Engineering PapersSearch

SEARCH · Engineering Papers

Results for “dark matter detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

237 records · Page 2

The dynamical origins of the dark comets and a proposed evolutionary track

So-called ‘dark comets’ are small, morphologically inactive near-Earth objects (NEOs) that exhibit nongravitational accelerations inconsistent with radiative effects. These objects exhibit short rotational periods (minutes to hours), where measured. We find that the strengths required to prevent catastrophic disintegration are consistent with those measured in cometary nuclei and expected in rubble pile objects. We hypothesize that these dark comets are the end result of a rotational fragmentation cascade, which is consistent with their measured physical properties. We calculate the predicted size-frequency distribution for objects evolving under this model. Using dynamical simulations, we further demonstrate that the majority of these bodies originated from the 𝜈6 resonance, implying the existence of volatiles in the current inner main belt. Moreover, one of the dark comets, (523599) 2003 RM, likely originated from the outer main belt, although a JFC origin is also plausible. These results provide strong evidence that volatiles from a reservoir in the inner main belt are present in the near-Earth environment.

Aster G Taylor

Cosmological probes of Dark Radiation from Neutrino Mixing

Abstract Models of stepped dark radiation have recently been found to have an important impact on the anisotropies of the cosmic microwave background, aiding in easing the Hubble tension. In this work, we study models with a sector of dark radiation with a step in its abundance, which thermalizes after big bang nucleosynthesis by mixing with the standard model neutrinos. For this, we extend an earlier work which has focused on the background evolution only until the dark sector thermalizes by deriving the full background and perturbation equations of the model and implementing them in an Einstein-Boltzmann solving code. We expound on the behavior of this model, discussing the wide range of parameters that result in interesting and viable cosmologies that dynamically generate dark radiation during a range of epochs. We find that for the strongly self-coupled regime, there is no large cosmological impact for a tight prior on the mass, whereas larger mass ranges allow a smooth interpolation between a behavior close to the ΛCDM cosmological standard model and close to an additional component of strongly self-interacting dark radiation. In the weakly self-coupled regime we find that we can accommodate a parameter space relevant for the neutrino anomalies as well as one relevant to easing the Hubble tension.

Astronomy & Astrophysics

Galaxy Size and Rotation Curve Diversity in ΛCDM with Baryons

The observed rotation curves of dwarf galaxies exhibit significant diversity at fixed halo mass, challenging galaxy formation within the cold dark matter (CDM) model. Previous cosmological galaxy formation simulations with baryonic physics fail to reproduce the full diversity of rotation curves, suggesting that there is a flaw in baryonic feedback models, observational bias, or that an alternative to CDM must be invoked. In this work, we use the Marvelous Massive Dwarf zoom-in simulations, a suite of high-resolution dwarf simulations with M 200 ∼ 10 10 –10 11 M ⊙ and M * ∼ 10 7 –10 9 M ⊙ , designed to target the mass range where the galaxy rotation curve diversity is maximized, i.e., between and 100 km s −1 . We add to this a set of low-mass galaxies from the Marvel Dwarf Zoom Volumes to extend the galaxy mass range to lower values. Our fiducial star formation and feedback models produce simulated dwarfs with a broader range of rotation curve shapes, similar to observations. These simulations both create dark matter cores via baryonic feedback, reproducing the slower-rising rotation curves, while also allowing for compact galaxies and steeply rising rotation curves. Our simulated dwarfs also reproduce the observed size–M * relation, including scatter, producing both extended and compact dwarfs for the first time in simulated field dwarfs. However, the slowly rising and high baryon mass fraction, as well as the steeply rising and low baryon mass fraction, remain missing. We explore star formation and feedback models and conclude that previous simulations may have had feedback that was too strong to produce compact dwarfs.

