Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “condition assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An Updated Methodology for Enhancing Risk Monitors with Integrated Equipment Condition Assessment

Small modular reactors (SMRs) generally include reactors with electric output of ~350 MWe or less (this cutoff varies somewhat but is substantially less than full-size plant output of 700 MWe or more). Advanced SMRs (AdvSMRs) refer to a specific class of SMRs and are based on modularization of advanced reactor concepts. Enhancing affordability of AdvSMRs will be critical to ensuring wider deployment, as AdvSMRs suffer from loss of economies of scale inherent in small reactors when compared to large (~greater than 600 MWe output) reactors and the controllable day-to-day costs of AdvSMRs will be dominated by operation and maintenance (O&M) costs. Technologies that help characterize real-time risk are important for controlling O&M costs. Risk monitors are used in current nuclear power plants to provide a point-in-time estimate of the system risk given the current plant configuration (e.g., equipment availability, operational regime, and environmental conditions). However, current risk monitors are unable to support the capability requirements listed above as they do not take into account plant-specific normal, abnormal, and deteriorating states of active components and systems. This report documents technology developments towards enhancing risk monitors that, if integrated with supervisory plant control systems, can provide the capability requirements listed and meet the goals of controlling O&M costs. The report describes research results on augmenting an initial methodology for enhanced risk monitors that integrate real-time information about equipment condition and POF into risk monitors. Methods to propagate uncertainty through the enhanced risk monitor are evaluated. Available data to quantify the level of uncertainty and the POF of key components are examined for their relevance, and a status update of this data evaluation is described. Finally, we describe potential targets for developing new risk metrics that may be useful for studying trade-offs for economic operation while maintaining adequate safety margins.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dielectric Spectroscopy for Bulk Condition Assessment of Low Voltage Cable (Interim Report)

This Pacific Northwest National Laboratory milestone report describes progress to date on the investigation of nondestructive test methods focusing on bulk cable insulation testing using a dielectric spectroscopy (DS) approach. This report addresses relevant literature coupled with a discussion of the theory of DS measurements and work on modeling to appreciate the influence of damage/defect profile on the bulk total cable measurement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Technical Report on Preliminary Methodology for Enhancing Risk Monitors with Integrated Equipment Condition Assessment

Small modular reactors (SMRs) generally include reactors with electric output of ~350 MWe or less (this cutoff varies somewhat but is substantially less than full-size plant output of 700 MWe or more). Advanced SMRs (AdvSMRs) refer to a specific class of SMRs and are based on modularization of advanced reactor concepts. AdvSMRs may provide a longer-term alternative to traditional light-water reactors (LWRs) and SMRs based on integral pressurized water reactor concepts currently being considered. Enhancing affordability of AdvSMRs will be critical to ensuring wider deployment. AdvSMRs suffer from loss of economies of scale inherent in small reactors when compared to large (~greater than 600 MWe output) reactors. Some of this loss can be recovered through reduced capital costs through smaller size, fewer components, modular fabrication processes, and the opportunity for modular construction. However, the controllable day-to-day costs of AdvSMRs will be dominated by operation and maintenance (O&M) costs. Technologies that help characterize real-time risk are important for controlling O&M costs. Risk monitors are used in current nuclear power plants to provide a point-in-time estimate of the system risk given the current plant configuration (e.g., equipment availability, operational regime, and environmental conditions). However, current risk monitors are unable to support the capability requirements listed above as they do not take into account plant-specific normal, abnormal, and deteriorating states of active components and systems. This report documents technology developments that are a step towards enhancing risk monitors that, if integrated with supervisory plant control systems, can provide the capability requirements listed and meet the goals of controlling O&M costs. The report describes research results from an initial methodology for enhanced risk monitors by integrating real-time information about equipment condition and POF into risk monitors.

advanced small modular reactor↗

Incorporating Equipment Condition Assessment in Risk Monitors for Advanced Small Modular Reactors

