Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dark fiber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Metabolic and morphologic properties of single muscle fibers in the rat after spaceflight, Cosmos 1887

The adaptation of a slow (soleus, Sol) and a fast (medial gastrocnemius, MG) skeletal muscle to spaceflight was studied in five young male rats. The flight period was 12.5 days and the rats were killed approximately 48 h after returning to 1 g. Five other rats that were housed in cages similar to those used by the flight rats were maintained at 1 g for the same period of time to serve as ground-based controls. Fibers were classified as dark or light staining for myosin adenosine triphosphatase (ATPase). On the average, the fibers in the Sol of the flight rats atrophied twice as much as those in the MG. Further, the fibers located in the deep (close to the bone and having the highest percentage of light ATPase and high oxidative fibers in the muscle cross section) region of the MG atrophied more than the fibers located in the superficial (away from the bone and having the lowest percentage of light ATPase and high oxidative fibers in the muscle cross-section) region of the muscle. Based on quantitative histochemical assays of single muscle fibers, succinate dehydrogenase (SDH) activity per unit volume was unchanged in fibers of the Sol and MG. However, in the Sol, but not the MG, the total amount of SDH activity in a 10-microns-thick section of a fiber decreased significantly in response to spaceflight. Based on population distributions, it appears that the alpha-glycerophosphate dehydrogenase (GPD) activities were elevated in the dark ATPase fibers in the Sol, whereas the light fibers in the Sol and both fiber types in the MG did not appear to change. The ratio of GPD to SDH activities increased in the dark (but not light) fibers of the Sol and was unaffected in the MG. Immunohistochemical analyses indicate that approximately 40% of the fibers in the Sol of flight rats expressed a fast myosin heavy chain compared with 22% in control rats. Further, 31% of the fibers in the Sol of flight rats expressed both fast and slow myosin heavy chains compared with 8% in control rats. Immunohistochemical changes in the MG were minimal. These data suggest that the magnitude and direction of enzymatic activity and cell volume changes are dependent on the muscle, the region of the muscle, and the type of myosin expressed in the fibers. Further, the ability of fibers to maintain normal or even elevated activities per unit volume of some metabolic enzymes is remarkable considering the marked and rapid decrease in fiber volume.

NASA Experiment Number COS 1887-26↗

The Dark Energy Spectrographic Instrument (DESI) Optical Fiber System

The specific research of the DESI project is to study in detail the expansion history of the Universe over the past 10 billion years. In order to do this, the project designed, fabricated, tested and commissioned the DESI instrument which has been deployed at the Mayall Telescope at the Kitt Peak National Observatory near Tucson, Arizona. The DESI project was conducted by approximately 30 US and foreign national laboratories. The complete instrument includes a prime focus corrector assembly, a focal plane with 5,000 optical fibers whose position can be set by robotic positioners, and ten spectrographs. Each spectrograph can accommodate the light from 500 fibers and include three color channels that are illuminated by a common collimator mirror and other planar transfer optics. In order for this entire system to work, optical fibers are required to connect each positioner to the spectrographs. Our CRADA with Durham University in the UK provided the 10 crucial fiber cables required to connect the DESI focal plane to the 10 spectrographs. The key major goals of this CRADA were achieved. Survey planning was another key component to the Durham contribution. Drs. Frenk, Baugh, Cole, Edge, Lacey, Li, Lucey, Massey, Metcalfe, Norberg and Shanks were all important contributors to the working groups to which they were assigned. Their work to implement emission lines and QSO in lightcone mocks, mocks for non-standard cosmologies/modified gravity, optimization of completeness of BGS in crowded regions and extended source photometry have been vital in the early planning for targets during commissioning. The major role in the project involved Dr. Ray Sharples and his team. They provided a significant portion of the design, fabrication and testing of the optical fiber system. In particular, they were responsible for the design, production of engineering drawings, component procurements, and fabrication of the 10 DESI Science fiber cables. Working in close collaboration with Dr. Claire Poppett, they also designed and fabricated the slit assemblies, the specialized termination of the groups of 500 fibers which plug into the spectrographs.

