Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coaxial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fabrication and Testing of a Stainless Steel Quartz Coaxial Cable Structure for High Temperature Measurement

This paper presents a stainless-steel quartz coaxial cable structure for distributed sensing of high temperatures. The coaxial cable sensor uses stainless steel as the inner and outer conductors and quartz as the insulator in order to achieve mechanical strength and temperature resilience. Girdle-shaped reflectors are fabricated on the quartz tubing by CNC grinding and CO 2 laser resurfacing. The sensor operates by measuring the temperature dependent change in the effective electromagnetic length between the two adjacent reflectors on the quartz tubing. A retaining collar is fabricated at the tip of the quartz tubing by 3D printing and laser resurfacing to secure the connection between the sensor and the signal cable. The prototype sensor was tested for high temperature measurements up to 600°C, and the performance characteristics of the sensor such as sensitivity, resolution uncertainty, repeatability, and stability were estimated based on the test results.

Jiao, Xinyu↗

Effect of Coaxial Electrode Geometry on the Electric Field Enhancement Factor for a High Voltage Vacuum Gap

We present an experimental analysis of the change in the electric field enhancement factor with varying gap size and penetration depth (P.D) of cathode into anode for a coaxial vacuum gap, diagnosed using Fowler–Nordheim analysis and optical imaging via scanning electron microscope (SEM) and time integrated Digital single lens reflex camera (DSLR). Data were collected on the Coaxial Gap Breakdown Machine (240 A, 25 kV, 150 ns, 0.1 Hz). Experiments using five different gap sizes at nine different P.Ds are compared over runs comprising 50 shots for each case. The results show a strong link between enhancement factor and gap size, with P.D and surface topology. For large gap sizes, 150, 330, and 700 μm, the average enhancement factor value increases with increasing P.D. For smaller gap sizes, 50 and 100 μm, the average enhancement factor decreases with P.D. SEM imaging before and after plasma formation for each gap size allows for quantifying surface finish, microprotrusion growth, average blast diameter, and an estimation of the surface area breakdowns occupy. Time integrated DSLR imaging analysis of the gap at each shot allows for a determination of the distribution of breakdowns about the circumference of the gap for each case tested. Here, the Fowler–Nordheim analysis allows for a quantitative analysis of the surface roughness of all gap sizes tested. Results show that for large gap sizes, the gap geometry and increasing area of breakdown is the main cause for increasing average enhancement factor. For small gap sizes, the dominant driving factor for small average enhancement factors—that subsequently decrease with P.D—is significant changes in surface topology due to an increased number of breakdowns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact Coaxial HOM Damper for SRF Cavities

SRF technology enable particle accelerators operate with greater average beam currents and higher duty cycles. In these regimes parasitic excitation of the cavity HOM spectrum become the limiting factor due to extra RF losses and instabilities appearing in the beam. We discuss the limitations of HOMs for large accelerator projects as the Fermilab MI upgrade and the proposed future circular and linear colliders EIC and ILC. A new compact HOM damper concept is suggested providing required HOM suppression. The idea is based on an oversized coaxial line with radial sections, which is directly connected to the axial region of the SRF cavity. Such radially sectioned coaxial works as a filter for the operating mode, while being transparent for the HOMs. Implementations of this design for the accelerator and crab cavities developed for the MI and EIC machines, respectively, are discussed.

Lunin, A. [Fermilab]↗

Optimized cryogenic setup for microwave loss characterization of superconducting coaxial cables

As superconducting quantum systems scale up to enable applications like large-scale quantum computing, challenges such as fabrication yield, wiring complexity, and microwave crosstalk drive the need for high-fidelity, low-loss, modular interconnects. In recent experiments, the performance of these interconnects is often limited by cable loss, a factor that becomes even more critical as we aim for higher fidelity operations and connect increasingly coherent modules. In this talk, we present our cryogenic microwave loss characterization setup, carefully designed to minimize losses external to the coaxial cables under test. We also share results for several commercially-available superconducting cables measured with this setup and briefly discuss our ongoing efforts to develop custom coaxial cables capable of achieving state-of-the-art performance.

Vallières, André [Northwestern U.]↗

Optimized cryogenic setup for microwave loss characterization of superconducting coaxial cables

As superconducting quantum systems scale up to enable applications like large-scale quantum computing, challenges such as fabrication yield, wiring complexity, and microwave crosstalk drive the need for high-fidelity, low-loss, modular interconnects. In recent experiments, the performance of these interconnects is often limited by cable loss, a factor that becomes even more critical as we aim for higher fidelity operations and connect increasingly coherent modules. In this talk, we present our cryogenic microwave loss characterization setup, carefully designed to minimize losses external to the coaxial cables under test. We also share results for several commercially-available superconducting cables measured with this setup and briefly discuss our ongoing efforts to develop custom coaxial cables capable of achieving state-of-the-art performance.

