Engineering PapersSearch

SEARCH · Engineering Papers

Results for “data logger”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Veggie Hardware Validation Test Preliminary Results and Lessons Learned

The Veggie hardware validation test, VEG-01, was conducted on the International Space Station during Expeditions 39 and 40 from May through June of 2014. The Veggie hardware and the VEG-01 experiment payload were launched to station aboard the SpaceX-3 resupply mission in April, 2014. Veggie was installed in an Expedite-the-Processing-of-Experiments-to-Space-Station (ExPRESS) rack in the Columbus module, and the VEG-01 validation test was initiated. Veggie installation was successful, and power was supplied to the unit. The hardware was programmed and the root mat reservoir and plant pillows were installed without issue. As expected, a small amount of growth media was observed in the sealed bags which enclosed the plant pillows when they were destowed. Astronaut Steve Swanson used the wet/dry vacuum to clean up the escaped particles. Water insertion or priming the first plant pillow was unsuccessful as an issue prevented water movement through the quick disconnect. All subsequent pillows were successfully primed, and the initial pillow was replaced with a backup pillow and successfully primed. Six pillows were primed, but only five pillows had plants which germinated. After about a week and a half it was observed that plants were not growing well and that pillow wicks were dry. This indicated that the reservoir was not supplying sufficient water to the pillows via wicking, and so the team reverted to an operational fix which added water directly to the plant pillows. Direct watering of the pillows led to a recovery in several of the stressed plants; a couple of which did not recover. An important lesson learned involved Veggie's bellows. The bellows tended to float and interfere with operations when opened, so Steve secured them to the baseplate during plant tending operations. Due to the perceived intensity of the LED lights, the crew found it challenging to both work under the lights and read crew procedures on their computer. Although the lights are not a safety hazard, for visual comfort crewmembers were advised to wear sunglasses when working with the plants and then they can lift glasses to read procedures. Steve Swanson had already trail-blazed this procedure when he initiated VEG-01. The temperature and humidity data logger was relocated mid-experiment to provide measurements on both sides of the unit. Images of the plants were downlinked weekly, and videos of installation and harvest were recorded. This imaging frequency was not sufficient to monitor and respond to changes in plant growth. Plants, samples, and data loggers will be returned on SpaceX-4, scheduled to return the fall of 2014. Lessons learned will be translated into hardware and operational modifications for future Veggie payloads.

International Space Station

Description and evaluation of the Acoustic Profiling of Ocean Currents (APOC) system used on R. V. Oceanus cruise 96 on 11-22 May 1981

The underway current profiling system which consists of a microprocessor controlled data logger that collects and formats data from a four beam Ametek-Straza 300 kHz acoustic Doppler current profiler, heading from the ship's gyrocompass, and navigation information from a Loran-C receiver and a satellite navigation unit is discussed. Data are recorded on magnetic tape and real time is calculated. Time averaging is required to remove effects of ship motion. An intercomparison is made with a moored vector measuring current meter (VMCM). The mean difference in hourly averaged APOC and VMCM currents over the four hour intercomparison is a few mm s minus including: two Gulf Stream crossings, a warm core ring survey, and shallow water in a frontal zone to the east of Nantucket Shoals.

Joyce, T. M.

Long term measurement network for FIFE

The objectives were: to obtain selected instruments which were not standard equipment on the Portable Automated Mesometeorological (PAM) and Data Control Platform (DCP) stations; to assist in incorporation of these instruments onto the PAM and DCP stations; to help provide routine maintenance of the instruments; to conduct periodic instrument calibrations; and to repair or replace malfunctioning instruments when possible. All of the objectives were or will be met soon. All instruments and the necessary instrument stands were purchased or made and were available for inclusion on the PAM and DCP stations before the beginning of the IFC-1. Due to problems beyond control, the DCP stations experienced considerable difficulty in becoming operational. To fill some of the gaps caused by the DCP problems, Campbell CR21-X data loggers were installed and the data collected on cassette tapes. Periodic checks of all instruments were made, to maintain data quality, to make necessary adjustments in certain instruments, to replace malfunctioning instruments, and to provide instrument calibration. All instruments will be calibrated before the beginning of the 1988 growing season as soon as the weather permits access to all stations and provides conditions that are not too harsh to work in for extended periods of time.

Blad, Blaine L.

