Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An Overview of Non-LWR Vessel Cooling Systems for Passive Decay Heat Removal (Technical Letter Final Report)

The following report provides a technical review of various reactor vessel cooling system (VCS) concepts under consideration for decay heat removal (DHR) in non-light water advanced reactor designs. This review focuses on ex-vessel designs, including the Reactor Cavity Cooling System (RCCS), the Reactor Vessel Auxiliary Cooling System (RVACS), and hybrid iterations, using both air and water cooling to achieve their heat removal function. Based on a literature review of publicly available sources published between 1979 and 2021, a technical summary is presented detailing existing and planned VCS design options, their applicability to specific reactor type, and review of authored research and development studies. Following an assessment of the availability of data and modeling tools, an evaluation was performed analyzing their likely performance during normal, degraded, and accident conditions, including reliability, stability, and longevity. With renewed consideration of air-based DHR systems by some US vendors, there is a need to fully understand the complexities inherent to natural circulation systems, and more importantly, how they may influence safety-related heat removal functions and system performance. For DHR systems that rely on air-based mode of cooling, this entails quantification of the impacts of low flow conditions during start-up, relative elevations of inlet and outlet ducts for below-grade installations, effects of the use of multiple parallel chimneys for redundancy, and impact of weather conditions at the plant site. For systems relying on water-based mode cooling, reliance on limited coolant inventory in an event of pipe break or extended duration accident scenarios, sensitivities related to stability of boiling flow and heat transfer conditions, and quantification of full-scale structural vibrations on balance of plant structures are among the complicating factors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Adiabatic Cooling System Spreadsheet Model for sCO 2

The attached cost and performance spreadsheet model is for an adiabatic cooling system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO 2 (sCO 2 ) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

Thin hybrid capillary two-phase cooling system

A novel hybrid two-phase cooling system was developed that integrated a mechanically pumped two-phase loop with a capillary-driven two-phase cooling device. The latter cooling mechanism was based on evaporation/boiling from wick structures made by sintering copper particles on the interior surfaces of a copper cold plate. The cold plate provided cooling to two surfaces and each of them included four heaters in series. The novelty of the developed technology was preventing flooding of the evaporator wicks by isolating the evaporation surface from the pumped liquid flow that fed them. This arrangement allowed for a high liquid feed flow rate much greater than would be allowed by a capillary pumped system while maintaining a low thermal resistance at the evaporation surface. Using this approach, the cooling system removed over 850 W with a low pumping power below 1.0 W while using R245fa as the working fluid. The equivalent heat fluxes exceeded 970 W/cm 2 over areas less than 0.12 cm 2 . The measured thermal resistance was as low as 0.09 K-cm 2 /W. The presented thermal management solution enables an increase in the power of high heat flux electronic devices beyond the state-of-the-art.

42 ENGINEERING↗

Simulation-based assessment on stochastic load scheduling for building cooling systems

Here, to fill knowledge gaps related to stochastic load scheduling, we performed a comprehensive evaluation of the stochastic load scheduling for building cooling systems. Specifically, we studied the common uncertain variables in the load scheduling process for building cooling systems and categorized those variables based on their dynamic patterns. We then developed a generic stochastic load scheduling framework and applied it to building cooling systems that served a simulated community. This community consists of 100 heterogeneous houses and serves as a virtual testbed for evaluating the performance of stochastic load scheduling. In this evaluation, we considered representatives of uncertain variables with different dynamic patterns and included 100 realizations of the considered uncertainty in the evaluation to better catch the probability distribution of the control performance. The evaluation results suggest that deterministic load scheduling can reduce the operating energy cost by 18% but its performance can be affected by uncertainty. Stochastic load scheduling can further decrease the operating energy cost under uncertainty compared to deterministic load scheduling. We also found that the effectiveness of stochastic load scheduling in handling uncertainty is not directly associated with the number of uncertainty scenarios that are considered in its formulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adsorption cooling system using carbon aerogel

