Engineering PapersSearch

SEARCH · Engineering Papers

Results for “current sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

High Precision, High Frequency Printed Antennas

An emerging trend in advanced manufacturing is printed electronics and sensors. The ability to print customized electronics and sensors integrated into functional packages is a growing need within a variety of growing markets such as smart manufacturing, internet of things (IoT), and the small satellite industry. Both Oak Ridge National Laboratory (ORNL) and the MITRE Corporation have seedling research efforts evaluating the potential for future printed electronic systems. High frequency, wide-bandwidth phased array antennas (i.e. >45 GHz) open the door to new applications. However, such sensors require currently prohibitively small feature sizes for commercial 3D printing technologies along with increasing challenges with connecting the driving electronics to such features. An additional finding with related advanced manufacturing challenges is the rapid production of 3D additive connectors for integration with commercial printed circuit boards (PCBs), primarily for advanced in-circuit inspection techniques. This work is developing additive manufacturing processes for producing connected and conductive fine scale 3D features. The primary focus was on aerosol-jet printing (AJP), which has a small minimum resolution (<50 µm) but is traditionally printed flat with small height/width aspect ratios <<1, and developing controls to enable fully 3D, high aspect ratio, and unsupported features. In Phase 1 of this effort, baselines of process performance were characterized, and test coupons produced for both ultra-high frequency antennas and microstructures to support reverse engineering of PCBs. In Phase 2, these efforts will be extended for system demonstration of ultra-high frequency antenna arrays, as well as reverse engineering circuitry for dense PCBs.

42 ENGINEERING

Advancing Temperature Monitoring of the Bottom Anode in a Direct Current Electric Arc Furnace Operations with Distributed Optical Fiber Sensors.

The bottom anode in the Direct Current Electric Arc Furnace (DC EAF) is critical for completing the electrical circuit necessary for sustaining the arc within the furnace. For pin-type bottom anodes, monitoring of the temperature of select pins instrumented with thermocouples is performed to track bottom wear in the EAF and inform the operator when the furnace should be removed from service. Furthermore, this work presents the results from a plant trial using distributed temperature monitoring of bottom anode pins in a 165-ton DC EAF over a two-month service period utilizing two optical fiber sensing techniques: fiber Bragg grating (FBG) and Rayleigh backscattering (RBS). The early detection of temperature anomalies along the length of the anode pin through distributed sensing enhances operational safety, providing a robust alternative to traditional thermocouples.

42 ENGINEERING

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER

A Cryogenic readout integrated circuit with analog pile-up and in-Pixel ADC for high frame rate Skipper CCD-in-CMOS Sensors

The Skipper CCD-in-CMOS Parallel Read-Out Circuit V2 (SPROCKET2) is designed to enable high frame rate readout of Skipper CCD-in-CMOS image sensors. The SPROCKET2 pixel is fabricated in a 65 nm CMOS process and occupies a 60$\mu$m $\times$ 60$\mu$m footprint. SPROCKET2 is intended to be heterogeneously integrated with a pixelated Skipper CCD-in-CMOS sensor, such that one readout pixel is connected to a multiplexed array of 16 active image sensor pixels, to match their spatial geometry. Our design benefits from the Skipper CCD-in-CMOS sensor's non-destructive readout capability to achieve exceptionally low noise through multi-sampling and averaging while optimizing for total power consumption. The pixel readout utilizes correlated double sampling to minimize 1/f noise and includes "pile-up" of ten successive samples in the analog domain before digitizing at a rate of 66.7 ksps. Measurement results of in-pixel serial SAR ADC show DNL and INL of ~0. 44 LSB and 0.58 LBS respectively. A large area array of 20,000 SPROCKET2 ADC pixels (multiplexed 1:16 to 320,000 sensor pixels) is currently under test. By reading out data over a 10 Gbps optical link, this pixel design enables a frame rate of $\sim$ 4 kfps for large sensing areas with minimal sensing deadtime. In the highest gain mode, the pixelated ADC has an input-referred resolution of 10$\mu$V with a simulated power consumption of 50$\mu$W. The pixel operates with constant current draw to minimize power-rail crosstalk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

High-resolution in-beam video rate imaging with the ClearXCam for synchrotron beamlines

