At least 37 records · Page 2

Dynamic compression effects of H 2 ⁡O in a dynamic diamond anvil cell: Origin of metastable ice VII and its crystal growth kinetics

We report on the structural verification of metastable ice VII solidifying in the phase space of ice VI at 1.80 GPa at room temperature. Using time-resolved (TR) x-ray diffraction and TR ruby luminescence paired with high-speed microphotography utilizing a dynamic diamond anvil cell, an initial compression rate range from 0.12 to 95.84 GPa/s was explored. The solidification pressure of metastable ice VII has a potential sigmoidal dependence upon compression rate with a turnover compression rate of ∼80 GPa/s. The preferred crystallization of ice VII in the stability field of ice VI is due to the increased nucleation rate of ice VII over ice VI at 1.77 GPa that is driven by the surface energy difference between the liquid and solid phases along with the change in Gibbs free energy of solidification. The dynamic pressure-volume–compression behaviors of ice phases (VI and VII) show a lattice stiffening in both phases, especially during the compression loading. It is also found that the compression rate greatly affects the solid-solid phase transition between ice VI and VII but does not affect the liquid-solid transition between water and ice VI as much. Lastly, a third phase transition was found to occur after metastable ice VII transforms into high-density amorphous (HDA) ice, which could be a disordered hydrogen-bonded network configuration of ice VII forming out of HDA ice facilitated by the decoupling of the oxygen movement and reorientation of the H 2⁡ O molecule. These results demonstrate the complexity of a seemingly simple molecule H 2⁡ O, how it can readily change its static properties with the modification of (de)compression rate, and highlight the need to use multiple TR structural and spectroscopic probes at higher time resolutions to realize the most comprehensive understanding.

Chemical bonding↗

Comparison of Bystander Cardiopulmonary Resuscitation (BCPR) Performance in the Absence and Presence of Timing Devices for Coordinating Delivery of Ventilatory Breaths and Cardiac Compressions in a Model of Adult Cardiopulmonary Arrest

Astronaut crew medical officers (CMO) aboard the International Space Station (ISS) receive 40 hours of medical training during the 18 months preceding each mission. Part of this training ilncludes twoperson cardiopulmonary resuscitation (CPR) per training guidelines from the American Heart Association (AHA). Recent studies concluded that the use of metronomic tones improves the coordination of CPR by trained clinicians. Similar data for bystander or "trained lay people" (e.g. CMO) performance of CPR (BCPR) have been limited. The purpose of this study was to evailuate whether use of timing devices, such as audible metronomic tones, would improve BCPR perfomance by trained bystanders. Twenty pairs of bystanders trained in two-person BCPR performled BCPR for 4 minutes on a simulated cardiopulmonary arrest patient using three interventions: 1) BCPR with no timing devices, 2) BCPR plus metronomic tones for coordinating compression rate only, 3) BCPR with a timing device and metronome for coordinating ventilation and compression rates, respectively. Bystanders were evaluated on their ability to meet international and AHA CPR guidelines. Bystanders failed to provide the recommended number of breaths and number of compressions in the absence of a timing device and in the presence of audible metronomic tones for only coordinating compression rate. Bystanders using timing devices to coordinate both components of BCPR provided the reco number of breaths and were closer to providing the recommended number of compressions compared with the other interventions. Survey results indicated that bystanders preferred to use a metronome for delivery of compressions during BCPR. BCPR performance is improved by timing devices that coordinate both compressions and breaths.

Hurst, Victor, IV↗

Modeling of video traffic in packet networks, low rate video compression, and the development of a lossy+lossless image compression algorithm

During this reporting period we have worked on three somewhat different problems. These are modeling of video traffic in packet networks, low rate video compression, and the development of a lossy + lossless image compression algorithm, which might have some application in browsing algorithms. The lossy + lossless scheme is an extension of work previously done under this grant. It provides a simple technique for incorporating browsing capability. The low rate coding scheme is also a simple variation on the standard discrete cosine transform (DCT) coding approach. In spite of its simplicity, the approach provides surprisingly high quality reconstructions. The modeling approach is borrowed from the speech recognition literature, and seems to be promising in that it provides a simple way of obtaining an idea about the second order behavior of a particular coding scheme. Details about these are presented.

