Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data amplification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optimizing de novo genome assembly from PCR-amplified metagenomes

Background. Metagenomics has transformed our understanding of microbial diversity across ecosystems, with recent advances enabling de novo assembly of genomes from metagenomes. These metagenome-assembled genomes are critical to provide ecological, evolutionary, and metabolic context for all the microbes and viruses yet to be cultivated. Metagenomes can now be generated from nanogram to subnanogram amounts of DNA. However, these libraries require several rounds of PCR amplification before sequencing, and recent data suggest these typically yield smaller and more fragmented assemblies than regular metagenomes. Methods. Here we evaluate de novo assembly methods of 169 PCR-amplified metagenomes, including 25 for which an unamplified counterpart is available, to optimize specific assembly approaches for PCR-amplified libraries. We first evaluated coverage bias by mapping reads from PCR-amplified metagenomes onto reference contigs obtained from unamplified metagenomes of the same samples. Then, we compared different assembly pipelines in terms of assembly size (number of bp in contigs ≥ 10kb) and error rates to evaluate which are the best suited for PCR-amplified metagenomes. Results. Read mapping analyses revealed that the depth of coverage within individual genomes is significantly more uneven in PCR-amplified datasets versus unamplified metagenomes, with regions of high depth of coverage enriched in short inserts. This enrichment scales with the number of PCR cycles performed, and is presumably due to preferential amplification of short inserts. Standard assembly pipelines are confounded by this type of coverage unevenness, so we evaluated other assembly options to mitigate these issues. We found that a pipeline combining read deduplication and an assembly algorithm originally designed to recover genomes from libraries generated after whole genome amplification (single-cell SPAdes) frequently improved assembly of contigs ≥ 10kb by 10 to 100-fold for low input metagenomes. Conclusions. PCR-amplified metagenomes have enabled scientists to explore communities traditionally challenging to describe, including some with extremely low biomass or from which DNA is particularly difficult to extract. Here we show that a modified assembly pipeline can lead to an improved de novo genome assembly from PCR-amplified datasets, and enables a better genome recovery from low input metagenomes.

Roux, Simon↗

Optimizing de novo genome assembly from PCR-amplified metagenomes

Background: Metagenomics has transformed our understanding of microbial diversity across ecosystems, with recent advances enabling de novo assembly of genomes from metagenomes. These metagenome-assembled genomes are critical to provide ecological, evolutionary, and metabolic context for all the microbes and viruses yet to be cultivated. Metagenomes can now be generated from nanogram to subnanogram amounts of DNA. However, these libraries require several rounds of PCR amplification before sequencing, and recent data suggest these typically yield smaller and more fragmented assemblies than regular metagenomes. Methods: Here we evaluate de novo assembly methods of 169 PCR-amplified metagenomes, including 25 for which an unamplified counterpart is available, to optimize specific assembly approaches for PCR-amplified libraries. We first evaluated coverage bias by mapping reads from PCR-amplified metagenomes onto reference contigs obtained from unamplified metagenomes of the same samples. Then, we compared different assembly pipelines in terms of assembly size (number of bp in contigs ≥ 10kb) and error rates to evaluate which are the best suited for PCR-amplified metagenomes. Results: . Read mapping analyses revealed that the depth of coverage within individual genomes is significantly more uneven in PCR-amplified datasets versus unamplified metagenomes, with regions of high depth of coverage enriched in short inserts. This enrichment scales with the number of PCR cycles performed, and is presumably due to preferential amplification of short inserts. Standard assembly pipelines are confounded by this type of coverage unevenness, so we evaluated other assembly options to mitigate these issues. We found that a pipeline combining read deduplication and an assembly algorithm originally designed to recover genomes from libraries generated after whole genome amplification (single-cell SPAdes) frequently improved assembly of contigs ≥ 10kb by 10 to 100-fold for low input metagenomes. Conclusions: PCR-amplified metagenomes have enabled scientists to explore communities traditionally challenging to describe, including some with extremely low biomass or from which DNA is particularly difficult to extract. Here we show that a modified assembly pipeline can lead to an improved de novo genome assembly from PCR-amplified datasets, and enables a better genome recovery from low input metagenomes.