Application of a dedicated micro-processor for automatic data acquisition of load strain and acoustic-emission data

This paper describes an automatic system for acquisition, logging and analysis of stress, strain and acoustic emission data. The complete system is a combination of several standard items of equipment and a newly developed intelligent data logger which has the capability to send data directly to a large scale computer for reduction and plotting. The data logging and all interfacing with peripheral equipment are accomplished using digital electronics. The heart of the system is a four-bit microprocessor and digital cassette tape unit. The system, which is controlled by instructions from a cathode ray tube terminal, has the capability to transmit data from the cassette unit to a large computer via a time sharing option. Typical results are presented for acoustic emission count rate and total count curves superimposed on stress-strain diagrams for boron/epoxy advanced composites.

Wilson, G. H.

Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: METSAT Phase Locked Oscillator Assembly, P/N 1334360-1, S/N's F03 and F04

Two Flight Model AMSU-A Phase Locked Oscillators (P/N 1348360-1, S/Ns F03 and F04) have been tested per AES Test Procedure AE-26758. The tests included vibration testing, thermal cycle testing, AM/FM Noise testing, and full functional testing. EMI/REO 2 Testing was not performed. (See test data for S/N F01). Both AMSU-A Phase Locked Oscillators satisfactorily passed all performance requirements of the AE-26633 Product specification. During thermal cycling of PLO serial number F03, the oven and data logger momentarily lost power, including a loss of data. The unit did not experience any thermal stress. TAR 003134 describes the corrective action. Prior to testing PLO serial number FO4, power was applied to the unit. (+15v,-15v) the unit did not display the proper phase lock. Upon test equipment check out a connector was found to be defective. TAR 003133 describes the corrective action. After completion of testing of PLO serial number F04 was installed into Receiver Assembly F02. Upon testing F02 Receiver Assembly the unit was found not to phase lock at ambient temperature. Removal of PLO Assembly F04 was required. R2 was the real issue. Solithane was secondary. Troubleshooting revealed excessive solithane on inner PLL Assembly cover inhibiting optimum grounding. Also, R2 was reselected which increased the lock range from -30 C to +60 C. TAR 002737 describes the corrective action.

Pines, D.

FSA field test

The 12 continental remote sites were decommissioned. Testing was consolidated into a five-site network consisting of the four Southern California sites and a new Florida site. 16 kW of new state-of-the-art modules were deployed at the five sites. Testing of the old modules continued at the Goldstone site but as a low-priority item. Array testing of modules is considered. Additional new testing capabilities were added. A battery-powered array data logger is discussed. A final set of failure and degradation data was obtained from the modules.

Jaffe, P.

A microprocessor controlled pressure scanning system

A microprocessor-based controller and data logger for pressure scanning systems is described. The microcomputer positions and manages data from as many as four 48-port electro-mechanical pressure scanners. The maximum scanning rate is 80 pressure measurements per second (20 ports per second on each of four scanners). The system features on-line calibration, position-directed data storage, and once-per-scan display in engineering units of data from a selected port. The system is designed to be interfaced to a facility computer through a shared memory. System hardware and software are described. Factors affecting measurement error in this type of system are also discussed.

Anderson, R. C.

A microprocessor controlled pressure scanning system

A microprocessor-based controller and data logger for pressure scanning systems is described. The microcomputer positions and manages data from as many as four 48-port electro-mechanical pressure scanners. The maximum scanning rate is 80 pressure measurements per second (20 ports per second on each of four scanners). The system features on-line calibration, position-directed data storage, and once-per-scan display in engineering units of data from a selected port. The system is designed to be interfaced to a facility computer through a shared memory. System hardware and software are described. Factors affecting measurement error in this type of system are also discussed.

Anderson, R. C.

BOREAS RSS-17 Stem, Soil, and Air Temperature Data

The BOREAS RSS-17 team collected several data sets in support of its research in monitoring and analyzing environmental and phenological states using radar data. This data set consists of tree bole and soil temperature measurements from various BOREAS flux tower sites. Temperatures were measured with thermistors implanted in the hydroconductive tissue of the trunks of several trees at each site and at various depths in the soil. Data were stored on a data logger at intervals of either 1 or 2 hours. The majority of the data were acquired between early 1994 and early 1995. The primary product of this data set is the diurnal stem temperature measurements acquired for selected trees at five BOREAS tower sites. The data are provided in tabular ASCII format. The data files are available on a CD-ROM (see document number 20010000884) or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

Zimmerman, Reiner

Exposure of Plant Seeds to the Space Environment Outside the International Space Station

