Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data center design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Data Placement Optimization for ATLAS in a Multi-Tiered Storage System within a Data Center

Scientific experiments and computations, especially in High Energy Physics, are generating and accumulating data at an unprecedented rate. Effectively managing this vast volume of data while ensuring efficient data analysis poses a significant challenge for data centers, which must integrate various storage technologies. This paper proposes addressing this challenge by designing and developing a precise data popularity prediction model utilizing state-of-theart AI/ML techniques. This model is crafted from the analysis of ATLAS data and access patterns. It enables us to migrate infrequently accessed data to more economical storage media, such as tape drives, while storing frequently accessed data on faster yet costlier storage media like HDD or SSD. This strategic approach ensures data is placed optimally into the appropriate storage classes, thereby maximizing storage capacity while minimizing data access latency for end-users. Furthermore, the paper includes a performance evaluation of the prediction model using various key metrics such as F1 score, accuracy, precision and recall. Finally, we present a prototype use case, leveraging real-world file access data to assess the model’s impact on performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Are CO2 batteries ready for the grid? A cross-cutting deployment checklist

Metal-CO2 batteries have attracted considerable research interest in the past decade due to the utilization of the greenhouse CO2 gas. The low cost and abundance of CO2 feedstocks, together with high specific capacity metal anodes, make this technology a promising candidate for electricity-demanding data centers and grids. However, nonstandard data reporting, ambiguous hardware designs, and questionable cycling parameters have emerged as the field has grown. A clear checklist and standardized reporting format for research and development are urgently needed. Here, after carefully re-analyzing 15 Na-CO2 and 9 Li-CO2 studies, we propose a general checklist and a flowchart for CO2 batteries and related gas conversion systems. Specific performance values from a deployment-oriented perspective, based on commercial lithium iron phosphate batteries, are integrated into the list. We frame research and development efforts around grid-relevant outputs, including areal rate and capacity, cyclability, gas utilization, and safety. While illustrated for Na- and Li-CO2 cells, this framework is directly transferable to other CO2 batteries and air/oxygen batteries, helping align benchtop demonstrations with systematic metrics that ultimately govern future deployment.

Wu, Wenda [ORNL] (ORCID:000900033307687X)↗

From Failure to Insight: Analyzing Disk Breakdowns in Large-Scale HPC Environments

Disk failure data provides valuable insights for preventing failures, enhancing storage robustness, guiding system design and deployment, and ensuring reliable operations at data centers. This paper introduces two disk failure datasets collected from large-scale HPC production environments over the past five years, comprising over 5,000 failure records from more than 40,000 disks. We analyzed these datasets across multiple dimensions, including temporal, spatial, and relational trends, and performed a comprehensive reliability assessment. Our analysis yielded numerous observations and insights that influence various operational aspects of HPC storage systems. We believe this study offers a holistic understanding of disk failure trends likely to interest the HPC storage community.

George, Anjus↗

Geospatial characterization of low-temperature heating and cooling demand in residential, commercial, manufacturing, agricultural, and data center sectors for potential geothermal applications in the United States

Thermal demand for heating and cooling has been predominantly supplied by fossil fuel combustion in the United States, although low-carbon alternatives are extensively available including geothermal, solar thermal, and waste heat. Here, this study analyzed end-use energy consumption, fuel expenditure, and data center commissioned power data to geospatially characterize the U.S. low-temperature heating and cooling demand at the county level in residential, commercial, manufacturing, agricultural, and data center sectors and understand potential opportunities for geothermal applications. In the analysis, the regional-scale energy consumption data was incorporated with system efficiencies to address actual demand and was then disaggregated with weighting factors to the county level. The results indicated that total low-temperature heating and cooling demand is 16.7 EJ, combining heating demand of 10.8 EJ and cooling demand of 5.9 EJ. Overall, 59.9 % (10 EJ) of the low-temperature heating and cooling demand occurred in the residential sector. The heating and cooling demand visualized in maps represented that the geospatial distribution of heating and cooling demand in the residential and commercial sectors is governed by the number of housing units and climate zone designations, while heating and cooling demand in the manufacturing, agricultural, and data center sectors is dependent on the number and location of facilities. The results also demonstrated that geothermal heat pumps are broadly used in the residential and commercial sectors for heating and cooling in the U.S. Midwest, South, and Northeast regions but are limited in the West, implying great decarbonization potential in the future.

