Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cyber modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Critical values of cyber parameters in a dynamic microgrid system

An islanded microgrid can be used to serve critcal load as a resiliency source when a severe outage occurs. In an islanded mode, control of a microgrid relies on the communication system significantly. Hence, microgrids are cyberphysical systems and, therefore, the cyber system plays a crucial role in the performance of the cyber-power system. A microgrid control scheme is proposed for power dispatch and regulation based on the droop and proportional-integral (PI) feedback control. The proposed control strategy is validated for transient stability following dynamic events. To evaluate the impact of a networked control system on control performance, a cyber model is developed to represent data acquisition periods and communication delays. An analytical method is proposed to determine the critical values for the data reporting periods and communication delays. The analytical method based on a state space model of a networked control system is applicable for large-scale systems. A 2-dimensional stability region of a microgrid in the space of cyber parameters can be obtained by the proposed method, and the critical values of cyber parameters are determined based on the stability region. Simulation results validate that the design of a microgrid as a cyber-physical system needs to be guided by critical values for the data reporting period and communication delay to prevent system instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model-based Cyber-attack Detection for Voltage Source Converters in Island Microgrids

With the upgrading of communication and control in microgrids, cyber threats on the power converters are increasing. Here, in this paper, a novel model-based cyber-attack detection methodology is proposed for each voltage source converter in microgrids. The Harmonics State Space Matrix (H-Matrix) is used to build the closed-loop transfer function, providing model-based estimation with the grid voltage and control reference. Then, the space phase model (SPM) is used to calculate residual to detect cyber-attacks in voltage source converter (VSC). As controller and converter parameters are included in the H-matrix, the proposed method also could detect cyber-attacks when voltage fluctuation occurs in the grid. To verify the feasibility of the proposed method, several attacks targeting VSC in an islanded microgrid are simulated in MATLAB. Simulation and detection results are introduced to demonstrate the resilience and feasibility of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Four-Layer Cyber-Physical Security Model for Electric Machine Drives Considering Control Information Flow

Despite the IEEE Power Electronics Society (PELS) establishing Technical Committee 10 on Design Methodologies with a focus on the cyber-physical security of power electronics systems, a holistic design methodology for addressing security vulnerabilities remains underdeveloped. This gap largely stems from the limited integration of computer science and power/control engineering studies in this interdisciplinary field. Addressing the inadequacy of unilateral cyber or control perspectives, this article presents a novel four-layer cyber-physical security model specifically designed for electric machine drives. Central to this model is the innovative control information flow (CIF) model, residing within the control layer, which serves as a pivotal link between the cyber layer's vulnerable resources and the physical layer's state-space models. By mapping vulnerable resources to control variable space and tracing attack propagation, the CIF model facilitates accurate impact predictions based on tainted control laws. The effectiveness and validity of this proposed model are demonstrated through hardware experiments involving two typical cyber-attack scenarios, underscoring its potential as a comprehensive framework for multidisciplinary security strategies.

97 MATHEMATICS AND COMPUTING↗

Development of Integrated Safety and Security Models for Comprehensive Reliability and Resiliency Evaluation

The security of the electric grid and supporting energy systems is crucial to national security. One of the complexities in analyzing the security of energy systems is the safety consequences that may result from accidents. For energy systems, the goal is to ensure that they operate as intended and that any consequences are mitigated or prevented. The integration of safety and security is paramount to protecting these systems from attacks and ensuring that large consequences are prevented. This report describes an integrated safety and security methodology to evaluate cybersecurity events that can lead to large consequences. This novel approach first describes how Systems-Theoretic Process Analysis (STPA) provides a digital causal analysis for Bayesian Networks (BNs). The use of STPA causal analysis provides a systematic approach to constructing BNs that adequately model cyber scenarios that result in consequences. When combined with the technical principles described in Risk-Informed Management of Enterprise Systems (RIMES), a comprehensive risk-informed cybersecurity analysis results that allows decision-makers to prioritize systems that most impact risk.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Risk-Averse Bi-Level Stochastic Network Interdiction Model for Cyber-Security Risk Management