Advanced small modular reactors (aSMRs) can complement the current fleet of large light-water reactors in the USA for baseload and peak demand power production and process heat applications (e.g., water desalination, shale oil extraction, hydrogen production). The day-to-day costs of aSMRs are expected to be dominated by operations and maintenance (O&M); however, the effect of diverse operating missions and unit modularity on O&M is not fully understood. These costs could potentially be reduced by optimized scheduling, with risk-informed scheduling of maintenance, repair, and replacement of equipment. Currently, most nuclear power plants have a “living” probabilistic risk assessment (PRA), which reflects the as-operated, as-modified plant and combine event probabilities with population-based probability of failure (POF) for key components. “Risk monitors” extend the PRA by incorporating the actual and dynamic plant configuration (equipment availability, operating regime, environmental conditions, etc.) into risk assessment. In fact, PRAs are more integrated into plant management in today’s nuclear power plants than at any other time in the history of nuclear power. However, population-based POF curves are still used to populate fault trees; this approach neglects the time-varying condition of equipment that is relied on during standard and non-standard configurations. Equipment condition monitoring techniques can be used to estimate the component POF. Incorporating this unit-specific estimate of POF in the risk monitor can provide a more accurate estimate of risk in different operating and maintenance configurations. This enhanced risk assessment will be especially important for aSMRs that have advanced component designs, which don’t have an available operating history to draw from, and often use passive design features, which present challenges to PRA. This paper presents the requirements and technical gaps for developing a framework to integrate unit-specific estimates of POF into risk monitors, resulting in enhanced risk monitors that support optimized operation and maintenance of aSMRs.

Advanced Small Modular Reactors↗

Condition assessment of cable insulation materials in advanced reactor environments

While existing cable insulation materials are sufficient for use in the current reactor fleet, environmental conditions inside some advanced reactors, such as small modular reactors, will be substantially harsher. The work herein was conducted to assess the performance and overall survivability of several high-temperature, radiation resistant insulation polymers in a simulated small modular reactor environment. The materials evaluated under this research include polyether ether ketone, polyimide, and silicone rubber. These polymers were subjected to 1000 h of environmental stress exposure under two different conditions: 1) high temperature (i.e., 250 °C) in atmospheric pressure and 2) high temperature in a low-pressure vacuum (i.e., less than 2 psia). During the environmental exposure process, each insulation was periodically tested using several materials characterization techniques including Fourier transform infrared spectroscopy, oxidation induction time, and oxidation induction temperature. The objective of this testing was to assess and monitor changes that occurred in the thermal and chemical properties of the materials during the environmental exposures. The overall survivability of each insulation was assessed based on these property changes. The results of this research revealed that the polyimide and polyether ether ketone insulations had significantly better thermal and chemical stability than the silicone rubber during both the high-temperature atmospheric and vacuum exposures. Both polyimide and polyether ether ketone experienced minimal reductions in their chemical and thermal properties over the course of 1000 h in the simulated environments. Finally, based on this research, polyimide and polyether ether ketone show promise as potential base materials for small modular reactor cable insulation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Condition Assessment of Kevlar Composite Materials Using Raman Spectroscopy

This viewgraph presentation includes the following main concepts. Goal: To evaluate Raman spectroscopy as a potential NDE tool for the detection of stress rupture in Kevlar. Objective: Test a series of strand samples that have been aged under various conditions and evaluate differences and trends in the Raman response. Hypothesis: Reduction in strength associated with stress rupture may manifest from changes in the polymer at a molecular level. If so, than these changes may effect the vibrational characteristics of the material, and consequently the Raman spectra produced from the material. Problem Statement: Kevlar composite over-wrapped pressure vessels (COPVs) on the space shuttles are greater than 25 years old. Stress rupture phenomena is not well understood for COPVs. Other COPVs are planned for hydrogen-fueled vehicles using Carbon composite material. Raman spectroscopy is being explored as an non-destructive evaluation (NDE) technique to predict the onset of stress rupture in Kevlar composite materials. Test aged Kevlar strands to discover trends in the Raman response. Strength reduction in Kevlar polymer will manifest itself on the Raman spectra. Conclusions: Raman spectroscopy has shown relative changes in the intensity and FWHM of the ~1613 cm(exp -1) peak. Reduction in relative intensity for creep, fleet leader, and SIM specimens compared to the virgin strands. Increase in FWHM has been observed for the creep and fleet leader specimens compared to the virgin strands. Changes in the Raman spectra may result from redistributing loads within the material due to the disruption of hydrogen bonding between crystallites or defects in the crystallites from aging the Kevlar strands. Peak shifting has not been observed to date. Analysis is ongoing. Stress measurements may provide a tool in the short term.