Roux, Simon↗

Optimizing de novo genome assembly from PCR-amplified metagenomes

Background. Metagenomics has transformed our understanding of microbial diversity across ecosystems, with recent advances enabling de novo assembly of genomes from metagenomes. These metagenome-assembled genomes are critical to provide ecological, evolutionary, and metabolic context for all the microbes and viruses yet to be cultivated. Metagenomes can now be generated from nanogram to subnanogram amounts of DNA. However, these libraries require several rounds of PCR amplification before sequencing, and recent data suggest these typically yield smaller and more fragmented assemblies than regular metagenomes. Methods. Here we evaluate de novo assembly methods of 169 PCR-amplified metagenomes, including 25 for which an unamplified counterpart is available, to optimize specific assembly approaches for PCR-amplified libraries. We first evaluated coverage bias by mapping reads from PCR-amplified metagenomes onto reference contigs obtained from unamplified metagenomes of the same samples. Then, we compared different assembly pipelines in terms of assembly size (number of bp in contigs ≥ 10 kb) and error rates to evaluate which are the best suited for PCR-amplified metagenomes. Results. Read mapping analyses revealed that the depth of coverage within individual genomes is significantly more uneven in PCR-amplified datasets versus unamplified metagenomes, with regions of high depth of coverage enriched in short inserts. This enrichment scales with the number of PCR cycles performed, and is presumably due to preferential amplification of short inserts. Standard assembly pipelines are confounded by this type of coverage unevenness, so we evaluated other assembly options to mitigate these issues. We found that a pipeline combining read deduplication and an assembly algorithm originally designed to recover genomes from libraries generated after whole genome amplification (single-cell SPAdes) frequently improved assembly of contigs ≥10 kb by 10 to 100-fold for low input metagenomes. Conclusions. PCR-amplified metagenomes have enabled scientists to explore communities traditionally challenging to describe, including some with extremely low biomass or from which DNA is particularly difficult to extract. Here we show that a modified assembly pipeline can lead to an improved de novo genome assembly from PCR-amplified datasets, and enables a better genome recovery from low input metagenomes.

59 BASIC BIOLOGICAL SCIENCES↗

TRT Compton Scattering Data: Comparisons between LLNL and LANL: Pointwise

This memo is one of a pair of reports comparing Compton scattering data in the context of thermal radiation transport (TRT). This document focuses on Pointwise (PW) data while the other report focuses on Multigroup (MG) data. These complementary analyses, via PW comparisons, show if the same physics are used and if fundamental bugs are present, and, via MG comparisons, quantify macroscopic Compton effects such as mean amplification factors. No averaging of Compton data over photon energy is done for the PW comparisons, while lab-dependent numerical resolution choices become relevant for the MG comparisons. This document plots and quantifies differences in PW Compton scattering data between LANL and LLNL for four disparate temperatures on a logarithmically-spaced energy grid. PW comparisons means we use the received LLNL data as-is, without any averaging or integration over energy. In addition to LANL-to-LLNL comparisons, we investigate the impact of numerical choices on LANL PW data. For the purposes of this comparison, we neglect induced scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TRT Compton Scattering Data: Comparisons between LLNL and LANL: Multigroup

This memo is one of a pair of reports comparing Compton scattering data in the context of thermal radiation transport (TRT). This document focuses on Multigroup (MG) data while the other report focuses on Pointwise (PW) data. These complementary analyses, via PW comparisons, show if the same physics are used and if fundamental bugs are present, and, via MG comparisons, quantify macroscopic Compton effects such as mean amplification factors. No averaging of Compton data over photon energy is done for the PW comparisons, while lab-dependent numerical resolution choices become relevant for the MG comparisons. For this MG-comparison report, we make and document the numerical assumptions we use to convert LLNL PW data into MG data. This document plots and quantifies differences in Compton scattering data between MG LANL and LLNL for four disparate temperatures on a logarithmically-spaced photon-energy grid. In addition to LANL and LLNL data, we add a third and fourth independent vote from data generated by Brooks Kinch (LANL postdoc). For the purposes of these comparisons, we neglect induced scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fluorescent amplification for next generation sequencing (FA-NGS) library preparation