47 OTHER INSTRUMENTATION↗

Effects of periodic weight support on medial gastrocnemius fibers of suspended rats

The effects of seven-day-long hindlimb suspension (HS) and HS plus daily periodic weight support activity on the size and metabolic properties of individual fibers in the medial gastrocnemius (MG) of rats were examined. Sections of muscle tissue removed after seven day suspension were stained quantitatively for succinate dehydrogenase and alpha-glycerophosphate dehydrogenase, and qualitatively for myosin ATPase. It was found that short intermittent periods of weight support had a beneficial effect in maintaining the size and metabolic properties of both dark and light ATPase fibers in the deep regions (i.e., close to the bone) and of dark ATPase fibers in the superficial regions of the MG. The effect was greater in the deep regions.

Graham, Scot C.↗

Size and metabolic properties of fibers in rat fast-twitch muscles after hindlimb suspension

The effect of hind-limb suspension (HS) on single fibers of the medial gastrocnemius (MG) and the tibialis anterior (TA) muscles were studied in rats. Fiber area and the activities of succinate dehydrogenase (SDH) and alpha-glycerophosphate dehydrogenase (GPD) were determined in tissue sections using an image analysis system. After 28 days of HS, the MG atrophied 28 percent, whereas the TA weight was maintained. Both dark- and light-ATPase fibers in the deep region of the MG had decreased cross-sectional areas following HS, with the atrophic response being twice as great in the light-ATPase fibers than in the dark-ATPase fibers. Following HS, mean SDH activities of both fiber types were significantly lower in the MG and TA than in the CON; by contrast, mean GPD activities were either maintained at the CON level or were higher in both MG and TA muscles. The data suggest an independence of the mechanisms determining the muscle fiber size and the metabolic adaptations associated with HS.

Roy, Roland R.↗

Multifunction Imaging and Spectroscopic Instrument

A proposed optoelectronic instrument would perform several different spectroscopic and imaging functions that, heretofore, have been performed by separate instruments. The functions would be reflectance, fluorescence, and Raman spectroscopies; variable-color confocal imaging at two different resolutions; and wide-field color imaging. The instrument was conceived for use in examination of minerals on remote planets. It could also be used on Earth to characterize material specimens. The conceptual design of the instrument emphasizes compactness and economy, to be achieved largely through sharing of components among subsystems that perform different imaging and spectrometric functions. The input optics for the various functions would be mounted in a single optical head. With the exception of a targeting lens, the input optics would all be aimed at the same spot on a specimen, thereby both (1) eliminating the need to reposition the specimen to perform different imaging and/or spectroscopic observations and (2) ensuring that data from such observations can be correlated with respect to known positions on the specimen. The figure schematically depicts the principal components and subsystems of the instrument. The targeting lens would collect light into a multimode optical fiber, which would guide the light through a fiber-selection switch to a reflection/ fluorescence spectrometer. The switch would have four positions, enabling selection of spectrometer input from the targeting lens, from either of one or two multimode optical fibers coming from a reflectance/fluorescence- microspectrometer optical head, or from a dark calibration position (no fiber). The switch would be the only moving part within the instrument.

Mouroulis, Pantazis↗

Fiber optic sensors; Proceedings of the Meeting, Cannes, France, November 26, 27, 1985

The conference presents papers on distributed sensors and sensor networks, signal processing and detection techniques, temperature measurements, chemical sensors, and the measurement of pressure, strain, and displacements. Particular attention is given to optical fiber distributed sensors and sensor networks, tactile sensing in robotics using an optical network and Z-plane techniques, and a spontaneous Raman temperature sensor. Other topics include coherence in optical fiber gyroscopes, a high bandwidth two-phase flow void fraction fiber optic sensor, and a fiber-optic dark-field microbend sensor.

Arditty, Herve J.↗

Periodic weight support effects on rat soleus fibers after hindlimb suspension

The morphological and histochemical properties of rat soleus muscles were investigated following one week of hindlimb suspension. Short-duration daily weight support activity is shown to ameliorate, but not prevent, soleus atrophy induced by hindlimb suspension. The results indicate that fiber cross-sectional area is more responsive to periodic weight support in dark than light ATPas fibers, and that muscle fiber atrophy need not be associated with a loss in succinate dehydrogenase activity.

