phases, interoperability issues between modeling and physics-based analysis tools used at later stages, and the lack of an appropriate level of design detail to get meaningful results from these sophisticated analysis tools are few challenges that limit multi-phase multidisciplinary design optimization (MDO) in the AEC field. Here this paper proposes a computational building design platform leveraging concurrent engineering techniques such as interactive problem structuring, simulation-based optimization using meta models for energy and daylighting (machine learning based) and tradespace visualization. The proposed multi-phase concurrent MDO framework is demonstrated by using it to design and optimize a sample office building for energy and daylighting objectives across multiple phases. Furthermore, limitations of the proposed framework and future avenues of research are listed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Performance Integrated Window and Façade Solutions for California

The researchers developed a new generation of high-performance façade systems and supporting design and management tools to support industry in meeting California’s greenhouse gas reduction targets, reduce energy consumption, and enable an adaptable response to minimize real-time demands on the electricity grid. The project resulted in five outcomes: (1) The research team developed an R-5, 1-inch thick, triplepane, insulating glass unit with a novel low-conductance aluminum frame. This technology can help significantly reduce residential cooling and heating loads, particularly during the evening. (2) The team developed a prototype of a windowintegrated local ventilation and energy recovery device that provides clean, dry fresh air through the façade with minimal energy requirements. (3) A daylight-redirecting louver system was prototyped to redirect sunlight 15–40 feet from the window. Simulations estimated that lighting energy use could be reduced by 35–54 percent without glare. (4) A control system incorporating physics-based equations and a mathematical solver was prototyped and field tested to demonstrate feasibility. Simulations estimated that total electricity costs could be reduced by 9-28 percent on sunny summer days through adaptive control of operable shading and daylighting components and the thermostat compared to state-of-the-art automatic façade controls in commercial building perimeter zones. (5) Supporting models and tools needed by industry for technology R&D and market transformation activities were validated. Attaining California’s clean energy goals require making a fundamental shift from today’s ad-hoc assemblages of static components to turnkey, intelligent, responsive, integrated building façade systems. These systems offered significant reductions in energy use, peak demand, and operating cost in California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The effect of lighting environment on task performance in buildings – A review

The effects of indoor environmental conditions on human health, satisfaction, and performance have been the focal point of research for decades. This paper reviews and summarizes the impact of lighting environment on task performance, specifically for the built environment audience. Existing studies included a variety of performance tests on cognitive performance and perception, visual acuity and reaction, memory, reasoning, and labor productivity. Illuminance, luminance ratio and correlated color temperature were found to affect performance in different ways, reflecting the impact of experimental techniques, conditions, performance evaluation methods used and data analysis methods. These were reviewed and categorized, with discussion on limitations related to sample size, modeling approach, carryover effects and other factors affecting individual differences in performance, with recommendations for future improvement. Although no universal conclusions can be made, in general, task performance seems to improve with higher illuminances, contrast ratios in the range of 7–11:1 (while always making sure that glare will not occur in the space) and higher correlated color temperature, while spectral tuning in the red or blue wavelengths has also shown positive effects. To obtain more generic evidence, future studies should be more consistent in terms of experimental procedures and overall light conditions, and also consider the effects of vertical illuminance, daylight provision/control, and outside views on task performance. Finally, studying performance with multi-factorial designs in a human-centered optimized manner (such as deploying variable lighting scenarios optimized for various tasks) can lead to deeper understanding of lighting effects on task performance, and ultimately to improved lighting design and operation in buildings overall.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Acclimation to high and low diurnal light is flexible in Chlamydomonas reinhardtii