The ClearXCam detector is a new video rate imaging in-beam monitor based on a diamond sensor. Imaging with 2304 effective pixels is achieved by sequentially biasing one of 48 metal stripes on one side of a diamond sensor, while reading out the current from 48 stripes on the other side of the sensor. This system was characterized for real-time X-ray beam diagnostics at synchrotron beam­line 17-BM at the National Synchrotron Light Source II. Significant results include: detection of in-beam structure via the imaging mode, beam focusing in one minute with real-time imaging feedback during a focusing event, linearity over five orders of magnitude, validation of a fast mode operating at 100 Hz, and sub-micron beam-positioning resolution. The system is now available commercially.

36 MATERIALS SCIENCE

Simulating water dynamics related to pedogenesis across space and time: Implications for four-dimensional digital soil mapping

Digital soil mapping (DSM) relies on machine-learning and geostatistics to represent soil property observations across space. DSM techniques are powerful but often empirical, being limited to the quality and density of point samples. Water dynamics are closely related to soil variability, and the physics that govern water movement are well known. Hydrological properties can hence be simulated by physical models through space and time, unveiling key characteristics about soils. We propose the use of hydrologic models to map soils across the surface (2D), depth (1D), and time (1D)–which provides a 4D approach to digital soil mapping (4DSM). The Distributed Hydrology Soil Vegetation Model (DHSVM) was applied to a watershed currently under pasture. Moisture sensors and wells were installed at different depths in the watershed on summit, sideslope and toeslope positions to validate the model. DHSVM simulations of soil moisture distribution and depth to saturation were performed during the hydrological year (October 2008-September 2009). Clusters of similar pixels based on soil moisture values were determined using Dynamic Time Warping (DTW) to align temporal data and K-means. Clustering was performed both seasonally and for the entire year. Temporal patterns simulated by DHSVM matched measurements given by moisture sensors and wells. Seasonal clusters differed from the annual cluster. Distinct clusters were observed for each season and with depth, showing that spatiotemporal soil variability is lost when statically assessing soils. Spatiotemporal clusters corroborated field observations of fragipan occurrence not explicitly spatially mapped by Soil Survey Geographic Database (SSURGO). If a connection can be made between water and soils, static and dynamic soil variability can be predicted using physically based hydrologic models. Hydrologic models can benefit soil mapping by enabling reliable 4D simulation of water dynamics, which are fundamental to soil variability and soil classification and directly relate to biological, physical and chemical soil processes not captured by typical soil sampling protocols.

54 ENVIRONMENTAL SCIENCES

Low-symmetry vacancy-related spin qubit in hexagonal boron nitride

Abstract Point defect qubits in semiconductors have demonstrated their outstanding capabilities for high spatial resolution sensing generating broad multidisciplinary interest. Hexagonal boron nitride (hBN) hosting point defect qubits have recently opened up new horizons for quantum sensing by implementing sensing foils. The sensitivity of point defect sensors in hBN is currently limited by the linewidth of the magnetic resonance signal, which is broadened due to strong hyperfine couplings. Here, we report on a vacancy-related spin qubit with an inherently low symmetry configuration, the VB2 center, giving rise to a reduced magnetic resonance linewidth at zero magnetic fields. The VB2 center is also equipped with a classical memory that can be utilized for storing population information. Using scanning transmission electron microscopy imaging, we confirm the existence of the VB2 configuration in free-standing monolayer hBN.

Chemistry

In-Situ Process Monitoring Evaluation and Demonstration using Advanced Characterization with Laser Powder Bed Systems

Oak Ridge National Laboratory’s (ORNL) Manufacturing Demonstration Facility (MDF) worked with EOS Group to evaluate the current in-situ sensor capabilities of an EOS M290 Laser Powder Bed Fusion machine. The M290 was fitted with a 1 Mega-Pixel (MP) grayscale visible-light camera and a 5 MP temporally integrated (TI) near-infrared (NIR) camera. One print from stainless steel (SS) 316 and two from Inconel 625 (IN625) were performed where data including in-situ imaging and a machine log file were captured. These data were subsequently analyzed using a Dynamic Multi-Scale Segmentation Convolutional Neural Network (DMSCNN) trained on user defined classes and correlated to as-printed flaws, in the form of porosity, discovered in X-Ray Computed Tomography (XCT). In Phase I, two indications were detected in-situ and spatially correlated to stochastic lack-of-fusion flaws discovered using XCT. In Phase II, using these links from in-situ signatures to XCT flaw populations, a second neural network (NN) was trained to create a Voxelized Property Prediction Model (VPPM) to predict porosity percentages within the part using only features garnered from the in-situ data from two IN625 complex geometries. The VPPM was able to accurately predict porosity values for IN625 parts with an R 2 value of 0.764.