Hauschka, Edward O.↗

Investigating Grain Structure and Microcracking in SiCf-SiCm Composites Using 4D-STEM

Silicon carbide (SiC) fiber-reinforced SiC matrix composites (SiCf-SiCm) are promising materials for accident-tolerant fuel (ATF) cladding in light water reactors. This paper, using four-dimensional scanning transmission electron microscopy (4D-STEM), studied the microstructure of SiCf-SiCm at nanoscale and provided grain statistics at the CVI/fiber region. Here, the results reveal that CVI region mainly contain irregular sub-micron grains (115 nm to 1800 nm) with a preferred orientation, while the fiber region has nano equiaxed grains (21 nm to 78 nm) with random orientations. Centered dark field imaging over the fiber regions verified the grain size measurement by 4D-STEM. Through 4D-STEM virtual dark field imaging and orientation mapping, intragranular propagation was identified as the fracture mechanism for a microcrack observed within the CVI region. The amorphous pyrolytic carbon layer was also shown to effectively arrest the microcrack.

4D-STEM↗

Characterization of DESI fiber assignment incompleteness effect on 2-point clustering and mitigation methods for DR1 analysis

We present an in-depth analysis of the fiber assignment incompleteness in the Dark EnergySpectroscopic Instrument (DESI) Data Release 1 (DR1). This incompleteness is caused by therestricted mobility of the robotic fiber positioner in the DESI focal plane, which limits thenumber of galaxies that can be observed at the same time, especially at small angular separations.As a result, the observed clustering amplitude is suppressed in a scale-dependent manner, which,if not addressed, can severely impact the inference of cosmological parameters. We discuss themethods adopted for simulating fiber assignment on mocks and data. In particular, we introducethe fast fiber assignment (FFA) emulator, which was employed to obtain the power spectrumcovariance adopted for the DR1 full-shape analysis. We present the mitigation techniques,organised in two classes: measurement stage and model stage. We then use high fidelity mocks as areference to quantify both the accuracy of the FFA emulator and the effectiveness of the differentmeasurement-stage mitigation techniques. This complements the studies conducted in a parallelpaper for the model-stage techniques, namely the θ-cut approach. We find that pairwiseinverse probability (PIP) weights with angular upweighting recover the “true” clustering in allthe cases considered, in both Fourier and configuration space. Notably, we present the first everpower spectrum measurement with PIP weights from real data.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of DESI fiber assignment incompleteness effect on 2-point clustering and mitigation methods for DR1 analysis

We present an in-depth analysis of the fiber assignment incompleteness in the Dark Energy Spectroscopic Instrument (DESI) Data Release 1 (DR1). This incompleteness is caused by the restricted mobility of the robotic fiber positioner in the DESI focal plane, which limits the number of galaxies that can be observed at the same time, especially at small angular separations. As a result, the observed clustering amplitude is suppressed in a scale-dependent manner, which, if not addressed, can severely impact the inference of cosmological parameters. We discuss the methods adopted for simulating fiber assignment on mocks and data. In particular, we introduce the fast fiber assignment (FFA) emulator, which was employed to obtain the power spectrum covariance adopted for the DR1 full-shape analysis. We present the mitigation techniques, organised in two classes: measurement stage and model stage. We then use high fidelity mocks as a reference to quantify both the accuracy of the FFA emulator and the effectiveness of the different measurement-stage mitigation techniques. This complements the studies conducted in a parallel paper for the model-stage techniques, namely the θ-cut approach. We find that pairwise inverse probability (PIP) weights with angular upweighting recover the “true” clustering in all the cases considered, in both Fourier and configuration space. Notably, we present the first ever power spectrum measurement with PIP weights from real data.

cosmological simulations↗

Fiber-Optic Strain Sensors With Linear Characteristics

Fiber-optic modal domain strain sensors having linear characteristics over wide range of strains proposed. Conceived in effort to improve older fiber-optic strain sensors. Linearity obtained by appropriate choice of design parameters. Pattern of light and dark areas at output end of optical fiber produced by interference between electromagnetic modes in which laser beam propagates in fiber. Photodetector monitors intensity at one point in pattern.