BACKGROUND: Next generation sequencing (NGS) has become a universal practice in modern molecular biology. As the throughput of sequencing experiments increases, the preparation of conventional multiplexed libraries becomes more labor intensive. Conventional library preparation typically requires quality control (QC) testing for individual libraries such as amplification success evaluation and quantification, none of which occur until the end of the library preparation process. RESULTS: In this study, we address the need for a more streamlined high-throughput NGS workflow by tethering real-time quantitative PCR (qPCR) to conventional workflows to save time and implement single tube and single reagent QC. We modified two distinct library preparation workflows by replacing PCR and quantification with qPCR using SYBR Green I. qPCR enabled individual library quantification for pooling in a single tube without the need for additional reagents. Additionally, a melting curve analysis was implemented as an intermediate QC test to confirm successful amplification. Sequencing analysis showed comparable percent reads for each indexed library, demonstrating that pooling calculations based on qPCR allow for an even representation of sequencing reads. To aid the modified workflow, a software toolkit was developed and used to generate pooling instructions and analyze qPCR and melting curve data. CONCLUSIONS: We successfully applied fluorescent amplification for next generation sequencing (FA-NGS) library preparation to both plasmids and bacterial genomes. As a result of using qPCR for quantification and proceeding directly to library pooling, the modified library preparation workflow has fewer overall steps. Therefore, we speculate that the FA-NGS workflow has less risk of user error. The melting curve analysis provides the necessary QC test to identify and troubleshoot library failures prior to sequencing. While this study demonstrates the value of FA-NGS for plasmid or gDNA libraries, we speculate that its versatility could lead to successful application across other library types.

59 BASIC BIOLOGICAL SCIENCES↗

Regularized Differentiation for Bioburden Density Estimation in Planetary Protection

In this paper, we propose and investigate the performance of two novel shrinkage estimators for bioburden density estimation in planetary protection. The estimators are based on the regularized differentiation of a cumulative count of colony forming units collected throughout the data collecting session or the life cycle of the entire mission. The regularized differentiation recasts the problem of bioburden density estimation as a linear least squares problem. The least squares problem is then solved through regularization techniques, such as truncated singular value decomposition and penalized least squares. The regularization is necessary to avoid noise amplification during the differentiation of noisy data. The two regularization estimators are compared with four other commonly used estimators to simultaneously evaluate the means of multivariable independent Poisson distributions: the maximum likelihood, noninformative Bayes estimator with Jeffreys prior, Empirical Bayes using conjugate gamma-Poisson model with gamma parameters selected by method of moments, and the Clevenson-Zidek estimator. It is shown through computer-simulated data that the regularized differentiation based on ridge regression has the smallest mean-squared error among all estimators. The analysis of shrinkage mechanism implemented by regularized differentiation is performed, and it is shown that the regularized differentiation amounts to performing a weighted averaging of all the samples. The weights are determined by the regularization parameter automatically selected by the L-curve technique. Since the method of least squares makes no distributional assumptions about the data, it presents an attractive technique for bioburden density estimation when there are concerns about the misspecification of the distributional model. The paper concludes with the analysis of the bioburden data collected during InSight mission and directions for future work.

97 - MATHEMATICS AND COMPUTING↗

Characterizing and mitigating coherent errors in a trapped ion quantum processor using hidden inverses

Quantum computing testbeds exhibit high-fidelity quantum control over small collections of qubits, enabling performance of precise, repeatable operations followed by measurements. Currently, these noisy intermediate-scale devices can support a sufficient number of sequential operations prior to decoherence such that near term algorithms can be performed with proximate accuracy (like chemical accuracy for quantum chemistry problems). While the results of these algorithms are imperfect, these imperfections can help bootstrap quantum computer testbed development. Demonstrations of these algorithms over the past few years, coupled with the idea that imperfect algorithm performance can be caused by several dominant noise sources in the quantum processor, which can be measured and calibrated during algorithm execution or in post-processing, has led to the use of noise mitigation to improve typical computational results. Conversely, benchmark algorithms coupled with noise mitigation can help diagnose the nature of the noise, whether systematic or purely random. Here, we outline the use of coherent noise mitigation techniques as a characterization tool in trapped-ion testbeds. We perform model-fitting of the noisy data to determine the noise source based on realistic physics focused noise models and demonstrate that systematic noise amplification coupled with error mitigation schemes provides useful data for noise model deduction. Further, in order to connect lower level noise model details with application specific performance of near term algorithms, we experimentally construct the loss landscape of a variational algorithm under various injected noise sources coupled with error mitigation techniques. This type of connection enables application-aware hardware codesign, in which the most important noise sources in specific applications, like quantum chemistry, become foci of improvement in subsequent hardware generations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-FG-BRB-06: A Prompt Gamma-Ray Spectroscopy System for Clinical Studies of in Vivo Proton Range Verification