Security of cyber networks is crucial; recent severe cyber-attacks have had a devastating effect on many large organizations. The attack graph, which maps the potential attack paths of a cyber network, is a popular tool for analyzing cyber system vulnerability. In this study, we propose a bi-level stochastic network interdiction model on an attack graph to enable a risk-averse, resource constrained cyber network defender to optimally deploy security countermeasures that protect against attackers with an uncertain budget. This risk- averse conditional-value-at-risk (CVaR) model minimizes a weighted sum of the expected maximum loss over all scenarios and the expected maximum loss from the most damaging attack scenarios. We develop a customized constraint and column generation algorithm to solve our model as well as several acceleration techniques to improve the computational efficiency. Numerical experiments demonstrate that the acceleration techniques enable the solution of relatively large problems within a reasonable amount of time: applying all the acceleration techniques also reduces the average computation time of the basic algorithm by 71% for 100-node graphs. Using metrics called mean-risk value of stochastic solution and value of risk-aversion, computational results suggest that our stochastic risk-averse model significantly outperforms deterministic and risk-neutral models when 1) the distribution of attacker budget is heavy-right-tailed and 2) the defender is highly risk-averse.

Bhuiyan, Tanveer H.↗

Energy Resilience for Mission Assurance, Agile Co-simulation for Cyber Energy System Security (ACCESS) Model Advancements for Resilience Analysis (Version 3, July 2023)

Agile Co-simulation for Cyber Energy System Security (ACCESS) is a co-simulation platform developed by Lawrence Livermore National Laboratory (LLNL). The primary high-level use-case for ACCESS is to study existing or new cyber-physical critical infrastructure systems, with a heavy emphasis on 1) systems that utilize communication networks, and 2) studies that seek to understand cyber-related system impacts. ACCESS is currently used for several energy system resilience projects at LLNL. In the Energy Resilience for Mission Assurance (ERMA) project, ACCESS is used in the Mod eling for Metric Calculation task (specifically, subtask 4.3, Communications and Cyber Modeling) to model and simulate the cyber and communication system aspects of Defense Critical Electric Infrastructure (DCEI) systems, with a focus on computing specific communication system metrics that can impact system resilience and mission performance. Simulated communication system per formance will be fed back to other ERMA system components so that mission performance can be evaluated holistically. This report describes several enhancements to the ACCESS platform that were implemented during the execution of the ERMA project in support of reslience analysis. This includes the addition of new models and subsystems, enhancements to existing models, and integration with external systems. The remainder of this report is structured as follows. In Section 2, a brief background description of the ACCESS platform is provided, including an outline of ACCESS components, example use cases, and a set of communication network resilience metrics that can be computed with ACCESS. Section 3 describes the ACCESS model enhancements for ERMA in detail. Finally, Section 4 briefly outlines future integration opportunities between ACCESS and project participant capabilities identified during the progression of the project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Steady-State Analysis of Microgrid Distributed Control Under Denial of Service Attacks

Distributed control is an effective method to coordinate multiple components in a microgrid. It usually has mandatory requirements for communication graph topology; changing the topology unexpectedly could disrupt the operation of a distributed controller. A denial of service (DoS) attack blocks communication channels to cause variations in communication graph. Unforeseen topology changes render a controller to receive incomplete system information. Control decisions made based on incorrect information can lead to significantly reduced grid supporting capability. As a result, the vital power balance between generation and load may be challenged. Determining power balance requires steady-state power flow analysis; however, the cyber-induced steady-state analysis is not well studied in the literature. Here, in this article, we show that a cyber–physical microgrid with unknown DoS attacks has augmented uncertain power flow equations, whose special structure creates new computational issue to determining power balance. To deal with the issue, we develop a novel cyber-induced microgrid model: the cyber–physical system is transformed into a pure physical model, where the disruption effects of DoS in the cyber layer are shown to be equivalent to the variations of the physical model parameters. With the transformed system, we develop a sufficient condition to ascertain the system power balance under unknown DoS attacks. In addition, practical insights for resilient distributed control design are shown as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A real-time distributed solid oxide electrolysis cell (SOEC) model for cyber-physical simulation

