Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coordinated operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Solar and Storage Integration in the Southeastern United States: Economics, Reliability, and Operations

Solar energy has the potential to be a core energy resource for the southeastern United States. To better understand the implications of higher levels of solar PV (27%-43% of total generation capacity) and electricity storage (13%-49% of peak load) would affect electricity system reliability, costs, and operations in the U.S. Southeast, this study sought to address two main questions. First, how would higher levels of solar PV and electricity storage impact the costs, reliability, and operations of electricity systems in the Southeast in 2035? Second, at different levels of solar PV and electricity storage, what are the benefits of operational coordination among utilities in the Southeast, through more efficient regional dispatch and sharing operating reserves? To answer these questions, the study used detailed capacity expansion and dispatch modeling to develop and examine 15 scenarios with different levels of solar PV, electricity storage, and operational coordination, focusing on the year 2035. The study also evaluates the benefits of operational coordination among utilities through more efficient regional dispatch and reserve sharing, at different levels of solar and storage. The study focuses on five balancing regions that cover Alabama, Georgia, Kentucky, North Carolina, South Carolina, Tennessee, and parts of Mississippi and Missouri.

14 SOLAR ENERGY↗

Solar and Storage Integration in the Southeastern United States: Economics, Reliability, and Operations

Solar energy has the potential to be a core energy resource for the southeastern United States. To better understand the implications of higher levels of solar PV (27%-43% of total generation capacity) and electricity storage (13%-49% of peak load) would affect electricity system reliability, costs, and operations in the U.S. Southeast, this study sought to address two main questions. First, how would higher levels of solar PV and electricity storage impact the costs, reliability, and operations of electricity systems in the Southeast in 2035? Second, at different levels of solar PV and electricity storage, what are the benefits of operational coordination among utilities in the Southeast, through more efficient regional dispatch and sharing operating reserves? To answer these questions, the study used detailed capacity expansion and dispatch modeling to develop and examine 15 scenarios with different levels of solar PV, electricity storage, and operational coordination, focusing on the year 2035. The study also evaluates the benefits of operational coordination among utilities through more efficient regional dispatch and reserve sharing, at different levels of solar and storage. The study focuses on five balancing regions that cover Alabama, Georgia, Kentucky, North Carolina, South Carolina, Tennessee, and parts of Mississippi and Missouri.

14 SOLAR ENERGY↗

Coordinating an operational data distribution network for CMIP6 data

The distribution of data contributed to the Coupled Model Intercomparison Project Phase 6 (CMIP6) is via the Earth System Grid Federation (ESGF). The ESGF is a network of internationally distributed sites that together work as a federated data archive. Data records from climate modelling institutes are published to the ESGF and then shared around the world. It is anticipated that CMIP6 will produce approximately 20 PB of data to be published and distributed via the ESGF. In addition to this large volume of data a number of value-added CMIP6 services are required to interact with the ESGF; for example the citation and errata services both interact with the ESGF but are not a core part of its infrastructure. With a number of interacting services and a large volume of data anticipated for CMIP6, the CMIP Data Node Operations Team (CDNOT) was formed. The CDNOT coordinated and implemented a series of CMIP6 preparation data challenges to test all the interacting components in the ESGF CMIP6 software ecosystem. This ensured that when CMIP6 data were released they could be reliably distributed.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Adaptive Load Shedding as Part of Primary Frequency Response To Support Networked Microgrid Operations

Global changes in the deployment of distributed energy resources, control and communications technologies, business models, and regulatory policy are increasing the operational options for future distribution systems. One such option is the coordinated operation of distributed resources to form microgrids and networks of microgrids to support traditional bulk power systems during normal operations and critical end-use loads during outages. While individual standalone microgrids have been extensively studied and deployed, the coordinated operation of networked microgrids is operationally more challenging due to the dynamic boundaries and changing mix of generation resources. Here, this paper presents a method of using a distributed control architecture to support primary frequency response in networked microgrids operations. The support of primary frequency response is accomplished using the Open Field Message Bus reference architecture and Grid Friendly Appliance controllers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices: Preprint

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Neural Networks-Based Inverter Control: Modeling and Adaptive Optimization for Smart Distribution Networks

The optimal voltage control of inverter-based resources, especially under the high penetration of solar photovoltaics, is critical to the stability of the distribution power system. However, the computational complexity as well as the coordinated operation performance of the voltage control optimization in the distribution power system limits the real-time applications. To mitigate this issue, a model-free based adaptive optimal control scheme for the smart inverter is proposed to maximize the active power generation, minimize the power loss, and maintain the bus voltages in smart distribution networks. An inverter-based optimization model for coordinated operation is first established, considering the uncertainties of renewable power generation. Subsequently, by collecting the data and control strategies, the neural networks (NNs) based algorithm is proposed to efficiently predict the best possible control strategy. The main objective of this scheme is to accurately predict candidate optimal solutions with near-negligible feasibility and optimization gaps, with the advantage of avoiding complicated iteration-based numerical algorithms. Thereafter, the co-simulation among OpenDSS, MATLAB, and Python is set up to fully take advantage of the three individual software. Experiments are conducted based on different control parameter characteristics and structures of NNs. Finally, the results reveal that an average mean squared error of 0.013 and 1 ms response time are achieved, which is lower than some state-of-the-art methods.

