Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Characterization and Failure Analysis of 650-V Enhancement-Mode GaN HEMT for Cryogenically Cooled Power Electronics

In order to evaluate the feasibility of newly developed gallium nitride (GaN) devices in a cryogenically cooled converter, this article characterizes a 650-V enhancement-mode GaN high-electron mobility transistor (GaN HEMT) at cryogenic temperatures. The characterization includes both static and dynamic behaviors. The results show that this GaN HEMT is an excellent device candidate to be applied in cryogenic-cooled applications. For example, transconductance at cryogenic temperature (93 K) is 2.5 times higher than one at room temperature (298 K), and accordingly, peak di / dt during turn-on transients at cryogenic temperature is around 2 times of that at room temperature. Moreover, the ON-resistance of the channel at the cryogenic temperature is only one-fifth of that at room temperature. The corresponding explanations of performance trends at cryogenic temperatures are also given from the view of semiconductor physics. In addition, several device failures were observed during the dynamic characterization of GaN HEMTs at cryogenic temperatures. Additionally, the ultrafast switching speed-induced high di / dt and dv / dt at cryogenic temperatures amplify the negative effects of parasitics inside the switching loop. Based on failure waveforms, two failure modes were classified, and detailed failure mechanisms caused by ultrafast switching speed are given in this article.

42 ENGINEERING↗

A Compact Cryogenic Environment for In Situ Neutron Diffraction Under Mechanical Loading

Understanding the deformation mechanisms of materials at cryogenic temperatures is crucial for cryogenic engineering applications. In situ neutron diffraction is a powerful technique for probing such mechanisms under cryogenic conditions. In this study, we present the development of a compact cryogenic environment (CCE) designed to facil-itate in situ neutron diffraction experiments under mechanical loading at tempera-tures as low as 77 K. The CCE features a polystyrene foam cryogenic chamber, alumi-num blocks serving as neutron-transparent cold sinks, a liquid nitrogen dosing system for cryogen delivery, a nitrogen gas flow control system for thermal management, a process controller for temperature control, and a pair of thermally isolated grip adapt-ers for mechanical testing. The CCE achieves reliable temperature control with mini-mal neutron attenuation. Utilizing this setup, we conducted three in situ neutron dif-fraction tensile tests on a 316L stainless steel at 77 , 173 , and 298 K, respectively. The results highlight the pronounced effects of cryogenic temperatures on the material's deformation mechanisms, underscoring both the significance of cryogenic deformation studies and the effectiveness of the CCE.

Yu, Dunji [ORNL] (ORCID:0000000189467851)↗

Warm Compressor system Overview and status of the PIP-II cryogenic system

The Proton Improvement Plan-II (PIP-II) is a major upgrade to the Fermilab accelerator complex, featuring a new 800-MeV Superconducting Radio-Frequency (SRF) linear accelerator (Linac) powering the accelerator complex to provide the world's most intense high-energy neutrino beam. The PIP-II Linac consists of 23 SRF cryomodules operating at 2 K, 5 K, and 40 K temperature levels supplied by a single helium cryoplant providing 2.5 kW of cooling capacity at 2.0 K. The PIP-II cryogenic system consists of two major systems: a helium cryogenic plant and a cryogenic distribution system. The cryogenic plant includes a refrigerator cold box, a warm compressor system, and helium storage, recovery, and purification systems. The cryogenic distribution system includes a distribution box, intermediate transfer line, and a tunnel transfer line consisting of modular bayonet cans which supply and return cryogens to the cryomodules. A turnaround can is located at the end of the Linac to turnaround cryogenic flows. This paper describes the layout, design, and current status of the PIP-II cryogenic system.

43 PARTICLE ACCELERATORS↗

Cryogenic Treatment of CoCrFeMnNi(NbC) High-Entropy Alloys

The effect of cryogenic treatment on the microstructure and mechanical properties of CoCrFeMnNi and CoCrFeMnNi(NbC) high-entropy alloys was investigated during annealing. The heat-treated samples were characterized by optical microscopy, scanning electron microscopy–wavelength-dispersive x-ray spectroscopy, x-ray diffraction technique, differential scanning calorimetry, Vickers hardness testing and tensile testing. The results showed a single-phase FCC crystal structure matrix in both alloys during cryogenic treatment and annealing. Cryogenic treatment altered the recrystallization behavior of CoCrFeMnNi high-entropy alloy, while it did not influence the recrystallization of CoCrFeMnNi(NbC) high-entropy alloy. It was also found that cryogenic treatment changed the precipitation behavior of CoCrFeMnNi(NbC) high-entropy alloy during annealing. In both studied high-entropy alloys, the mechanical testing indicated that the cryogenic treatment can effectively reduce the yield strength of cold-rolled samples after annealing. This was primarily attributed to the effect of cryogenic treatment in enhancing crystalline defects annihilation. Furthermore, the cryogenic treatment increased the ultimate tensile strength of CoCrFeMnNi(NbC). A lager plastic deformation and precipitates were considered as the main reasons for the higher ultimate tensile strength.

