Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ceramic implants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Nitrogen ion implantation into various materials using 28 GHz electron cyclotron resonance ion source

The installation of the 28 GHz electron cyclotron resonance ion source (ECRIS) ion implantation beamline was recently completed at the Korea Basic Science Institute. The apparatus contains a beam monitoring system and a sample holder for the ion implantation process. The new implantation system can function as a multipurpose tool since it can implant a variety of ions, ranging hydrogen to uranium, into different materials with precise control and with implantation areas as large as 1–10 mm{sup 2}. The implantation chamber was designed to measure the beam properties with a diagnostic system as well as to perform ion implantation with an in situ system including a mass spectrometer. This advanced implantation system can be employed in novel applications, including the production of a variety of new materials such as metals, polymers, and ceramics and the irradiation testing and fabrication of structural and functional materials to be used in future nuclear fusion reactors. In this investigation, the first nitrogen ion implantation experiments were conducted using the new system. The 28 GHz ECRIS implanted low-energy, multi-charged nitrogen ions into copper, zinc, and cobalt substrates, and the ion implantation depth profiles were obtained. SRIM 2013 code was used to calculate the profiles under identical conditions, and the experimental and simulation results are presented and compared in this report. The depths and ranges of the ion distributions in the experimental and simulation results agree closely and demonstrate that the new system will enable the treatment of various substrates for advanced materials research.

36 MATERIALS SCIENCE↗

Radiation damage of hollandite in multiphase ceramic waste forms

Radiation damage was simulated in multiphase titanate-based ceramic waste forms using an ion accelerator to generate high energy alpha particles (He + ) and an ion implanter to generate 7 MeV gold (Au 3+ ) particles. X-ray diffraction and transmission electron microscopy were used to characterize the damaged surfaces and nearby regions. Simulated multiphase ceramic waste forms were prepared using two processing methods: spark plasma sintering and melt-processing. Both processing methods produced ceramics with similar phase assemblages consisting of hollandite-, zirconolite/pyrochlore-, and perovskite- type phases. The measured heavy ion (Au 3+ ) penetration depth was less in spark plasma sintered samples than in melt-processed samples. Furthermore, structural breakdown of the hollandite phase occurred under He + irradiation indicated by the presence of x-ray diffraction peaks belonging to TiO 2 , BaTiO 5 , and other hollandite related phases (Ba 2 Ti 9 O 20 ). The composition of the constituent hollandite phase affected the extent of damage induced by Au 3+ ions.

36 MATERIALS SCIENCE↗

Investigation of Bone Growth in Additive-Manufactured Pedicle Screw Implant by Using Ti-6Al-4V and Bioactive Glass Powder Composite

In this study, we optimized the geometry and composition of additive-manufactured pedicle screws. Metal powders of titanium-aluminum-vanadium (Ti-6Al-4V) were mixed with reactive glass-ceramic biomaterials of bioactive glass (BG) powders. To optimize the geometry of pedicle screws, we applied a novel numerical approach to proposing the optimal shape of the healing chamber to promote biological healing. We examined the geometry and composition effects of pedicle screw implants on the interfacial autologous bone attachment and bone graft incorporation through in vivo studies. The addition of an optimal amount of BG to Ti-6Al-4V leads to a lower elastic modulus of the ceramic-metal composite material, effectively reducing the stress-shielding effects. Pedicle screw implants with optimal shape design and made of the composite material of Ti-6Al-4V doped with BG fabricated through additive manufacturing exhibit greater osseointegration and a more rapid bone volume fraction during the fracture healing process 120 days after implantation, per in vivo studies.

stress-shielding effect↗

Direct hydrothermal synthesis of hydroxyapatite/alumina nanocomposite

Hydrothermal synthesis offers numerous advantages such as: control over product homogeneity, nucleation, growth and aging. This leads to the control of particle aggregation, size uniformity and morphology over conventional and non-conventional ceramic synthesis methods. In the present work, a novel procedure for the direct synthesis of Hydroxyapatite (HAp)/alumina nanocomposite in a hydrothermal vessel with continuous stirring was investigated, where the effects of different concentration of aluminium nitrate were also studied. The optimized concentration of starting material for the characteristic formation of HAp/alumina composite (hexagonal HAp and monoclinic alumina phases) was determined by X-ray diffraction (XRD) study. The size distribution of HAp/alumina composite was found as 100 nm by electron microscopy and EDAX revealed that the concentration of alumina in the HA4 was ~ 10%, which is more suitable for biomedical implant. Further, the cytotoxicity study against MG 63 cells showed that HA4 was biocompatible even at higher concentration (200 μg/ml). Hence, the direct synthesis of HAp/alumina composite without the formation of any intermediate like calcium aluminate could be used as a novel approach to prepare HAp based biomedical implants.