An adsorptive cooling system includes: a first highly adsorptive structure positioned to receive thermal energy from a thermal energy source, the first highly adsorptive structure including: a first substrate; and a first carbon aerogel adhered to the first substrate, a second highly adsorptive structure positioned to receive thermal energy from the thermal energy source, the second highly adsorptive structure including: a second substrate; and a second carbon aerogel adhered to the second substrate, a cooling unit; and a circulation system adapted for circulating the refrigerant from at least one of the first highly adsorptive structure and the second highly adsorptive structure to the cooling unit to provide cooling from the thermal energy source and to return the refrigerant from the cooling unit to at least one of the first highly adsorptive structure and the second highly adsorptive structure.

Baumann, Theodore F.↗

High-performance multimode elastocaloric cooling system

Developing zero–global warming potential refrigerants has emerged as one area that helps address global climate change concerns. Various high-efficiency caloric cooling techniques meet this goal, but scaling them up to technologically meaningful performance remains challenging. We have developed an elastocaloric cooling system with a maximum cooling power of 260 watts and a maximum temperature span of 22.5 kelvin. These values are among the highest reported for any caloric cooling system. Its key feature is the compression of fatigue-resistant elastocaloric nitinol (NiTi) tubes configured in a versatile multimode heat exchange architecture, which allows the harnessing of both high delivered cooling power and large temperature spans. Our system shows that elastocaloric cooling, which only emerged 8 years ago, is a promising direction for commercializing caloric cooling.

Science & Technology - Other Topics↗

Adsorption cooling system using metal organic frameworks

An adsorptive cooling system includes: a first highly adsorptive structure positioned to receive thermal energy from a thermal energy source, including: a first substrate; and a first metal-organic framework (MOF) coupled to the first substrate and adapted for adsorbing and desorbing a refrigerant under predetermined thermodynamic conditions; a second highly adsorptive structure positioned to receive thermal energy from the thermal energy source including: a second substrate; and a second MOF coupled to the second substrate and adapted for adsorbing and desorbing a refrigerant under predetermined thermodynamic conditions; a cooling unit; and a circulation system adapted for circulating refrigerant from the first highly adsorptive structure and the second highly adsorptive structure to the cooling unit to provide cooling from the thermal energy source and to return the refrigerant to at least one of the first highly adsorptive structure and the second highly adsorptive structure.

Baumann, Theodore F.↗

Exploring the Potential of ASHRAE Guideline 36 in District Cooling Systems: Preprint

ASHRAE Guideline 36-2021 (G36) provides high-performance control sequences for all-air and hydronic HVAC systems, and it has proven effective at reducing energy use for single building all-air equipment. The most recent version of G36 included control sequences for water-cooled chiller plants, which can be used in district cooling systems (DCSs). Despite not being a traditional application of G36 controls, DCSs could benefit from energy savings that G36 control sequences have demonstrated in single building systems. We therefore investigate the possibility to extend G36 chiller plant control from a single building to district cooling using a real-world district cooling system in Boulder, Colorado as a case study. Four timeframes representing low to peak loads are simulated and analyzed to compare energy use of the district cooling system for three control sequences. Results show that although G36 chiller plant sequences can be applied to DCSs, further analysis and potentially control optimization is needed to ensure energy savings compared to default controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Two-phase flow measurements and observations in a cooling panel of the reactor cavity cooling system

The analysis of the flow behavior within a cooling panel of a scaled water-cooled reactor cavity cooling system has been performed supported by high-resolution measurements of the void fraction at the risers’ outlet. The results have shown a stable, symmetric distribution of the flow through the risers during subcooled boiling conditions, characterized by small, slow bubbles with average void fraction lower than 0.3 for all risers. As the temperature increased to saturation, flow distribution appeared strongly asymmetrical and unstable, with peaks of void fraction as high as 0.9. Large, faster bubbles were observed during these peaks, immediately followed by flow of subcooled liquid water. Flow stagnation and inversion has also been observed. The high resolution void fraction results, complemented by the measurements of the coolant flow rate and temperatures, not only have further described the behavior of the system under hypothetical accident conditions, but represent a unique set of data to support the validation of system-level codes, and more advanced computational tools.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Providing Thermal Stability for an Exascale Supercomputer: A Case Study of Frontier's Cooling System