Chlamydomonas acclimates to repeated low (LL) or high light (HL) days by changing the abundance of photosynthetic complexes and the ultrastructure of its thylakoid membranes. These phenotypes persist through the night phases, suggesting a readiness for the daylight environment that is routinely experienced despite the intervening dark periods [S. Dupuis et al., Plant Cell 37, koaf086 (2025), 10.1093/plcell/koaf086]. Here, we investigate how prior acclimation impacts algal fitness upon a change in daylight intensity and how quickly Chlamydomonas can reprogram its photoprotective strategy in a diurnal context. We performed a systems analysis of synchronized populations acclimated to diurnal LL when subjected to HL days and of populations acclimated to diurnal HL when subjected to LL days. In the latter case, diurnal photoacclimation decreased fitness during the first day at a new light intensity: HL-acclimated cells barely increased in size over the first LL period, and they failed to complete a cell cycle. However, although LL-acclimated cells showed severe photodamage after 6 h of HL, they recovered chloroplast form and function later that afternoon and successfully divided at nightfall. These cells rapidly altered their thylakoid membrane ultrastructure, increased their photoprotective quenching capacity, and decreased their inventory of photosystem and antenna proteins by the end of the first HL day. Transcriptomic and proteomic analyses revealed rapid induction of thousands of genes, including those encoding proteases, chaperones, and other proteins involved in the chloroplast unfolded protein response. These results show that the alga is highly flexible and competent to rapidly acclimate to changes in diurnal light intensity.

Diel↗

Relative Contributions of sc-DER, mel-DER, Color Rendition, Chromaticity, and Illuminance to Spatial Brightness Perception

An experiment was conducted to examine spectrally based factors that contribute to the visual perception of interior environments, with a focus on brightness perception. Thirty-two participants evaluated 60 different lighting scenes in a mock office. The lighting spectral power distributions varied systematically in illuminance, chromaticity (CCT and Duv), s cone opic daylight efficacy ratio (sc-DER), melanopic daylight efficacy ratio (mel-DER), and color rendition (R f , R g , and R cs,h1 ). At the operationalized levels of these variables, illuminance had the largest effect on brightness perception. Notably, the second largest effect was due to changes in red chroma (R cs,h1 ). The effect of sc-DER was also statistically significant but was a tertiary effect. The effects of mel-DER, CCT, and Duv were not statistically significant. This large effect of red chroma is consistent with the existing understanding that changes in color perception are often perceived when illuminance changes. In conclusion, with appropriate changes in color rendition and other factors held constant, spatial brightness perception was preserved through a decrease from 500 lux to 250 lux.

42 ENGINEERING↗

Simulating Buildings While the Design is Still in the Architect's Imagination

Very early in the design process, prior to drawing a single line, architects get information from their client or prospective client trying to understand the nature and requirements of the building that needs to be designed. The design of the building is completely fluid, as the architect considers many options in their imagination. The overall massing of the building, the general shape and form, are being considered during this early step. Even for a simple box-shaped building, the aspect ratio between the east-west and the north-south dimensions of the building can greatly impact energy consumption due to daylighting availability. The prevailing winds and building orientation can impact natural ventilation. The locations of high and low population density spaces can also impact energy use. Deciding the floor area per office workstation or the size of the auditorium will impact energy use. Does making a building two stories instead of one reduce energy impacts by reducing roof area or does the additional volume for stairs and elevators result in more energy use. Since certain types of spaces require more windows for occupants than others, the locations of those spaces will determine how much glazing each building orientation has impacting daylighting as well as heating and cooling energy. The project was an attempted first step toward creating a system tailored toward architects for this very early stage in the design process to help them understand the energy impacts of design options. The approach was not to be based on drawing the building, and instead, the main inputs would have been the size of each type of space in the building. This report describes information gathered during the development that might be of use to others developing similar software as well as some of the software that was developed during the project. Phase II funding to continue this work was not pursued due to intellectual property issues discovered during the development of the commercialization plan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Analysis of PNM's Renewable Reserve Requirements to Meet New Mexico's Decarbonization Goals

Over the next three years, the Public Service Company of New Mexico (PNM) plans to increase utility-scale solar photovoltaic (PV) capacity from today’s roughly 330MW to about 1600MW. This massive increase in variable generation—from about 15% to 75% of peak load—will require changes in how PNM operates their system. We characterize the 5 and 30-minute solar and wind forecast errors that the system is likely to experience in order to determine the level of reserves needed to counteract such events. Our focus in this study is on negative forecast error (in other words, shortfalls relative to forecast) – whereas excess variable generation can be curtailed if needed, a shortfall must be compensated for to avoid loss of load. Calculating forecast error requires the use of the same forecasting methods that PNM uses or a reasonable approximation thereof. For wind, we use a persistence forecast on actual 5-minute 2019 wind output data (scaled up to reflect the amount of wind capacity planned for 2025). For solar, we use a formula incorporating the clear sky index (CSI) for the forecast. As the solar on the grid now is a small fraction of what is planned for 2025, we generated 5-minute solar data using 2019 weather inputs. We find that to handle 99.9% of the 5-minute negative forecast errors, a maximum of 275MW of variable generation reserve during daylight hours, and a maximum of 75MW during non-daylight hours, should be sufficient. Note that this variable generation reserve is an additional reserve category that specifies reserves over and above what are currently carried for contingency reserve. This would require a significant increase in reserve relative to what PNM currently carries or can call upon from other utilities per reserve sharing agreements. This variable generation reserve specification may overestimate the actual level needed to deal with PNM’s planned variable generation in 2025. The forecasting methodologies used in this study likely underperform PNM’s forecasting – and better forecasting allows for less reserve. To obtain more precise estimates, it is necessary to consider load and use the same forecasting inputs and methods used by PNM.

