Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “charged particle optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Improved heavy-ion PID using scintillation light detector with neural network analysis: a Monte Carlo simulation study

The photon collection efficiency of gaseous scintillator detectors varies according to the position of the impinging charged particles in the medium that generates scintillation light. Thus, when impinging particles are distributed over a large area, the intrinsic photon-number resolution of the system is affected by a large variation. This work presents and discusses a method for adjusting the total number of detected photons to account for variation in the photon collection efficiency as a function of the position of the light source within the scintillating medium. The method was developed and validated by processing data from systematic simulation studies based on GEANT4 that model the response of the Energy Loss Optical Scintillation System (ELOSS) detector. The position of the charged particle is calculated using a deep neural network algorithm. This is accomplished by analyzing the distribution of scintillation light recorded by the array of photosensors. The estimated particle position is then used to calculate the correction factor and adjust the amount of captured light to account for variations in the photon collection efficiency. The neural network algorithm provides excellent tracking capabilities, achieving sub-millimeter position resolution and an angular resolution of 12 mrad, approaching the performance of traditional tracking detectors (e.g., drift chambers). The present method can be generalized to any optical scintillation system where the photon collection efficiency depends on the position of the impinging particle.

Heavy-ion detectors↗

Attosecond probing and control of charge migration in carbon-chain molecule

In quantum mechanics, when an electron is quickly ripped off from a molecule, a superposition of new eigenstates of the cation creates an electron wave packet that governs the charge flow inside, which has been called charge migration (CM). Experimentally, extracting such dynamics at its natural (attosecond) timescale is quite difficult. We report the first such experiment in a linear carbon-chain molecule, butadiyne (C 4 H 2 ), via high-harmonic spectroscopy (HHS). By employing advanced theoretical and computational tools, we showed that the wave packet and the CM of a single molecule are reconstructed from the harmonic spectra for each fixed-in-space angle of the molecule. For this one-dimensional molecule, we calculate the center of charge $\langle$ x $\rangle$ ( t ) to obtain v cm , to quantify the migration speed and how it depends on the orientation angle. The findings also uncover how the electron dynamics at the first few tens to hundreds of attoseconds depends on molecular structure. The method can be extended to other molecules where the HHS technique can be employed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental demonstration of optical stochastic cooling

Particle accelerators and storage rings have been transformative instruments of discovery, and, for many applications, innovations in particle-beam cooling have been a principal driver of that success. Stochastic cooling (SC), one of the most important conceptual and technological advances in this area cools a beam through granular sampling and correction of its phase-space structure, thus bearing resemblance to a ‘Maxwell’s demon’. The extension of SC from the microwave regime up to optical frequencies and bandwidths has long been pursued, as it could increase the achievable cooling rates by three to four orders of magnitude and provide a powerful tool for future accelerators. First proposed nearly 30 years ago, optical stochastic cooling (OSC) replaces the conventional microwave elements of SC with optical-frequency analogues and is, in principle, compatible with any species of charged-particle beam. Here we describe a demonstration of OSC in a proof-of-principle experiment at the Fermi National Accelerator Laboratory’s Integrable Optics Test Accelerator. The experiment used 100-MeV electrons and a non-amplified configuration of OSC with a radiation wavelength of 950 nm, and achieved strong, simultaneous cooling of the beam in all degrees of freedom. This realization of SC at optical frequencies serves as a foundation for more advanced experiments with high-gain optical amplification, and advances opportunities for future operational OSC systems with potential benefit to a broad user community in the accelerator-based sciences.