Egalon, Claudio O.↗

The Robotic Multiobject Focal Plane System of the Dark Energy Spectroscopic Instrument (DESI)

Abstract A system of 5020 robotic fiber positioners was installed in 2019 on the Mayall Telescope, at Kitt Peak National Observatory. The robots automatically retarget their optical fibers every 10–20 minutes, each to a precision of several microns, with a reconfiguration time of fewer than 2 minutes. Over the next 5 yr, they will enable the newly constructed Dark Energy Spectroscopic Instrument (DESI) to measure the spectra of 35 million galaxies and quasars. DESI will produce the largest 3D map of the universe to date and measure the expansion history of the cosmos. In addition to the 5020 robotic positioners and optical fibers, DESI’s Focal Plane System includes six guide cameras, four wave front cameras, 123 fiducial point sources, and a metrology camera mounted at the primary mirror. The system also includes associated structural, thermal, and electrical systems. In all, it contains over 675,000 individual parts. We discuss the design, construction, quality control, and integration of all these components. We include a summary of the key requirements, the review and acceptance process, on-sky validations of requirements, and lessons learned for future multiobject, fiber-fed spectrographs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of poly(phenylacetylene) derivatives for carbon precursor with high carbon yield and good solubility

This paper investigates a family of poly(phenylacetylene) derivatives with a p-electrons conjugated polymer backbone and side groups containing only sp 2 and sp carbons. The objective is to identify the suitable carbon precursor that is processible and can be transformed to carbonaceous material with high carbon yield by a simple (one-step) thermal transformation process (without any external reagent). Poly(phenylacetylene) with para-substituted acetylene group poly(PA-A) shows an exceptionally high C-yield (~90%) in one-step heating from ambient temperature to 1000 °C under N 2 atmosphere. Unfortunately, this poly(PA-A) polymer is quite sensitive to heat and light with very limited solubility. On the other hand, poly(phenylacetylene) with para-substituted phenylacetylene group, i.e. poly(PA-PA), offers a relatively high C-yield (~80%) and also good solubility in common organic solvents, such as toluene and tetrahydrofuran (THF). Several uniform dark-red poly(PA-PA) fibers with smooth surface and fiber diameter in the range of 3–6 μm were prepared from 30 wt% poly(PA-PA)/THF solution using electrospinning technique. Furthermore, the resulting precursor fibers were converted to the corresponding carbon structure in a one-step thermal heating process under N 2 atmosphere. Both X-ray and Raman spectra show the polymorphous carbon morphology with the graphene crystalline domains.

36 MATERIALS SCIENCE↗

Few-Mode Fiber Coupled Superconducting Nanowire Single-Photon Detectors for Photon Efficient Optical Communications

The NASA Glenn Research Center's development of a high-photon efficiency real-time optical communications ground receiver has added superconducting nanowire single-photon detectors (SNSPDs) coupled with few-mode fibers (FMF). High data rate space-to-ground optical communication links require enhanced ground receiver sensitivity to reduce spacecraft transmitter constraints, and therefore require highly efficient coupling from fiber to detector. In the presence of atmospheric turbulence the received optical wave front can be severely distorted introducing higher-order spatial mode components to the received signal. To reduce mode filtering and mismatch loss and the resulting degradations to detector coupling efficiency, we explore the use of few-mode fiber coupling to commercial single-pixel SNSPDs. Graded index 20-µm few-mode fibers allow the commercial single pixel SNSPD's active area to couple with equal efficiency as single mode fibers. Here we determine detector characteristics such as count rate, detection efficiency, dark counts, and jitter, as well as detection efficiencies for higher-order fiber spatial modes. Additionally, we assess the laboratory performance of the detectors in an optical system which emulates future deep space optical communications links.

