Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control strategy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through (FRT) capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop, and the instability if the VI is not adaptive. Simulation results of various unbalanced faults with high and low fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high and low fault impedances.

adaptive virtual impedance control↗

Robust cooperative control strategy for a platoon of connected and autonomous vehicles against sensor errors and control errors simultaneously in a real-world driving environment

In a real-world driving environment, a platoon of connected and autonomous vehicles (CAVs) is subject to many internal and external disturbances, resulting in uncertain vehicle dynamics. In general, the disturbances can be categorized into two types: disturbances due to vehicle sensor errors (e.g., GPS error) and disturbances due to vehicle control errors (e.g., actuator delay). In the literature, many control strategies have been proposed to improve the robustness of the CAV platoon against uncertain vehicle dynamics induced by these disturbances. However, most of these strategies only consider one type of disturbance and cannot tackle both types of disturbances simultaneously. Furthermore, they are designed to maximize the benefits of each vehicle in the platoon independently, which can deteriorate the performance of the platoon. Here, to address these problems, this study proposes a robust cooperative control (RCC) strategy to maneuver the vehicles in the platoon cooperatively to counteract the impacts of both types of disturbances. The RCC strategy is developed based on a minimax problem, where the maximization subproblem seeks to find the worst inputs for the uncertainty terms in the vehicle dynamics equation to minimize the platoon performance, while the minimization subproblem seeks to find the optimal control decisions for all subsequent vehicles to maximize the platoon performance in the worst case. To solve the minimax problem, this study proposes a globally convergent solution algorithm. It can solve the minimax problem very efficiently to enable real time deployment of the RCC strategy. Numerical application indicates that compared to the existing methods, the RCC strategy can dramatically improve the robustness of the CAV platoon against the uncertain vehicle dynamics induced by both vehicle state detection errors and vehicle control errors. Therefore, it can maneuver the CAV platoon safely and efficiently in a real-world driving environment.

33 ADVANCED PROPULSION SYSTEMS↗

Leveraging Real-World Driving Data for Design and Impact Evaluation of Energy Efficient Control Strategies

Modeling and simulation are crucial in the development of advanced energy efficient control strategies. Utilizing real-world driving data as the underlying basis for control design and simulation lends veracity to projected real-world energy savings. Standardized drive cycles are limited in their utility for evaluating advanced driving strategies that utilize connectivity and on-vehicle sensing, primarily because they are typically intended for evaluating emissions and fuel economy under controlled conditions. Real-world driving data, because of its scale, is a useful representation of various road types, driving styles, and driving environments. The scale of real-world data also presents challenges in effectively using it in simulations. A fast and efficient simulation methodology is necessary to handle the large number of simulations performed for design analysis and impact evaluation of control strategies. In this study, two methods are presented of leveraging real-world data in both design optimization of energy efficient control strategies and in evaluating the real-world impact of those control strategies upon large-scale deployment. Through these methodologies, strategies with highest impact on energy savings were selected to be implemented as control algorithms. The developed algorithms were incorporated into a vehicle dynamics and powertrain control architecture implemented on a Cadillac CT6 demonstration vehicle. The control algorithms were then exercised on real-world driving scenarios to determine their impact on collective energy savings. The methodology utilizes the large-scale driving data sets maintained by the National Renewable Energy Laboratory to extract real-world driving scenarios and efficient simulation software tools. The insights obtained through this research help in guiding technology selection for energy efficient driving controls.

ARPA-E↗

Intelligent multi-zone residential HVAC control strategy based on deep reinforcement learning

Residential heating, ventilation, and air conditioning (HVAC) has been considered as an important demand response resource. However, the optimization of residential HVAC control is no trivial task due to the complexity of the thermal dynamic models of buildings and uncertainty associated with both occupant-driven heat loads and weather forecasts. In this paper, we apply a novel model-free deep reinforcement learning (RL) method, known as the deep deterministic policy gradient (DDPG), to generate an optimal control strategy for a multi-zone residential HVAC system with the goal of minimizing energy consumption cost while maintaining the users’ comfort. Here, the applied deep RL-based method learns through continuous interaction with a simulated building environment and without referring to any prior model knowledge. Simulation results show that compared with the state-of-art deep Q network (DQN), the DDPG-based HVAC control strategy can reduce the energy consumption cost by 15% and reduce the comfort violation by 79%; and when compared with a rule-based HVAC control strategy, the comfort violation can be reduced by 98%. In addition, experiments with different building models and retail price models demonstrate that the well-trained DDPG-based HVAC control strategy has high generalization and adaptability to unseen environments, which indicates its practicability for real-world implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of wind-farm control strategies under realistic offshore wind conditions: wake quantities of interest