36 MATERIALS SCIENCE↗

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 1 – Steady state modeling and speed ratio selection

Helium cryogenic systems which can provide cooling below the normal boiling point of helium (approximately 4.2 K) are often required by superconducting radio-frequency niobium resonators utilized in modern high-energy particle accelerators. Achieving temperatures below 4.2 K generally involves operating a cryogenic vessel with liquid helium under sub-atmospheric conditions, thereby lowering the saturation pressure and corresponding saturation temperature. Over the last several decades, multi-stage cryogenic centrifugal compressor trains (CC’s) have been operated efficiently and reliably within large-scale cryogenic systems to continuously evacuate helium vapor generated by a device within the vessel, maintaining sub-atmospheric conditions in the vessel while pressurizing the return vapor to above atmospheric conditions. Traditionally, these CC systems have been operated using empirically derived control philosophies and insight gathered from previous operational experience. Recent efforts at the Facility for Rare Isotope Beams (FRIB) have been aimed at the development of a theoretical basis to characterize the operation of multi-stage cryogenic centrifugal compressor train and utilizing predictive model results to generate control parameters. The objective of this research was identifying operational points which adequately balance cryogenic system efficiency, stability, and overall ease of operation. Furthermore, this manuscript provides an overview of the predictive model development, characterization of the FRIB cryogenic centrifugal compressors and implementation of the predicted performance results during steady-state system operation.

Compressor train control↗

Design of the DUNE APATF cryogenic system

Fermi National Accelerator Laboratory (FNAL) is developing the international Long- Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) to advance neutrino science. The flagship of the DUNE project consists of a large particle detector constructed one-mile (1.6 km) beneath the surface at the Sanford Underground Research Facility (SURF) in Lead, SD. The SURF detector is the largest of its type ever built and is comprised of four cryostats totaling 70,000 tons of liquid argon (LAr) to record neutrino interactions with unprecedented precision. Each cryostat houses a detector, the first includes 150 Anode Panel Assemblies (APA) submersed within 17,500 tons of LAr. Before installing 150 APA within the SURF detector they will be cryogenically cooled to nominally 90 K at the APA Test Facility (APATF) utilizing nitrogen flows. The APATF cryogenic system is entirely located one-mile underground at the SURF facility and includes nominally 13 kW of refrigeration at 80 K, cryogenic transfer lines, APA test cryostats, a cryogenic control system, and various control and pressure safety elements to ensure performance and safety requirements are achieved. The APATF preliminary design is in progress and major considerations include an efficient, costeffective mechanism to deliver the required refrigeration to the APATF underground, support of rigid testing intervals to support the DUNE operating schedule, temperature stability of the APA and electronics within cryostats, efficient cryogenic system operation to minimize heat leak and/or liquid nitrogen consumption, thermo-mechanical stability and flexibility of components, and pressure safety of the APATF cryogenic system. Installation and integration of the APATF cryogenic system within the footprint and to adjacent sub-systems is also discussed.

43 PARTICLE ACCELERATORS↗

Cryogenic aspects of a 20 MW class low-temperature superconducting generator for the renewables industry