Purpose: We present a new system to perform prompt gamma-ray spectroscopy during proton pencil-beam scanning treatments, which enables in vivo verification of the proton range. This system will be used for the first clinical studies of this technology. Methods: After successful pre-clinical testing of prompt gamma-ray spectroscopy, a full scale system for clinical studies is now being assembled. Prompt gamma-rays will be detected during patient treatment using an array of 8 detector modules arranged behind a tungsten collimator. Each detector module consists of a lanthanum(III) bromide scintillator, a photomultiplier tube, and custom electronics for stable high voltage supply and signal amplification. A new real-time data acquisition and control system samples the signals from the detectors with analog-to-digital converters, analyses events of interest, and communicates with the beam delivery systems. The timing of the detected events was synchronized to the cyclotron radiofrequency and the pencil-beam delivery. Range verification is performed by matching measured energy- and timeresolved gamma-ray spectra to nuclear reaction models based on the clinical treatment plan. Experiments in phantoms were performed using clinical beams in order to assess the performance of the systems. Results: The experiments showed reliable real-time analysis of more than 10 million detector events per second. The individual detector modules acquired accurate energy- and time-resolved gamma-ray measurements at a rate of 1 million events per second, which is typical for beams delivered with a clinical dose rate. The data acquisition system successfully tracked the delivery of the scanned pencil-beams to determine the location of range deviations within the treatment field. Conclusion: A clinical system for proton range verification using prompt gamma-ray spectroscopy has been designed and is being prepared for use during patient treatments. We anticipate to start a first clinical study in the near future. This work was supported by the Federal Share of program income earned by Massachusetts; General Hospital on C06-CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

Fibre amplifier based on an ytterbium-doped active tapered fibre for the generation of megawatt peak power ultrashort optical pulses

We report a new ytterbium-doped active tapered fibre used in the output amplifier stage of a fibre laser system for the generation of megawatt peak power ultrashort pulses in the microjoule energy range. The tapered fibre is single-mode at its input end (core and cladding diameters of 10 and 80 μm) and multimode at its output end (diameters of 45 and 430 μm), but ultrashort pulses are amplified in a quasi-single-mode regime. Using a hybrid Er/Yb fibre system comprising an erbium master oscillator and amplifier at a wavelength near 1.5 μm, a nonlinear wavelength converter to the 1 μm range and a three-stage ytterbium-doped fibre amplifier, we obtained pulses of 1 μJ energy and 7 ps duration, which were then compressed by a grating-pair dispersion compressor with 60% efficiency to a 130 fs duration, approaching the transform-limited pulse duration. The present experimental data agree well with numerical simulation results for pulse amplification in the threestage amplifier. (extreme light fields and their applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

More chemical detection through less sampling: amplifying chemical signals in hyperspectral data cubes through compressive sensing

Compressive sensing (CS) is a method of sampling which permits some classes of signals to be reconstructed with high accuracy even when they were sampled at sub-Nyquist rates. In this paper we explore a phenomenon in which bandwise CS sampling of a hyperspectral data cube followed by reconstruction can actually result in amplification of chemical signals contained in the cube. Perhaps most surprisingly, chemical signal amplification generally seems to increase as the level of sampling decreases. In some examples, the chemical signal is significantly stronger in a data cube reconstructed from 10% CS sampling than it is in the raw, 100% sampled data cube. We explore this phenomenon in two real-world datasets including the Physical Sciences Inc. Fabry-Perot interferometer sensor multispectral dataset and the Johns Hopkins Applied Physics Lab FTIR-based longwave infrared sensor hyperspectral dataset. Each of these datasets contains the release of a chemical simulant, such as glacial acetic acid, triethyl phospate, and sulfur hexafluoride, and in all cases we use the adaptive coherence estimator (ACE) to detect a target signal in the hyperspectral data cube. We end the paper by suggesting some theoretical justifications for why chemical signals would be amplified in CS sampled and reconstructed hyperspectral data cubes and discuss some practical implications.