Wind-farm control strategies aim to increase the efficiency, and therefore lower the levelized cost of energy, of wind farms. This is done by using turbine settings such as the yaw angle, blade pitch angles, or generator torque to manipulate the wake that negatively affects downstream turbines in the farm. Two inherently different wind-farm control methods have been identified in the literature: wake steering (WS) and active wake mixing (AWM). As one of two companion papers focused on understanding practical aspects of these two wind-farm control strategies using large-eddy simulation (LES), we below analyze the wake quantities of interest for a single wind turbine performing WS and AWM, while the companion article (Frederik et al., 2025) focuses on turbine quantities of interest including power and structural loads for the same computational setup and also includes two-turbine arrays with full and partial wake overlap. The simulations, which are based in the LES solver AMR-Wind, are tailored to have inflow conditions representative of measurements from a site off the East Coast of the US, including with strong veer and low turbulence. The turbine, which is modeled in OpenFAST and coupled to the LES, is the IEA 15 MW, an open-source offshore design. After presenting an overview of the wake recovery for the different wake-control cases, the analysis probes the fluid-dynamic causes for the different performance of the arrays reported in the companion article by examining control volumes around the wakes and the budget of the mean-flow kinetic energy (MKE) within these volumes. In the high veer environment considered, the MKE recovery is dominated by mean convection, and this is shown to especially benefit the WS strategy when a neighboring turbine is directly downstream: there is ≈65 % more available power for a downstream turbine than in the baseline case, and this power is gained primarily through mean convection on the left-tip and top-tip faces of the control volume. However, the case with imperfect knowledge of the exact wind direction favors the pulse-type AWM strategy, largely because of ≈9 % increased turbulent entrainment from aloft versus the baseline that could be related to an apparent resistance to skewing in the pulsed wake. The general reduced effectiveness of helix-type and other individual-pitch-based AWM strategies for inflow with high veer and low turbulence as reported in the companion paper is due, in part, to low magnitudes of phase-averaged turbulent entrainment. Two main findings of this study are thus that veer has a significant impact on the effectiveness of different wake-control strategies and that pulse-type AWM may be a useful strategy when the objective is power maximization in realistic, offshore flow environments with imperfect knowledge of the exact wake overlap position on the downstream turbine.

17 WIND ENERGY↗

A Comprehensive Analysis of Energy and Daylighting Impact of Window Shading Systems and Control Strategies on Commercial Buildings in the United States

Commercial buildings consume approximately 1.9 EJ of energy in the United States, 50% of which is for heating, cooling, and lighting applications. It is estimated that windows contribute up to 34% of the energy used for heating and cooling. However, window retrofits are not often undertaken to increase energy efficiency because of the high cost and disruptive nature of window installation. Highly efficient window technologies would also need shading devices for glare prevention and visual comfort. An automated window shading system with an appropriate control strategy is a technology that can reduce energy demand, maintain occupant comfort, and enhance the aesthetics and privacy of the built environment. However, the benefits of the automated shades currently used by the shading industry are not well studied. The topic merits an analysis that will help building owners, designers and engineers, and utilities make informed decisions using knowledge of the impact of this technology on energy consumption, peak demand, daylighting, and occupant comfort. This study uses integrated daylight and whole-building energy simulation to evaluate the performance of various control strategies that the shading industry uses in commercial office buildings. The analysis was performed for three different vintages of medium office buildings at six different locations in United States. The results obtained show the control strategies enabled cooling energy savings of up to 40% using exterior shading, and lighting energy savings of up to 25%. The control strategies described can help building engineers and researchers explore different control methods used to control shading in actual buildings but rarely discussed in the literature. This information will give researchers the opportunity to investigate potential improvements in current technologies and their performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of wind farm control strategies under realistic offshore wind conditions: turbine quantities of interest