Sayood, K.↗

Characterization of Asymptotic Entrainment Rate for Compressible Jets

Experimental results for the spreading and centerline velocity decay rates are presented for round, compressible, submerged jets, with total temperature same as ambient temperature, covering a 'jet Mach number' (M(sub J)) range of 0.3 - 2.0. Data from a convergent and a convergent-divergent nozzle are considered. The spreading rate is determined from the total longitudinal mass fluxes measured by Pilot probe survey. Results for the far asymptotic regions show that both spreading and centerline velocity decay rates, when normalized by conditions at the nozzle exit, decrease with increasing M(sub J). Dimensional analysis and isentropic calculations predict this Mach number dependence well. The analysis also demonstrates that an increase in the 'potential core length' of the jet occurring with increasing M(sub J), a commonly observed trend, is largely accounted for simply by the variations in the density and static pressure at the nozzle exit. The effect of decreasing mixing efficiency with increasing compressibility is inferred to contribute only partially to the latter trend.

Zaman, K. B. M. Q.↗

Phase transition kinetics revealed by in situ x-ray diffraction in laser-heated dynamic diamond anvil cells

We report successful coupling of dynamic loading in a diamond anvil cell and stable laser heating, which enables compression rates up to 500 GPa/s along high-temperature isotherms. Dynamic loading in a diamond-anvil cell allows exploration of a wider range of pathways in the pressure-temperature space compared to conventional dynamic compression techniques. By x-ray diffraction, we are able to characterize and monitor the structural transitions with the appropriate time resolution i.e., millisecond timescales. Using this method, we investigate the γ − ε phase transition of iron under dynamic compression, reaching compression rates of hundreds of GPa/s and temperatures of 2000 K. Our results demonstrate a distinct response of the γ − ε and α − ε transitions to the high compression rates achieved, possibly due to the different transition mechanisms. These findings open up new avenues to study tailored dynamic compression pathways in the pressure-temperature space and highlight the potential of this platform to capture kinetic effects (over ms time scales) in a diamond anvil cell. Published by the American Physical Society 2024

Ricks, Matthew (ORCID:000000015315612X)↗

Variable rate neural compression for sparse detector data

Particle colliders produce data at extraordinary rates, posing major challenges for transmission and storage. High-throughput compression algorithms are therefore essential. In the sPHENIX experiment taking data at the Relativistic Heavy Ion Collider, a time projection chamber records three-dimensional (3D) particle trajectories that are highly sparse, making conventional learning-free lossy compression ineffective. Convolutional neural networks have surpassed traditional methods in compression ratio and accuracy. However, they fail to exploit sparsity for efficiency. To address these gaps, we present BCAE-VS, a bicephalous convolutional autoencoder with variable compression ratio for sparse data, which adapts compression to input complexity through key-point identification and sparse convolution. BCAE-VS achieves higher accuracy and compression ratios than prior neural approaches while being orders of magnitude smaller. Moreover, its throughput increases with sparsity—a property not observed in other methods. Although it was developed for collider experiments, BCAE-VS readily extends to other sparse data domains, such as light detection and ranging (LiDAR) sensing and 3D microscopy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A fixed/variable bit-rate data compression architecture

A VLSI architecture for an adaptive data compression encoder capable of sustaining fixed or variable bit-rate output has been developed. There are three modes of operation: lossless with variable bit-rate, lossy with fixed bit-rate and lossy with variable bit-rate. For lossless encoding, the implementation is identical to the USES chip designed for Landsat 7. Obtaining a fixed bit-rate is achieved with a lossy DPCM algorithm using adaptive, nonuniform scalar quantization. In lossy mode, variable bit-rate coding uses the lossless sections of the encoder for post-DPCM entropy coding. The encoder shows excellent compression performance in comparison to other current data compression techniques. No external tables or memory are required for operation.

Zweigle, Gregary C.↗

Metronome Use for Coordination of Breaths and Cardiac Compressions Delivered by Minimally-Trained Caregivers During Two-Person CPR