System integration and dynamic operability between SOEC and balance-of-plant (BoP) components are major technical challenges before realizing rapid load following of SOEC systems. Cyber-physical simulation (CPS) is a leading-edge digital engineering approach and is regarded as the next step beyond Digital Twins. CPS approach can be used to research SOEC system integration and develop dynamic controls prior to actual pilot testing without using a real SOEC. To seamlessly couple with BoP hardware and access non-observable operational parameters (e.g., local temperature gradient) during transients, a distributed one-dimensional (1D) real-time SOEC model was developed. Its real-time execution was demonstrated for 20 to 640 nodes at the fixed time step of 5 ms. A higher excess air ratio enabled smaller local temperature gradients on SOEC solid materials and faster transients upon current density step change from 0.15 to 0.55 A cm -2 . During the transients, the magnitude of the peak temperature gradient nearly doubled in 10 s from -3.5 to -5.9 °C cm -1 . This represents a significant operating risk that can impact the dynamic operability of SOEC systems. In addition, the local temperature gradient was found to change directions on all nodes in SOEC solid materials, with the greatest impact on the upstream nodes. The SOEC model was also tested at the thermal neutral voltage using actual process air flow parameters as variable model inputs. Variable process air temperatures were found to induce alternating local temperature gradients on SOEC solid materials. These are new operational mechanisms for SOEC degradation relevant for load following operational modes yet distinct from previous reports. To mitigate these unfavorable features, the SOEC can be operated at voltages that are slightly (±20 mV) deviated from the thermal neutral voltage. Here, the corresponding net thermal energy change was less than 1.6% of the electric power consumption. This 1D real-time SOEC model established the basis of cyber-physical simulation of SOEC hybrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Secure Design and Development Cyber Security Capability Maturity Model” (SD2-CM2)

The "Secure Design and Development Cyber Security Capability Maturity Model" (SD2-CM2) allows electrical system managers to assess the maturity of their cybersecurity systems, including designs reflecting internet of things devices (IOT). The content provides best practices in the field and users can assess the level of their designs. Modules are "Content" and "Infrastructure"

Gourisetti, Sri Nikhil Gupta↗

Cybersecurity Enhancement in Digital Substations: Hidden Markov Model-Based Smart Cyber Switching and Threat Response

The rising incidence of cyber-attacks on critical infrastructure and power grids poses significant threats to the stability and reliability of electrical substations, with potentially devastating consequences such as extended blackouts. This paper introduces an advanced cybersecurity framework aimed at safeguarding IEC 61850-based substations through the integration of software-defined networking (SDN) and digital twin (DT) technologies. The proposed DT-based framework employs smart cyber switching (SCS) for proactive threat mitigation and concurrent intelligent electronic device (CIED) for swift system restoration, thereby maintaining continuous operational integrity and robust cybersecurity defenses. Central to this framework is the adaptive port controller (APC), which enables dynamic port management to adapt to evolving threats, and an intrusion detection system (IDS) designed to detect and neutralize malicious attacks on IEC 61850-based sampled value (SV) and generic object-oriented substation event (GOOSE) messages within the substation’s communication network. Further, novel predictive intrusion detection and response (PIDR) algorithm is implemented on a digital substation (DS) to predict the best route to be taken by the attacker. The efficacy of these comprehensive cybersecurity frameworks is validated through rigorous simulations and a hardware-in-the-loop (HIL) testbed, showcasing the system’s ability to sustain substation operations amidst cyber-attacks.