Abstract. Wind farm flow control is a strategy to increase the efficiency and therefore lower the levelized cost of energy of a wind farm. This is done using turbine settings such as the yaw angle, blade pitch angles, or generator torque to manipulate the flow behind the turbine, affecting downstream turbines in the farm. Two inherently different wind farm flow control methods have been identified in the literature: wake steering and wake mixing. This paper focuses on comparing the turbine quantities of interest between these methods for a simple two-turbine wind farm setup, while a companion article (Brown et al., 2025) focuses on the wake quantities of interest for a single wind turbine setup. Both papers use the same set of wind farm simulations based on high-fidelity large-eddy simulations (LESs) coupled with OpenFAST turbine models. First, precursor simulations are executed in order to match wind conditions measured with lidars in an offshore wind farm off the east coast of the USA. These measurements show general wind conditions that exhibit substantially higher vertical wind shear and veer than any of the LES studies performed with wind farm flow control strategies currently available in the literature. The precursors are used to evaluate the effectiveness of the control methods. In the LES, the wind veer leads to highly skewed wakes, which have considerable influence on the power uplift of wind farm flow control strategies. In addition to a baseline controller, four different control strategies, each of which uses either pitch or yaw control, are performed on the upstream turbine of a simple two-turbine wind farm. Assuming that the wind direction is known and constant over time, the simulations show that wake steering is generally the superior wind farm flow control strategy, considering both wind farm power production and turbine damage equivalent loads when substantial wind veer is present. This result is consistent over different wind speeds and wind directions. On the other hand, for similar wind conditions with lower veer, wake mixing was found to yield the highest power production, although at the expense of generally higher loads. This leads us to conclude that the effect of wind veer, which has so far not usually been considered, can not be neglected when determining the optimal wind farm flow control strategy.

17 WIND ENERGY↗

A Decoupled Droop Control Strategy for Cascaded Multicell Inverter with Low-Frequency Modulation

Cascaded multicell inverter (CMI), featured by its merits of modularity and fault-tolerance, is suitable for medium-voltage applications without using bulky step-up transformers. However, little research has reported grid-forming control of the CMI for the application in the power grid with high penetrations of inverter-interfaced generation. To bridge this research gap, this paper proposes a novel droop control strategy for the CMI with a low-frequency modulation to offer inertia and reactive power support to the power grid. A decoupled Q/V droop control strategy is proposed to eliminate the coupling effect from the P/ω control loop caused by the phase-angle difference between the voltages of the CMI and the grid. The output of the Q/V control loop is set as the reference voltage for each cell of the CMI, which makes the CMI naturally a voltage source to provide a grid-forming capability. Finally, the proposed control strategy shows great active and reactive power regulation and sharing capability, which is validated by simulation on two 100 kW, 2.4 kV CMIs connected in parallel to a power grid.

14 SOLAR ENERGY↗

Feedback Control Strategy for Transient Stability Application

Power systems are subjected to a wide range of disturbances during daily operations. Severe disturbances, such as a loss of a large generator, a three-phase bolted fault on a generator bus, or a loss of a transmission line, can lead to the loss of synchronism of a generator or group of generators. The ability of a power system to maintain synchronism during the few seconds after being subjected to a severe disturbance is known as transient stability. Most of the modern methods of controlling transient stability involve special protection schemes or remedial action schemes. These special protection schemes sense predetermined system conditions and take corrective actions, such as generator tripping or generation re-dispatch, in real time to maintain transient stability. Another method is the use of a real-time feedback control system to modulate the output of an actuator in response to a signal. This paper provides a fundamental evaluation of the use of feedback control strategies to improve transient stability in a power system. An optimal feedback control strategy that modulates the real power injected and absorbed by distributed energy-storage devices is proposed. Its performance is evaluated on a four-machine power system and on a 34-machine reduced-order model of the Western North American Power System. The result shows that the feedback control strategy can increase the critical fault clearing time by 60%, thereby improving the transient stability of the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development and assessment of a model predictive controller enabling anticipatory control strategies for a heat-pipe system

