Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “crystallization contaminants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Large-scale 2D heterostructures from hydrogen-bonded organic frameworks and graphene with distinct Dirac and flat bands

The current strategies for building 2D organic-inorganic heterojunctions involve mostly wet-chemistry processes or exfoliation and transfer, leading to interface contaminations, poor crystallizing, or limited size. Here we show a bottom-up procedure to fabricate 2D large-scale heterostructure with clean interface and highly-crystalline sheets. As a prototypical example, a well-ordered hydrogen-bonded organic framework is self-assembled on the highly-oriented-pyrolytic-graphite substrate. The organic framework adopts a honeycomb lattice with faulted/unfaulted halves in a unit cell, resemble to molecular “graphene”. Interestingly, the topmost layer of substrate is self-lifted by organic framework via strong interlayer coupling, to form effectively a floating organic framework/graphene heterostructure. The individual layer of heterostructure inherits its intrinsic property, exhibiting distinct Dirac bands of graphene and narrow bands of organic framework. Our results demonstrate a promising approach to fabricate 2D organic-inorganic heterostructure with large-scale uniformity and highly-crystalline via the self-lifting effect, which is generally applicable to most of van der Waals materials.

36 MATERIALS SCIENCE↗

Twelve-crystal prototype of Li 2 MoO 4 scintillating bolometers for CUPID and CROSS experiments

An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, μBq/kg, level of the LMO crystals radioactive contamination by 228 Th and 226 Ra.

47 OTHER INSTRUMENTATION↗

GaAs vapor-grown bipolar transistors.

Discussion of an approach for the fabrication of high-temperature GaAs transistors which is centered on the preparation of n-p-n three-layered structures entirely by a vapor-phase growth technique, as described by Tietjen and Amick (1966). The low growth temperature of approximately 750 C is thought to reduce contamination during crystal growth and to contribute to the reasonably high minority-carrier lifetimes obtained for the vapor-grown p-n junctions. The fact that impurity concentrations and layer thicknesses can be precisely controlled for epitaxial layers as thin as 1 micrometer is an important feature of this growth technique.

Nuese, C. J.↗

The community satellite. III

A number of technology experiments conducted with the satellite are discussed, giving attention to a very high resolution radiometer experiment, a radio frequency interference experiment, a millimeter wave propagation experiment, a COMSAT propagation experiment, a cesium bombardment ion engine experiment, an advanced thermal control flight experiment, a spacecraft attitude experiment, a radio beacon experiment, and environmental measurements experiments. Special investigations considered are related to the use of a spacecraft vibration accelerometer, a quartz crystal microbalance contamination monitor, and a television camera.

Source record↗

The study of 'microsurfaces' using thermal desorption spectroscopy

The use of a newly combined ultrahigh vacuum technique for studying continuous and particulate evaporated thin films using thermal desorption spectroscopy (TDS), transmission electron microscopy (TEM), and transmission electron diffraction (TED) is discussed. It is shown that (1) CO thermal desorption energies of epitaxially deposited (111) Ni and (111) Pd surfaces agree perfectly with previously published data on bulk (111) single crystal, (2) contamination and surface structural differences can be detected using TDS as a surface probe and TEM as a complementary technique, and (3) CO desorption signals from deposited metal coverages of one-thousandth of a monolayer should be detectable. These results indicate that the chemisorption properties of supported 'microsurfaces' of metals can now be investigated with very high sensitivity. The combined use of TDS and TEM-TED experimental methods is a very powerful technique for fundamental studies in basic thin film physics and in catalysis.

Thomas, M. E.↗

Containerless Manufacture of Glass Optical Fibers

Contamination and crystallization reduced in proposed process. Solid optical fiber drawn from an acoustically levitated lump of molten glass. New material added in solid form, melted and then moved into main body of molten glass. Single axis acoustic levitation furnances levitate glass melts at temperature up to about 700 degrees C. Processing in unit limited to low-melting temperature glasses.

Naumann, R. J.↗

Protective Package for a Gamma-Ray Detector

Package for germanium gamma-ray detector protects semiconductor crystal from contamination, allows it to operate at high voltages, and isolates from shock and vibration. Package seals detector from its surroundings, whether in atmosphere or in vacuum of space. Main parts of package made of aluminum. Cover sealed to base by soft aluminum ring.

