Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coherent beam combination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optically controlled single-valley exciton doublet states with tunable internal spin structures and spin magnetization generation

Manipulating quantum states through light–matter interactions has been actively pursued in two-dimensional materials research. Significant progress has been made toward the optical control of the valley degrees of freedom in semiconducting monolayer transition-metal dichalcogenides, based on doubly degenerate excitons from their two distinct valleys in reciprocal space. Here, we introduce a type of optically controllable doubly degenerate exciton states that come from a single valley, dubbed as single-valley exciton doublet (SVXD) states. They are unique in that their constituent holes originate from the same valence band, making possible the direct optical control of the spin structure of the excited constituent electrons. Combining ab initio GW plus Bethe–Salpeter equation ( GW -BSE) calculations and a theoretical analysis method, we demonstrate such SVXD in substrate-supported monolayer bismuthene—which has been successfully grown using molecular beam epitaxy. In each of the two distinct valleys in the Brillouin zone, strong spin–orbit coupling and C 3 v symmetry lead to a pair of degenerate 1s exciton states (the SVXD states) with opposite spin configurations. Any coherent linear combinations of the SVXD in a single valley can be excited by light with a specific polarization, enabling full manipulation of their internal spin configurations. In particular, a controllable net spin magnetization can be generated through light excitation. Our findings open routes to control quantum degrees of freedom, paving the way for applications in spintronics and quantum information science.

2D materials↗

Grazing-incidence X-ray diffraction tomography for characterizing organic thin films

Characterization of thin films is of paramount importance for evaluating material processing outcomes/efficiency as well as establishing structure–property/performance relationships. This article introduces grazing-incidence diffraction tomography (GID tomography), a technique that combines grazing-incidence X-ray scattering and computed tomography to quantitatively determine the dimension and orientation of crystalline domains in thin films without restrictions on the beam coherence, substrate type or film thickness. This computational method extends the capability of synchrotron beamlines by utilizing standard X-ray scattering experiment setups.

36 MATERIALS SCIENCE↗

Quantum vacuum processes in the extremely intense light of relativistic plasma mirror sources

Abstract The advent of petawatt-class laser systems allows generating electromagnetic fields of unprecedented strength in a controlled environment, driving increasingly more efforts to probe yet unobserved processes through their interaction with the quantum vacuum. Still, the lowest intensity scale governing these effects lies orders of magnitude beyond foreseen capabilities, so that such endeavor is expected to remain extremely challenging. In recent years, however, plasma mirrors have emerged as a promising bridge across this gap, by enabling the conversion of intense infrared laser pulses into coherently focused Doppler harmonic beams lying in the X-UV range. In this work, we present predictions on the quantum vacuum signatures produced when such beams are focused to intensities between 10 24 and 10 28 W cm −2 , specifically photon–photon scattering and electron–positron pair creation. These signatures are computed via the stimulated vacuum formalism, combined with a model of perfectly focused beam built from PIC-generated harmonics spectra, and implemented on state-of-the-art massively parallel numerical tools. In view of identifying experimentally favorable configurations, we also consider the coupling of the focused harmonic beam with an auxiliary optical beam, and provide comparison with other established schemes. Our results show that a single coherently focused harmonic beam can produce as much scattered photons as two infrared pulses in head-on collision, and confirm that the coupling of the harmonic beam to an auxiliary beam gives rise to significant levels of inelastic scattering, and hence holds the potential to strongly improve the attainable signal to noise ratios in experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overcoming energy limitation in post-compression of picosecond pulses by free beam propagation in air and temporal pulse splitting and recombining

Cryogenically cooled diode-pumped Yb:YAG has been demonstrated to efficiently generate pulses of >1 J energy and several picoseconds duration at a kilohertz repetition rate. Pulse broadening and post-compression techniques capable of operating at these high pulse energies will expand the use of these lasers in applications requiring shorter pulses. Towards this goal, we demonstrate the post-compression of 5.5 ps pulses with energy in the 0.1 J range by spectral broadening of self-collimated large area beams in air. In proof-of-principle experiments, pulses of 65 mJ energy from a cryogenically cooled Yb:YAG laser were compressed to 1.1 ps after 65 m propagation in a compact setup in which the beam was folded using flat mirrors. Further energy scaling was demonstrated by combining this spectral broadening technique with temporal pulse splitting and recombining. 120 mJ pulses were split into two pulses and coherently recombined with 85% efficiency after 50 m of propagation in air to yield 1.4 ps pulses.

