The chemical analysis experiment for the Surveyor lunar mission
Alpha particle detector experiment for chemical analysis of lunar surface by Surveyor spacecraft
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Alpha particle detector experiment for chemical analysis of lunar surface by Surveyor spacecraft
An alpha particle experiment similar to the one performed successfully on the Surveyor lunar missions is described. It is designed to provide a chemical analysis of the Martian surface and atmosphere. Analyses of rocks of known and unknown compositions have been made under simulated Martian conditions. The accuracies attained are generally comparable to those of the Surveyor lunar analyses. Improvements have been achieved in determining carbon and oxygen, so that a few per cent of water or carbonates in rocks can be detected. Some aspects of the integration of such an experiment with the spacecraft, a possible mission profile, and some other problems associated with a soft-landing mission to Mars are discussed. The importance of such a chemical analysis experiment in answering current questions about the nature and history of Martian surface material and its suitability for life processes is presented.
Preliminary results of chemical analysis of moon at Surveyor 7 landing site
Instrument automatically performs a nondestructive chemical analysis of surfaces and transmits the data in the form of electronic signals. It employs solid-state nuclear particle detectors with a charged nuclear particle source and an electronic pulse-height analyzer.
Chemical analysis of moon at Surveyor 5 landing site
Chemical analysis of hydroxyl in solid magnesium oxide using chemical decomposition and emission and mass spectrographic techniques
Chemical analysis of lunar surface at Surveyor 5 landing site
Nonvolatile residue (NVR), sometimes referred to as molecular contamination is the term used for the total composition of the inorganic and high boiling point organic components in particulates and molecular films deposited on critical surfaces surrounding space structures, with the particulate and NVR contamination originating primarily from pre-launch operations. The "nonvolatile" suggestion from the terminology NVR implies that the collected residue will not experience much loss under ambient conditions. NVR has been shown to have a dramatic impact on the ability to perform optical measurements from platforms based in space. Such contaminants can be detected early by the controlled application of various detection techniques and contamination analyses. Contamination analyses are the techniques used to determine if materials, components, and subsystems can be expected to meet the performance requirements of a system. Of particular concern is the quantity of NVR contaminants that might be deposited on critical payload surfaces from these sources. Subsequent chemical analysis of the contaminant samples by infrared spectroscopy and gas chromatography mass spectrometry identifies the components, gives semi-quantitative estimates of contaminant thickness, indicates possible sources of the NVR, and provides guidance for effective cleanup procedures. In this report, a method for the collection and determination of the mass of NVR was generated by the authors at NASA Langley Research Center. This report describes the method developed and implemented for collecting NVR contaminants, and procedures for gravimetric and chemical analysis of the residue obtained. The result of this NVR analysis collaboration will help pave the way for Langley's ability to certify flight hardware outgassing requirements in support of flight projects such as Stratospheric Aerosol and Gas Experiment III (SAGE III), Clouds and the Earth's Radiant Energy System (CERES), Materials International Space Station Experiment - X (MISSE-X), and Doppler Aerosol Wind Lidar (DAWN).
Chemical analysis of lunar surface at Surveyor 7 Tycho landing site
Chemical analysis of moon at Surveyor 7 landing site from alpha particle scattering
Chemical analysis of adsorbates from breathing canisters of Apollo 10 spacecraft
Regular arrays of 1 inch discs cut from chemically impregnated positive and negative plates were sent to various contractors and government organizations for chemical analysis in order to determine whether there is consistency in analysis. Techniques used included NASA procedures as specified, variations, wet chemical techniques, and atomic absorption. The weight, thickness of disc, and active material quantity as measured by four respondents are discussed.
Chemical analysis techniques developed to determine elemental impurities in magnesium oxides
The results of analyses by ESCA (Electron Spectroscopy for Chemical Analysis) on several Nuclepore filters which were exposed during air pollution studies are presented along with correlative measurements by Neutron Activation Analysis and Scanning Electron Microscopy. Samples were exposed during air pollution studies at Norfolk, Virginia and the NASA Kennedy Space Center (KSC). It was demonstrated that with the ESCA technique it was possible to identify the chemical (bonding) state of elements contained in the atmospheric particulate matter collected on Nuclepore filters. Sulfur, nitrogen, mercury, chlorine, alkali, and alkaline earth metal species were identified in the Norfolk samples. ESCA binding energy data for aluminum indicated that three chemically different types of aluminum are present in the launch and background samples from NASA-KSC.
Moon surface chemical analysis by Surveyor 6 indicating resemblance to basalt in composition
Lunar surface chemical composition analysis by Surveyor-borne instrument based on alpha interaction with matter
The Performance Monitoring Report presents the Year 2 operations, maintenance, and monitoring (OM&M) activities for the hydraulic containment system (HCS) Interim Measures (IM) at the Components Refurbishment and Chemical Analysis (CRCA) Facility located at John F. Kennedy Space Center (KSC), Florida. Year 2 operations extended from September 2020 to August 2021 and included: operation, maintenance and monitoring of the HCS; performance monitoring through collection of groundwater samples; and sub-slab gas and ambient air sampling. The existing hydrogeologic model was also updated. The system is performing as designed, and groundwater data demonstrate contaminant reduction.
During the 2-year span from Expedition 16 through Expedition 20, the chemical quality of the potable water onboard the International Space Station (ISS) was verified safe for crew consumption through the return and chemical analysis of archival water samples by the Water and Food Analytical Laboratory (WAFAL) at Johnson Space Center (JSC). Reclaimed cabin humidity condensate and Russian ground-supplied water were the principal sources of potable water for Expeditions 16 through 18. During Expedition 18 the U.S. water processor assembly was delivered, installed, and tested during a 90-day checkout period. Beginning with Expedition 19, U.S. potable water recovered from a combined waste stream of humidity condensate and pretreated urine was also available for ISS crew use. A total of 74 potable water samples were collected using U.S. sampling hardware during Expeditions 16 through 20 and returned on both Shuttle and Soyuz vehicles. The results of JSC chemical analyses of these ISS potable water samples are presented in this paper. Eight potable water samples collected in flight with Russian hardware were also received for analysis, as well as 5 preflight samples of Rodnik potable water delivered to ISS on Russian Progress vehicles 28 to 34. Analytical results for these additional potable water samples are also reported and discussed.