To support the reliable and resilient operation of modular reactors and microreactors, anticipatory control strategies have been proposed for achieving faster-than-real-time predictions and decision-making capabilities in anticipation of potential anomalies, including setpoint changes and cyber incidents. Here this work presents how anticipatory control strategies can be implemented via model predictive control (MPC) of a single heat pipe’s temperature. Considering the uncertainty in developing and applying MPC, this work evaluates MPC performance given three different model forms: a linear response surface model, an artificial neural network (ANN), and an autoregressive model with exogenous input (ARX). This work also evaluates the impacts of different input biases and variance on MPC performance in order to account for potential sensor reading variations due to cyber incidents. We observe that nonparametric models such as the ANN and ARX result in more fluctuated control actions compared to the MPC applied to the linear response surface model. However, when the cyber incidents are of a large magnitude, the linear response surface model produces smaller feasible regions than the nonparametric models under identical constraints.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

HIL Testbed and Motion Control Strategy for the Hybrid Hydraulic-Electric Architecture (HHEA)

The Hybrid Hydraulic-Electric Architecture (HHEA) was proposed in recent years to increase system efficiency of high power mobile machines and to reap the benefits of electrification without the need for large electric machines. It uses a set of common pressure rails to provide the majority of power hydraulically and small electric motors to modulate that power for precise control. This paper presents the development of a Hardware-in-the-loop (HIL) test-bed for testing motion control strategies for the HHEA. Precise motion control is important for off-road vehicles whose utility requires the machine being dexterous and performing tasks exactly as commanded. Motion control for the HHEA is challenging due to its intrinsic use of discrete pressure rail switches to minimize system efficiency or to keep the system within the torque capabilities of the electric motor. The motion control strategy utilizes two different controllers: a nominal passivity based back-stepping controller used in between pressure rail switches and a transition controller used to handle the event of a pressure rail switch. In this paper, the performance of the nominal control under various nominal and rail switching scenarios is experimentally evaluated on the HIL testbed.

33 ADVANCED PROPULSION SYSTEMS↗

An open-source framework for simulation-based testing of buildings control strategies

Here this paper presents a simulation framework for evaluating building control strategies (BCSs), developed with VOLTTRON, an opensource platform that integrates data, devices, and systems for sensing and control applications, and is based on co-simulation interfaces. It realizes an integrated environment for both testing and deploying BCSs, thereby eliminating the need for having a dedicated implementation of BCS for testing. For the first time, this framework provides critical functionalities, including scalable communication management and time-drive simulation advance, i.e., advancing the simulation based on clock time. We applied this framework to evaluating two BCSs from ASHRAE Guideline 36-2008 and ASHRAE Standard 90.1-2019. The evaluation results show that those BCSs primarily benefit the heating operation by reducing gas usage but yield insignificant savings in electricity consumption. The results also emphasize the importance of tuning the parameters of the BCSs to achieve better performances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A practical control strategy for demand flexibility with ensured occupant comfort in grid-interactive efficient buildings

This study proposes a practical and simplified demand response (DR) control strategy from the perspective of grid-interactive efficient buildings (GEBs), aiming to secure demand flexibility while ensuring occupant thermal comfort. Focusing on summer on-peak periods, a linear demand response (LDR) strategy that integrates cooling setpoint adjustment and lighting dimming was designed, and its performance was quantitatively evaluated. A case study was conducted using EnergyPlus-based simulations for a U.S. DOE small office prototype building under summer on-peak weather conditions. Compared with a conventional rapid demand response (RDR) strategy, the proposed LDR approach gradually reduced electrical loads while maintaining occupant thermal comfort indices, including predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), within acceptable comfort ranges. Quantitative analysis of demand flexibility using the grid-interactive impact index (GII) and the flexibility strength index (FSI) showed that the LDR strategy provided approximately 12.5% demand flexibility during DR periods and achieved an electricity cost reduction of about 8.8%. In addition, the results of the part-load ratio (PLR)-based cooling system performance analysis showed that, in the on-peak period, the LDR strategy exhibited improved cooling performance compared with the baseline. Overall, this study shows the potential of a practical DR control strategy that can simultaneously achieve occupant comfort and demand flexibility without relying on complex advanced control technologies.

Jung, Dong Eun↗

Field Testing of a Hierarchical Model-Free Transactive Control Strategy in a Residential House

Demand response plays an important role in addressing the uncertain, intermittent, and variable nature of renewable energy sources. However, to be effective, it requires a significant amount of demand load flexibility, in which buildings are important flexible assets for electricity systems. In this regard, many transactive control tools have been developed to harness this demand flexibility. Yet, such tools are mostly simulation-based or deal with a single load, which may not be sufficient to demonstrate their effectiveness. Towards this end, this paper presents a field implementation and testing of a hierarchical model-free transactive control strategy using residential building thermostatically controlled loads. The transactive control implementation incorporates elements of virtual battery, game theory, and model-free control mechanisms. Experimental field-testing results are provided to demonstrate the effectiveness of the proposed transactive control strategy.