14 SOLAR ENERGY↗

The Impact of Circadian Lighting Design Strategies on Lighting and Cooling Energy of an Office Space

A DOE-funded study of the potential electrical and thermal energy impacts of using daylight and electric light to meet existing recommendations for human health and well-being, conducted by Pacific Northwest National Laboratory (PNNL) in collaboration with researchers from Lawrence Berkeley National Laboratory, the University of Washington, and the University of Oregon. New software tools for modeling the spectral characteristics of light, like Adaptive Lighting for Alertness (ALFA), were leveraged to conduct annual daylighting, electric lighting, heating, and cooling simulations for office applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A method and tool to determine the colorimetric and photobiological properties of light transmitted through glass and other optical materials

Here we describe a framework and provides a computational tool to characterize the color quality and biological potential of light that is transmitted through glass and other optical materials. The IES TM-30 framework and Excel computation tool were adapted to evaluate color quality, with measures from CIE S 026, UL 24480, and the WELL Building Standard v2 added to evaluate biological potential. The user selects a pre-transmittance spectral power distribution (SPD), such as for a CIE D-Series Illuminant, Planckian radiation, electric lamp, or measurement of daylight at a building site. The tool allows a user to populate a database with spectral data for glazing or other optical materials, comprising spectral transmission and the spectral reflectance of both sides. The user creates a unit with one, two, or three panes of glazing or other optical materials, and the tool calculates the composite spectral transmittance accounting for reflections between materials. The tool computes the transmitted SPD, then determines colorimetric and photobiological outputs using the transmitted SPD as the test source. Glass, window, and skylight manufacturers can employ the tool to optimize glazing spectral transmission to achieve intentional colorimetric and photobiological performance with transmitted light. Electric lighting manufacturers, designers, and researchers can use the tool to evaluate the impact of glazing units and other optical materials on the color quality and biological potential of transmitted light.

36 MATERIALS SCIENCE↗

An evaluation of the demand response potential of integrated dynamic window and HVAC systems

Demand response (DR) increases the flexibility and reliability of the electricity grid as use of intermittent renewable energy sources increases. HVAC and envelope DR measures present the largest aggregate energy and peak demand savings potential of all commercial building end uses because their net demand savings occur during critical peak demand periods. Controllable envelope measures include switchable electrochromic windows, operable window attachments such as outdoor louvers, roller shades, and awnings, as well as other innovative facade technologies that can modulate both solar heat gain and daylight admission over a broad solar-optical range. This study evaluated the technical potential of DR-enabled dynamic windows to reduce critical peak demand for a prototypical medium office building situated in all 16 U.S. climates. Model predictive control (MPC) algorithms were designed to minimize electricity cost in daylit perimeter office zones through control of an electrochromic window with and without HVAC thermostat setpoint control. Conventional and time-of-use rates were used to shape the degree of DR. Median annual peak demand savings with window and thermostat control across all climate zones were 24.3 kW (4.4 W/m 2 ) per building or 15.9 W/m 2 for non-north perimeter zones. Resource adequacy at the whole building level was estimated to be 13.1 to 43.4 $/kW per year over the 30-year life of the installation. Co-benefits were increased energy efficiency, and reduced electricity cost and emissions. Visual and thermal comfort requirements were met at all times. Dynamic facades controlled by MPC have substantial technical potential for DR across all U.S. climates and warrant serious consideration for inclusion in DR portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