43 PARTICLE ACCELERATORS↗

Mechanical Detection of Nuclear Decays

We report the detection of individual nuclear alpha decays through the mechanical recoil of the entire micron-sized particle in which the decaying nuclei are embedded. Momentum conservation ensures that such measurements are sensitive to any particles emitted in the decay, including neutral particles that may otherwise evade detection with existing techniques. Detection of the minuscule recoil of an object more than 10^12 times more massive than the emitted particles is made possible by recently developed techniques in levitated optomechanics, which enable high-precision optical control and measurement of the mechanical motion of optically trapped particles. Observation of a change in the net charge of the particle coincident with the recoil allows decays to be identified with background levels at the micro-Becquerel level. Here, the techniques developed here may find use in fields ranging from nuclear forensics to dark matter and neutrino physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical versus radiographic imaging and tomography: introduction to the ROADS feature issue

Optical imaging is an ancient branch of imaging dating back to thousands of years. Radiographic imaging and tomography (RadIT), including the first use of X-rays by Wilhelm Röntgen, and then, $γ$ -rays, energetic charged particles, neutrons, etc. are about 130 years young. The synergies between optical and radiographic imaging can be cast in the framework of these building blocks: Physics, Sources, Detectors, Methods, and Data Science, as described in Appl. Opt. 61, RDS1 (2022). Optical imaging has expanded to include three-dimensional (3D) tomography (including holography), due in to part the invention of optical (including infrared) lasers. RadIT are intrinsically 3D because of the penetrating power of ionizing radiation. Both optical imaging and tomography (OIT) and RadIT are evolving into even higher dimensional regimes, such as time-resolved tomography (4D) and temporarily and spectroscopically resolved tomography (4D + ). Further advances in OIT and RadIT will continue to be driven by desires for higher information yield, higher resolutions, and higher probability models with reduced uncertainties. Synergies in quantum physics, laser-driven sources, low-cost detectors, data-driven methods, automated processing of data, and artificially intelligent data acquisition protocols will be beneficial to both branches of imaging in many applications. These topics, along with an overview of the Radiography, Applied Optics, and Data Science virtual feature issue, are discussed here.

47 OTHER INSTRUMENTATION↗

Nonlinear integrable optics beam dynamics experiment and diagnostics

All present circular particle accelerators are built around linear focusing optics. Un-avoidable nonlinear elements appear in accelerators, such as magnetic aberrations and space-charge effects, which are typically corrected using nonlinear magnets. However, these added nonlinearities degrade particle beam stability, and in most cases, the system becomes non-integrable. The Integrable Optics Test Accelerator (IOTA), at Fermi National Accelerator Laboratory (Fermilab), is a test bed to study beam dynamics in integrable lattices for both electron and proton beams, independently. This work presents experimental results of the nonlinear electron beam dynamics behavior in IOTA using an elliptical nonlinear magnet. The elliptical nonlinear magnet allows for a large betatron tune spread, allowing for a stable high-intensity beam. In a future experimental run, minimally invasive beam instrumentation is needed to study time-dependent collective instabilities, and halo formation in space-chargedominated proton beams. Traditional profile monitors are too destructive to the beam or just measure one dimension of the beam. A gas sheet can be injected perpendicular to theproton beam at an angle. By doing so, a two-dimensional, turn-by-turn, transverse profile measurement can be made, which will preserve the integrity of the beam. The developmentand progress of a gas sheet beam profile monitor will also be presented.

43 PARTICLE ACCELERATORS↗

Optical and transport properties of plasma mixtures from ab initio molecular dynamics

Predicting the charged particle transport properties of warm dense matter/hot dense plasma mixtures is a challenge for analytical models. High accuracy ab initio methods are more computationally expensive, but can provide critical insight by explicitly simulating mixtures. In this work, we investigate the transport properties and optical response of warm dense carbon–hydrogen mixtures at varying concentrations under either conserved electronic pressure or mass density at a constant temperature. We compare options for mixing the calculated pure species properties to estimate the results of the mixtures. We find that a combination of the Drude model with the Matthiessen's rule works well for DC electron transport and low-frequency optical response. This breaks down at higher frequencies, where a volumetric mix of pure-species AC conductivities works better.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interplay of intercalation dynamics and lithium plating in monolithic and architectured graphite anodes during fast charging