In this paper we give a progress update on the cryogenic design for cooling a 20 MW class, partially superconducting generator with stationary field coils for offshore wind renewables industry [1-2]. This is a continuation of an earlier program on a 10 MW system dating back ten years. Whereas this new power rating increase leads to a radial diameter expansion of the superconducting field coils from 4 to > 9.5 m, it maintains the axial length. We show the design based on this scaled up with enlarged diameter. The field coil size increase asks for higher cooling power that leads to a bigger cold box size to accommodate the cryocoolers. In the design, as many as 8 cryocoolers can be accessed and serviced from the nacelle that houses the main cryogenic components. A typical thermal load balance sheet with all components is given and compared against the available cryocooler cooling power at different operating conditions. Due to the cryocoolers’ local point of contact cooling within the nacelle, the temperature gradient of the thermal shield that fully encloses the cold mass with its embedded field coils needs to be balanced out to minimize the heat burden on the field coils. This requires additional analytical efforts and implementation of further design features. The extended nacelle houses the cold box with its cryogenic infrastructure. The interface for the envisaged cryogenic pushbutton closed-loop circulating system remains invisible, requires no handling of cryogenic liquids and is hermetically closed. The field coil diameter increase also leads to a greater initial helium gas storage volume. In addition, it requires higher initial room temperature fill pressure within the toroidal helium vapor storage tanks and in cooling tubes connecting to the cryocoolers. The toroidal helium gas tanks are thermally coupled with the thermal shield so that helium convection inside the storage tank can improve heat transfer and reduce the temperature gradient of the thermal shield. Besides those heat transfer challenges, additional mechanical strain within this large structure is exerted on the torque tubes during initial cooldown and when energizing field coils. Some of those design challenges are quite unexpected, leading to novel workarounds in order to maintain the chosen cooling strategy. Finally, we assess those design limitations in view of further cryogenic scalability with emphasis on manufacturability and assembly.

cryogenics↗

Design and Fabrication of the Mu2e Cryogenic Distribution System

The muon-to-electron conversion (Mu2e) experiment at Fermilab will be used to search for the charged lepton flavor-violating conversion of muons to electrons in the field of an atomic nucleus. The Mu2e experiment is currently in the design and construction stage and is expected to begin operations in 2022. The Mu2e experiment uses four large superconducting solenoid magnets including a Production Solenoid (PS), an Upstream and Downstream Transport Solenoid (TSu and TSd) and a Detector Solenoid (DS). This paper will focus on the cryogenic distribution system for these four solenoid magnets. Liquid helium will be supplied from two re-purposed Tevatron satellite refrigerators. A large cryogenic distribution box (DB) is located in the Mu2e building to distribute the required cryogens to each of the four solenoid magnets. Each solenoid magnet will have a dedicated transfer line and cryogenic feed box (FB). The solenoid magnets each require two liquid helium circuits and two liquid nitrogen circuits. The most unique feature about this cryogenic system is that the assemblies for the start of the superconducting portion of the power leads are mounted in feed boxes that are in the range of 23 m to 31 m away from the solenoid magnets. The cryogenic feed boxes are located remotely to provide protection from radiation damage and high magnetic fields. The power leads are NbTi superconducting cable stabilized with high conductivity aluminum. The 6061-T6 aluminum grade was selected for the transfer line piping so that the piping would thermally contract at the same rate as the power lead. A major concern for this transfer line is that a small helium leak could create an electric discharge arc due to the Paschen effect. This paper includes a description of the design features and testing done to ensure that the power leads are protected from the Paschen effect while still being adequately cooled to liquid helium temperatures.

43 PARTICLE ACCELERATORS↗

In Situ X-Ray Diffraction Analysis of Face-Centered Cubic Metals Deformed at Room and Cryogenic Temperatures

The present study concerns the cryogenic processing of metals with simultaneous analysis of x-ray diffraction in a synchrotron ring. The mechanical properties improvement related to cryogenic processing of metals is attributed to the partial suppression of dynamic recovery. Thus, commercially pure metals with different stacking fault energies (silver, copper and aluminum) were deformed by uniaxial tensile tests and characterized by in situ x-ray diffraction, at room (293 K) and cryogenic (77 K) temperatures. The cryogenic processing allows a simultaneous improvement in ductility and strength for silver and copper and an improvement in strength for aluminum. This difference in mechanical properties was investigated by means of variations in crystallite size, microstrain and also the amount and size of dimples on the fracture surface. The microstructural refinement at cryogenic temperatures shows a tendency related to the stacking fault energies.

36 MATERIALS SCIENCE↗

Impact of Cryogenic Treatment on Mechanical Behavior and Microstructure of Ti-6Al-4V ELI Biomaterial

Ti-6Al-4V with its ELI variant is a potential biomaterial for structural implants. However, its poor resistance to plastic shearing results in poor tribological properties that hinders its widespread use in biomedical implants. Cryogenic treatment being an established technique for improving wear resistance and other mechanical properties of ferrous materials is applied on Ti-6Al-4V ELI alloy. To ensure comprehensive investigations, the widely studied microstructures of Ti-6Al-4V ELI, i.e., lamellar, martensite, two variants of bimodal and mill annealed are considered in this work. Deep cryogenic treatment at the soaking temperature (− 196 °C) for 24 h soaking time followed by tempering has been applied. The impact of cryogenic treatment has been assessed in terms of changes in the mechanical behavior including wear resistance, hardness, tensile properties and impact strength. The alterations in mechanical behavior due to cryogenic treatment are correlated with microstructure evolution. Cryogenic treatment has caused significant improvement in mechanical behavior of Ti-6Al-4V ELI alloy.

