SEARCH · Engineering Papers
Results for “clamp”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Structural Basis for the Improved RNA Clamping of Amidino-Rocaglates to eIF4A1
Not provided.
Investigation of Limitations in Passive Voltage Clamping-Based Solid-State DC Circuit Breakers
Not Available
High Frequency Active-Clamped Zero-Current Switching Current-Fed Push-Pull Converter for Micro-Converter Applications
Explore the source record for details and available documents.
Direct Observation of a Cytosine Analogue that Forms Five Hydrogen Bonds to Guanosine: Guanidino G-Clamp
Abstract not provided
IMPROVED FRACTURE TOUGHNESS TEST METHOD FOR SINGLE EDGE NOTCHED TENSION SPECIMENS IN CLAMPED-END CONDITIONS
Explore the source record for details and available documents.
CMOD COMPLIANCE SOLUTION DETERMINED BY STRESS INTENSITY FACTORFOR SINGLE EDGE NOTCHED TENSION SPECIMENS IN END-CLAMPED CONDITIONS
Explore the source record for details and available documents.
Real-time patch-clamp sensing of transport across a barrier tissue
The present disclosure relates to methods, apparatuses, and systems to measure one or more electrical signals from a cultured cell layer. In some embodiments, such electrical signals can be indicative of transport or lack of transport of an agent through the cell layer.
The role of lattice dynamics in ferroelectric switching
Reducing the switching energy of ferroelectric thin films remains an important goal in the pursuit of ultralow-power ferroelectric memory and logic devices. Here, we elucidate the fundamental role of lattice dynamics in ferroelectric switching by studying both freestanding bismuth ferrite (BiFeO 3 ) membranes and films clamped to a substrate. We observe a distinct evolution of the ferroelectric domain pattern, from striped, 71° ferroelastic domains (spacing of ~100 nm) in clamped BiFeO 3 films, to large (10’s of micrometers) 180° domains in freestanding films. By removing the constraints imposed by mechanical clamping from the substrate, we can realize a ~40% reduction of the switching voltage and a consequent ~60% improvement in the switching speed. Our findings highlight the importance of a dynamic clamping process occurring during switching, which impacts strain, ferroelectric, and ferrodistortive order parameters and plays a critical role in setting the energetics and dynamics of ferroelectric switching.
Exploring mounting solutions for cryogenically cooled thin crystal optics in high power density x-ray free electron lasers
This study investigates three mounting methods—clamping, soldering, and a hybrid clamping–soldering approach—for cryogenically cooled thin diamond crystals crucial to stable operation of X-ray Free Electron Laser (XFEL) systems. While clamping methods exhibit temperature resilience and flexibility, meticulous design is required to prevent stress-induced warping and reduce thermal contact area. Soldering methods offer reliable mechanical and thermal bonding but encounter challenges due to the coefficient of thermal expansion mismatch at cryogenic temperatures. The hybrid method, integrating clamping and soldering with strain relief cuts, effectively mitigates overall distortion caused by mounting and XFEL thermal loads. These findings offer a novel mounting solution for high-performance x-ray optics in XFEL research and applications, ensuring stability and optimal functionality in cryogenic conditions.
Confinement in electron heated plasmas in Wendelstein 7-X and ASDEX Upgrade; the necessity to control turbulent transport
In electron (cyclotron) heated plasmas, in both ASDEX Upgrade (L-mode) and Wendelstein 7-X, clamping of the ion temperature occurs at $T_\mathrm{i}$ ~ 1.5 keV independent of magnetic configuration. The ions in such plasmas are heated through the energy exchange power as ${n}_{\mathrm{e}}^{2}({T}_{\mathrm{e}}-{T}_{\mathrm{i}})/{T}_{\mathrm{e}}^{3/2}$, which offers a broad ion heating profile, similar to that offered by alpha heating in future thermonuclear fusion reactors. However, the predominant electron heating may put an additional constraint on the ion heat transport, as the ratio $T_\mathrm{e}T_\mathrm{i}$ > 1 can exacerbates ITG/TEM core turbulence. Therefore, in practical terms the strongly 'stiff' core transport translates into Ti-clamping in electron heated plasmas. Due to this clamping, electron heated L-mode scenarios, with standard gas fueling, in either tokamaks or stellarators may struggle to reach high normalized ion temperature gradients required in a compact fusion reactor. The comparison shows that core heat transport in neoclassically optimized stellarators is driven by the same mechanisms as in tokamaks. The absence of a strong H-mode temperature edge pedestal in stellarators, sofar (which, like in tokamaks, could lift the clamped temperature-gradients in the core), puts a strong requirement on reliable and sustainable core turbulence suppression techniques in stellarators.