Cruz, Akaxia [Flatiron Institute, New York, NY (Un

Evidence for large baryonic feedback at low and intermediate redshifts from kinematic Sunyaev-Zel’dovich observations with ACT and DESI photometric galaxies

Recent advances in cosmological observations have provided an unprecedented opportunity to investigate the distribution of baryons relative to the underlying matter. In this work, we show that the gas is more extended than the dark matter, and the amount of baryonic feedback at $z \lesssim 1$ disfavors low-feedback models such as that of state-of-the-art hydrodynamical simulation IllustrisTNG compared with high-feedback models such as that of the original Illustris simulation. This has important implications for bridging the gap between theory and observations and understanding galaxy formation and evolution. Furthermore, a better grasp of the baryon-dark matter link is critical to future cosmological analyses, which are currently impeded by our limited knowledge of baryonic feedback. Here, we measure the kinematic Sunyaev-Zel'dovich (kSZ) effect from the Atacama Cosmology Telescope (ACT), stacked on the luminous red galaxy (LRG) sample of the Dark Energy Spectroscopic Instrument (DESI) imaging survey. This is the first analysis to use photometric redshifts for reconstructing galaxy velocities. Due to the large number of galaxies comprising the DESI imaging survey, this is the highest signal-to-noise stacked kSZ measurement to date: we detect the signal at 13$σ$, finding strong evidence that the gas is more spread out than the dark matter, as well as a preference for larger feedback compared to some commonly used state-of-the-art hydrodynamical simulations. Here, our work opens up the possibility of recalibrating large hydrodynamical simulations using the kSZ effect. In addition, our findings highlight the importance of properly accounting for baryonic feedback with future surveys such as LSST through direct probes such as the kSZ, and shed light on long-standing enigmas in astrophysics, such as the “missing baryon” problem.

79 ASTRONOMY AND ASTROPHYSICS

Pressurized-Cell Experiment

Pressurized-cell detectors were developed and constructed at the Langley Research Center to obtain a direct measurement of the micrometeoroid puncture hazard to thin structural material. A total of 160 detectors were mounted around the periphery of the rocket motor used on the Explorer XIII satellite. (See fig. IX-1.) Material thicknesses of 0.001, 0.0015, 0.002, 0.0025, and 0.005 inch were used on the detectors. The exposed surface of the test material of each detector was 21.8 square inches and the total exposed surface of the 160 detectors was 24.2 square feet. The average weight of the detectors was 68 grams.

Micrometeoroid

Dark energy survey year 3 results: likelihood-free, simulation-based w CDM inference with neural compression of weak-lensing map statistics

We present simulation-based cosmological wcold dark matter (wCDM) inference using dark energy survey year 3 weak-lensing maps, via neural data compression of weak-lensing map summary statistics: power spectra, peak counts, and direct map-level compression/inference with convolutional neural networks (CNN). Using simulation-based inference, also known as likelihood-free or implicit inference, we use forward-modelled mock data to estimate posterior probability distributions of unknown parameters. This approach allows all statistical assumptions and uncertainties to be propagated through the forward-modelled mock data; these include sky masks, non-Gaussian shape noise, shape measurement bias, source galaxy clustering, photometric redshift uncertainty, intrinsic galaxy alignments, non-Gaussian density fields, neutrinos, and non-linear summary statistics. We include a series of tests to validate our inference results. This paper also describes the Gower Street simulation suite: 791 full-sky pkdgrav3 dark matter simulations, with cosmological model parameters sampled with a mixed active-learning strategy, from which we construct over 3000 mock dark energy survey lensing data sets. For wCDM inference, for which we allow –1 < w < –$\frac{1}{3}$⁠, our most constraining result uses power spectra combined with map-level (CNN) inference. Using gravitational lensing data only, this map-level combination gives Ω m = 0.283$^{+0.020}_{–0.027}$⁠, S 8 = 0.804$^{+0.025}_{–0.017⁠}$, and w < –0.80 (with a 68 per cent credible interval); compared to the power spectrum inference, this is more than a factor of two improvement in dark energy parameter (Ω⁠ DE , w⁠) precision.