42 ENGINEERING↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources: Preprint

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS—based on real-time optimal power flow—controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

61 RADIATION PROTECTION AND DOSIMETRY↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS-based on real-time optimal power flow-controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time Hardware-in-the-Loop Evaluation of a Partially Turboelectric Propulsion Control Design

In support of aviation fuel burn and emission reduction goals, NASA is pursuing high-payoff research investments that promise to transform aviation. This includes investments in Electrified Aircraft Propulsion (EAP). Multiple technology challenges must be addressed to unlock the full potential of EAP. This includes addressing challenges related to propulsion controls, which will be vital for ensuring efficient coordinated operation of EAP subsystems. This paper presents results from real-time hardware-in-the-loop testing of a control design for a single aisle partially-turboelectric aircraft propulsion concept conducted at the NASA Electric Aircraft Testbed (NEAT) facility. The control system under test is designed for a propulsion concept consisting of two wing-mounted turbofan engines that produce thrust and generate electrical power to drive a boundary layer ingesting tailfan propulsor via an electrical motor. An integrated control strategy is applied to ensure coordinated operation of the turbofan and tailfan subsystems during steady-state and transient operation throughout the flight envelope. The NEAT test of this integrated control design consists of a partially hardware-in-the-loop, partially simulated configuration. A subscale representation of the electrical system design is implemented in hardware and mechanically coupled to electric machines that emulate turbomachinery and propulsor shaft dynamics. The hardware configuration is then operated under the control of a real-time computer application that runs a simulation of the propulsion system and the developed control logic. The NEAT facility test campaign includes a series of experiments that subject the control design to throttle transients conducted throughout the flight envelope and full-flight mission profiles. Testing under simulated performance degradation is also conducted to evaluate control design robustness. This includes constant and abrupt changes in degradation levels. Results from the hardware-in-the-loop test are presented and shown to be in good agreement with pre-test simulation predictions demonstrating the efficacy of the integrated control design approach.

Electrified Aircraft Propulsion↗

Real-time Hardware-in-the-Loop Evaluation of a Partially Turboelectric Propulsion Control Design

In support of aviation fuel burn and emission reduction goals, NASA is pursuing high-payoff research investments that promise to transform aviation. This includes investments in Electrified Aircraft Propulsion (EAP). Multiple technology challenges must be addressed to unlock the full potential of EAP. This includes addressing challenges related to propulsion controls, which will be vital for ensuring efficient coordinated operation of EAP subsystems. This paper presents results from real-time hardware-in-the-loop testing of a control design for a single aisle partially-turboelectric aircraft propulsion concept conducted at the NASA Electric Aircraft Testbed (NEAT) facility. The control system under test is designed for a propulsion concept consisting of two wing-mounted turbofan engines that produce thrust and generate electrical power to drive a boundary layer ingesting tailfan propulsor via an electrical motor. An integrated control strategy is applied to ensure coordinated operation of the turbofan and tailfan subsystems during steady-state and transient operation throughout the flight envelope. The NEAT test of this integrated control design consists of a partially hardware-in-the-loop, partially simulated configuration. A subscale representation of the electrical system design is implemented in hardware and mechanically coupled to electric machines that emulate turbomachinery and propulsor shaft dynamics. The hardware configuration is then operated under the control of a real-time computer application that runs a simulation of the propulsion system and the developed control logic. The NEAT facility test campaign includes a series of experiments that subject the control design to throttle transients conducted throughout the flight envelope and full-flight mission profiles. Testing under simulated performance degradation is also conducted to evaluate control design robustness. This includes constant and abrupt changes in degradation levels. Results from the hardware-in-the-loop test are presented and shown to be in good agreement with pre-test simulation predictions demonstrating the efficacy of the integrated control design approach.