36 MATERIALS SCIENCE

In-Situ Process Monitoring Evaluation and Demonstration using Advanced Characterization with Laser Powder Bed Systems

Oak Ridge National Laboratory’s (ORNL) Manufacturing Demonstration Facility (MDF) worked with EOS Group to evaluate the current in-situ sensor capabilities of an EOS M290 Laser Powder Bed Fusion machine. The M290 was fitted with a 1 Mega-Pixel (MP) grayscale visible-light camera and a 5 MP temporally integrated (TI) near-infrared (NIR) camera. One print from stainless steel (SS) 316 and two from Inconel 625 (IN625) were performed where data including in-situ imaging and a machine log file were captured. These data were subsequently analyzed using a Dynamic Multi-Scale Segmentation Convolutional Neural Network (DMSCNN) trained on user defined classes and correlated to as-printed flaws, in the form of porosity, discovered in X-Ray Computed Tomography (XCT). In Phase I, two indications were detected in-situ and spatially correlated to stochastic lack-of-fusion flaws discovered using XCT. In Phase II, using these links from in-situ signatures to XCT flaw populations, a second neural network (NN) was trained to create a Voxelized Property Prediction Model (VPPM) to predict porosity percentages within the part using only features garnered from the in-situ data from two IN625 complex geometries. The VPPM was able to accurately predict porosity values for IN625 parts with an R 2 value of 0.764.

36 MATERIALS SCIENCE

Thermal Studies of CMS High-Granularity Calorimeter (HGCAL) Cassettes for the HL-LHC Upgrade

The CMS High Granularity Calorimeter (HGCAL) is a key endcap upgrade for the High-Luminosity LHC, designed to operate in an environment of extreme radiation and high particle rates. Each HGCAL cassette integrates silicon and scintillator modules, front-end ASICs, and a copper cooling plate that provides both mechanical integrity and thermal coupling using two-phase CO₂ cooling. Stable and uniform temperature control is essential to ensure reliable performance of the front-end electronics and to limit radiation-induced leakage currents in the silicon sensors. We present results from thermal characterization studies of pre-series HGCAL cassettes assembled and tested at Fermilab. Embedded RTD/PT1000 temperature sensors were used to measure gradients across copper cooling plates, module layers, and cassette edges under powering conditions representative of operation. The measured thermal behavior demonstrates effective heat transport through the cassette stack and highlights small but systematic variations correlated with geometry and assembly tolerances. These results validate the cooling performance of HGCAL cassettes.

Wang, Jinglu [Northwestern U.]

Flow Sensor Test Article (F-STAr) - Water Testing and Commissioning Report for FY2024

Argonne National Laboratory’s Mechanism Engineering Test Loop (METL) facility is developing new experimental testing capabilities with the Flow Sensor Test Article (F-STAr). F-STAr’s mission is to provide high flowrate, sodium submersible testing capabilities to support the development of sodium cooled nuclear fission reactors. Figure 1 shows a model of F-STAr (left) and a photo of the partially assembled test article (right) with several of the main components labeled. The system currently includes a large pump with desired flowrates of up to 100 GPM; an immersion heater with a maximum power of 5 kW; an immersion cooler with an estimated maximum cooling power of 2 kW; and an experimental test section to support sub-test articles. Initially, F-STAr will be setup for testing flow sensors, specifically Eddy Current Flow Sensors (ECFS). However, the system can be reconfigured to support a wide range of testing needs. For example, F-STAr could be setup to complete testing of hydraulic components, heat exchangers, hydrodynamic bearings, seals, and more. This report will provide an update on the development of F-STAr with a focus on the water testing and commissioning activities during Fiscal Year 2024 (FY24). First, the report will focus on describing the pump development. Specifically, updates will be provided on troubleshooting the pump’s excessive vibrational issues. In addition to updates on the pump, pressure-flowrate performance testing in water will be described. Furthermore, updates will be provided on a pump shaft bushing development as well as rigging procedures. Future work and paths forward for F-STAr will be described. Finally, a short summary on the ECFS development will be described at the end of the report.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Addressing Low-Cost Methane Sensor Calibration Shortcomings with Machine Learning