79 ASTRONOMY AND ASTROPHYSICS

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors

The Impact of Bias Row Noise to Photometric Accuracy: Case Study Based on a Scientific CMOS Detector

Abstract We tested a new model of CMOS detector manufactured by the Gpixel Inc, for potential space astronomical application. In laboratory, we obtain some bias images under the typical application environment. In these bias images, clear random row noise pattern is observed. The row noise also contains some characteristic spatial frequencies. We quantitatively estimated the impact of this feature to photometric measurements, by making simulated images. We compared different bias noise types under strict parameter control. The result shows the row noise will significantly deteriorate the photometric accuracy. It effectively increases the readout noise by a factor of 2–10. However, if it is properly removed, the image quality and photometric accuracy will be significantly improved.

Astronomy & Astrophysics

Electron Velocity Moments in the Solar Wind. I. Calibration of the Wind 3DP EESA Low Detector

Calibrated measurements of electron velocity distribution functions (VDFs) are necessary to characterize fluid and kinetic processes in weakly collisional and nearly collisionless plasmas such as the solar wind. Therefore, we analyzed 3,996,051 electron VDFs observed by the Wind 3DP thermal electron detector near 1 astronomical unit (au) between January 1, 2005 and November 25, 2017. The data were calibrated for each electron VDF to produce accurate velocity moments in the solar wind. This is the first full solar cycle coverage electron velocity moment dataset in the near-Earth solar wind. Herein (Paper I) we discuss the calibration process/algorithms and the velocity moment constraints, uncertainties, and resulting public dataset. In the second paper (Paper II), we statistically analyze the electron velocity moment dataset.

plasmas

Electron/hadron separation with the TRD based on GaAs pixel detectors

Transition Radiation Detectors (TRDs) are widely used for particle identification in both high-energy physics and astroparticle physics. They are typically equipped with gaseous detectors. The main limitation of these types of detectors is that TR photons and ionization losses cannot be decoupled, which significantly reduces the particle separation power. Recent advancements in the development of pixel detectors based on GaAs sensors offer a unique opportunity to effectively detect TR photons and separate them from ionization losses. Such detectors represent novel devices that combine precise tracking capabilities with particle identification (PID) properties. The present work is dedicated to an experimental study of particle identification properties of the TRD prototype based on 500 μ m-thick GaAs sensor bonded to a Timepix3 chip. Studies were performed at the CERN SPS and it was shown that at a particle momentum of 20 GeV/c, the probability of misidentifying a hadron as an electron is below 10 −2 for an electron detection efficiency of 98%–99%, and it is 1 . 6⋅10 −4 for electron detection efficiency of 90%. This performance surpasses the electron/hadron rejection power of all known TRDs by an order of magnitude for the same detector length.

GaAs detectors

Research and Development Related to the Commercialization of Perovskite Radiation Detectors (CRADA Final Report)

This work will focus on the development of perovskite radiation detectors fabricated with nanocrystal, thick polycrystalline films, or single crystal materials. This will harness NREL’s instrumentation and expertise in a variety of research areas including but not limited to metal halide perovskites, device characterization, device packaging, accelerated lifetime testing, and ink chemistry development.

14 SOLAR ENERGY

Kryptonate Hydrogen Detection System (Final Report)

A prototype model of a multipurpose instrument which demonstrates the applicability of the Kryptonate® technique for detecting hydrogen gas was developed. This report describes the construction of the instrument and presents a laboratory evaluation of its performance. Performance was excellent. The instrument was designed to detect hydrogen in air at concentrations of 0-3% by volume, and to detect hydrogen in nitrogen or other inert gas at concentrations of 0-10% by volume. Other detection levels (both higher and lower) could be set if required. Ultimate response times can be made of the order of 0.5 seconds. The instrument is an all solid state device operating from 120V 60 Hz power source. The instrument has been designed to enable modifications to be made with a minimum amount of difficulty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Mitigating electrochemical degradation in CsPbBr{sub 3} gamma detectors by organic and inorganic encapsulation.