Astronaut crew medical officers (CMO) aboard the International Space Station (ISS) receive 40 hours of medical training over 18 months before each mission, including two-person cardiopulmonary resuscitation (2CPR) as recommended by the American Heart Association (AHA). Recent studies have concluded that the use of metronomic tones improves the coordination of 2CPR by trained clinicians. 2CPR performance data for minimally-trained caregivers has been limited. The goal of this study was to determine whether use of a metronome by minimally-trained caregivers (CMO analogues) would improve 2CPR performance. 20 pairs of minimally-trained caregivers certified in 2CPR via AHA guidelines performed 2CPR for 4 minutes on an instrumented manikin using 3 interventions: 1) Standard 2CPR without a metronome [NONE], 2) Standard 2CPR plus a metronome for coordinating compression rate only [MET], 3) Standard 2CPR plus a metronome for coordinating both the compression rate and ventilation rate [BOTH]. Caregivers were evaluated for their ability to meet the AHA guideline of 32 breaths-240 compressions in 4 minutes. All (100%) caregivers using the BOTH intervention provided the required number of ventilation breaths as compared with the NONE caregivers (10%) and MET caregivers (0%). For compressions, 97.5% of the BOTH caregivers were not successful in meeting the AHA compression guideline; however, an average of 238 compressions of the desired 240 were completed. None of the caregivers were successful in meeting the compression guideline using the NONE and MET interventions. This study demonstrates that use of metronomic tones by minimally-trained caregivers for coordinating both compressions and breaths improves 2CPR performance. Meeting the breath guideline is important to minimize air entering the stomach, thus decreasing the likelihood of gastric aspiration. These results suggest that manifesting a metronome for the ISS may augment the performance of 2CPR on orbit and thus may increase the level of care.

Hurst, Victor, IV↗

Free convection in enclosures exposed to compressive heating

An experimental study of heat transfer in a vertical annulus and a three-dimensional gap used to establish the influence of compressive heating on the convective process in enclosures is presented. Test runs were made using helium gas with compressive rates of 6, 15, and 30 psi/min. Temperature and pressure histories were reduced to film coefficients based on nodal modeling of the test geometries. The data are correlated in terms of free convection parameters. The heat transfer correlations show virtually no influence of compression rate and only a slight dependence on geometry. The correlations will be applied to the design of a vented Galileo mission descent module parachuting into the Jupiter atmosphere.

Bobco, R. P.↗

What Sets the Star Formation Rate of Molecular Clouds? The Density Distribution as a Fingerprint of Compression and Expansion Rates

We use a suite of 3D simulations of star-forming molecular clouds, with and without stellar feedback, magnetic fields, and driven turbulence, to study the compression and expansion rates of the gas as functions of density. We show that, around the mean density, supersonic turbulence promotes rough equilibrium between the amounts of compressing and expanding gas, consistent with continuous gas cycling between high- and low-density states. We find that the inclusion of protostellar jets produces rapidly expanding and compressing low-density gas. We find that the gas mass flux peaks at the transition between the lognormal and power-law forms of the density probability distribution function (PDF). This is consistent with the transition density tracking the post-shock density, which promotes an enhancement of mass at this density (i.e., shock compression and filament formation). At high densities, the gas dynamics are dominated by self-gravity: the compression rate in all of our runs matches the rate of the run with only gravity, suggesting that processes other than self-gravity have little effect at these densities. The net gas mass flux becomes constant at a density below the sink formation threshold, where it equals the star formation rate. The density at which the net gas mass flux equals the star formation rate is one order of magnitude lower than our sink threshold density, corresponds to the formation of the second power-law tail in the density PDF, and sets the overall star formation rates of these simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Lossless Compression and Rate Control for the Galileo NIMS Experiment

The Galileo Near-Infrared Mapping Spectrometer (NIMS) is a sophisticated multi-spectral instrument that was developed to study the spatial/compositional aspects of the atmosphere of Jupiter and the surfaces of it's satellites. Since its original development, the communication capability of the Galileo spacecraft has been severly reduced as the result of a failure of ground controllers to open the main antenna. The data rate which will be available for all instruments at the first Jupiter encounter in 1995 has been reduced by several orders of magnitude (even after recent numerous improvements to data link efficiency.).

data compression NIMS instrument Galileo↗

Formation of distinctive nanostructured metastable polymorphs mediated by kinetic transition pathways in germanium

High-pressure β -Sn germanium may transform into diverse metastable allotropes with distinctive nanostructures and unique physical properties via multiple pathways under decompression. However, the mechanism and transition kinetics remain poorly understood. Here, we investigate the formation of metastable phases and nanostructures in germanium via controllable transition pathways of β -Sn Ge under rapid decompression at different rates. High-resolution transmission electron microscopy reveals three distinct metastable phases with the distinctive nanostructures: an almost perfect st12 Ge crystal, nanosized bc8/r8 structures with amorphous boundaries, and amorphous Ge with nanosized clusters (0.8–2.5 nm). Fast in situ x-ray diffraction and x-ray absorption measurements indicate that these nanostructured products form in certain pressure regions via distinct kinetic pathways and are strongly correlated with nucleation rates and electronic transitions mediated by compression rate, temperature, and stress. This work provides deep insight into the controllable synthesis of metastable materials with unique crystal symmetries and nanostructures for potential applications.