Quantifying methane emissions is essential for meeting near-term climate goals and is typically carried out using methane concentrations measured downwind of the source. One major source of methane that is important to observe and promptly remediate is fugitive emissions from oil and gas production sites but installing methane sensors at the thousands of sites within a production basin is expensive. In recent years, relatively inexpensive metal oxide sensors have been used to measure methane concentrations at production sites. Current methods used to calibrate metal oxide sensors have been shown to have significant shortcomings, resulting in limited confidence in methane concentrations generated by these sensors. To address this, we investigate using machine learning (ML) to generate a model that converts metal oxide sensor output to methane mixing ratios. To generate test data, two metal oxide sensors, TGS2600 and TGS2611, were collocated with a trace methane analyzer downwind of controlled methane releases. Over the duration of the measurements, the trace gas analyzer’s average methane mixing ratio was 2.40 ppm with a maximum of 147.6 ppm. The average calculated methane mixing ratios for the TGS2600 and TGS2611 using the ML algorithm were 2.42 ppm and 2.40 ppm, with maximum values of 117.5 ppm and 106.3 ppm, respectively. A comparison of histograms generated using the analyzer and metal oxide sensors mixing ratios shows overlap coefficients of 0.95 and 0.94 for the TGS2600 and TGS2611, respectively. Overall, our results showed there was a good agreement between the ML-derived metal oxide sensors’ mixing ratios and those generated using the more accurate trace gas analyzer. This suggests that the response of lower-cost sensors calibrated using ML could be used to generate mixing ratios with precision and accuracy comparable to higher priced trace methane analyzers. This would improve confidence in low-cost sensors’ response, reduce the cost of sensor deployment, and allow for timely and accurate tracking of methane emissions.

03 NATURAL GAS

Output Current Estimation and Control in Primary Side LCC Secondary Side Series Compensated Wireless Power Transfer System without Secondary Side Sensors

The estimation (and control) of the output variables is often challenging for wireless power transfer (WPT) systems. This paper presents a secondary side sensor-less closed loop estimation technique to estimate the output current in a primary side LCC and secondary side series compensated WPT system. Using information of primary side variables, the proposed estimation can estimate the output current over a wide range of load current variations. Results are presented to verify the efficacy of the proposed estimation.

Mukherjee, Subho [ORNL] (ORCID:0009000672297925)

Precision Timing in CMS at the HL-LHC: Current Progress on Validation and Production

During the High Luminosity phase of LHC, up to 200 proton-proton collisions per bunch crossing will bring severe challenges for event reconstruction. To mitigate pileup effects, an extended upgrade program of the CMS experiment is expected. Among which, a new timing layer, the MIP Timing Detector (MTD), will be integrated between the tracker and the calorimeters. With a time resolution of 30-60 ps, the MTD will enable 4D vertexing, bringing significant improvements in track-to-vertex association and object identification. The MTD is composed of two subsystems based on different technologies: the Barrel Timing Layer (BTL) consists of LYSO:Ce scintillating crystals readout by SiPMs, and the Endcap Timing Layer (ETL) is made of Low-Gain Avalanche Diodes. The BTL is currently under production, while ETL sensor prototyping and validation are ongoing. Recent system tests have confirmed the performance of the full acquisition chain. This talk will provide an overview of the MTD design, along with the physics motivation, and the current status of BTL construction and ETL development.