Fong, M.↗

Contamination and Radiation Effects on Nonlinear Crystals for Space Laser Systems

Space Lasers are vital tools for NASA s space missions and military applications. Although, lasers are highly reliable on the ground, several past space laser missions proved to be short-lived and unreliable. In this communication, we are shedding more light on the contamination and radiation issues, which are the most common causes for optical damages and laser failures in space. At first, we will present results based on the study of liquids and subsequently correlate these results to the particulates of the laser system environment. We present a model explaining how the laser beam traps contaminants against the optical surfaces and cause optical damages and the role of gravity in the process. We also report the results of the second harmonic generation efficiency for nonlinear optical crystals irradiated with high-energy beams of protons. In addition, we are proposing to employ the technique of adsorption to minimize the presence of adsorbing molecules present in the laser compartment.

Abdeldayem, Hossain A.↗

Investigating Influential Parameters for High-Purity Germanium Crystal Growth

This paper focuses on the research and development of high-purity germanium (HPGe) crystals for detector fabrication, specifically targeting applications in rare-event physics searches. The primary objective was to produce large-scale germanium crystals weighing >1 kg with a controlled diameter of ∼10 cm and an impurity range of approximately 1010/cm 3. Ensuring structural integrity and excellent crystalline quality requires a thorough assessment of dislocation density, a critical aspect of the crystal development process. Dislocation density measurements play a crucial role in maximizing the sensitivity of HPGe detectors, and our findings confirmed that the dislocation density fell within acceptable ranges for detector fabrication. Additionally, this paper examines the segregation coefficient of various contaminants during the crystal development process. Comprehensive analysis of impurity segregation is essential for reducing contaminant quantities in the crystal lattice and customizing purification processes. This, in turn, minimizes undesired background noise, enhancing signal-to-noise ratios for rare-event physics searches and overall detector performance. The investigation included the segregation coefficients of three major acceptors and one donor in crystals grown at the University of South Dakota, providing valuable insights for optimizing crystal purity and detector efficiency.

Bhattarai, Sanjay↗

SM-ND isotopic studies of proterozoic anorthosites Systematics and implications

Sm-Nd isotopic studies of anorthosites can be used to provide information on their ages of crystallization and metamorphism, contamination history, and mantle sources. Proterozoic anorthosites in the Grenville and Nain Provinces of eastern North America crystallized between about 1100 and 1600 Ma, and some were metamorphosed at about 1000 Ma. Grenville Province anorthosite massifs were derived from depleted mantle. It is not clear whether massifs and related mafic intrusions throughout the Nain Province of Labrador were derived from enriched mantle, or were contaminated by early Archean (greater than 3500 Ma) silicic crustal materials, heretofore thought to be restricted to coastal Labrador.

Ashwal, L. D.↗

A Method for Incorporating Quartz Crystal Microbalance Thermo-Gravimetric Assessment Data in Contamination Modeling

The science objectives of increasingly ambitious space missions require meeting stringent contamination requirements. Contamination transport models are based on established principles such as Fick’s law for contamination diffusion within the source material, Arrhenius factors to account for temperature variations and free molecular transport for spacecraft operating in vacuum. In addition to the science principles, empirical data obtained from ASTM E1559 testing is used for engineering contamination modeling. The ASTM E1559 test provides outgassing rate data for materials at expected spacecraft temperatures during a mission. Multiple quartz crystal microbalances (QCMs) can be operated at different temperatures to measure the amount of contamination condensation that can occur on various spacecraft surfaces. At the conclusion of the ASTM E1559 test a thermo-gravimetric assessment (TGA) can be performed by heating the QCMs at a linear rate to obtain contamination desorption data. This TGA data provides a wealth of information that can be incorporated into contamination models. A method for applying this data is presented.

Anderson, John R↗

The Opera Instrument: An Advanced Curation Development for Mars Sample Return Organic Contamination Monitoring