15 GEOTHERMAL ENERGY↗

Data Structure Alchemy

In an increasingly more data-driven world, the project set out to uncover the first principles of data-structure design, chart the immense design space they form, and build automation that can synthesize an optimal structure, or even a whole storage engine, for any given workload, hardware platform, and cost target. Data structures are at the center of every computational system and are directly responsible for its performance. Two core technical thrusts were defined: 1) Mapping design spaces for key data-centric abstractions (filters, hash functions, storage-engine layouts, neural-network topologies, blockchain protocols, image layouts, etc.). 2) Developing search & synthesis algorithms, initially analytical cost models, later neural-guided bi-level optimisers that navigate sextillions of candidate designs in seconds and materialise the best one as ready‐to-run code. This report distills the key insights, accomplishments, and impact.

97 MATHEMATICS AND COMPUTING↗

The evolution of coal porosity during pyrolysis

Gasification of coal, municipal waste, or other organic materials is a potential hydrogen source that entails complex thermal decomposition and transport processes. This study provides a multiscale analysis of these processes for sub-bituminous (Usibelli, Healy, Alaska) and lignite (Center, North Dakota) coals and provides data useful for process design. The chemistry, mineralogy, and pore structures of pyrolyzed coal and their evolution with thermal decomposition are discussed. Samples pyrolyzed at 200–1000 °C were analyzed by small-angle neutron scattering; ultra-small, small-, and wide-angle X-ray scattering; and other complementary techniques. Scanning electron microscopy showed new pores in the high-temperature-pyrolyzed material. Upon heating, the coals became progressively denser, and the concentration of hydrogen decreased. Changes in pore volume fell into three temperature ranges: an initial, low-temperature range that, for the Usibelli coal, involved an increase in overall porosity; a mid-temperature range associated with pore volume loss; and a high-temperature range associated with significant porosity increase and char formation. This transformation was paralleled by changes in fractal dimension and correlation length. The higher the pyrolysis temperature the greater the small-pore-volume fraction and overall surface area became. Pyrolysis increased the lateral size of coal crystallites, decreased the amorphous fraction, and increased the aromatics fraction and overall coal rank. Comparisons of neutron and X-ray scattering data and subsequent water uptake studies showed that pre-dried coals can re-hydrate relatively rapidly upon exposure to air, which can significantly affect the porosity calculated from small-angle-scattering data. Fits to the cumulative porosity curves provide a method for modeling the physical and chemical transformation of hydrogen-containing feedstock during gasification.

Anovitz, Lawrence {Larry} [ORNL] (ORCID:0000000226↗

Leveraging reVeal for Data Center Siting [Slides]

reVeal (the reV Extension for Analyzing Loads) is an open-source, flexible geospatial platform designed to characterize site suitability, with the goal of informing spatial downscaling and disaggregation of large-scale load projections.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A portable parton-level event generator for the high-luminosity LHC

The rapid deployment of computing hardware different from the traditional CPU+RAM model in data centers around the world mandates a change in the design of event generators for the Large Hadron Collider, in order to provide economically and ecologically sustainable simulations for the high-luminosity era of the LHC. Parton-level event generation is one of the most computationally demanding parts of the simulation and is therefore a prime target for improvements. We present a production-ready leading-order parton-level event generation framework capable of utilizing most modern hardware and discuss its performance in the standard candle processes of vector boson and top-quark pair production with up to five additional jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Continuous Baseline Microphysical Retrieval (MICROBASE) Value-Added Product Report

This technical report describes the Continuous Baseline Microphysical Retrieval (MICROBASE) Value-Added Product (VAP) produced operationally by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility. MICROBASE provides a continuous estimate of cloud microphysical properties at ARM fixed observatories and ARM Mobile Facility (AMF) sites. It is designed to run operationally and provide data to the ARM Data Center for scientific distribution. This technical report presents an overview of the VAP as a resource for data users and ongoing records for major updates to these products.