Vyhnalek, Brian E.↗

Astrometric Calibration and Performance of the Dark Energy Spectroscopic Instrument Focal Plane

Abstract The Dark Energy Spectroscopic Instrument, consisting of 5020 robotic fiber positioners and associated systems on the Mayall telescope at Kitt Peak, Arizona, is carrying out a survey to measure the spectra of 40 million galaxies and quasars and produce the largest 3D map of the universe to date. The primary science goal is to use baryon acoustic oscillations to measure the expansion history of the universe and the time evolution of dark energy. A key function of the online control system is to position each fiber on a particular target in the focal plane with an accuracy of 11 μ m rms 2D. This paper describes the set of software programs used to perform this function along with the methods used to validate their performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physical aging and its influence on the reliability of network epoxies and epoxy-matrix composites

The matrix-dominated physical and mechanical properties of a carbon fiber reinforced epoxy composite and a neat epoxy resin were found to be affected by sub-Tg annealing in nitrogen and dark atmosphere. Postcured specimens of Thornel 300 carbon-fiber/Fiberite 934 epoxy as well as Fiberite 934 epoxy resin were quenched from above Tg and given annealing at 140 C, 110 C, or 80 C, for time up to one-hundred thousand minutes. No weight loss was observed during annealing at these temperatures. Significant variations were found in density, modulus, hardness, damping, moisture absorption ability, thermal expansivity. Moisture-epoxy interactious were also studied. The kinetics of aging as well as the molecular aggregation during this densification process were monitored by differential scanning calorimetry, dynamic mechanical analysis, density gradient column, microhardness tester, Instron, and solid-state nuclear magnetic resonance spectroscopy.

Heinemann, K.↗

The DESI Bright Galaxy Survey: Final Target Selection, Design, and Validation

Over the next 5 yr, the Dark Energy Spectroscopic Instrument (DESI) will use 10 spectrographs with 5000 fibers on the 4 m Mayall Telescope at Kitt Peak National Observatory to conduct the first Stage IV dark energy galaxy survey. At z < 0.6, the DESI Bright Galaxy Survey (BGS) will produce the most detailed map of the universe during the dark-energy-dominated epoch with redshifts of >10 million galaxies spanning 14,000 deg 2 . In this work, we present and validate the final BGS target selection and survey design. From the Legacy Surveys, BGS will target an r < 19.5 mag limited sample (BGS Bright), a fainter 19.5 < r < 20.175 color-selected sample (BGS Faint), and a smaller low-z quasar sample. BGS will observe these targets using exposure times scaled to achieve homogeneous completeness and cover the footprint three times. We use observations from the Survey Validation programs conducted prior to the main survey along with simulations to show that BGS can complete its strategy and make optimal use of "bright" time. BGS targets have stellar contamination <1%, and their densities do not depend strongly on imaging properties. BGS Bright will achieve >80% fiber assignment efficiency. Finally, BGS Bright and BGS Faint will achieve >95% redshift success over any observing condition. BGS meets the requirements for an extensive range of scientific applications. BGS will yield the most precise baryon acoustic oscillation and redshift-space distortion measurements at z < 0.4. It presents opportunities for new methods that require highly complete and dense samples (e.g., N-point statistics, multitracers). BGS further provides a powerful tool to study galaxy populations and the relations between galaxies and dark matter.

79 ASTRONOMY AND ASTROPHYSICS↗

Implementation of quantum key distribution and quantum clock synchronization via time bin encoding

Quantum key distribution allows for a provably secure transmission of cryptographic keys over an optical channel. Encoded polarization states or time-bin degree of freedom have been used for successful demonstrations. However, photon losses in long fibers, slow single photon detectors, and detector dark counts significantly limit the overall bit rate. Improving key throughput and reducing the overhead of key reconciliation remain as major challenges. Methods which utilize multiple time bins allow for multiple key bits to be encoded in a single photon, thus increasing the fidelity of transmitted keys and decreasing the overhead of key reconciliation in real-world conditions. Previous implementations of these methods required that Alice and Bob share a time reference by sharing a dedicated classical channel used for synchronization. This work presents a technique that allows two parties to exchange time-bin encoded photons without the need for synchronized time references. Our technique uses a framing protocol which allows Alice to encode a time reference along with a key which is determined by Alice before transmission. Security can be achieved by monitoring the visibility of a pair of Franson interferometers, using decoy pulses and measuring the round trip time between Alice and Bob. The bit rate of this technique is limited only by the recovery time of the detector and the speed of the modulation electronics. We experimentally demonstrate a raw bit rate of 5Mb/s over an optical channel with 55dB of loss, which is competitive with current research. We also demonstrate absolute timing synchronization with an accuracy of 20ps.

encryption↗