36 MATERIALS SCIENCE↗

A High Performance Image Data Compression Technique for Space Applications

A highly performing image data compression technique is currently being developed for space science applications under the requirement of high-speed and pushbroom scanning. The technique is also applicable to frame based imaging data. The algorithm combines a two-dimensional transform with a bitplane encoding; this results in an embedded bit string with exact desirable compression rate specified by the user. The compression scheme performs well on a suite of test images acquired from spacecraft instruments. It can also be applied to three-dimensional data cube resulting from hyper-spectral imaging instrument. Flight qualifiable hardware implementations are in development. The implementation is being designed to compress data in excess of 20 Msampledsec and support quantization from 2 to 16 bits. This paper presents the algorithm, its applications and status of development.

Yeh, Pen-Shu↗

In situ compression artifact removal in scientific data using deep transfer learning and experience replay

The massive amount of data produced during simulation on high-performance computers has grown exponentially over the past decade, exacerbating the need for streaming compression and decompression methods for efficient storage and transfer of this data---key to realizing the full potential of large-scale computational science. Lossy compression approaches such as JPEG when applied to scientific simulation data realized as a stream of images can achieve good compression rates but at the cost of introducing compression artifacts and loss of information. This paper develops a unified framework for in situ compression artifact removal in which the fully convolutional neural network architectures are combined with scalable training, transfer learning, and experience replay to achieve superior accuracy and efficiency while significantly decreasing the storage footprint as compared with the traditional optimization-based approaches. We demonstrate the proposed approach and compare it with compressed sensing postprocessing and other baseline deep learning models using climate simulations and nuclear reactor simulations, both of which are driven by hyperbolic partial differential equations. Our approach when applied to remove the compression artifacts on the JPEG-compressed nuclear reactor simulation data (using a transfer-trained model that was pretrained on the climate simulation data and updated incrementally as the nuclear reactor simulation progressed), achieved a significant improvement---mean peak signal-to-noise ratio of 42.438 as compared with 27.725 obtained with the compressed sensing approach.

97 MATHEMATICS AND COMPUTING↗

A Real-Time High Performance Data Compression Technique For Space Applications

A high performance lossy data compression technique is currently being developed for space science applications under the requirement of high-speed push-broom scanning. The technique is also error-resilient in that error propagation is contained within a few scan lines. The algorithm is based on block-transform combined with bit-plane encoding; this combination results in an embedded bit string with exactly the desirable compression rate. The lossy coder is described. The compression scheme performs well on a suite of test images typical of images from spacecraft instruments. Hardware implementations are in development; a functional chip set is expected by the end of 2001.

Yeh, Pen-Shu↗

Block adaptive rate controlled image data compression

A block adaptive rate controlled (BARC) image data compression algorithm is described. It is noted that in the algorithm's principal rate controlled mode, image lines can be coded at selected rates by combining practical universal noiseless coding techniques with block adaptive adjustments in linear quantization. Compression of any source data at chosen rates of 3.0 bits/sample and above can be expected to yield visual image quality with imperceptible degradation. Exact reconstruction will be obtained if the one-dimensional difference entropy is below the selected compression rate. It is noted that the compressor can also be operated as a floating rate noiseless coder by simply not altering the input data quantization. Here, the universal noiseless coder ensures that the code rate is always close to the entropy. Application of BARC image data compression to the Galileo orbiter mission of Jupiter is considered.

Rice, R. F.↗

New dynamic diamond anvil cell for time-resolved radial x-ray diffraction

The dynamic diamond anvil cell (dDAC) is a recently developed experimental platform that has shown promise for studying the behavior of materials at strain rates ranging from intermediate to quasi-static and shock compression regimes. Combining dDAC with time-resolved x-ray diffraction (XRD) in the radial geometry (i.e., with incident x-rays perpendicular to the axis of compression) enables the study of material properties such as strength, texture evolution, and deformation mechanisms. This work describes a radial XRD dDAC setup at beamline P02.2 (Extreme Conditions Beamline) at DESY’s PETRA III synchrotron. Time-resolved radial XRD data are collected for titanium, zirconium, and zircon samples, demonstrating the ability to study the strength and texture of materials at compression rates above 300 GPa/s. In addition, the simultaneous optical imaging of the DAC sample chamber is demonstrated. The ability to conduct simultaneous radial XRD and optical imaging provides the opportunity to characterize plastic strain and deviatoric strain rates in the DAC at intermediate rates, exploring the strength and deformation mechanisms of materials in this regime.

47 OTHER INSTRUMENTATION↗