36 MATERIALS SCIENCE↗

Cryogenic Stress-Driven Grain Growth Observed via Microcompression with in situ Electron Backscatter Diffraction

The deformation of materials at cryogenic temperature is of interest for space, arctic, and fundamental science applications. In this work, a custom-built cooling system attached to a commercial picoindenter was used for in situ cryogenic microcompression testing of equal-channel angular-pressed copper with real-time electron backscatter diffraction. Stress-driven grain growth at cryogenic temperatures was observed during a series of elastic and plastic deformations. Finally, these results provide direct evidence for the previously predicted phenomenon, whereas previous ex situ examinations demonstrated coarsening after cryogenic loading when samples were not maintained at cryogenic temperatures between deformation and characterization.

36 MATERIALS SCIENCE↗

Ultralow-temperature cryogenic transmission electron microscopy using a new helium flow cryostat stage

Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL (Scanning) Transmission Electron Microscopes (S/TEM), utilizing compressed liquid helium (LHe) and designed for imaging and spectroscopy at ultra-low temperatures. The system includes an external dewar mounted on a vibration-damping stage and a pressurized, low-noise helium transfer line with a remotely controllable needle valve, ensuring stable and efficient LHe flow with minimal thermal and mechanical noise. Performance evaluation demonstrates a stable base temperature of 4.37 K measured using a Cernox bare chip sensor on the holder with temperature fluctuations within ±0.004 K. Complementary in-situ electron energy-loss spectroscopy (EELS) via aluminum bulk plasmon analysis was used to measure the local specimen temperature and validate cryogenic operation during experiments. The integration of cryogenic cooling with other microscopy techniques, including electron diffraction and Lorentz TEM, was demonstrated by resolving charge density wave (CDW) transitions in NbSe2 using electron diffraction, and imaging nanometric magnetic skyrmions in MnSi via Lorentz TEM. In conclusion, this platform provides reliable cryogenic operation below 7 K, establishing a low-drift route for direct visualization of electronic and magnetic phase transformations in quantum materials.

Charge density wave↗

Injection locking and coupling dynamics in superconducting nanowire-based cryogenic oscillators

Oscillators designed to function at cryogenic temperatures play a critical role in superconducting electronics and quantum computing by providing stable, low-noise signals with minimal energy loss. Here, in this work, we present a comprehensive numerical study of injection locking and mutual coupling dynamics in superconducting nanowire (ScNW)-based cryogenic oscillators. Using the design space of a standalone ScNW-based oscillator, we investigate two critical mechanisms that govern frequency synchronization and signal coordination in cryogenic computing architectures: (1) injection locking induced by an external AC signal with a frequency near the oscillator's natural frequency, and (2) the mutual coupling dynamics between two ScNW oscillators under varying coupling strengths. We identify key design parameters—such as shunt resistance, nanowire inductance, and coupling strength—that govern the locking range. Additionally, we examine how the amplitude of the injected signal affects the amplitude of the locked oscillation, offering valuable insights for power-aware oscillator synchronization. Furthermore, we analyze mutual synchronization between coupled ScNW oscillators using capacitive and resistive coupling elements. Our results reveal that the phase difference between oscillators can be controlled by tuning the coupling strength, enabling programmable phase-encoded information processing. These findings could enable building ScNW-based oscillatory neural networks, synchronized cryogenic logic blocks, and on-chip cryogenic resonator arrays.

Artificial neural networks↗

Temperature and Strain Sensing Characteristics of a 128° YX-Cut LiNbO 3 Rayleigh-Mode SAW Sensor From Room to Cryogenic Temperatures