Hyperspectral imagery, Compressive Sensing, single↗

An experimental topographic amplification study at Los Alamos National Laboratory using ambient vibrations

An experimental study aimed at investigating potential topographic amplification of seismic waves was conducted on a 50-m-tall and 185-m-wide soft-rock ridge located at Los Alamos National Laboratory near Los Alamos, New Mexico. Ten portable broadband seismograph stations were placed in arrays across the ridge and left to record ambient vibration data for ~9 hours. Clear evidence of topographic amplification was observed by comparing spectral ratios calculated from ambient noise recordings at the toe, slope, and crest of the instrumented ridge. The inferred resonance frequency of the ridge obtained from the experimental recordings was found to agree well with several simple estimates of the theoretical resonance frequency based on its geometry and stiffness. Results support the feasibility of quantifying the frequency range of topographic amplification solely using ambient vibrations, rather than strong or weak ground motions. Additionally, comparisons have been made between a number of widely used experimental methods for quantifying topographic effects, such as the standard spectral ratio, median reference method, and horizontal-to-vertical spectral ratio. As a result, differences in the amplification and frequency range of topographic effects indicated by these methods highlight the importance of choosing a reference condition that is appropriate for the site-specific conditions and goals associated with an experimental topographic amplification study.

58 GEOSCIENCES↗

Long-read, whole-genome shotgun sequence data for five model organisms

Single molecule, real-time (SMRT) sequencing from Pacific Biosciences is increasingly used in many areas of biological research including de novo genome assembly, structural-variant identification, haplotype phasing, mRNA isoform discovery, and base-modification analyses. High-quality, public datasets of SMRT sequences can spur development of analytic tools that can accommodate unique characteristics of SMRT data (long read lengths, lack of GC or amplification bias, and a random error profile leading to high consensus accuracy). In this paper, we describe eight high-coverage SMRT sequence datasets from five organisms (Escherichia coli, Saccharomyces cerevisiae, Neurospora crassa, Arabidopsis thaliana, and Drosophila melanogaster) that have been publicly released to the general scientific community (NCBI Sequence Read Archive ID SRP040522). Data were generated using two sequencing chemistries (P4C2 and P5C3) on the PacBio RS II instrument. The datasets reported here can be used without restriction by the research community to generate whole-genome assemblies, test new algorithms, investigate genome structure and evolution, and identify base modifications in some of the most widely-studied model systems in biological research.

59 BASIC BIOLOGICAL SCIENCES↗

Correlations between asymmetric compression, burn amplification, and hot-spot velocities in inertial confinement fusion implosions

Here, this manuscript examines the correlations between the hot-spot velocity (an observable signature of residual kinetic energy), low-mode implosion asymmetries, and burn amplification in inertial confinement fusion implosions on the National Ignition Facility (NIF). Using a combination of two-dimensional axis-symmetric and three-dimensional radiation-hydrodynamic simulations coupled to neutronics, we find that for typical NIF implosions, the stagnation asymmetry multiplies the observed hot-spot velocity anywhere from 80% to 120%, while burn amplification always increases it. Additionally, we find stagnation asymmetry typically deflects the observed hot-spot flow. The two mechanisms (low-mode implosion asymmetries and burn amplification) can be decoupled, and application of a simple model to a database of cryogenic implosions on the NIF infers the total hot-spot velocity amplification. This finding modifies the interpretation of data collected from inertial confinement fusion experiments and impacts the magnitude and origin of low-mode asymmetries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

$\mathrm{SageNet}$: Fast Neural Network Emulation of the Stiff-amplified Gravitational Waves from Inflation