Olama, Mohammed M.↗

Reinforcement Learning-Based Secondary Control Strategy for Voltage and Frequency Regulation in Islanded Inverter-Based Microgrids

This paper presents a reinforcement learning (RL) approach for secondary voltage and frequency control in islanded inverter-based microgrids. The proposed control strategy aims to restore voltage and frequency deviations caused by the primary droop control while ensuring proper power sharing between distributed generators. The RL agent is designed to provide correction signals to the primary control, considering communication delays and system constraints. The effectiveness of the proposed control strategy is validated through simulation results in MATLAB/Simulink environment, demonstrating superior performance in maintaining voltage and frequency within the nominal values.

Rodriguez Martinez, Omar Felipe [University of Pue↗

Verification and Validation of Model-Scale Turbine Performance and Control Strategies for the IEA Wind 15 MW Reference Wind Turbine

To enable the fast growth of the floating offshore wind industry, simulation models must be validated with experimental data. Floating wind model-scale experiments in wind–wave facilities have been performed over the last two decades with varying levels of fidelity and limitations. However, the turbine controls in these experiments have considered only limited control strategies and implementations. To allow for control co-design, this research focuses on implementing and experimentally validating more advanced turbine control actions and strategies in a wind–wave basin for a 1:70-scale model of the International Energy Agency’s wind 15 MW reference wind turbine. The control strategies analyzed include torque control, collective pitch control, and transition region control (setpoint smoothing). Our experimental and numerical results include the effects of varying rotor speeds, blade pitches, and wind environments on the turbine thrust and torque. Numerical models from three different software tools are presented and compared to the experimental results. Their ability to effectively represent the aero-dynamic response of the wind turbine to the control actions is successfully validated. Finally, turbine controller tuning parameters based on the derivatives of thrust and torque are derived to allow for improved offshore wind turbine dynamics and to validate the ability of modeling tools to model the dynamics of floating offshore wind turbines with control co-design.

17 WIND ENERGY↗

A Priority-Based Control Strategy and Performance Bound for Aggregated HVAC-Based Load Shaping

Air conditioning systems have been recognized as a potential, cost-effective resource for shaping electrical load in a power system. This work presents a new priority-based control strategy that explicitly addresses three requirements for using a collection of air conditioning units in this capacity. These are 1) tracking a regulation signal, 2) maintaining the building temperature near its set point, and 3) satisfying a cycling constraint of the air conditioners. After introducing the control strategy, we derive a bound for the regulation signal within which tracking is guaranteed while also satisfying the temperature requirement. These results are illustrated with simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Performance of a Nonlinear Control Strategy to Regulate Temperature of a High-Temperature Solar Reactor

Abstract Despite the significant potential of solar thermochemical process technology for storing solar energy as solid-state solar fuel, several challenges have made its industrial application difficult. It is important to note that solar energy has a transient nature that causes instability and reduces process efficiency. Therefore, it is crucial to implement a robust control system to regulate the process temperature and tackle the shortage of incoming solar energy during cloudy weather. In our previous works, different model-based control strategies were developed namely a proportional integral derivative controller (PID) with gain scheduling and adaptive model predictive control (MPC). These methods were tested numerically to regulate the temperature inside a high-temperature tubular solar reactor. In this work, the proposed control strategies were experimentally tested under various operation conditions. The controllers were challenged to track different setpoints (500 °C, 1000 °C, and 1450 °C) with different amounts of gas/particle flowrates. Additionally, the flow controller was tested to regulate the reactor temperature under a cloudy weather scenario. The ultimate goal was to produce 5 kg of reduced solar fuel magnesium manganese oxide (MgMn2O4) successfully, and the controllers were able to track the required process temperature and reject disturbances despite the system's strong nonlinearity. The experimental results showed a maximum error in the temperature setpoint of less than 0.5% (6 °C), and the MPC controller demonstrated superior performance in reducing the control effort and rejecting disturbances.

Energy & Fuels↗