Bipropellant droplet combustion in the vicinity of the critical point
High pressure bipropellant droplet combustion efficiency near critical point
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
High pressure bipropellant droplet combustion efficiency near critical point
A description of the experimental approach for performing critical point measurements is discussed and results of ground based measurements in preparation for the flight experiment are presented.
Taylor series expansion in powers of deviation from critical point for integral thermodynamic functions
The singular points in steady state, field-aligned plasma transport models based on velocity moment theory are examined. In particular, two separate singular points in the equations obtained from the 16-moment approximation are identified. These equations are presented in a form that makes the singularities apparent, and they are solved in a simple illustrative case. The singular points, one occurring at the sonic point and the other at a critical value of the parallel heat flux, give rise to different outflow regimes, characterized generically by different asymptotic behavior. The existence of the different outflow regimes separated by the heat flux critical point has been only hinted at in previous discussions of numerical simulation of the polar wind.
LF sound velocity measurement in carbon dioxide near critical point, noting existence of logarithmic divergence
Preliminary results for the Critical Point Wetting CPW Drop Tower Experiment are produced with immiscible systems. Much of the observed phenomena conformed to the anticipated behavior. More drops will be needed to test the CPW theory with these immiscible systems.
The objective of this program is to observe the interface shape in single and multicomponent systems at the onset of critical wetting in microgravity using the MSFC drop tower and KC-135 aircraft. Test cells for the drop facility were built and tested up to critical point of CCl. Low temperature drops were conducted for two-component systems near the critical consolute point. Contact angle seems to approach 90 deg near the critical consolute temperature contrary to expectations. It is suspected that since the interfacial energy becomes vanishingly small at the critical consolute temperature, the interface shape has not reached equilibrium in the available low-gravity time.
An electrostriction method was used to determine the susceptibility along the critical isochore near the liquid-gas critical point of 3He.
Bipropellant droplet supercritical steady combustion temperature measurements in zero gravity near critical point, comparing high and low pressures models for ambient gas solubility
Faraday effect for magnetic properties of chromium tribromide along various isotherms near critical point, confirming scaling laws
Large gravity induced density gradients present in ground-based experiments prevent an unambiguous test of universality and scaling predictions near the liquid-gas critical point.
NASA is supporting the development of an experiment called MISTE (Microgravity Scaling Theory Experiment) for future International Space Station mission. The main objective of this flight experiment is to perform in-situ PVT, heat capacity at constant volume, C(sub v) and chi(sub tau), measurements in the asymptotic region near the (sup 3)He liquid-gas critical point.
Thermodynamic data from interferometric density profile studies and light-scattering experiments near the critical isochore of Xe, CO2 and SF6 provide a basis for examining the hypothesized two-scale-factor universality for the correlation function of fluids near the gas-liquid critical point. For the investigation, three-scale-factor universality is assumed, with Ising-like critical exponent values obtained through the renormalization group technique. The two thermodynamic scale factors are found from the density profiles, while the scale factor for the correlation length is obtained from the light-scattering data.
We measured shear thinning, a viscosity decrease ordinarily associated with complex liquids, near the critical point of xenon. The data span a wide range of reduced shear rate: 10(exp -3) < gamma-dot tau < 700, where gamma-dot tau is the shear rate scaled by the relaxation time tau of critical fluctuations. The measurements had a temperature resolution of 0.01 mK and were conducted in microgravity aboard the Space Shuttle Columbia to avoid the density stratification caused by Earth's gravity. The viscometer measured the drag on a delicate nickel screen as it oscillated in the xenon at amplitudes 3 mu,m < chi (sub 0) >430 mu, and frequencies 1 Hz < omega/2 pi < 5 Hz. To separate shear thinning from other nonlinearities, we computed the ratio of the viscous force on the screen at gamma-dot tau to the force at gamma-dot tau approximates 0: C(sub gamma) is identical with F(chi(sub 0), omega tau, gamma-dot tau )/F)(chi(sub 0, omega tau, 0). At low frequencies, (omega tau)(exp 2) < gamma-dot tau, C(sub gamma) depends only on gamma-dot tau, as predicted by dynamic critical scaling. At high frequencies, (omega tau)(exp 2) > gamma-dot tau, C(sub gamma) depends also on both x(sub 0) and omega. The data were compared with numerical calculations based on the Carreau-Yasuda relation for complex fluids: eta(gamma-dot)/eta(0)=[1+A(sub gamma)|gamma-dot tau|](exp - chi(sub eta)/3+chi(sub eta)), where chi(sub eta) =0.069 is the critical exponent for viscosity and mode-coupling theory predicts A(sub gamma) =0.121. For xenon we find A(sub gamma) =0.137 +/- 0.029, in agreement with the mode coupling value. Remarkably, the xenon data close to the critical temperature T(sub c) were independent of the cooling rate (both above and below T(sub c) and these data were symmetric about T(sub c) to within a temperature scale factor. The scale factors for the magnitude of the oscillator s response differed from those for the oscillator's phase; this suggests that the surface tension of the two-phase domains affected the drag on the screen below T(sub c).
We present high-resolution measurements of the isothermal susceptibility of pure 3He near the liquid-gas critical point.
A new electrostriction technique was developed to measure the isothermal compressibility along isochores and isotherms near the critical point. Initial measurements that validate this new technique will also be presented.
Explore the source record for details and available documents.
Numerical solutions of boundary layer equations for noncompressible pseudoplastic fluids on permeable flat plate and in vicinity of critical point