High Energy Laser↗

Experimental exploration of compressed beam dynamics in an energy recovery linac with comparison to simulations

The compact energy recovery linac (cERL) has been developed for industrial applications since 2017. Applications such as free electron laser require a compressed beam with a small energy spread and transverse emittance. The typical operation energy of cERL is an intermediate energy region close to 17.5 MeV; therefore, the electron bunch is easily affected by the longitudinal space-charge effects and the coherent synchrotron radiation wakefield effects. Bunch compression is demonstrated by optimizing a combination of a longitudinally chirped electron bunch and the arcs with nonzero R 56 parameters. When the bunch compression procedure is applied for a bunch charge of 60 pC, an increase in energy spread is observed at the short bunch length. We systematically explored the chirp phase to determine the best condition. The measurement results of the energy spread, bunch length, and transverse emittance were compared with the tracking simulation results to understand the compressed beam dynamics.

47 OTHER INSTRUMENTATION↗

Coincident learning for beam-based rf station fault identification using phase information at the SLAC linac coherent light source

Anomalies in radio-frequency (rf) stations can result in unplanned downtime and performance degradation in linear accelerators such as SLAC’s Linac Coherent Light Source (LCLS). Detecting these anomalies is challenging due to the complexity of accelerator systems, high data volume, and scarcity of labeled fault data. Prior work identified faults using beam-based detection, combining rf amplitude and beam position monitor data. Due to the simplicity of the rf amplitude data, classical methods are sufficient to identify faults, but the recall is constrained by the low-frequency and asynchronous characteristics of the data. In this work, we leverage high-frequency, time-synchronous rf phase data to enhance anomaly detection in the LCLS accelerator. Due to the complexity of phase data, classical methods fail, and we instead train deep neural networks within the Coincident Anomaly Detection (CoAD) framework. We find that applying CoAD to phase data detects nearly 3 times as many anomalies as when applied to amplitude data, while achieving broader coverage across rf stations. Furthermore, the rich structure of phase data enables us to cluster anomalies into distinct physical categories. Through the integration of auxiliary system status bits, we link clusters to specific fault signatures, providing additional granularity for uncovering the root cause of faults. We also investigate interpretability via Shapley values, confirming that the learned models focus on the most informative regions of the data and providing insight for cases where the model makes mistakes. This work demonstrates that phase-based anomaly detection for rf stations improves both diagnostic coverage and root cause analysis in accelerator systems and that deep neural networks are essential for effective analysis.

Accelerator Physics (physics.acc-ph)↗

Strong–strong simulations of combined beam–beam and wakefield effects in the Electron–Ion-Collider

Collective wakefield and beam–beam effects play an important role in accelerator design and operation. These effects can cause beam instability, emittance growth, and luminosity degradation, and warrant careful study during accelerator design. In this paper, we studied the combined wakefield and beam–beam effects in an Electron Ion Collider design using strong–strong simulations. The simulation results show that the nonlinear beam–beam effects help suppress wakefield driven instability in the nominal working tune regime. In other tune regimes, the coherent beam–beam modes interact with the wakefields and cause a beam instability. The simulation results also show the importance of maintaining nominal crab cavity voltage. In conclusion, if the crab cavity voltage drops significantly the beam can become unstable.