Crop seeds may prove to be a vital component of future long-term spaceflight missions, and the impacts of extended exposure on seed degradation is not well understood. The MISSE-Seed project was designed to investigate the effects of space exposure on seed quality and storage. The project also served as a test of biological materials aboard the Materials International Space Station Experiment (MISSE) platform, and evaluated the capability of a newly designed passive sample containment vessel for the provision of acceptable storage conditions for seed and other biological samples to be preserved upon exposure to the space environment outside the ISS. MISSE-Seed was launched to the ISS on NG-15 in July of 2021 and returned to Earth aboard SpX-24 after approximately 8 months of exposure to the space environment. The specimens consisted of eleven seed varieties (Lettuce, Scarlet Frills, Amara, Garnet Giant, Pac Choi, Radish, Mizuna, Tomato, Cauliflower, Pepper, and Arabidopsis). Data-loggers and thermoluminescent dosimeters (TLDs) were included in each container to record environmental data. Temperature profiles and radiation/UV exposure data were also provided by Aegis Aerospace, the MISSE Implementation Partner. Hardware and experimental design, environmental profiles, and post-flight germination and growth results will be presented.

Alexander D Meyers

BOREAS TE-6 1994 Soil and Air Temperatures in the NSA

The BOREAS TE-6 team collected several data sets to examine the influence of vegetation, climate, and their interactions on the major carbon fluxes for boreal forest species. This data set contains measurements of the air temperature at a single height and soil temperature at several depths in the NSA from 25-May to 08-Oct- 1994. Chromel-Constantan thermocouple wires run by a miniprogrammable data logger (Model 21X, Campbell Scientific, Inc., Logan, UT) provided direct measurements of temperature. The data are stored in tabular ASCII files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distrobuted Activity Archive Center (DAAC).

Hall, Forrest G.

Exposure of Plant Seeds to the Space Environment outside the International Space Station

If crop seeds are to be stored on space vehicles for long-duration missions, the effects of the space environment on the seeds must be understood for developing mitigation strategies to prevent seed degradation. The MISSE-Seed project was designed to investigate the effects of space exposure on seed quality and storage. The project also tested the Materials International Space Station Experiment (MISSE) platform for exposing biological samples to the space environment and evaluated the capability of a newly designed passive sample containment vessel for the provision of acceptable storage conditions for seeds, or other biological samples, to be preserved upon exposure to the space environment outside the ISS. The experiment was launched to the ISS on NG-15and returned to Earth aboard SpX-24. The specimens consisted of eleven seed varieties (Lettuce, Scarlet Frills, Amara, Garnet Giant, Pac Choi, Radish, Mizuna, Tomato, Cauliflower, Pepper, and Arabidopsis). The exposure lasted eight months outside the ISS in the MISSE hardware at the Zenith position. Data-loggers and thermoluminescent dosimeters (TLDs) were included in each container to record the environmental data. Temperature profiles and radiation/UV exposure data were also provided by Aegis Aerospace, the MISSE Implementation Partner. In this presentation, the hardware and experimental design, the environmental profiles, and the results of post-flight germination tests will be presented.

Jeffrey T Richards

Exposure of Plant Seeds to the Space Environment Outside the International Space Station

If crop seeds are to be stored on space vehicles for long-duration missions, the effects of the space environment on the seeds must be understood for developing mitigation strategies to prevent seed degradation. The MISSE-Seed project was designed to investigate the effects of space exposure on seed quality and storage. The project also tested the Materials International Space Station Experiment (MISSE) platform for exposing biological samples to the space environment and evaluated the capability of a newly designed passive sample containment vessel for the provision of acceptable storage conditions for seeds, or other biological samples, to be preserved upon exposure to the space environment outside the ISS. The experiment was launched to the ISS on NG-15and returned to Earth aboard SpX-24. The specimens consisted of eleven seed varieties (Lettuce, Scarlet Frills, Amara, Garnet Giant, Pac Choi, Radish, Mizuna, Tomato, Cauliflower, Pepper, and Arabidopsis). The exposure lasted eight months outside the ISS in the MISSE hardware at the Zenith position. Data-loggers and thermoluminescent dosimeters (TLDs) were included in each container to record the environmental data. Temperature profiles and radiation/UV exposure data were also provided by Aegis Aerospace, the MISSE Implementation Partner. In this presentation, the hardware and experimental design, the environmental profiles, and the results of post-flight germination tests will be presented.

Jeffrey T Richards

Using airborne radiometry to determine atmospheric effects in Landsat data

An empirical method was developed to measure how solar and atmospheric conditions affect Landsat images by comparing Landsat MSS data with terrain reflectance. Terrain reflectance was measured with a four-channel radiometer designed to measure radiance in wavelength bands matched to the Landsat MSS data. Other instrumentation included a digital data logger, an irradiance meter, and a video camera with recorder. Reflectance of many terrain elements which could be registered to the Landsat digital data were measured from a low-flying aircraft. Correlations of reflectance with Landsat radiance verified a linear atmospheric model with an additive (path radiance) term and a multiplicative (transmittance) term. Coefficients from this model permit the extension of spectral signatures in computer-aided classification of Landsat images.