36 MATERIALS SCIENCE↗

Ceramics Based on Powder Mixtures Containing Calcium Hydrogen Phosphates and Sodium Salts (Na{sub 2}CO{sub 3}, Na{sub 4}P{sub 2}O{sub 7}, and NaPO{sub 3})

Ceramic materials in the Na{sub 2}O–CaO–P{sub 2}O{sub 5} system have been produced using powder mixtures containing calcium hydrogen phosphates (monetite/brushite: CaHPO{sub 4}/CaHPO{sub 4} ∙ 2H{sub 2}O) and sodium salts (Na{sub 2}CO{sub 3} ∙ H{sub 2}O, Na{sub 4}P{sub 2}O{sub 7} ∙ 10H,O, and NaPO{sub 3}). These salts were used as precursors to the following high-temperature phases: Сa{sub 2}P{sub 2}O{sub 7}, Na{sub 2}O, Na{sub 4}P{sub 2}O{sub 7}, and NaPO{sub 3}. The amount of the salts in the powder mixtures was such that the oxide composition of the ceramics corresponded to 10 mol % sodium oxide for each mixture in the Na{sub 2}O–CaO–P{sub 2}O{sub 5} system. The powder mixtures were prepared using mechanical activation in acetone, which was accompanied by monetite rehydration to brushite. X-ray diffraction characterization showed that, after firing, the phase composition of the ceramics produced from the powder mixtures thus prepared lay in the Сa{sub 2}P{sub 2}O{sub 7}–NaCaPO{sub 4}–Na{sub 2}СaP{sub 2}O{sub 7}–Са(РО{sub 3}){sub 2} phase field. The resultant ceramic materials contain biocompatible and bioresorbable phases and can be recommended for bone implant fabrication.

36 MATERIALS SCIENCE↗

Diopside (CaO-MgO-2SiO2)-fluorapatite (9CaO-3P2O5-CaF2) glass-ceramics: Potential materials for bone tissue engineering

Glass-ceramics in the diopside (CaMgSi2O6) - fluorapatite [Ca5(PO4)3F] system are potential candidates for restorative dental and bone implant materials. In the present study, a series of glasses along diopside - fluorapatite binary system have been prepared with varying diopside/fluorapatite ratios for their potential applications in bone tissue engineering. The glasses were obtained from compositions with fluorapatite contents varying between 0-40 wt.%. The sintering ability and crystallization kinetics of as obtained amorphous glasses have been studied through hot-stage microscopy (HSM) and differential thermal analysis (DTA), respectively while crystalline phase evolution in sintered GCs has been followed by X-ray diffraction (XRD) adjoined with Rietveld-R.I.R. technique and scanning electron microscopy (SEM). Further, biodegradation and apatite forming ability of glass-ceramics were investigated by immersion of glass-ceramic discs in simulated body fluid (SBF) solution while chemical degradation and weight loss of glass-ceramics were studied by immersion in Tris-HCl in accordance with standard ISO 10993-14. The addition of fluorapatite (10-25 wt.%) in diopside glass system significantly enhanced the sintering ability of glass-ceramics and improved their apatite forming ability along with their biodegradation behaviour. Moreover, the in vitro cellular responses to glass-ceramics showed good cell viability and significant stimulation of osteoblastic differentiation, suggesting the possible use of the glass-ceramics for bone regeneration.