Safdari, Murtaza [Fermilab] (ORCID:000000018323731

The future of subsurface monitoring: AEC’s breakthroughs in CCS technology

Carbon capture and storage (CCS) has emerged as a key solution in the fight against climate change. However, for CCS to succeed, it is crucial to ensure that the sequestered CO2 stays safely trapped underground. The U.S. Department of Energy (DOE) has emphasized the need for advancements in subsurface monitoring, measurement, reporting, and verification. Aside from caprock integrity failure, the other primary failure points usually involve defective cement in the casing annulus of wellbores or plugged and abandoned wells. In addition, many energy producers (e.g., oil and gas, geothermal) and storage and disposal operators (e.g., H2 and water) must deal with the same issue. Poorly placed or degraded cement can create pathways for gas or fluid to escape from casing annuli and in plugged and abandoned or orphan wells, posing environmental risks. Yet, a reliable and cost-effective way to monitor cement and well integrity over multiple decades is still unavailable. Traditional geophysical methods like 4D seismic imaging and surface-based electromagnetic monitoring lack the resolution and accuracy for detecting these types of failures (Vasco et al., 2022; Fawad and Mondol, 2021). Wireline logging is expensive to run continuously and is obtrusive to the operation. While fiber optics can potentially be a solution, its bulkiness can significantly compromise the cement's integrity. To address these challenges, the Advanced Energy Consortium (AEC) at The University of Texas at Austin’s Bureau of Economic Geology (the Bureau) has been pioneering research in subsurface monitoring using its portfolio of distributed autonomous microfabricated sensors for harsh subsurface environments since 2008. A class of these microsensors [System on a Chip (SoC)] can be mixed in cement and permanently placed without compromising the cement column; the sensors would then communicate with each other or a data acquisition (DAQ) master node. Another class of the AEC microsensors can be fully autonomous, with rechargeable micro-batteries capable of exceeding 100°C, flash memory, and, currently, a pressure and temperature sensor. They are designed to circulate in mud, geothermal fluids, U-loops, or pipelines. They can log data into memory and are unobtrusive to operations. Our team has been working on a multi-year DOE-funded project (DE-FE0031856)—supported by $2.95M in federal funding and $0.75M in cost-matching from the AEC—to demonstrate SoC sensor utility for CO2 leakage monitoring in CCS applications. This multi-institutional collaboration developed a novel sensing architecture utilizing radiofrequency (RF) microsensors embedded within the cement sheath. These sensors detect CO2 migration and are interrogated via a Smart Casing Collar (SCC).

58 GEOSCIENCES

Dynamic Heat Flow and Current Distribution Analysis in the Bottom Anode of an Electric Arc Furnace Using Fiber-Optic Sensors

A reliable method for monitoring bottom anode wear during DC Electric Arc Furnace (DC-EAF) operation is of critical importance for safe and efficient steel production. Underestimation of bottom wear poses a serious safety risk that must be avoided, while overestimation of bottom wear also poses challenges, as premature anode replacement is expensive and affects EAF productivity. Previously, we demonstrated that fiber-optic sensors can be successfully deployed to create a spatially distributed temperature map to monitor the health of the anode. The present work explores the heat flow and current density distribution in bottom anode pins to predict bottom wear, steel penetration events, and monitor refractory erosion. Small dynamic variations in pin temperature induced by joule heating during arcing also provide a means to observe local current flows in each pin. When mapped, these measurements provide a real-time view of the non-uniform and dynamic current flow in the bottom anode during EAF operation that can affect bottom wear.

Bottom Anode

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION

Development Status of the KIPM Detector Consortium

A kinetic inductance phonon-mediated detector is a calorimeter that uses kinetic inductance detectors (KIDs) to read out phonon signals from the device substrate. We have established a consortium comprising university and national lab groups dedicated to advancing the state of the art in these detectors, with the ultimate goal of designing a detector with sub-eV threshold on energy deposited in the substrate, enabling searches for both light dark matter and low-energy neutrino interactions. This consortium brings together experts in KID design, phonon and quasi-particle dynamics, and noise modeling, along with specialized fabrication facilities, test platforms, and unique calibration capabilities. Recently, our consortium has demonstrated a resolution on energy absorbed by the sensor of 2.1 eV, the current record for phonon-sensitive KIDs. However, due to ∼ 1% phonon collection efficiency, the overall detector resolution was limited to 320 eV. Finally, the current focus of the consortium is modeling and improving the phonon collection efficiency and implementing low-T c superconductors, both of which serve to improve the overall energy resolution and threshold of the detectors.

Temples, Dylan J. [Fermi National Accelerator Labo