CsPbBr3 perovskite semiconductors have emerged as a leading candidate for nextgeneration radiation detectors because of their exceptional charge transport properties, defect tolerance, and record-breaking sensitivity and energy resolution. Their long-term stability, however, is hindered by electrode-driven electrochemical decomposition, which is accelerated by moisture- and oxygen-assisted ion migration during operation. Here, we investigated organic and inorganic encapsulation strategies as both environmental barriers and means to suppress interfacial degradation pathways. Atomic layer deposition (ALD) of Al2O3 provided a conformal passivation layer that blocked environmental ingress, suppressed ionic diffusion, reduced leakage current, enhanced energy resolution and expanded the operational electric-field window beyond 5 kV∙cm1 . By contrast, organic encapsulants such as paraffin wax and polystyrene slowed moisture diffusion but did not suppress interfacial reactions, with wax extending stability to over 90 days. These results show that ALD-Al2O3 suppresses dominant interfacial degradation pathways, enabling stable, high-field operation and advancing the practical deployment of CsPbBr3 γ-ray detectors.

Unal, Mustafa

Optimization of X-ray Absorbers for High-Resolution TES Detectors in NewATHENA X-IFU

NewATHENA’s X-ray Integral Field Unit (X-IFU) uses a large-format array of Transition Edge Sensor (TES) microcalorimeters coupled with absorbers made of gold and bismuth providing 4 eV FWHM resolution up to 7 keV in the 0.2- 12 keV band. X-ray absorbers must be thick enough for photon absorption, maintain low heat capacity for energy resolution, and have good thermalization properties. The X-IFU requires total Quantum Efficiency (QE) of 96%, 87%, and 63% at 1, 7, and 9.5 keV, respectively. Optimal thicknesses are 1.05 µm gold and 5.5 µm bismuth to achieve 0.731 pJ/K at 90 mK and 87% QE at 7 keV. While typical TES absorbers are 3-4 µm thick, producing the required 5.5 µm Bi absorbers via standard electroplating creates enlarged grains and surface roughness. The increased roughness and grain size variability produced with our standard recipe have resulted in instances of 1) low energy spectral tails 2) spectral broadening of the energy resolution and 3) thermal shorts between pixels when a large grain bridges the gap between absorbers. In this study, we have introduced a new fabrication process and altered the morphology of the thick Bi through changes in the electroplating process. The process changes are intended to address all three issues as well as reduce particulate contamination observed on the finished detector arrays.

Absorber

The brighter-fatter effect in the JWST MIRI Si:As IBC detectors: I. Observations, impact on science, and modeling

Context.The Mid-Infrared Instrument (MIRI) on board theJames WebbSpace Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data. Aims.We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps. Methods.We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the publicPoisson_CCDcode. Results.We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of charge-coupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10–25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model.

Astronomy & Astrophysics

Conceptual design study of neutron detectors for safeguards measurement of an irradiated pebble

Nuclear material control and accounting (MC&A) of pebble-bed reactors (PBRs) is challenging because a PBR utilizes hundreds of thousands of identical, unmarked pebbles that are continuously recirculated through the core. To develop tools that enable the implementation of international safeguards, especially in the context of MC&A of spent pebbles, we designed and simulated three neutron detection concepts to determine fissile content in individual pebbles: a differential die-away (DDA) detector, a californium interrogation prompt neutron (CIPN) detector, and a passive neutron albedo reactivity (PNAR) detector using Monte Carlo calculations. Burnup calculations were performed on the spent pebbles from the PBMR-400 classic PBR. The varying neutron and gamma source terms, and isotopic compositions in the spent pebbles calculated at various burnup levels were used in the neutron detector models. DDA was found to be sensitive to the number of passes a pebble has had through the core and to the fissile content contained in a spent pebble. Optimization in the DDA design further increased the neutron count rates and thus reduced counting uncertainty. Meanwhile, passive neutron counting using the same detector body could distinguish pebbles with different numbers of passes, but its response was dominated by neutron-emitting actinides and was not sensitive to fissile content. On the other hand, the PNAR technique was not viable for a single pebble but performed reasonably for a 27-pebble array, which suggested potential use for verification measurements of containers filled with 27 or more spent pebbles.

CIPN