Accurate, passive, and wireless monitoring of cryogenic hardware is essential for high-energy physics, space propulsion, and biomedical instrumentation. Here, this study quantifies the coupled temperature-strain behavior of Rayleigh-mode surface acoustic-wave (SAW) delay-line sensors fabricated on 128° YX-cut LiNbO 3 . A nonlinear finite element (FE) model incorporating Varshni-based elastic constants, higher-order thermal expansion, and temperature-dependent piezo- and dielectric coefficients was developed and validated experimentally between 280K and 80K. Free-standing (first test condition) and bonded/wired (second test condition) devices exhibited indistinguishable thermal responses; the average temperature coefficient of delay (TCD) in the critical cryogenic range from 130K down to 80K differed by only 0.15 ppm/K (0.32%), confirming that bonding-induced stress is negligible. Over 280-80K the measured TCD was 61.77 ppm/K, while the FE model predicted an equivalent temperature coefficient of frequency (TCF) of −62.74 ppm/K with an overall coefficient of determination R2 = 0.998. In the critical cryogenic interval 130-80K the TCD fell to 47.66 ppm/K, indicating improved thermal stability at low temperature. Controlled loading (0-300 με) revealed a strain coefficient of delay (SCD) that rises from 0.53 ± 0.02 ppm/με at 300K to 1.05 ± 0.02 ppm/με at 80K. This modest sensitivity confirms that, for temperature sensing, strain is a second-order perturbation above 135K but must be compensated at deeper cryogenic levels. Overall, this work establishes a predictive multiphysics model together with repeatable wired measurements that confirm the suitability of SAW sensors for temperature and strain monitoring in extreme cryogenic environments, while also providing a baseline for future wireless implementations.

25 ENERGY STORAGE↗

Cryogen Safety Live #8876

Cryogenics (from the Greek word κρυος, meaning frost or icy cold) is the study of the effects and behavior of materials at very low temperature. This course is designed to provide trainees with an introduction to cryogen use, hazards associated with cryogen systems, cryogen safety components, and the requirements that govern the design and use of cryogen systems at Los Alamos National Laboratory (LANL). The knowledge you gain is intended to help you keep your workplace safe for you and your coworkers.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Cryogenic Liquid Jets for High Repetition Rate Discovery Science

In this paper, we present a detailed procedure for the operation of continuous, micron-sized cryogenic cylindrical and planar liquid jets. When operated as described here, the jet exhibits high laminarity and stability for centimeters. Successful operation of a cryogenic liquid jet in the Rayleigh regime requires a basic understanding of fluid dynamics and thermodynamics at cryogenic temperatures. Theoretical calculations and typical empirical values are provided as a guide to design a comparable system. This report identifies the importance of both cleanliness during cryogenic source assembly and stability of the cryogenic source temperature once liquefied. The system can be used for high repetition rate laser-driven proton acceleration, with an envisioned application in proton therapy. Other applications include laboratory astrophysics, materials science, and next-generation particle accelerators.

42 ENGINEERING↗

Dispersion of cryogenic hydrogen through high-aspect ratio nozzles

Liquid hydrogen is increasingly being used as a delivery and storage medium for stations that provide compressed gaseous hydrogen for fuel cell electric vehicles. In efforts to provide scientific justification for separation distances for liquid hydrogen infrastructure in fire codes, the dispersion characteristics of cryogenic hydrogen jets (50–64 K) from high aspect ratio nozzles have been measured at 3 and 5 bar abs stagnation pressures. These nozzles are more characteristic of unintended leaks, which would be expected to be cracks, rather than conventional round nozzles. Spontaneous Raman scattering was used to measure the concentration and temperature field along the major and minor axes. Within the field of interrogation, the axis-switching phenomena was not observed, but rather a self-similar Gaussian-profile flow regime similar to room temperature or cryogenic hydrogen releases through round nozzles. The concentration decay rate and half-widths for the planar cryogenic jets were found to be nominally equivalent to that of round nozzle cryogenic hydrogen jets indicating a similar flammable envelope. The results from these experiments will be used to validate models for cryogenic hydrogen dispersion that will be used for simulations of alternative scenarios and quantitative risk assessment.

08 HYDROGEN↗

Fermilab Cryogenic Test Facilities

Fermi National Accelerator Laboratory (Fermilab) has multiple cryogenic test facilities, undertaking testing of superconducting magnets, Superconducting Radio Frequency (SRF) cavities, SRF cryomodules and other helium cryogenic components. The test areas within Fermilab include: Meson Cryogenic Test facility (Meson), Industrial Building 1 (IB-1), Heavy Assembly Building/Illinois Accelerator Research Center (HAB/IARC), New Muon Lab, (NML) and the Cryomodule Test Facility (CMTF). Meson and HAB/IARC utilize repurposed Tevatron era reciprocating engine based cryogenic refrigerator systems, whereas CMTF and IB-1 utilize gas bearing turbine based coldboxes. Each of these test areas support the various Fermilab projects and collaborations including the Linear Coherent Light Source II (LCLS-II), Proton Improvement Plan II (PIP-II), High Luminosity Large Hadron Collider (HL-LHC), and Mu2e. This paper outlines the diverse and extensive cryogenic test capabilities within Fermilab.

43 PARTICLE ACCELERATORS↗