Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computing methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A comparison of past and present computational methods for shape analysis of double-shell x-ray radiographs

Implosion symmetry is a key requirement in achieving a robust burning plasma in inertial confinement fusion experiments. In double-shell capsule implosions, we are interested in the shape of the inner shell as it pushes on the fuel. Shape analysis is a popular technique for studying said symmetry during implosion. Combinations of filtering and contour-finding algorithms are studied for their promise in reliably recovering Legendre shape coefficients from synthetic radiographs of double-shell capsules with applied levels of noise. A radial lineout max(slope) method when used on an image pre-filtered with non-local means and a variant of the marching squares algorithm are able to recover p 0 , p 2 , and p 4 maxslope Legendre shape coefficients with mean pixel discrepancy errors of 2.81 and 3.06, respectively, for the noisy synthetic radiographs we consider. Here, this improves upon prior radial lineout methods paired with Gaussian filtering, which we show to be unreliable and whose performance is dependent on input parameters that are difficult to estimate.

47 OTHER INSTRUMENTATION↗

Computational methods based on density functional theory for reactions and processes involving electronic spin (Final Technical Report)

This award supports one post-doctoral researcher for 1.5 years. Publications that acknowledge this grant: Refs. 1–14. Refs. 3,10,12 assess current methodology for the evaluation of magnetic exchange couplings in transition metal complexes. In particular, Ref. 10 validates the use of an approximate (non-iterative) Green’s function approach for the calculation of magnetic exchange couplings and will be the foundation for Thrust 2 in this proposal. Refs. 3 and 12 focus on widely used density functional approaches based on the standard energy differences methodology for the particular case of oxo-bridged Fe(III) complexes. Refs. 2,4–7,11 apply current methodologies to problems of practical interest in molecular magnetism. Ref. 13 presents a methodology to explicitly simulate the dynamics of open quantum systems within density functional theory (DFT) calculations based on the Liouville-von Neumann equation of motion for quantum systems driven out-of-equilibrium. Ref. 8 uses non-collinear spin DFT to explain the mechanical behavior of magnetic mono-atomic Pt wires produced in break-junction experiments in the presence of a magnetic field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solvability, Operability, and Security for Cyber-Physical Systems: New Computational Methods with Revised Assumptions

In this paper discusses the use and integration of disparate but complementary tools for dealing with solvability, operability, and security challenges in Cyber-Physical Systems (CPSs): the Koopman Operator (KO) for solvability, Disjunctive Programming (DP) for operability, and Multi-Level Optimisation (MLO) for security. These methods can obviate the need for some of the traditional assumptions used in modelling CPSs. This paper demonstrates the methods' capabilities and considers ways to advance each method individually. It concludes by discussing how to integrate the different methods and identify useful synergies generated by doing so.

koopman operator, disjunctive programming, multi-l↗

Opportunities and Challenges of Computational Electromagnetics Methods for Superconducting Circuit Quantum Device Modeling: A Practical Review

High-fidelity numerical methods that model the physical layout of a device are essential for the design of many technologies. For methods that characterize electromagnetic effects, these numerical methods are referred to as computational electromagnetics (CEM) methods. Although the CEM research field is mature, emerging applications can still stress the capabilities of the techniques in use today. The design of superconducting circuit quantum devices falls in this category due to the unconventional material properties and important features of the devices covering nanometer to centimeter scales. Such multiscale devices can stress the fundamental properties of CEM tools which can lead to an increase in simulation times, a loss in accuracy, or even cause no solution to be reliably found. While these challenges are being investigated by CEM researchers, knowledge about them is limited in the broader community of users of these CEM tools. This review is meant to serve as a practical introduction to the fundamental aspects of the major CEM techniques that a researcher may need to choose between to model a device, as well as provide insight into what steps they may take to alleviate some of their challenges. Our focus is on highlighting the main concepts without rigorously deriving all the details, which can be found in many textbooks and articles. After covering the fundamentals, we discuss more advanced topics related to the challenges of modeling multiscale devices with specific examples from superconducting circuit quantum devices. We conclude with a discussion on future research directions that will be valuable for improving the ability to successfully design increasingly more sophisticated superconducting circuit quantum devices. Although our focus and examples are taken from this area, researchers from other fields will still benefit from the details discussed here.