Vallières, André [Northwestern U.]↗

Impact of Nozzle Condition on Powder Catchment Efficiency for Coaxial Powder Direct Energy Deposition

Blown powder directed energy deposition is well-designed for fine resolution additive manufacturing processing. Coaxial powder deposition heads use an outer layer of shielding gas directed by an outer nozzle to prevent oxidation occurring during the powder melting process. Powder blown feedstock catchment efficiency can be as low as 50-80% whereas wire deposition systems are closer to 98% efficient. The present study evaluates the impact of directed energy deposition nozzle condition on catchment efficiency. Changes in the overall outer shielding gas nozzle length has been found to increase material usage efficiency by 10% through convergence of the powder flow. The results of this experiment show that for coaxial powder deposition head design, if the standoff distance can safely be decreased, powder catchment efficiency can be increased as the outer shielding gas nozzle is increased in length, or the standoff distance is decreased.

Heinrich, Lauren↗

Impact of Nozzle Condition on Powder Catchment Efficiency for Coaxial Powder Direct Energy Deposition

Blown powder directed energy deposition is well-designed for fine resolution additive manufacturing processing. Coaxial powder deposition heads use an outer layer of shielding gas directed by an outer nozzle to prevent oxidation occurring during the powder melting process. Powder blown feedstock catchment efficiency can be as low as 50-80% whereas wire deposition systems are closer to 98% efficient. The present study evaluates the impact of directed energy deposition nozzle condition on catchment efficiency. Changes in the overall outer shielding gas nozzle length has been found to increase material usage efficiency by 10% through convergence of the powder flow. The results of this experiment show that for coaxial powder deposition head design, if the standoff distance can safely be decreased, powder catchment efficiency can be increased as the outer shielding gas nozzle is increased in length, or the standoff distance is decreased.

Heinrich, Lauren↗

PyOECP: A flexible open-source software library for estimating and modeling the complex permittivity based on the open-ended coaxial probe (OECP) technique

Here, we present PyOECP, a Python-based flexible open-source software for estimating and modeling the complex permittivity obtained from the open-ended coaxial probe (OECP) technique. The transformation of the measured reflection coefficient to complex permittivity is performed based on three different methods. The software library contains the dielectric spectra of common reference liquids, which can be used to transform the reflection coefficient into the dielectric spectra. Several Python routines that are commonly employed (e.g., SciPy and NumPy) in the field of science and engineering are required only so that the users can alter the software structure depending on their needs. The modeling algorithm exploits the Markov Chain Monte Carlo method for the data regression. The discrete relaxation models can be built by a proper combination of well-known relaxation models. In addition to these models, electrode polarization, a typical measurement artifact for interpreting dielectric spectra, can be incorporated into the modeling algorithm. A continuous relaxation model, which solves the Fredholm integral equation of the first kind (a mathematically ill-posed problem), is also included. This open-source software enables users to freely adjust the physical parameters to obtain physical insight into their materials under test and will be consistently updated for more accurate measurement and interpretation of dielectric spectra in an automated manner. This work describes the theoretical and mathematical background of the software, lays out the workflow, and validates the software functionality based on both synthetic and empirical data included in the software.

97 MATHEMATICS AND COMPUTING↗

A metal-ceramic coaxial cable with multipoint Fabry-Pérot interferometers for monitoring distributed high temperature

A metal ceramic coaxial cable (MCCC) sensor containing multiple Fabry-Pérot interferometers (FPIs) has been designed, fabricated, and evaluated for measuring distributed high temperatures. The MCCC sensor demonstrated here consists of stainless steel tube and wire conductors, alumina tube insulator, and three pairs of air gap reflectors distributed along the cable. The multipoint sensor operation is realized by the joint time-frequency domain technique, which combines the functions of time-domain reflectometry and frequency division multiplexing to enable the measurement of spatially distributed temperature. The 3-point MCCC-FPI sensor has been demonstrated for distributed temperature measurements between 250 and 550 °C and operability up to 1000 °C. The sensor offers high sensitivity of >0.18 MHz/°C with a measurement resolution of 1 Hz and reasonably small high temperature measurement error range of ±3 °C.