Electrified Aircraft Propulsion↗

Real-Time Hardware-in-the-Loop Evaluation of A Partially Turboelectric Propulsion Control Design

In support of aviation fuel burn and emission reduction goals, NASA is pursuing high-payoff research investments that promise to transform aviation. This includes investments in Electrified Aircraft Propulsion (EAP). Multiple technology challenges must be addressed to unlock the full potential of EAP. This includes addressing challenges related to propulsion controls, which will be vital for ensuring efficient coordinated operation of EAP subsystems. This paper presents results from real-time hardware-in-theloop (HIL) testing of a control design for a single aisle partially-turboelectric aircraft propulsion concept conducted at the NASA Electric Aircraft Testbed (NEAT) facility. The control system under test is designed for a propulsion concept consisting of two wing-mounted turbofan engines that produce thrust and generate electrical power to drive a boundary layer ingesting tailfan propulsor via an electrical motor. An integrated control strategy is applied to ensure coordinated operation of the turbofan and tailfan subsystems during steady-state and transient operation throughout the flight envelope. The NEAT test of this integrated control design consists of a partially HIL, partially simulated configuration. A subscale representation of the electrical system design is implemented in hardware and mechanically coupled to electric machines that emulate turbomachinery and propulsor shaft dynamics. The hardware configuration is then operated under the control of a real-time computer application that runs a simulation of the propulsion system and the developed control logic. The NEAT facility test campaign includes a series of experiments that subject the control design to throttle transients conducted throughout the flight envelope and full-flight mission profiles. Testing under simulated performance degradation is also conducted to evaluate control design robustness. This includes constant and abrupt changes in degradation levels. Results from the HIL test are presented and shown to be in good agreement with pretest simulation predictions demonstrating the efficacy of the integrated control design approach.

Electrified Aircraft Propulsion↗

A Data-Based Console Logger for Mission Operations Team Coordination

Concepts and prototypes1,2 are discussed for a data-based console logger (D-Logger) to meet new challenges for coordination among flight controllers arising from new exploration mission concepts. The challenges include communication delays, increased crew autonomy, multiple concurrent missions, reduced-size flight support teams that include multidisciplinary flight controllers during quiescent periods, and migrating some flight support activities to flight controller offices. A spiral development approach has been adopted, making simple, but useful functions available early and adding more extensive support later. Evaluations have guided the development of the D-Logger from the beginning and continue to provide valuable user influence about upcoming requirements. D-Logger is part of a suite of tools designed to support future operations personnel and crew. While these tools can be used independently, when used together, they provide yet another level of support by interacting with one another. Recommendations are offered for the development of similar projects.

Thronesbery, Carroll↗

Remote Infrared Imaging of the Space Shuttle During Hypersonic Flight: HYTHIRM Mission Operations and Coordination

The Hypersonic Thermodynamic Infrared Measurements (HYTHIRM) project has been responsible for obtaining spatially resolved, scientifically calibrated in-flight thermal imagery of the Space Shuttle Orbiter during reentry. Starting with STS-119 in March of 2009 and continuing through to the majority of final flights of the Space Shuttle, the HYTHIRM team has to date deployed during seven Shuttle missions with a mix of airborne and ground based imaging platforms. Each deployment of the HYTHIRM team has resulted in obtaining imagery suitable for processing and comparison with computational models and wind tunnel data at Mach numbers ranging from over 18 to under Mach 5. This paper will discuss the detailed mission planning and coordination with the NASA Johnson Space Center Mission Control Center that the HYTHIRM team undergoes to prepare for and execute each mission.

Schwartz, Richard J.↗

FERC order 2222 & DER policy and implementation report - January 2026

The January 2026 FERC 2222 Tracker Report provides an overview of the progress and challenges in the implementation of FERC Order 2222, emphasizing the critical need for state-level action to address gaps in DERA/EDC communication protocols. The report highlights the importance of reliable communication between electric distribution companies (EDCs) and DER aggregators (DERAs) for seamless market operations, noting the absence of specific directives from FERC and RTO/ISO compliance filings. Key discussions include the operational coordination required to manage DER operations within aggregated markets, the potential use of tools like DER Registries for efficient data exchange, and the implications of non-performance due to communication issues. While steps are being taken at the state level, such as ongoing policy development and bi-monthly webinars for stakeholder education, no states have fully developed coordination frameworks as of early 2026. The report underscores the growing role of states and local regulators in defining these protocols and ensuring effective coordination amidst the complex dynamics of distributed energy resources (DERs) integration into wholesale markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Track and capture of the orbiter with the space station remote manipulator system

Results of the first study using the real-time, man-in-the-loop Systems Engineering Simulator (SES) for track and capture of the Space Shuttle Orbiter with the space station manipulator are presented. The objectives include evaluation of the operational coordination required between the orbiter pilot and the space station manipulator operator, evaluation of the locations and required number of closed-circuit television cameras, and evaluation of the orbiter grapple fixture clearance geometry. The SES is a premium quality real-time facility with full fidelity orbiter and space station crew workstations and cockpits.

Bains, E. M.↗