A Threshold Helium Leakage Detection Switch with Ultra Low Power Operation
Detecting helium leakage is important in many applications, such as in dry cask nuclear waste storage systems. This work develops a helium detection system based on the relative permittivity (dielectric constant) difference between air and helium. This difference changes the status of an electrostatic microelectromechanical system (MEMS) switch. The switch is a capacitive-based device and requires a very negligible amount of power. Exciting the switch’s electrical resonance enhances the MEMS switch sensitivity to detect low helium concentration. This work simulates two different MEMS switch configurations: a cantilever-based MEMS modeled as a single-degree-freedom model and a clamped-clamped beam MEMS molded using the COMSOL Multiphysics finite-element software. While both configurations demonstrate the switch’s simple operation concept, the clamped-clamped beam was selected for detailed parametric characterization due to its comprehensive modeling approach. The beam detects at least 5% helium concentration levels when excited at 3.8 MHz, near electrical resonance. The switch performance decreases at lower excitation frequencies or increases the circuit resistance. The MEMS sensor detection level was relatively immune to beam thickness and parasitic capacitance changes. However, higher parasitic capacitance increases the switch’s susceptibility to errors, fluctuations, and uncertainties.
Nuclear thermal propulsion fuel element packing device
A packing device for filling fuel elements with a powder through a fill aperture in an outer shell of the fuel element, including a stationary base, a clamp assembly including a body defining a bore therein, the bore being configured to slidably receive a fuel element therein, wherein the clamp assembly is movable along a vertical axis with respect to the stationary base, a cam assembly including a cam and a drive motor configured to rotate the cam, wherein rotation of the cam alternatingly raises the clamp assembly up along the vertical axis and subsequently drops the clamping assembly, and a powder reservoir assembly including a powder reservoir and a fill needle in fluid communication with the powder reservoir.
Pulse generator
A pulse shaping device includes an inductor that is selectively output-coupled to a first port of a capacitor. The inductor is charged to a selected current throughput and then coupled to the first port to generate a first characteristic within the current flowing at a second port of the capacitor. The capacitor is charged until reaching a clamping voltage at the first port. A voltage clamp of the shaping device clamps the first port of the capacitor at the clamping voltage to generate a second characteristic within the current flowing at a second port of the capacitor.
Fluorescence-coupled micropipette aspiration assay to examine calcium mobilization caused by red blood cell mechanosensing
Abstract Mechanical stimuli such as tension, compression, and shear stress play critical roles in the physiological functions of red blood cells (RBCs) and their homeostasis, ATP release, and rheological properties. Intracellular calcium (Ca 2+ ) mobilization reflects RBC mechanosensing as they transverse the complex vasculature. Emerging studies have demonstrated the presence of mechanosensitive Ca 2+ permeable ion channels and their function has been implicated in the regulation of RBC volume and deformability. However, how these mechanoreceptors trigger Ca 2+ influx and subsequent cellular responses are still unclear. Here, we introduce a fluorescence-coupled micropipette aspiration assay to examine RBC mechanosensing at the single-cell level. To achieve a wide range of cell aspirations, we implemented and compared two negative pressure adjusting apparatuses: a homemade water manometer (− 2.94 to 0 mmH 2 O) and a pneumatic high-speed pressure clamp (− 25 to 0 mmHg). To visualize Ca 2+ influx, RBCs were pre-loaded with an intensiometric probe Cal-520 AM, then imaged under a confocal microscope with concurrent bright-field and fluorescent imaging at acquisition rates of 10 frames per second. Remarkably, we observed the related changes in intracellular Ca 2+ levels immediately after aspirating individual RBCs in a pressure-dependent manner. The RBC aspirated by the water manometer only displayed 1.1-fold increase in fluorescence intensity, whereas the RBC aspirated by the pneumatic clamp showed up to threefold increase. These results demonstrated the water manometer as a gentle tool for cell manipulation with minimal pre-activation, while the high-speed pneumatic clamp as a much stronger pressure actuator to examine cell mechanosensing directly. Together, this multimodal platform enables us to precisely control aspiration and membrane tension, and subsequently correlate this with intracellular calcium concentration dynamics in a robust and reproducible manner.