54 ENVIRONMENTAL SCIENCES↗

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Sustainability in Data Centers: Evaluation of Hybrid Air/Liquid Cooling Schemes for IT Payload Using Sea Water

Abstract-The growth in cloud computing, Big Data, AI and high-performance computing (HPC) necessitate the deployment of additional data centers (DC's) with high energy demands. The unprecedented increase in the Thermal Design Power (TDP) of the computing chips will require innovative cooling techniques. Furthermore, DC's are increasingly limited in their ability to add powerful GPU servers by power capacity constraints. As cooling energy use accounts for up to 40% of DC energy consumption, creative cooling solutions are urgently needed to allow deployment of additional servers, enhance sustainability and increase energy efficiency of DC's. The information in this study is provided from Start Campus' Sines facility supported by Alfa Laval for the heat exchanger and CO 2 emission calculations. The study evaluates the performance and sustainability impact of various data center cooling strategies including an air-only deployment and a subsequent hybrid air/water cooling solution all utilizing sea water as the cooling source. Here we evaluate scenarios from 3 MW to 15+1 MW of IT load in 3 MW increments which correspond to the size of heat exchangers used in the Start Campus' modular system design. This study also evaluates the CO 2 emissions compared to a conventional chiller system for all the presented scenarios. Results indicate that the effective use of the sea water cooled system combined with liquid cooled systems improve the efficiency of the DC, plays a role in decreasing the CO 2 emissions and supports in achieving sustainability goals.

97 MATHEMATICS AND COMPUTING↗

Data Centers and Digital Assurance Workshop 3 – Mitigations for Digital Assurance Risks

The third session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 18, 2025, focused on developing mitigation strategies for digital assurance risks identified in previous workshops. Hosted by Idaho National Laboratory (INL) and ScottMadden, the session emphasized the application of Cyber-Informed Engineering (CIE) to data center infrastructure, particularly at the utility–data center interface. Participants revisited and ranked key digital assurance risks, including architecture and interface weaknesses, governance gaps, and AI-enabled threats. The workshop introduced the 12 principles of CIE, advocating for consequence-focused design, engineered controls, and secure information architecture to proactively reduce cyber-physical vulnerabilities. These principles were applied to critical data center systems such as power distribution, UPS, cooling, SCADA/BMS, and grid-forming batteries. The session also addressed governance challenges at the interconnection boundary, highlighting the need for clear roles in telemetry sharing, firmware management, and trip settings. Special attention was given to emerging risks from behind-the-meter (BTM) generation, including reverse-power flow and the integration of small modular reactors (SMRs), which shift data centers from large loads to complex generation nodes. Participants explored how interconnection agreements can serve as enforceable instruments for digital assurance, and reviewed gaps in current standards such as NERC CIP, IEC 62443, and IEEE 1547. The workshop concluded with pathways to standardization, including model agreement language, state-level programs, and expanded NERC guidance. INL also presented tools and frameworks for secure procurement and supplier risk management, reinforcing the need for integrated engineering and policy solutions to secure the evolving data center–grid ecosystem. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Resilience Planning for Networked Microgrids: A Case Study of Puerto Rico

Microgrids can be designed to enhance the energy resilience of communities and critical infrastructures, such as hospitals, data centers, and communication networks, which are vulnerable to frequent weather-related disruption. Coordinating multiple microgrids in a network can leverage the geographical diversity of load and generation resources while enabling resilient and cost-effective planning of the distribution system. Designing a networked microgrid is complex, involving intricate technical assessment, cost-benefit analysis, site-specific requirements, and the evaluation of existing resources. Therefore, this paper proposes a hierarchical resilience planning framework and performs an extensive techno-economic analysis for the design of a networked microgrid. Hierarchical resilience planning involves technology sizing at an individual community level to meet the critical load and satisfy resilience criteria, and resource optimization at networked microgrid level to provide a higher level of resilience and energy adequacy. A real-world case of Puerto Rico's cooperative microgrid “Microrred de la Montaña” is investigated considering localized electricity tariffs, site-specific demand profiles, solar generation, and existing hydro resources. Multiple optimization scenarios are developed based on the resiliency requirement to estimate the capacity of solar photovoltaic and battery energy storage (BES) to be installed at each substation. The results provide the optimal sizing for individual community and networked microgrid to withstand 1day and 3-day outages along with the criteria for critical load.