High performance computing (HPC) systems frequently produce large dynamic power swings, even under typical operating conditions, that can present a significant challenge for their direct-liquid cooling systems. Further, the primary cooling loops that must remove this waste heat have response times measured in minutes while the underlying HPC component thermal stress is measured in seconds. The per-socket power demand for both compute processing units (CPUs) and graphic processing units ( GPUs) continues to increase with each successive generation while case temperatures are declining. New HPC systems are expected to exacerbate the challenge of these dynamic power swings and the impact on effective and timely cooling systems. This paper describes the cooling and controls system for Oak Ridge National Laboratory’s Frontier Supercomputer, the first sustained exascale system, as a case study for this situation. The cooling and control system for Frontier demonstrates specific success, but with a number of trade-offs and decisions that suggest further design and operating optimizations for the community at large to consider.

42 ENGINEERING↗

Coupling Subsurface and Above-Surface Models for Optimizing the Design of Borefields and District Heating and Cooling Systems

Accurate dynamic energy simulation is important for the design and sizing of district heating and cooling systems with geothermal heat exchange for seasonal energy storage. Current modeling approaches in building and district energy simulation tools typically consider heat conduction through the ground between boreholes without flowing groundwater. While detailed simulation tools for subsurface heat and mass transfer exist, these fall short in simulating above-surface energy systems. To support the design and operation of such systems, the study developed a coupled model including a software package for building and district energy simulation, and software for detailed heat and mass transfer in the subsurface. For the first, it uses the open-source Modelica Buildings Library, which includes dynamic simulation models for building and district energy and control systems. For the heat and mass transfer in the soil, it uses the TOUGH simulator. The TOUGH family of codes can model heat and multi-phase, multi-component mass transport for a variety of fluid systems, as well as chemical reactions, in fractured porous media. The study validated the coupled modeling approach by comparing the simulation results with one from the g-function based ground response model. It then looked into effects when the water table and the regional groundwater flow are considered in the ground, from the perspective of heat exchange between borehole and ground, and the electrical consumption of the district heating and cooling systems. To access the simulation models, please find the links in the submission: -- For coupled approach validation: see model Buildings.Fluid.Geothermal.Borefields.Examples.BorefieldsWithTough and Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from the "Modelica Building Library" resource, branch issue1495_tough_interface, commit a2667c0. -- For the study of the effect of water table: see model Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from he "Modelica Building Library" resource, branch issue1495_tough_interface_moreIO, commit 760de49. -- For the study of the effect of regional groundwater flow: see Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from he "Modelica Building Library" resource, branch issue1495_tough_interface_moreIO_3D, commit c2a2d2a. The coupling interface script "GrounResponse.py" can be found from the above links in the folder Buildings/Resources/Python-Sources. Also, the needed files for TOUGH simulation are in the folder Buildings/Resources/Python-Sources/ToughFiles that can be accessed through the above links. A brief description of these files is given below; detailed specifications for the first three files may be found in the TOUGH3 Users Guide (Jung et al., 2018) https://tough.lbl.gov/documentation/tough-manuals/. (1) INCON - initial conditions for each grid block (2) INFILE - main input file with material properties and control parameters (3) MESH - description of the computational grid (4) readsave - Modelica/TOUGH interface program: read the final output of TOUGH simulation after TOUGH time step and prepare for transfer to Modelica for next Modelica time step (5) readsave.inp - input parameters for program readsave (6) writeincon - Modelica/TOUGH interface program: write the output of Modelica after Modelica time step and prepare for transfer to TOUGH as initial conditions for the next TOUGH step (7) writeincon.inp - input parameters for program writeincon