Fast charging of high-capacity anodes is challenging due to lithium plating reactions, which lead to poor cycling performance and safety concerns. Thus, accurate predictions of plating onset and an understanding of this electrochemical process are crucial for robust battery design. However, the most commonly used models, based on porous electrode theory (e.g., the pseudo-2D model), are notoriously difficult to calibrate due to their complexity, limiting their predictive power. This work studies the process of lithium plating during fast charging of (small-particle) graphite half-cells by measuring local reaction progression and plating behavior using optical operando techniques. These experiments employ a realistic 1D graphite electrode geometry with commercially-relevant mass loading charged at fast charge rates. It is demonstrated that the local reaction progression and plating onset can not only be predicted accurately with a p2D numerical model, but that these processes follow a simple scaling law. Remarkably, the entire reaction histories of different electrodes charged at different rates (e.g., 160 μm thickness at 0.5C, 111 μm at 1C or 66 μm at 4C) were observed to have self-similar intercalation profiles. It is demonstrated that plating onset is in turn governed by the reaction profile which explains why both processes exhibit the same scaling behavior. Finally, operando measurements of local reaction dynamics are conducted for the first time in electrodes with channeled architectures, quantitatively determining how channels affect reaction uniformity and plating onset. Together, these results reveal underlying simplicity in the complex electrochemical environment of fast charging and lithium plating, improving understanding of this process. These fundamental insights are broadly applicable for design processes, modeling and experimental evaluation of lithium ion batteries.

25 ENERGY STORAGE↗

Light detection and cosmic rejection in the ICARUS LArTPC at Fermilab

Abstract The ICARUS-T600 detector is a 760-ton Liquid Argon Time Projection Chamber (LArTPC) currently operating at Fermilab as the Far Detector in the Short Baseline Neutrino (SBN) program. The SBN program is composed of three LArTPCs with a central goal of testing the sterile neutrino hypothesis. After operating for 3-years in the Gran Sasso Underground Laboratory, the ICARUS detector was shipped to CERN where it was outfitted with 360 8” Photomultiplier Tubes (PMTs) for a new optical detection system. The PMT system detects fast scintillation light from charged particles interacting in the Liquid Argon, generating the trigger signal for the full detector and allows 3D reconstruction of events. Now operating at shallow depth, the detector is exposed to a high flux of cosmic rays that can fake neutrino interactions. To mitigate this effect a Cosmic Ray Tagger (CRT) and a 3-meter-thick concrete were installed. Precise timing information from both the PMT and CRT subsystems can help to identify whether an interaction originated from inside or outside of the ICARUS cryostat. This paper reviews a method for cosmogenic background reduction and timing calibration of the CRT and PMT light detection systems in ICARUS.

Instruments & Instrumentation↗

Dynamics near equilibrium for intense beams in a nonlinear integrable focusing channel

Accelerator storage ring designs based on nonlinear integrable Hamiltonian systems provide a novel test-bed for studying the interplay between nonlinear dynamics and space charge at high intensity. In this work, the structure of beam Vlasov equilibria is explored for a constant focusing channel based on the nonlinear focusing potential of the Integrable Optics Test Accelerator. Finally, the dynamics of the single-particle orbits is explored in the combined space charge and external focusing fields as a function of beam current, and the self-consistent relaxation of a mismatched beam to equilibrium is characterized.

43 PARTICLE ACCELERATORS↗

Aerosol size determination via light scattering of viruses and protein complexes

Abstract The study of ultrafine particle aerosols, those with particle diameters of 100 nm or less, is important due to their impact on our health and environment. However, given their small sizes, such particles can be difficult to measure and trace. Most common optical methods are unable to reach this size range. Other methods exist but incur other limitations, such as the need for electrically charged particles. Here we show how light scattering can be used to detect and measure the size and location of single viruses and protein complexes forming an aerosol beam, as well as trace their path. We were able to detect individual particles down to 16 nm in diameter. The primary purpose of our instrument is to monitor the delivery of single bioparticles to the focus of an X-ray laser to image those particles, but it has the potential to study any other aerosols such as those resulting from ultrafine sea spray, with important consequences for cloud formation and climate modeling, or from combustion, responsible for most air pollution and resulting health impacts.