43 PARTICLE ACCELERATORS↗

Increased spatial coherence length from an asymmetric crystal reflection at grazing exit

Coherent X-ray imaging is an active field at synchrotron sources. The images rely on the available coherent flux over a limited field of view. At many synchrotron beamlines a double-crystal monochromator (DCM) is employed in a standard nondispersive arrangement. For coherent diffraction imaging it is advantageous to increase the available field of view by increasing the spatial coherence length (SCL) of a beam exiting such a DCM. Here, Talbot interferometry data together with ray-tracing simulations for a (+ − − +) four-reflection experimental arrangement are presented, wherein the first two reflections are in the DCM and the final fourth reflection is asymmetric at grazing exit. Analyses of the interferometry data combined with the simulations show that compared with the beam exiting the DCM a gain of 76% in the SCL was achieved, albeit with a factor of 20 reduction in flux density, which may not be a severe penalty at a synchrotron beamline. Previous efforts reported in the literature to increase the SCL that employed asymmetric crystal diffraction at grazing incidence are also discussed. A much reduced SCL is found presently in simulations wherein the same asymmetric crystal is set for grazing incidence instead of grazing exit. In addition, the present study is compared and contrasted with two other means of increasing the SCL. These are (i) focusing the beam onto an aperture to act as a secondary source, and (ii) allowing the beam to propagate in vacuum an additional distance along the beamline.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hybrid molecular beam epitaxy of germanium-based oxides

Abstract Germanium-based oxides such as rutile GeO 2 are garnering attention owing to their wide band gaps and the prospects of ambipolar doping for application in high-power devices. Here, we present the use of germanium tetraisopropoxide (GTIP), a metal-organic chemical precursor, as a source of germanium for the demonstration of hybrid molecular beam epitaxy for germanium-containing compounds. We use Sn 1- x Ge x O 2 and SrSn 1- x Ge x O 3 as model systems to demonstrate our synthesis method. A combination of high-resolution X-ray diffraction, scanning transmission electron microscopy, and X-ray photoelectron spectroscopy confirms the successful growth of epitaxial rutile Sn 1- x Ge x O 2 on TiO 2 (001) substrates up to x = 0.54 and coherent perovskite SrSn 1- x Ge x O 3 on GdScO 3 (110) substrates up to x = 0.16. Characterization and first-principles calculations corroborate that germanium occupies the tin site, as opposed to the strontium site. These findings confirm the viability of the GTIP precursor for the growth of germanium-containing oxides by hybrid molecular beam epitaxy, thus providing a promising route to high-quality perovskite germanate films.

36 MATERIALS SCIENCE↗

Optical and microstructural characterization of Er 3+ doped epitaxial cerium oxide on silicon

Rare-earth ion dopants in solid-state hosts are ideal candidates for quantum communication technologies, such as quantum memories, due to the intrinsic spin–photon interface of the rare-earth ion combined with the integration methods available in the solid state. Erbium-doped cerium oxide (Er:CeO 2 ) is a particularly promising host material platform for such a quantum memory, as it combines the telecom-wavelength (~ 1.5 μm) 4f–4f transition of erbium, a predicted long electron spin coherence time when embedded in CeO 2 , and a small lattice mismatch with silicon. In this work, we report on the epitaxial growth of Er:CeO 2 thin films on silicon using molecular beam epitaxy, with controlled erbium concentration between 2 and 130 parts per million (ppm). We carry out a detailed microstructural study to verify the CeO 2 host structure and characterize the spin and optical properties of the embedded Er 3+ ions as a function of doping density. In as-grown Er:CeO 2 in the 2–3 ppm regime, we identify an EPR linewidth of 245(1) MHz, an optical inhomogeneous linewidth of 9.5(2) GHz, an optical excited state lifetime of 3.5(1) ms, and a spectral diffusion-limited homogeneous linewidth as narrow as 4.8(3) MHz. We test the annealing of Er:CeO 2 films up to 900 °C, which yields narrowing of the inhomogeneous linewidth by 20% and extension of the excited state lifetime by 40%.

36 MATERIALS SCIENCE↗

Demonstration of controlled spatial incoherence for beam smoothing

A concept for beam smoothing of high-energy laser systems is demonstrated. Multiple coherent beams are multiplexed so that their incoherent mix decreases the far-field nonuniformity after random spatial phase modulation introduced by a phase plate. Modeling shows that the incoherent mix effectively leads to the expected scaling in terms of the number of uncorrelated beams, and that spatial multiplexing can be combined with smoothing by spectral dispersion. The results of an experimental demonstration of this concept with up to six beams, leading to more than 40 modes with polarization multiplexing and angular dispersion, are consistent with expectations. The potential practical advantages of this smoothing scheme and future developments are discussed.