Washer, Glenn↗

Historic Significance and Current Condition Assessment of Building 06-CP-170, the Yucca Flat Weather Station, Area 6, Nevada National Security Site, Nye County, Nevada

This report was produced in partial fulfillment of the mitigation of adverse effects to Building 06-CP-170, the Yucca Flat Weather Station on the Nevada National Security Site (NNSS), and is intended to comply with the 2021 Memorandum of Agreement DE-GM58-21NA25543 Between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Demolition of Fourteen Buildings and Structures in Area 6 of the Nevada National Security Site, Nye County, Nevada (hereafter referred to as the MOA). This MOA was executed to resolve adverse effects from the U.S. Department of Energy (DOE) plan to demolish 14 architectural resources at the Control Point and in the vicinity in Area 6 of the NNSS. The management and operations contractor for the NNSS identified these 14 architectural resources as environmental hazards unsafe for human occupation due to deterioration and rodent infestation. Building 06-CP-170 is scheduled for demolition as part of this undertaking. Building 06-CP-170 was originally recorded in 2018 during a Section 106 cultural resources inventory for a proposed installation of a 138-kilovolt transmission line on the NNSS. The building was determined individually eligible by the DOE, in consultation with the Nevada State Historic Preservation Office, for inclusion in the National Register of Historic Places under the Secretary of the Interior’s Significance Criterion A because of its association with nuclear testing. Pursuant to Stipulation III.D.3 of the MOA, this report provides a summary of the historic significance of Building 06-CP-170 and a description of its current condition and accessory resources. In addition, an updated Architectural Resource Assessment (ARA) form with new information and photographs is included in the appendix in fulfillment of Stipulation III.D.2.

54 ENVIRONMENTAL SCIENCES↗

Historic Significance and Current Condition Assessment of Building 06-CP-10, Device Assembly Building, Area 6, Nevada National Security Site, Nye County, Nevada

This report was produced in partial fulfillment of the mitigation of adverse effects to Building 06-CP-10, the first device assembly building on the Nevada National Security Site (NNSS), and is intended to comply with the 2021 Memorandum of Agreement DE-GM58-21NA25543 Between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Demolition of Fourteen Buildings and Structures in Area 6 of the Nevada National Security Site, Nye County (hereafter referred to as the MOA). This MOA was executed to resolve adverse effects from the U.S. Department of Energy (DOE) plan to demolish 14 architectural resources at the Control Point and in the vicinity in Area 6 of the NNSS. The management and operations contractor for the NNSS identified these 14 architectural resources as environmental hazards unsafe for human occupation due to deterioration and rodent infestation. Building 06-CP-10 and two small magazine bunkers (06-CP-10A and 06-CP-805) associated with Building 06-CP-10 are scheduled for demolition as part of this undertaking. Building 06-CP-10 was originally recorded in 2003 during a historical evaluation of four buildings in Area 6. In consultation with the Nevada State Historic Preservation Office, the building was determined individually eligible for inclusion in the NRHP under the Secretary of the Interior’s Significance Criterion A because of its association with nuclear testing and under Significance Criterion C as a distinct type of construction associated with the nuclear industry. Building 06-CP-10A, a munitions magazine, and 06- CP-805, a cap-and-fuse bunker, have been recorded as contributing accessory resources to 06-CP-10. Pursuant to Stipulation III.C.3 of the MOA, this report provides a summary of the historic significance of Building 06-CP-10 and a description of its current condition and accessory resources. In addition, an updated Architectural Resource Assessment (ARA) form with new information and photographs is included in the appendix in fulfillment of Stipulation III.C.2.