13 - HYDRO ENERGY↗

IER 516: Zirconium Test Assembly CED Phase-1: Preliminary Experiment Design

IER-516, Zirconium Test Assembly (ZTA), is a campaign to design, execute, and document a series of high-fidelity critical benchmark experiments to validate current and future zirconium (Zr) and zirconium hydride (ZrH x ) nuclear data evaluations. ZTA is a collaborative project between Los Alamos National Laboratory and the French Autoritè de Sûretè Nuclèaire et de Radioprotection. The experiments will be fueled with highly enriched uranium (HEU), and utilize the Comet critical assembly machine at the National Criticality Experiments Research Center. A total of ten preliminary critical experiments were designed and optimized for Zr and ZrHx nuclear data sensitivities using the MCNP-Particle Swarm Optimization methodology in the thermal, epithermal, intermediate, and fast neutron energy regions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of Part Size, Displacement Rate, and Aging on Compressive Properties of Elastomeric Parts of Different Unit Cell Topologies Formed by Vat Photopolymerization Additive Manufacturing

Due to its ability to achieve geometric complexity at high resolution and low length scales, additive manufacturing (AM) has increasingly been used for fabricating cellular structures (e.g., foams and lattices) for a variety of applications. Specifically, elastomeric cellular structures offer tunability of compliance as well as energy absorption and dissipation characteristics. However, there are limited data available on compression properties for printed elastomeric cellular structures of different designs and testing parameters. In this work, the authors evaluate how unit cell topology, part size, the rate of compression, and aging affect the compressive response of polyurethane-based simple cubic, body-centered, and gyroid structures formed by vat photopolymerization AM. Finite element simulations incorporating hyperelastic and viscoelastic models were used to describe the data, and the simulated results compared well with the experimental data. Of the designs tested, only the parts with the body-centered unit cell exhibited differences in stress–strain responses at different part sizes. Of the compression rates tested, the highest displacement rate (1000 mm/min) often caused stiffer compressive behavior, indicating deviation from the quasi-static assumption and approaching the intermediate rate response. The cellular structures did not change in compression properties across five weeks of aging time, which is desirable for cushioning applications. This work advances knowledge on the structure–property relationships of printed elastomeric cellular materials, which will enable more predictable compressive properties that can be traced to specific unit cell designs.

36 MATERIALS SCIENCE↗

Digital Twin User Guide for Chelan County Public Utility District

This user manual offers a comprehensive guide for developing a Digital twin (DT) of a Kaplan turbine at Chelan County Public Utility District (Chelan PUD) using neural networks. As variable renewable generation expands, hydropower units must operate with optimal efficiency and stability. For Kaplan machines, this flexibility is achieved through coordinated control of guide vane (wicket gates) opening and runner blade pitch, which amplifies the plant’s inherent nonlinear behavior and challenges traditional physics-only modeling. The efficiency of the Kaplan turbine varies with different combinations of the guide vans (wicket gate) opening and the blade angle. Each guide van opening and blade angle has a corresponding highest efficiency point, forming a cam relationship that represents the optimal combination.The discharge of a hydraulic turbine is controlled by the opening angle of the guide vans. Therefore, for each value of head, there is a certain guide van opening and blade angle that corresponds to the highest efficiency. For a given head, different combinations of the guide van opening and blade angle have different efficiencies. Therefore, coordinate cam curves are used to describe the relationship between the wicket gate opening and blade angle with different water head. To address these challenges, the manual details a data-driven modeling and learning workflow centered on structured neural networks. The approach is designed to forecast critical operational variables—discharge flow, net head, penstock (or scroll-case) pressure, and generator electrical outputs—by leveraging real-time inputs such as the generator power control setpoint, exciter field current and field voltage, together with hydromechanical commands (e.g., gate position and, when available, runner blade-pitch angle). The neural models are trained and validated on operational data from a Kaplan unit operated by Chelan PUD, demonstrating that the structured NN architecture can learn the coupled gate–blade–electrical dynamics. The result is a robust DT that improves situational awareness and supports data-informed decision-making for Chelan PUD’s Kaplan turbine operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rapid Evaluation Framework for the CMIP7 Assessment Fast Track