42 ENGINEERING↗

Coaxial Nanowire Electrodes Enable Exceptional Fuel Cell Durability

Polymer-electrolyte-membrane fuel cells (PEMFCs) hold great promise for applications in clean energy conversion, but cost and durability continue to limit commercialization. This work presents a new class of catalyst/electrode architecture that does not rely on Pt particles or carbon supports, eliminating the primary degradation mechanisms in conventional electrodes, and thereby enabling transformative durability improvements. The coaxial nanowire electrode (CANE) architecture consists of an array of vertically aligned nanowires, each comprising an ionomer core encapsulated by a nanoscale Pt film. This unique design eliminates the triple-phase boundary and replaces it with two double-phase boundaries, increasing Pt utilization. It also eliminates the need for carbon support and ionomer binder, enabling improved durability and faster mass transport. Fuel cell membrane electrode assemblies based on CANEs demonstrate extraordinary durability in accelerated stress tests (ASTs), with only 2% and 5% loss in performance after 5000 support AST cycles and 30000 catalysts AST cycles, respectively. The high-power density and extremely high durability provided by CANEs can enable a paradigm shift from random electrodes based on unstable platinum nanoparticles dispersed on carbon to ordered electrodes based on durable Pt nanofilms, facilitating rapid deployment of fuel cells in transportation and other clean energy applications.

25 ENERGY STORAGE↗

Coaxial Direct Ink Writing of Cholesteric Liquid Crystal Elastomers in 3D Architectures

Abstract Cholesteric liquid crystal elastomers (CLCEs) hold great promise for mechanochromic applications in anti‐counterfeiting, smart textiles, and soft robotics, thanks to the structural color and elasticity. While CLCEs are printed via direct ink writing (DIW) to fabricate free‐standing films, complex 3D structures are not fabricated due to the opposing rheological properties necessary for cholesteric alignment and multilayer stacking. Here, 3D CLCE structures are realized by utilizing coaxial DIW to print a CLC ink within a silicone ink. By tailoring the ink compositions, and thus, the rheological properties, the cholesteric phase rapidly forms without an annealing step, while the silicone shell provides encapsulation and support to the CLCE core, allowing for layer‐by‐layer printing of self‐supported 3D structures. As a demonstration, free‐standing bistable thin‐shell domes are printed. Color changes due to compressive and tensile stresses can be witnessed from the top and bottom of the inverted domes, respectively. When the domes are arranged in an array and inverted, they can snap back to their base state by uniaxial stretching, thereby functioning as mechanical sensors with memory. The additive manufacturing platform enables the rapid fabrication of 3D mechanochromic sensors thereby expanding the realm of potential applications for CLCEs.

36 MATERIALS SCIENCE↗

Simons Observatory Microwave SQUID Multiplexing Readout: Cryogenic RF Amplifier and Coaxial Chain Design

The Simons Observatory (SO) is an upcoming polarization-sensitive cosmic microwave background experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of O(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiplexing factor of O(1000), microwave SQUID multiplexing has never been deployed on the scale needed for SO. Here we present the design of the cryogenic coaxial cable and RF component chain that connects room temperature readout electronics to superconducting resonators that are coupled to transition edge sensor bolometers operating at sub-Kelvin temperatures. We describe design considerations including cryogenic RF component selection, system linearity, noise, and thermal power dissipation.

47 OTHER INSTRUMENTATION↗

Coaxial color channel focus evaluation to estimate standoff height in directed energy deposition additive manufacturing

Directed energy deposition (DED) is an additive manufacturing process that is being rapidly adopted by industry and is well suited for the fabrication of complex components in a variety of metal alloys. In laser cladding systems such as DED, powder is blown in a stream to a metal substrate coincident with a laser necessary to deposit molten metal with 3D spatial control. The focus of both the laser and the powder stream are crucial, and best deposition occurs at a predetermined standoff height between the build surface and the print head. Generally, no monitoring of this distance is implemented in commercial DED systems. Due to potential over or under building, the standoff height often changes over time but tends to self-correct. However, inexpensive and minimally intrusive methods to identify optimal standoff are required to provide real-time control to maintain the optimal distance. The present work explores the quantification of the focus of the three-color channels of a coaxial camera to determine the standoff height. An experiment was performed in which a 254 mm wall is built and the standoff height, initially 5.0 mm below the optimal position, was then intentionally increased every 25.4 mm of wall length by an amount of 1.0 mm to a final position 7.0 mm above optimal. Computer vision is demonstrated to monitor the amount of focus in each color band and estimate standoff distance. Finally, a response can be calculated in under 40 ms using simple hardware and can work in most laser-based DED systems.