54 ENVIRONMENTAL SCIENCES↗

Uncertainty Quantification of Inducer Natural Frequency using Conditional Assessment of Modeling and Modal Testing of Simpler Systems

The low pressure fuel pump inducer of the new Space Launch System RS25 core stage engine operates in a highly complex environment that substantially affects its modal characteristics. Some of the more important effects are fluid-added mass resulting from operation within a light liquid (Hydrogen), and the magnification of this effect due to tight tip clearance. Since higher order cavitation has been identified as a significant harmonic driver, knowledge of the natural frequency of potentially excitable modes is critical for safe operation, but this frequency cannot be measured during the severe operational environment. A comprehensive testing and analysis program has therefore been performed over the last four years to identify the nominal value and uncertainty of the frequency by modeling and testing four simpler structures which share some of the characteristics of the operational inducer. This testing was used to assess and adjust modeling techniques and excellent correlation was achieved. Identification of the uncertainty in the inducer frequency itself was still problematic, however. This difficulty led to an investigation of Bayesian uncertainty quantification techniques, and to the application of the relatively simple technique of Multi-Variate Normal conditional distributions to calculate the inducer natural frequency uncertainty. Assumptions on prior distributions of uncertainty of the fluid-added mass and tip clearance effect are initially applied to models of each of the simple structures and the inducer itself, and these uncertainties are propagated to generate natural frequencies using design of experiments. Simple response surfaces are then created from this data in order to calculate a Covariance Matrix relating all of these natural frequencies. Finally, the results from modal test of the simple structures are considered to be observations and used to calculate the conditional variance of the desired inducer frequencies. As this method is less rigorous than more complicated Bayesian methods reported in the literature, a conservative factor is applied to the result, but the resulting uncertainty is still significantly less than originally estimated and will greatly assist certification of the inducer for use in the engine.

Uncertainty Quantification↗

Uncertainty Quantification of Inducer Eigenvalues using Conditional Assessment of Models and Modal Test of Simpler Systems

The low pressure fuel pump inducer of the new Space Launch System RS25 core stage engine operates in a highly complex environment that substantially affects its modal characteristics. Some of the more important effects are fluid-added mass resulting from operation within a light liquid (Hydrogen), and the magnification of this effect due to tight tip clearance. Since higher order cavitation has been identified as a significant harmonic driver, knowledge of the natural frequency of potentially excitable modes is critical for safe operation, but this frequency cannot be measured during the severe operational environment. A comprehensive testing and analysis program has therefore been performed over the last four years to identify the nominal value and uncertainty of the frequency by modeling and testing four simpler structures which share some of the characteristics of the operational inducer. This testing was used to assess and adjust modeling techniques and excellent correlation was achieved. Identification of the uncertainty in the inducer frequency itself was still problematic, however. This difficulty led to an investigation of Bayesian uncertainty quantification techniques, and to the application of the relatively simple technique of Multi-Variate Normal conditional distributions to calculate the inducer natural frequency uncertainty. Assumptions on prior distributions of uncertainty of the fluid-added mass and tip clearance effect are initially applied to models of each of the simple structures and the inducer itself, and these uncertainties are propagated to generate natural frequencies using design of experiments. Simple response surfaces are then created from this data in order to calculate a Covariance Matrix relating all of these natural frequencies. Finally, the results from modal test of the simple structures are considered to be observations and used to calculate the conditional variance of the desired inducer frequencies. As this method is less rigorous than more complicated Bayesian methods reported in the literature, a conservative factor is applied to the result, but the resulting uncertainty is still significantly less than originally estimated and will greatly assist certification of the inducer for use in the engine.