Elkin, Samuel T. [Virginia Tech., Blacksburg]↗

System, method, and computer program product for transporting an unmanned vehicle

A method, system, and computer program product is provided for transporting an unmanned vehicle to a destination location. The method includes determining a ground vehicle from a plurality of ground vehicles based on a location of the ground vehicle, the destination location, and a location of the unmanned vehicle, controlling the unmanned vehicle to the location of the ground vehicle, controlling at least one attachment mechanism to attach the unmanned vehicle to the ground vehicle, in response to the ground vehicle traveling to a second location, controlling the at least one attachment mechanism to detach the unmanned vehicle from the ground vehicle, and controlling the unmanned vehicle to the destination location.

Samaras, Constantinos↗

Unveiling Hidden Shake-Up Features in the Uranyl M 4 -Edge Spectrum

The M 4,5 -edge high energy resolution X-ray absorption near-edge structure (HR-XANES) spectra of actinyls offer valuable insights into the electronic structure and bonding properties of heavy-element complexes. To conduct a comprehensive spectral analysis, it is essential to employ computational methods that accurately account for relativistic effects and electron correlation. In this work, we utilize variational relativistic multireference configurational interaction methods to compute and analyze the X-ray M 4 -edge absorption spectrum of uranyl. By employing these advanced computational techniques, we achieve excellent agreement between the calculated spectral features and experimental observations. Moreover, the calculations unveil significant shake-up features, which arise from the intricate interplay between strongly correlated 3d core-electron and ligand excitations. This research provides important theoretical insights into the spectral characteristics of heavy-element complexes. Furthermore, it establishes the foundation for utilizing M 4,5 -edge spectroscopy as a means to investigate the chemical activities of such complexes. By leveraging this technique, we can gain a deeper understanding of the bonding behavior and reactivity of heavy-element compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Novel Method for Preoperative Positioning of Total Ankle Replacement Using 3D Digital Model

Abstract Objective To establish a digital model of the ankle joint through 3D imaging technology and explore the preoperative placement of ankle replacement prostheses. Methods Computed tomography images of intact ankle joints from 54 cases in the outpatient and inpatient departments of our hospital were collected; according to the INBONE® total ankle system surgery process, the surgery model and surgical osteotomy were finished using MIMICS based on computer simulation method. The shortest distance was measured between the center point and the anterior, posterior, medial, and lateral, respectively, to ensure the precise position of the ankle replacement prosthesis by digital simulation surgery. The relationship between the two variables was analyzed by bivariate correlation analysis. Results The dataset of this study included 48 cases of the sub‐data set (26 males and 22 females) and included 27 cases of left ankle and 21 cases of right ankle. The average medial malleolar angle was 18.67°± 2.87°, the average amount of bone resection was 12.13 ± 1.86 cm 3 , the mid‐anterior distance was 1.72 ± 0.19 cm, the mid‐posterior distance was 2.00 ± 0.19 cm, the ratio of mid‐anterior to mid‐posterior was 0.87, the mid‐medial distance was 1.26 ± 0.17 cm, the mid‐lateral distance was 1.19 ± 0.16 cm, and the ratio of mid‐medial to mid‐lateral was 1.06. After osteotomy, the anteroposterior diameter was 3.73 ± 0.32 cm, the transverse diameter was 2.46 ± 0.27 cm, and the ratio of anteroposterior diameter to transverse diameter was 1.53. In the bottom view, the shape after osteotomy is rectangular. The mid‐anterior distance was strongly negatively correlated with age, the mid‐anterior distance and the amount of bone resection, the mid‐medial distance and the amount of bone resection, the mid‐lateral distance and the amount of bone resection, the mid‐lateral distance and the anteroposterior diameter, the anteroposterior diameter and the transverse diameter were all strongly positively correlated. Conclusion The projection point of the lower tibia centerline on the tibial horizontal osteotomy surface is located at a position slightly anterior to the midpoint of the transverse diameter after ankle arthroplasty. The rational positioning of the total ankle replacement is located at both a position slightly anterior to the midpoint of the transverse diameter and midpoint of the anteroposterior diameter, which can be used as a reference method before total ankle arthroplasty surgery.

Wu, Shi‐xun↗