15 GEOTHERMAL ENERGY↗

AMS Thermal Cooling System (Final Report)

The Alpha Magnetic Spectrometer (AMS) is a U.S. Department of Energy-sponsored particle physics experiment on the International Space Station (ISS). AMS is exploring some of the most fundamental questions in physics such as understanding dark matter, antimatter, the origin of cosmic rays and their characteristics as well as searching for new physics phenomena in the universe. It has recorded more than 200 billion cosmic rays since its launch in May 2011. Over time, anomalies associated with the dedicated cooling system of the AMS Silicon Tracker system were observed, leading to the discovery of progressive deterioration in the functioning of the cooling system's four redundant pumps. The Tracker is crucial to the scientific mission of AMS, as it is the only subdetector that can distinguish matter from antimatter. This report details the successful program of work for the installation of the Upgraded Tracker Thermal Pump System (UTTPS) on AMS. This program included: identifying the root cause of deterioration in the original pumps; design, production, testing, and integration of the new UTTPS cooling system; launch of the UTTPS to ISS; installation of the UTTPS in AMS across a series of four complex extra-vehicular activities (EVAs); and establishment of a dedicated Flight Simulator Laboratory to test the performance of the UTTPS under various thermal conditions. This program was critical to the success of the AMS experiment, and its successful completion will enable AMS to continue taking data through 2030.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stochastic scheduling for commercial building cooling systems: considering uncertainty in zone temperature prediction

Here, this paper presents the first attempt to address the uncertainty in zone temperature prediction with stochastic optimization. The uncertain zone temperature is a process uncertainty and has not been considered in the existing stochastic optimization for building control. To fill this gap, we proposed a novel formulation of stochastic optimization to handle process uncertainty in building control. Specifically, we first examined the accuracy of a typical linear model for predicting zone temperature. We then formulated the scheduling of the building cooling system as a stochastic optimization problem over a 24-hour look-ahead period to minimize the electricity cost of the studied building cooling system. After that, we applied the proposed stochastic load scheduling (SLS) to a direct expansion (DX) cooling system that serves a medium office building. Through simulation with a detailed building energy simulation software, EnergyPlus, we evaluated the operational cost and the thermal comfort compared with a deterministic load scheduling. The operation cost of scheduling was found to vary with the level of zone temperature prediction uncertainty. The proposed SLS can mitigate the impacts of uncertain zone temperature predictions on both operational cost and thermal comfort. The evaluation results indicate that the proposed SLS works better when the uncertainty level is more significant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and evaluation of an open-source, conformable skin-cooling system for body magnetic resonance guided focused ultrasound treatments

Magnetic resonance guided focused ultrasound (MRgFUS) treatment of tumors uses inter-sonication delays to allow heat to dissipate from the skin and other near-field tissues. Despite inter-sonication delays, treatment of tumors close to the skin risks skin burns. This work has designed and evaluated an open-source, conformable, skin-cooling system for body MRgFUS treatments to reduce skin burns and enable ablation closer to the skin. A MR-compatible skin cooling system is described that features a conformable skin-cooling pad assembly with feedback control allowing continuous flow and pressure maintenance during the procedure. System performance was evaluated with hydrophone, phantom and in vivo porcine studies. Sonications were performed 10 and 5 mm from the skin surface under both control and forced convective skin-cooling conditions. 3D MR temperature imaging was acquired in real time and the accumulated thermal dose volume was measured. Gross analysis of the skin post-sonication was further performed. Device conformability was demonstrated at several body locations. Hydrophone studies demonstrated no beam aberration, but a 5–12% reduction of the peak pressure due to the presence of the skin-cooling pad assembly in the acoustic near field. Phantom evaluation demonstrated there is no MR temperature imaging precision reduction or any other artifacts present due to the coolant flow during MRgFUS sonication. The porcine studies demonstrated skin burns were reduced in size or eliminated when compared to the control condition. An open-source design of an MRgFUS active skin cooling system demonstrates device conformability with a reduction of skin burns while ablating superficial tissues.