Uncertainty Quantification↗

Adaptive responses of the cardiovascular system to prolonged spaceflight conditions: assessment with Holter monitoring

This article presents selected findings obtained with Holter monitoring from two crew members of the expedition, performed during a 175-day space mission on board orbital space station "MIR." Using mathematical processing of daily cardiointervals files, 5-minute sections of records were analyzed consecutively. Then, the average daily values of indices, the average-per-every-eight-hours values (morning, evening, night) and mean values per hour were computed. The results of analysis showed that prolonged exposure of man to microgravity conditions leads to important functional alteration in human neuroautonomic regulatory mechanisms. Both crew members had significant increase of heart rate, the rise of stress index, the decrease in power of the spectrum in the range of respiratory sinus arrhythmia. These marked signs of activation of the sympathetic section of the vegetative nervous system showed individual variations. The analysis of the daily collection of cardiointervals with Holter monitoring allows us to understand and forecast the functional feasibilities of the human organism under a variety of stress conditions associated with acute and chronic microgravity exposure.

manned↗

Augmented Monitoring and Condition Assessment Program (AMCAP) Material Test Reactor (MTR) (Fuel Inspection Program Report)

The AMCAP MTR Fuel Inspection Program, a special inspection program comprised of four inspection campaigns, examined a total of ten (10) pre-selected aluminum-clad, aluminum-based fuel core spent nuclear fuel assemblies (ASNF) stored in the L Area Disassembly Basin (L Basin) at the Savannah River Site. A full description of the inspections and the results are reported. The fuel had been stored in bundled-tube storage (Vertical Tube Storage) for periods of 18 to 21 years. The prior service experience of the individual 10 assemblies varies, but all included irradiation followed by wet storage at international research reactor sites prior to shipment to the US and storage in L Basin. The 10 assemblies were expected to be among the “worst"’ in terms of prior corrosion damage of the entire inventory of the direct-bundle-stored ASNF in L Basin. The inventory of MTR ASNF in L Basin will continue to be stored in the bundled-tube configuration or in slug-storage buckets with inserts pending retrieval for ultimate disposition. The MTR fuel inspections focused on collecting information for characterization of the material condition of the ASNF considering various types of aluminum fuel corrosion degradation of its assembled materials in water storage. A custom-designed Fuel Inspection Table was used to stage the fuel for remote, enhanced visual examination (close-up video imaging & recording) with controlled lighting and positioning that enables reproducibility of imaging conditions. The inspections were conducted by fuel subject matter expert staff from Spent Fuel Project Engineering (SFPE) and the Savannah River National Laboratory (SRNL). Stills captured from the video records were used to compare the corrosion evolution from previous records, as available. This evaluation of the inspection results including the comparison to the previous inspection results demonstrate that the water quality and the storage configuration of ASNF in L Basin do not cause aggressive corrosion degradation of the fuel; mitigation of the prior corrosion degradation of the fuel also appears to have been achieved with the good water quality conditions of L Basin. Recommendations are made for future inspection of the fuel to trend corrosion degradation and demonstrate continued safe wet storage of the ASNF in L Basin. The next fuel examination is recommended to be performed in 5 years.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Byggmeister Test Home: Cold Climate Multifamily Masonry Building Condition Assessment and Retrofit Analysis

This report describes a retrofit project undertaken by Building Science Corporation and partner Byggmeister on a multifamily brick row house located in Jamaica Plain, MA. This project studied the row house to determine the right combination of energy efficiency measures that are feasible, affordable, and suitable for this type of construction and acceptable to homeowners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Byggmeister Test Home: Cold Climate Multifamily Masonry Building Condition Assessment and Retrofit Analysis

This report describes a retrofit project undertaken by Building Science Corporation and partner Byggmeister on a multifamily brick row house located in Jamaica Plain, MA. This project studied the row house to determine the right combination of energy efficiency measures that are feasible, affordable, and suitable for this type of construction and acceptable to homeowners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conditions Assessment and Preservation Work Plan for Portable Guard Shacks (TA-8-172 and TA-18-111)

The purpose of this report is to document the current state of deterioration and propose repairs for TA-8-172 and TA18-111, two portable guard shacks from the Los Alamos National Laboratory (LANL) which have been designated as historic resources. This preservation treatment plan has been prepared by the Historic Preservation Training Center (HPTC), a historic preservation program within the National Park Service, to ensure that the treatments comply with guidelines established in The Secretary of the Interior’s Standards for the Treatment of Historic Properties.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