Digital substation↗

Energy Resilience for Mission Assurance: Agile Co-simulation for Cyber Energy System Security (ACCESS), Model Advancements for Resilience Analysis

Agile Co-simulation for Cyber Energy System Security (ACCESS) is a co-simulation platform developed by Lawrence Livermore National Laboratory (LLNL). The primary high-level use-case for ACCESS is to study existing or new cyber-physical critical infrastructure systems, with a heavy emphasis on 1) systems that utilize communication networks, and 2) studies that seek to understand cyber-related system impacts. ACCESS is currently used for several energy system resilience projects at LLNL. In the Energy Resilience for Mission Assurance (ERMA) project, ACCESS is used in the Modeling for Metric Calculation task (specifically, subtask 4.3, Communications and Cyber Modeling) to model and simulate the cyber and communication system aspects of Defense Critical Electric Infrastructure (DCEI) systems, with a focus on computing specific communication system metrics that can impact system resilience and mission performance. Simulated communication system performance will be fed back to other ERMA system components so that mission performance can be evaluated holistically. This report describes several enhancements to the ACCESS platform that were implemented during the execution of the ERMA project in support of reslience analysis. This includes the addition of new models and subsystems, enhancements to existing models, and integration with external systems. The remainder of this report is structured as follows. In Section 2, a brief background description of the ACCESS platform is provided, including an outline of ACCESS components, example usecases, and a set of communication network resilience metrics that can be computed with ACCESS. Section 3 describes the ACCESS model enhancements for ERMA in detail. Finally, Section 4 briefly outlines future integration opportunities between ACCESS and project participant capabilities identified during the progression of the project.

97 MATHEMATICS AND COMPUTING↗

Systems and methods for controlling an industrial asset in the presence of a cyber-attack

Systems and methods are provided for the control of an industrial asset, such as a power generating asset. Accordingly, a cyber-attack model predicts a plurality of operational impacts on the industrial asset resulting from a plurality of potential cyber-attacks. The cyber-attack model also predicts a corresponding plurality of potential mitigation responses. In operation, a cyber-attack impacting at least one component of the industrial asset is detected via the cyber-attack neutralization module and a protected operational impact of the cyber-attack is identified based on the cyber-attack model. The cyber-attack neutralization module selects at least one mitigation response of the plurality of mitigation responses based on the predicted operational impact and an operating state of the industrial asset is altered based on the selected mitigation response.

D'Amato, Fernando Javier↗

Cyber-Resilient Design Methodology for Microgrids

Recent advancement in tools has helped with microgrid design, development, planning and operation. Microgrids offer a unique application based on users with different requirements for tools. The process of designing, constructing, commissioning, and assessing a microgrid is not always straightforward due to these distinct requirements. Additionally, metrics are needed for performance evaluation. This panel will offer an overview and description of tools that helps with microgrid design, construction, planning, operation, cyber security, and metrics-driven performance assessment driven by multiple diverse applications and use cases.

CCE↗

Communication Network Layer State Estimation Measurement Model for a Cyber-Secure Smart Grid

Network communication has been proven to be a very important tool and a key factor in the recent development and progress of the power grid operation. It is also considered as the foundation for the smart grid because information and communication are integrated into electricity distribution to achieve reliable and accurate knowledge of the power grid. In previous years, absorbing energy from substations and delivering it to customers was the only type of interaction we knew between utility companies and customers. Presently, the growing connections of small distributed generation units caused by the cost reduction of most of the technologies used in generation and storage of electrical energy, along with the potential benefits of renewable energy have pushed many researchers to look into the improvement of information and communication technologies (ICT) in order to ensure a bidirectional flow of power and data. Moreover, the evolution of information and communication technologies and its applications to smart grid have converted the smart grid into a cyber-physical system where vulnerabilities and additional security challenges such as cyber-threats and cyber-attacks have emerged. Previously, we have demonstrated that using machine learning-based processing on data gathered from communication networks and the power grid was a promising solution for detecting cyber threats by implementing a co-simulation of cyber-security for cross-layer strategy. Since the majority of the challenges observed can only be solved in the network communication layer, we present in this work a physics-based state estimation model of the communication network system towards enhanced cyber-physical security of the smart grid. Information integration with the previously developed machine learning model is developed, providing a enhanced cyber-physical security application for the smart grid. Easy-to-implement model, without hard-to-derive parameters, highlight potential aspects of the model for real-life applications.

Mathieu, Reynold↗