Accurate modeling of the inflationary gravitational waves (GWs) requires time-consuming, iterative numerical integrations of differential equations to take into account their backreaction on the expansion history. To improve computational efficiency while preserving accuracy, we present the Stiff-amplified Gravitational-wave Emulator Network (SageNet), a deep learning framework designed to replace conventional numerical solvers (code available at https://github.com/YifangLuo/SageNet). SageNet employs a long short-term memory architecture to emulate the present-day energy density spectrum of the inflationary GWs with possible stiff amplification, Ω GW (f). Trained on a data set of 25,689 numerically generated solutions, SageNet allows accurate reconstructions of Ω GW (f) and generalizes well to a wide range of cosmological parameters; 90.9% of the test emulations with randomly distributed parameters exhibit errors of under 4%. In addition, SageNet demonstrates its ability to learn and reproduce the artificial, adaptive sampling patterns in numerical calculations, which implement denser sampling of frequencies around changes in spectral indices in Ω GW (f). The dual capability of learning both physical and artificial features of the numerical GW spectra establishes SageNet as a robust alternative to exact numerical methods. Finally, our benchmark tests show that SageNet reduces the computation time from tens of seconds to milliseconds, achieving a speedup of ∼10 4 times over standard CPU-based numerical solvers with the potential for further acceleration on GPU hardware. These capabilities make SageNet a powerful tool for accelerating Bayesian inference procedures for extended cosmological models. In a broad sense, the SageNet framework offers a fast, accurate, and generalizable solution to modeling cosmological observables whose theoretical predictions demand costly differential equation solvers.

Astronomy data modeling↗

Search for a permanent electric dipole moment using liquid 129Xe

Search for an electric dipole moment is one of the best motivated low-energy approaches for investigating physics beyond the Standard Model. Our experimental effort is focused on improving the limit on EDM in liquid 129Xe to put constraints on nuclear CP-violating interactions. High nuclear spin density and high electrical breakdown strength make 129Xe a promising medium for EDM searches. At the time the project started, the transverse nuclear spin relaxation time T2 of 129Xe was unknown. We made measurements of T2 using NMR spin-echo techniques and found that it is exceeds 1300 sec, the longest relaxation time ever measured in a liquid [1]. We also began to investigate non-linear dipolar interaction effects in a high-density spin-polarized liquid Xe. In the second iteration of the experiment we setup a high-Tc SQUID system in magnetic shields and performed detailed studies of Xe spin precession. We developed a model for non-linear dipolar interactions and found that for one set of conditions non-linear interactions can delay spin dephasing due to magnetic field gradients, while for another set of conditions they can lead to exponential amplification of the spin precession signals [2]. Our experimental data were in good quantitative agreement with predictions of the model. We also developed a series of numerical simulations to understand various imperfections in the system and made detailed experimental measurements to confirm these numerical predictions [3]. We demonstrated that non-linear interactions can amplify small precession signals and achieved an amplification factor of 10 [4]. This general phenomenon can be used in other precision measurements with non-linear interactions. We also explored practical applications of the liquid Xe system that we developed. We demonstrated that by mixing Xe with organic liquids, such as cyclopentane, one can enhance the proton spin polarization by a factor of 106 [5]. We have used this technique to perform the first measurement of the scalar J-coupling between nuclear spins in van-der-Waals molecules, something that has never been observed before. More recently, we constructed a liquid-He apparatus to acquire Xe spin precession data using a low-Tc SQUID and achieved a signal-to-noise ratio of 106. We are currently investigating factors affecting the stability of Xe spin precession signals in this system using a superconducting magnetic shield and a persistent current magnetic field coil.

74 ATOMIC AND MOLECULAR PHYSICS↗

Seismic hazard analysis for Jayapura city, Papua

Jayapura city had destructive earthquake which occurred on June 25, 1976 with the maximum intensity VII MMI scale. Probabilistic methods are used to determine the earthquake hazard by considering all possible earthquakes that can occur in this region. Earthquake source models using three types of source models are subduction model; comes from the New Guinea Trench subduction zone (North Papuan Thrust), fault models; derived from fault Yapen, TareraAiduna, Wamena, Memberamo, Waipago, Jayapura, and Jayawijaya, and 7 background models to accommodate unknown earthquakes. Amplification factor using geomorphological approaches are corrected by the measurement data. This data is related to rock type and depth of soft soil. Site class in Jayapura city can be grouped into classes B, C, D and E, with the amplification between 0.5 – 6. Hazard maps are presented with a 10% probability of earthquake occurrence within a period of 500 years for the dominant periods of 0.0, 0.2, and 1.0 seconds.

58 GEOSCIENCES↗