60 APPLIED LIFE SCIENCES↗

Analysis of basic airflow configurations for separate sensible and latent cooling systems with indoor air recirculation

Separate sensible and latent cooling (SSLC) is a technology with efficiency and comfort advantages over conventional cooling systems used for space conditioning of buildings. Using multiple cooling processes at different temperatures allows SSLC to save energy by raising the evaporation temperature of the sensible cooling process. In this paper, all possible airflow configurations of SSLC systems are enumerated under the following constraints: exactly two heat exchangers are used, and air is recirculated to the conditioned space (no exhaust or outdoor air treatment). Seven designs are identified, with varying free operating variables, and each is modeled. Analysis reveals that several configurations are equivalent, and there is only one unique basic airflow SSLC configuration: the one with the sensible and latent heat exchangers placed in series. The efficiency of the SSLC system is compared against that of the conventional system. Under standard conditions, an SSLC system can improve the coefficient of performance by 14.8%. In addition to the numerical simulation, the optimal operating condition of the basic air configuration of the SSLC system is derived analytically. The basic SSLC system is shown to offer the highest performance improvement when the outdoor temperature is relatively cool and the space sensible heat ratio is high.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Fidelity Simulations of Air-Cooled Reactor Cavity Cooling System

High Temperature Gas Reactor (HTGR) designs incorporate passive safety systems (e.g., the Reactor Cavity Cooling System [RCCS]) that utilize natural principles to manage heat dissipation from the reactor pressure vessel (RPV) during accidents or routine shutdowns. The industry community is experiencing a pressing need for advanced simulation tools that can accurately assess the performance of these types of systems. In the literature, a knowledge gap exists concerning high-fidelity data for the RCCS, and this gap is one of the areas of focus of the present study. This research focuses on a specific RCCS designed for General Atomics' Modular High-Temperature Gas Reactor (GA-MHTGR). Experimental studies on a scaled version (can be seen in Figure 1) of the air-cooled RCCS used in GA-MHTGR were conducted by the University of Wisconsin-Madison (UW-Madison). This work contributes to a broader initiative aimed at establishing a numerical benchmark based on the UW-Madison experiments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Independent temperature and humidity control of a precooled desiccant air cooling system with proportional and fuzzy logic + proportional based controllers

Providing room comfort quickly by using less energy in cooling systems is important both in terms of efficiency and environment. In this study, independent temperature/humidity control strategies are designed for precooled desiccant based evaporative cooling system to provide room comfort quickly with less energy. Therefore, the speed controls of the system's actuators become important depending on the room, cooler and atmosphere conditions. The mathematical models are obtained to determine the relation between voltages of actuators and the variations in the room's temperature and humidity. After that, new control strategies are developed based on Proportional and Fuzzy+Proportional techniques and the control performance is increased by adding extra modes to the operation of the actuators. The effects of the control techniques on the cooling performance and energy consumption were investigated for different cases. It has been observed that the room temperature and relative humidity reach the set values in a short time for both techniques and are successfully kept at these values under the disturbances. By using Fuzzy+Proportional controller, the robustness of the cooler increases due to more precisely adjustment of controller's parameter depending the system conditions. Finally, both control strategies provide more than 20% energy savings compared to the traditional ON/OFF control.

42 ENGINEERING↗

MFVI Energy Efficiency Audit Training Module 3.1: Cooling Systems [Slides]

This slide deck is designed to help trained energy efficiency professionals conduct an energy efficiency audit for commercial and industrial buildings, particularly for micro-, small-, and medium-sized businesses in Mexico. This training module is focused on cooling systems. As such, it will assist its user in determining the optimal cooling system for a given space and then identifying the most efficient means of delivering that system.

21CPP↗