Mars Sample Return (MSR) requires strict organic contamination control (CC) and contamination knowledge (CK) as outlined by the Mars 2020 Organic Contamination Panel (OCP). This includes a need to monitor surficial organic contamination to a ng/sq. cm sensitivity level. Archiving and maintaining this degree of surface cleanliness may be difficult but has been achieved. MSR's CK effort will be very important because all returned samples will be studied thoroughly and in minute detail. Consequently, accurate CK must be collected and characterized to best interpret scientific results from the returned samples. The CK data are not only required to make accurate measurements and interpretations for carbon-depleted martian samples, but also to strengthen the validity of science investigations performed on the samples. The Opera instrument prototype is intended to fulfill a CC/CK role in the assembly, cleaning, and overall contamination history of hardware used in the MSR effort, from initial hardware assembly through post-flight sample curation. Opera is intended to monitor particulate and organic contamination using quartz crystal microbalances (QCMs), in a self-contained portable package that is cleanroom-compliant. The Opera prototype is in initial development capable of approximately 100 ng/sq. cm organic contamination sensitivity, with additional development planned to achieve 1 ng/sq. cm. The Opera prototype was funded by the 2017 NASA Johnson Space Center Innovation Charge Account (ICA), which provides funding for small, short-term projects.

Fries, M. D.↗

Using a temperature-controlled quartz crystal microbalance in a space equipment cleanroom to monitor molecular contamination

There is a need for continuous monitoring for molecular contamination in clean rooms where spaceflight equipment is assembled, integrated, and tested to insure that contamination budgets are met. The TQCM (temperature-controlled quartz crystal microbalance) can be used to provide both a real time warning and a cumulative measurement of molecular contamination. It has advantages over the other measurement methods such as witness mirrors, NVR (non-volatile residue) plates, and gas analyzers. A comparison of the TQCM sensitivity and ease of operations is made with the other methods. The surface acoustic wave microbalance (SAW), a newly developed instrument similar to TQCM, is considered in the comparison. An example is provided of TQCM use at Goddard Space Flight Center when the Wide Field Planetary Camera 2(WFPC-2) and the Corrective Optics Space Telescope Axial Replacement (COSTAR) were undergoing integrated testing prior to their installation in the Hubble Space Telescope on its first servicing mission. Areas for further investigation are presented.

Mitchell, William J.↗

Overview of the Lunar Gateway External Contamination Environment

As a part of the Artemis mission, Gateway will be a long duration space station in a near rectilinear halo orbit around the Moon. Gateway will be exposed to a variety of external contamination sources, which can degrade external hardware / surfaces and impact science utilization objectives. Requirements and methodologies addressing material outgassing, chemical and electric thruster plumes, vacuum venting, and visiting vehicle interactions have been developed by the Gateway Induced Environments team to ensure vehicle performance and mission success. The external contamination requirements and integration process are described along with required data deliverables. Integrated external contamination analyses are conducted by the Gateway Environments Team to assess compliance with external contamination requirements. This paper provides a current status of integration activities and analysis results, as well as future plans to improve external contamination characterization.

thruster plumes↗

The V-3 contamination test of the chamber A facility and a subsequent cryogenic/vacuum study of the V-3 test quartz crystal microbalance

The areas of orbital and ground contamination of flight experiment hardware have been well established. This report relates directly to results of vacuum chamber testing for the ground evaluation of flight experiment hardware performance. First, the data obtained during the V-3 contamination testing in the Johnson Space Center's Chamber A space simulation test facility are presented. Second, during the V-3 contamination tests, the MSFC Space Sciences Laboratory's quartz crystal microbalance exhibited two periods of anomalous readings. Therefore, a subsequent small chamber tests was conducted in a controlled cryogenic/vacuum environment. The objective was to reproduce with known parameters the anomalous behavior patterns of the V-3 test data. Analyses of the anomalous readings are made on the basis of these tests. Additionally, as a by-product of the small chamber tests, calibration curves then existing for the quartz crystal microbalance were empirically extended, and certain data-formatting aids were documented.

Moore, W. W., Jr.↗

Flight evidence of spacecraft surface contamination rate enhancement by spacecraft charging obtained with a quartz crystal microbalance

The significance of the fraction of the mass outgassed by a negatively charged space vehicle which is ionized within the vehicle plasma sheath and electrostatically reattracted to the space vehicle was determined. The ML-12 retarding potential analyzer/temperature controlled quartz crystal microbalances (RPA/TQCMs) distinguishes between charged and neutral molecules and investigates contamination mass transport mechanism. Two long term, quick look flight data sets indicate that on the average a significant fraction of mass arriving at one RPA/TQCM is ionized. It is assumed that vehicle frame charging during these periods was approximately uniformly distributed in degree and frequency. It is shown that electrostatic reattraction of ionized molecules is an important contamination mechanism at and near geosynchronous altitudes.

Clark, D. M.↗