47 OTHER INSTRUMENTATION↗

Multitiered computational methodology for extracting three-dimensional rotational diffusion coefficients from x-ray photon correlation spectroscopy data without structural information

X-ray photon correlation spectroscopy (XPCS) is a powerful technique for analyzing particle systems by investigating their dynamics in suspensions across a broad range of temporal and spatial scales. This is done by illuminating samples with coherent x-ray beams and calculating the correlation function of the obtained x-ray scattering images. XPCS is uniquely suited for studying Brownian dynamics, consisting of translational and rotational diffusion. While traditional XPCS image analysis techniques can extract translational diffusion components, they are unable to estimate rotational diffusion coefficients. Here, we introduce a methodology that combines the angular-temporal cross-correlation analysis and a algorithmic framework called Multi-Tiered Estimation for Correlation Spectroscopy in 3D for estimating three-dimensional rotational diffusion coefficients from XPCS images of three-dimensional particle systems. We demonstrate our methodology for extracting rotational diffusion coefficients from XPCS data by applying it to simulated noisy x-ray images of systems of crossing nanotubes and proteins that evolve under translational and rotational Brownian motion for different diffusion rates. Furthermore, our results show that our approach determines rotational diffusion coefficients within a few percent error.

97 MATHEMATICS AND COMPUTING↗

Multi-qubit entanglement and algorithms on a neutral-atom quantum computer

Gate model quantum computers promise to solve currently intractable computational problems if they can be operated at scale with long coherence times and high fidelity logic. Neutral atom hyperfine qubits provide inherent scalability due to their identical characteristics, long coherence times, and ability to be trapped in dense multi-dimensional arrays. Combined with the strong entangling interactions provided by Rydberg states, all the necessary characteristics for quantum computation are available. Here we demonstrate several quantum algorithms on a programmable gate model neutral atom quantum computer in an architecture based on individual addressing of single atoms with tightly focused optical beams scanned across a two-dimensional array of qubits. Preparation of entangled Greenberger-Horne-Zeilinger (GHZ) states with up to 6 qubits, quantum phase estimation for a chemistry problem, and the Quantum Approximate Optimization Algorithm (QAOA) for the MaxCut graph problem are demonstrated. These results highlight the emergent capability of neutral atom qubit arrays for universal, programmable quantum computation, as well as preparation of non-classical states of use for quantum enhanced sensing.

97 MATHEMATICS AND COMPUTING↗

Mapping nanocrystal orientations via scanning Laue diffraction microscopy for multi-peak Bragg coherent diffraction imaging

The recent commissioning of a movable monochromator at the 34-ID-C endstation of the Advanced Photon Source has vastly simplified the collection of Bragg coherent diffraction imaging (BCDI) data from multiple Bragg peaks of sub-micrometre scale samples. Laue patterns arising from the scattering of a polychromatic beam by arbitrarily oriented nanocrystals permit their crystal orientations to be computed, which are then used for locating and collecting several non-co-linear Bragg reflections. The volumetric six-component strain tensor is then constructed by combining the projected displacement fields that are imaged using each of the measured reflections via iterative phase retrieval algorithms. Complications arise when the sample is heterogeneous in composition and/or when multiple grains of a given lattice structure are simultaneously illuminated by the polychromatic beam. Here, a workflow is established for orienting and mapping nanocrystals on a substrate of a different material using scanning Laue diffraction microscopy. The capabilities of the developed algorithms and procedures with both synthetic and experimental data are demonstrated. The robustness is verified by comparing experimental texture maps obtained with Laue diffraction microscopy at the beamline with maps obtained from electron back-scattering diffraction measurements on the same patch of gold nanocrystals. Such tools provide reliable indexing for both isolated and densely distributed nanocrystals, which are challenging to image in three dimensions with other techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Femtosecond multimodal imaging with a laser-driven X-ray source