As Earth system models (ESMs) grow in complexity and in volume of output data, there is an increasing need for rapid, comprehensive evaluation of their scientific performance. The upcoming Assessment Fast Track for the Seventh Phase of the Coupled Model Intercomparison Project (CMIP7) will require expeditious response for model analyses designed to inform and drive integrated Earth system assessments. To meet this challenge, the Rapid Evaluation Framework (REF), a community-driven platform for benchmarking and performance assessment of ESMs, was designed and developed. The initial implementation of the REF, constructed to meet the near-term needs of the CMIP7 Assessment Fast Track, builds upon four disparate community evaluation and benchmarking tools that are coupled together using the Coordinated Model Evaluation Capabilities (CMEC) framework. The REF runs within a containerized workflow for portability and reproducibility and is aimed at generating and organizing diagnostics covering a variety of model variables. The REF leverages well documented observational datasets to provide assessments of model fidelity across a collection of diagnostics. All diagnostics were identified and selected with community involvement and consultation. Operational integration with the Earth System Grid Federation (ESGF) will permit automated execution of the REF for selected diagnostics as soon as model output data are published on ESGF by the originating modeling centers. The REF is designed to be portable across a range of current computational platforms to facilitate use by modeling centers for assessing the evolution of model versions or gauging the relative performance of CMIP simulations before being published on ESGF. When integrated into production simulation workflows, results from the REF provide immediate quantitative feedback that allows model developers and scientists to quickly identify model biases and performance issues. After the REF is released to the community, its subsequent development and support will be prioritized by an international consortium of scientists and engineers, enabling a broader impact across Earth science disciplines. For instance, the REF will facilitate improvements to models and will enhance confidence in model projections through process-based selection of models based on their performance with respect to observations. Production of reproducible diagnostics and community-based assessments are key features of the REF. Furthermore, providing interoperability with existing evaluation packages assures that contributions from previous community efforts will be available for use in future model intercomparison projects.

Hoffman, Forrest [ORNL] (ORCID:0000000158024134)↗

Implementation and Demonstration of the Digital Twin Certification System Remote Operations Framework

Microreactors are one promising advanced-reactor concept being pursued by the nuclear industry. They are distinguished by a relatively low power output of 20 MWth or less. These microreactors are intended for deployment in applications where conventional small-capacity power solutions, such as diesel generators, are either economically unfeasible or logistically challenging. Such applications include providing electric power and/or heat for remote communities, mining sites, defense installations, and humanitarian and disaster-relief missions. An important feature for the successful deployment of microreactors is their capability to be operated remotely. This capability can significantly reduce staffing costs by eliminating the need for licensed operators to be physically present at each reactor site. Instead, operators can be centralized in a single remote operations center placed in an economically advantageous location, thereby optimizing resources by consolidating expertise and enhancing operational efficiency. However, the implementation of a remote operation system for nuclear reactors raises new concerns regarding the security, reliability, and resilience of such a system. One way in which remote operations can be supported in a manner that maintains system security, reliability, and resilience is through the use of digital twins in a novel framework designed to verify and validate sensor data and commands communicated between the remote operations center and reactor. This framework, known as the Digital Twin Certification System (DTCS), has previously been proposed as an operations architecture that can bring security and resiliency levels of remote nuclear-reactor operations to a level acceptable for commercial deployment. This paper moves the proposed DTCS architecture from concept to reality by presenting the implementation and testing of the system. The rationale and implementation of the DTCS using tools such as DeepLynx and Apache Airflow, is covered in-depth. This is followed by a demonstration of the DTCS by applying the implemented system architecture to the Single Primary Heat Extraction and Removal Emulator, a small-scale non-nuclear test bed that emulates thermal behavior of a microreactor. The demonstration includes both normal and abnormal operating scenarios to highlight how the DTCS can increase the security, reliability, and resilience of a remote operations system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