Dana, R. W.

Field Evaluation of Portable Soil Water Content Sensors in a Sandy Loam

Ground observations are critical in the validation of soil water content (SWC) estimates from both satellites and land surface models. Portable SWC sensors provide useful information to determine the amount of SWC in the topsoil layer for various applications; however, these probes are not accurate without site‐specific correction. In the present study, we examined and compared six different types of portable electromagnetic (EM) SWC sensors, including multiple sensors made by the same manufacturers, for a total of 16 EM‐based SWC probes equipped with portable data loggers. All SWC probes met the target accuracy after onsite correction—the RMSD was <0.025 m(exp 3) m(exp -3). Using the two‐sample t-tests, we observed that SWC data obtained from similar electrode lengths and from different manufacturers showed similar distributions over time with the same mean. Furthermore, using the maximize R method to combine SWC data from two different types of sensors increased the accuracy of the results. When datasets from two different types of sensors were combined, the Pearson's correlation coefficient (R value) and RMSD values were improved. The average R value improved from .930 to .945, and the RMSD decreased from 0.036 m(exp 3) m(exp -3) to 0.018 m(exp 3) m(exp −3). These results indicate that, along with site‐specific correction, synergetic use of multiple manufacturers’ EM‐based SWC probes can improve the R value and reduce systematic bias.

soil moisture data

Method and Apparatus for Monitoring of Daily Activity in Terms of Ground Reaction Forces

A device to record and analyze habitual daily activity in terms of the history of gait-related musculoskeletal loading is disclosed. The device consists of a pressure-sensing insole placed into the shoe or embedded in a shoe sole, which detects contact of the foot with the ground. The sensor is coupled to a portable battery-powered digital data logger clipped to the shoe or worn around the ankle or waist. During the course of normal daily activity, the system maintains a record of time-of-occurrence of all non-spurious foot-down and lift-off events. Off line, these data are filtered and converted to a history of foot-ground contact times, from which measures of cumulative musculoskeletal loading, average walking- and running-specific gait speed, total time spent walking and running, total number of walking steps and running steps, and total gait-related energy expenditure are estimated from empirical regressions of various gait parameters to the contact time reciprocal. Data are available as cumulative values or as daily averages by menu selection. The data provided by this device are useful for assessment of musculoskeletal and cardiovascular health and risk factors associated with habitual patterns of daily activity.

Whalen, Robert T.

[MODIS Investigation]

The objectives of the last six months were: Continue analysis of Hawaii Ocean Time-series (HOT) bio-optical mooring data, Recover instrumentation from JGOFS cruises in the Southern Ocean and analyze data Maintain documentation of MOCEAN algorithms and software for use by MOCEAN and GLI teams Continue chemostat experiments on the relationship of fluorescence quantum yield to environmental factors. Continue to develop and expand browser-based information system for in situ bio-optical data Work Analysis of Field Data from Hawaii We are continuing to analyze bio-optical data collected at the Hawaii Ocean Time Series mooring. The HOT bio-optical mooring was recovered in May 1998. After retrieving the data, the sensor package was serviced and redeployed. We now have over 18 months of data. These are being analyzed as part of a larger study of mesoscale processes at this JGOFS time series site. We have had some failures in the data logger which have affected the fluorescence channels. These are being repaired. We also had an instrument housing failure, and minor modifications have been made to avoid subsequent problems. In addition, Ricardo Letelier is funded as part of the SeaWiFS calibrator/validation effort (through a subcontract from the University of Hawaii, Dr. John Porter), and he is collecting bio-optical and fluorescence data as part of the HOT activity.

Abbott, Mark R.

A Data-Based Console Logger for Mission Operations Team Coordination

Concepts and prototypes1,2 are discussed for a data-based console logger (D-Logger) to meet new challenges for coordination among flight controllers arising from new exploration mission concepts. The challenges include communication delays, increased crew autonomy, multiple concurrent missions, reduced-size flight support teams that include multidisciplinary flight controllers during quiescent periods, and migrating some flight support activities to flight controller offices. A spiral development approach has been adopted, making simple, but useful functions available early and adding more extensive support later. Evaluations have guided the development of the D-Logger from the beginning and continue to provide valuable user influence about upcoming requirements. D-Logger is part of a suite of tools designed to support future operations personnel and crew. While these tools can be used independently, when used together, they provide yet another level of support by interacting with one another. Recommendations are offered for the development of similar projects.

Thronesbery, Carroll