36 MATERIALS SCIENCE↗

First experimental measurements with the Segmented Inverted-coaxial GerMAnium (SIGMA) detector

The SIGMA project aims to develop a p-type segmented inverted coaxial point contact germanium detector for gamma-ray tracking and imaging. Here the performance of the first prototype of this type of detector is reported. The measurements performed verified the size and shape of the crystal and determined the location of the complex active volumes of the detector segments. The latter determines the charge collection times that are related to the position of interaction. Good agreement is found between the results and the specified crystal design. The energy resolution of the point contact has been measured to be 0.84 keV and 2.21 keV at 122 keV and 1332 keV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of a central barrier potential on asymmetry-induced transport in a coaxial Malmberg–Penning trap

Experiments are presented measuring the radial particle flux produced when a central barrier potential is applied to the central ring of a coaxial Malmberg-Penning trap at the same time as the voltages producing the main asymmetry potential $\phi_1(r)\cos{(kz)}\cos{(l\theta-\omega t)}$. When a negative DC voltage is applied to the entire central ring, the peak flux produced by the main asymmetry is reduced by a factor $e^{(V_{eff}/1.2)}$ where $V_{eff}$ is the effective applied potential in volts. This barrier potential also increases the frequency of this peak flux. When asymmetric $\pm$ voltages are applied to the two azimuthally-divided halves of the central ring, DC voltages increase the radial flux while AC voltages decrease it. It is shown that these asymmetric barrier voltages produce their own transport and that the resulting modification of the plasma may be a factor in changing the observed flux.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Niobium coaxial cavities with internal quality factors exceeding 1.4 × 10 9 for circuit quantum electrodynamics

Group-V materials such as niobium and tantalum have become popular choices for extending the performance of circuit quantum electrodynamics (cQED) platforms, allowing for quantum processors and memories with reduced error rates and more modes. The complex surface chemistry of niobium, however, makes identifying the main modes of decoherence difficult at millikelvin temperatures and single-photon powers. We use niobium coaxial quarter-wave cavities to study the impact of etch chemistry, prolonged atmospheric exposure, and the significance of cavity conditions prior to and during cooldown—in particular, niobium hydride evolution—on single-photon coherence. We demonstrate cavities with quality factors Q int ≳ 1.4 × 10 9 in the single-photon regime, a 15-fold improvement over aluminum cavities of the same geometry. We rigorously quantify the sensitivity of our fabrication process to various loss mechanisms and demonstrate a two- to fourfold reduction in the two-level system loss tangent and a three- to fivefold improvement in the residual resistance over traditional buffered chemical polishing etching techniques. Finally, we demonstrate transmon integration and coherent cavity control while maintaining a cavity coherence of 11.3 ms. The accessibility of our method, which can be easily replicated in academic laboratory settings, together with the demonstration of its performance, mark an advancement in three-dimensional cQED.

Oriani, Andrew E. [Chicago U., EFI; Chicago U.] (O↗

First Axionlike Particle Results from a Broadband Search for Wavelike Dark Matter in the 44 to 52 μ ⁢eV Range with a Coaxial Dish Antenna

We present the results from the first axionlike particle search conducted using a dish antenna. The experiment was conducted at room temperature and sensitive to axionlike particles in the 44–52 μ ⁢eV range (10.7–12.5 GHz). The novel dish antenna geometry was proposed by the BREAD Collaboration and previously used to conduct a dark photon search in the same mass range. To allow for axionlike particle sensitivity, the BREAD dish antenna was placed in a 3.9 T solenoid magnet at Argonne National Laboratory. In the presence of a magnetic field, axionlike dark matter converts to photons at the conductive surface of the reflector. The signal is focused onto a custom coaxial horn antenna and read out with a low-noise radio-frequency receiver. No evidence of axionlike dark matter was observed in this mass range and we place the most stringent laboratory constraints on the axion-photon coupling strength, 𝑔 𝑎⁢𝛾⁢𝛾 , in this mass range at 90% confidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coaxial laser absorption and optical emission spectroscopy of high-pressure aluminum monoxide

This work advances laser absorption spectroscopy with measurements of aluminum monoxide (AlO) temperature and column density in extreme pressure ( P > 60 bar) and temperature ( T > 4000 K) environments. Measurements of the AlO A 2 Π i – X 2 Σ + transition are made using a microelectromechanical system, tunable vertical cavity surface emitting laser (MEMS-VCSEL). Simultaneous emission measurements of the AlO B 2 Σ + – X 2 Σ + transition are made along a line of sight that is coaxial with the laser absorption. Absorption temperature fits agree with emission spectra for a T = 3200 K, P = 9 bar case. In cases with T > 4000 K, P > 60 bar, absorption fits match the ambient temperature while emission fits over-estimate it, owing to high optical depths. These data juxtapose passive and active spectroscopic methods and demonstrate the versatility of AlO laser absorption in high-pressure and high-temperature environments where experimental data remain scarce, and engineering models will benefit from refined measurements.

Daniel, K. A.↗