Laser-plasma accelerators are compact linear accelerators based on the interaction of high-power lasers with plasma to form accelerating structures up to 1000 times smaller than standard radiofrequency cavities, and they come with an embedded X-ray source, namely betatron source, with unique properties: small source size and femtosecond pulse duration. A still unexplored possibility to exploit the betatron source comes from combining it with imaging methods able to encode multiple information like transmission and phase into a single-shot acquisition approach. In this work, we combine edge illumination-beam tracking (EI-BT) with a betatron X-ray source and present the demonstration of multimodal imaging (transmission, refraction, and scattering) with a compact light source down to the femtosecond timescale. The advantage of EI-BT is that it allows multimodal X-ray imaging technique, granting access to transmission, refraction and scattering signals from standard low-coherence laboratory X-ray sources in a single shot.

43 PARTICLE ACCELERATORS↗

Dark photons and axion-like particles at the electron-ion collider in China

The Electron-Ion Collider in China (EicC), a proposed high-luminosity facility with advanced charged particle and photon detection capabilities, provides unique opportunities to uncover new physics beyond the Standard Model. We analyze its sensitivity to dark photons produced through electron bremsstrahlung in coherent scattering. Thanks to its beam energy settings, it has the potential to comprehensively probe the previously unexplored parameter space between the constraints from meson decays and beam dumps below $\mathcal{O}(1)$ GeV with displaced-vertex search. Additionally, the EicC has the potential to probe axion-like particles (ALPs) in the mass range 0.1 GeV ≲ m a ≲ 5 GeV, with a coupling reach of Λ ≲ 10 6 GeV, by combining the prompt-decay and displaced-vertex searches. The projected sensitivities to ALPs exceed the current bounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status and new features of the topography beamline 1-BM after the Advanced Photon Source upgrade

The beamline 1-BM of the Advanced Photon Source (APS), a bending-magnet beamline with an effective X-ray beam size of ~100×4 mm2, has relatively comprehensive synchrotron topography and rocking curve imaging capabilities for characterization of crystals (particularly wide-bandgap semiconductors SiC, AlN, GaN, Ga2O3 etc). It is equipped with a white-beam topography stage for imaging large wafers up to 8 inches. It also has a double-crystal setup, of which the second stage can be used for monochromatic-beam topography. The first stage has different beam conditioners in the grazing-incidence geometry that can expand the vertical beam size from 4 to ~100 mm for double-crystal rocking curve imaging when it is combined with the second stage. Recently APS has been upgraded to a modern 4th-generation light source, and 1-BM has been recommissioned to its normal operation for general users with better performance. The upgraded APS leads to new features at 1-BM. The much smaller source size and higher X-ray coherence significantly improve the image resolution and contrast. The higher flux and brightness of the new source reduce exposure time, which mitigates the mechanical drifting and vibration issues. Here the main capabilities and status of 1-BM together with these new features are introduced.

X-ray topography↗

Stroboscopic ultrafast imaging using RF strip-lines in a commercial transmission electron microscope

The development of ultrafast electron microscopy (UEM), specifically stroboscopic imaging, has brought the study of structural dynamics to a new level by overcoming the spatial limitations of ultrafast spectroscopy and the temporal restrictions of traditional TEM simultaneously. Combining the concepts governing both techniques has enabled direct visualization of dynamics with spatiotemporal resolutions in the picosecond-nanometer regime. Here, in this study, we push the limits of imaging using a pulsed electron beam via RF induced transverse deflection based on the newly developed 200 keV frequency-tunable strip-line pulser. We demonstrate 0.2 nm spatial resolution at high magnifications and elucidation of Lorentz imaging using the phase-microscopy method. We also present beam coherence measurements and expand our study using the breathing modes of a silicon interdigitated comb under RF excitation which achieves improved temporal synchronization between the electron pulse-train and electric field. A new RF holder has also been developed with impedance matching to the RF signal to minimize transmission power loss to samples and its performance is compared with a conventional sample holder.

47 OTHER INSTRUMENTATION↗