Physics↗

Real-Time Data Acquisition and Processing System for MHz Repetition Rate Image Sensors

An electro-optic detector is one of the diagnostic setups used in particle accelerators. It employs an electro-optic crystal to encode the longitudinal beam charge profile in the spectrum of a light pulse. The charge distribution is then reconstructed using data captured by a fast spectrometer. The measurement repetition rate should match or exceed the machine bunching frequency, which is often in the range of several MHz. A high-speed optical line detector (HOLD) is a linear camera designed for easy integration with scientific experiments. The use of modern FPGA circuits helps in the efficient collection and processing of data. The solution is based on Xilinx 7-Series FPGA circuits and implements a custom latency-optimized architecture utilizing the AXI4 family of interfaces. HOLD is one of the fastest line cameras in the world. Thanks to its hardware architecture and a powerful KALYPSO sensor from KIT, it outperforms the fastest comparable commercial devices.

MicroTCA↗

Quantum Spin Probe of Single Charge Dynamics

Electronic defects in semiconductors form the basis for emerging quantum technologies, but many defect centers are difficult to access at the single-particle level. A method for probing optically inactive spin defects would reveal semiconductor physics at the atomic scale and advance the study of new quantum systems. Here, we exploit the intrinsic correlation between the charge and spin states of defect centers to measure the charge populations and dynamics of single substitutional nitrogen spin defects in diamond. By probing their steady-state spin population, read out at the single-defect level with a nearby nitrogen vacancy center, we directly measure the defect ionization-corroborated by first-principles calculations-an effect we do not have access to with traditional coherence-based quantum sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Incoherent Dynamics of Intense Proton Beams under Electron Cooling

The minimum emittance of ion beams achieved using electron cooling is limited by the heating processes of Intra Beam Scattering and diffusion driven by resonance crossing of particles due to space-charge. We describe a new experiment to explore the intense space-charge regime with a transverse tune shift approaching -0.5 using 2.5~MeV protons at the Integrable Optics Test Accelerator (IOTA) at Fermilab. We also report on the results from PyORBIT simulations incorporating transverse space-charge and electron cooling with emphasis on the incoherent dynamics of the particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Incoherent Dynamics of Intense Proton Beams Under Electron Cooling

The minimum emittance of ion beams achieved using electron cooling is limited by the heating processes of Intra Beam Scattering and diffusion driven by resonance crossing of particles due to space-charge. We describe a new experiment to explore the intense space-charge regime with a transverse tune shift approaching -0.5 using 2.5 MeV protons at the Integrable Optics Test Accelerator (IOTA) at Fermilab. We also report on the results from PyORBIT simulations incorporating transverse space-charge and electron cooling with emphasis on the incoherent dynamics of the particles.

43 PARTICLE ACCELERATORS↗

Space-Charge Aberrations in Single-Shot Time-Resolved Transmission Electron Microscopy

In this paper, we discuss effects of space-charge fields on imaging performance in a single-shot time-resolved transmission electron microscope. Using a Green’s function perturbation method, we derive analytical estimates for the effects of space-charge nonlinearity on the image formation process and the associated aberration coefficients. The dependence of these coefficients on the initial beam phase space distribution is elucidated. The results are validated by particle tracking simulations and provide fundamental scaling laws for the trade-off between temporal and spatial resolutions in single-shot time-resolved transmission electron microscopy.

43 PARTICLE ACCELERATORS↗

Assessment of errors in analytic modeling of permanent magnet electron spectrometers for laser-plasma accelerators

Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.

Electromagnetic optics↗