58 GEOSCIENCES↗

Bioactive glass-ceramic coatings prepared by pulsed laser deposition from RKKP targets (sol-gel vs melt-processing route)

Highlights: Black-Right-Pointing-Pointer Bioactive glass-ceramic coatings for bone tissue repair and regeneration. Black-Right-Pointing-Pointer Pulsed Lased Deposition allowed congruent transfer of target composition to coating. Black-Right-Pointing-Pointer Target was prepared by sol-gel process suitable for compositional tailoring. Black-Right-Pointing-Pointer Titanium, widely used for orthopaedics and dental implants, was used as substrate. Black-Right-Pointing-Pointer The physico-chemical properties of the prepared coatings are reported. -- Abstract: The deposition of innovative glass-ceramic composition (i.e. RKKP) coatings by Pulsed Lased Deposition (PLD) technique is reported. RKKP was synthesised following two methodologies: melt-processing and sol-gel, the latter being particularly suitable to tailor the compositional range. The PLD advantage with respect to other deposition techniques is the congruent transfer of the target composition to the coating. The physico-chemical properties of films were investigated by Scanning Electron and Atomic Force Microscopies, Fourier Transform Infrared Spectroscopy, Angular and Energy Dispersive X-ray Diffraction, and Vickers microhardness. The deposition performed at 12 J/cm{sup 2} and 500 Degree-Sign C allows to prepare crystalline films with the composition that replicates rather well that of the initial targets. The 0.6 {mu}m thin melt-processing RKKP films, possessing the hardness of 25 GPa, and the 4.3 {mu}m thick sol-gel films with the hardness of 17 GPa were obtained.

36 MATERIALS SCIENCE↗

Surface properties, crystallinity and optical properties of anodised titanium in mixture of β-glycerophosphate (β-GP) and calcium acetate (CA)

Anodic oxidation is an electrochemical method for the production of ceramic films on a metallic substrate. It had been widely used to deposit the ceramic coatings on the metals surface. This method has been widely used in surface modification of biomaterials especially for dental implants. In this study, the surface morphology, crystallinity and optical properties of titanium foil was modified by anodising in mixture of β-glycerophosphate disodium salt pentahydrate (β-GP) and calcium acetate monohydrate (CA). The experiments were carried out at high voltage (350 V), different anodising time (5 and 10 minutes) and current density (10-70 mA.cm{sup −2}) at room temperature. Anodised titanium was characterised by using field emission scanning electron microscopy (FESEM), X-ray diffractometer (XRD), and UV-Vis spectrometry. The result of the experiment showed that surface morphology, crystallinity and optical properties depended strongly on the current density and anodising time. More porous surface and large amount of anatase and rutile was produced at higher current density and longer anodising time. Apart from that, it is also revealed that the energy band gap of anodised titanium increases as the increase in current density due to the presence of anatase and rutile TiO{sub 2}.

36 MATERIALS SCIENCE↗

Biocompatibility of a novel heat-treated and ceramic-coated magnesium alloy (Mg–1.2Zn–0.5Ca–0.5Mn) for resorbable skeletal fixation devices

Our recent exploration into the use of biodegradable metals and surface treatments resulting in sufficient strength for skeletal reconstruction applications has led to the need to test these devices’ cytotoxicity. More specifically, our group has developed a resorbable magnesium alloy, Mg–1.2Zn–0.5Ca–0.5Mn, that can be strengthened by heat treatment and coated with a ceramic layer offering time-certain resorption of a medical device. This in vitro study shows that these treatments do not result in cytotoxicity. Both heat-treated (HT) and HT + ceramic-coated (sol–gel) coupons demonstrated more than 70% viability. Thus, these processing steps are likely to be useful in producing biocompatible, resorbable implants that incorporate our Mg–1.2Zn–0.5Ca–0.5Mn alloy.

36 MATERIALS SCIENCE↗

Strength, toughness, and reliability of a porous glass/biopolymer composite scaffold

Abstract Development of bioactive glass and ceramic scaffolds intended for the reconstruction of large segmental bone defects remains a challenge for materials science due to the complexities involved in clinical implantation, bone–implant reaction, implant degradation and the multiple loading modes the implants subjected to. A comprehensive evaluation of the mechanical properties of inorganic scaffolds and exploration of new ways to toughen brittle constructs are critical prior to their successful application in loaded sites. A simple and widely adopted approach involves the coating of an inorganic scaffold with a polymeric material. In this work, a systematic evaluation of the influence of a biopolymer, polycaprolactone (PCL), coating on the mechanical performance of bioactive glass scaffolds was carried out. Results from this work indicate that a biopolymer PCL coating was more effective in increasing the compressive strength and reliability of the glass scaffold under compression, but less effective in improving its flexural strength or fracture toughness. This is the first report that reveals the limited successfulness of a polymer coating in improving the toughness of strong scaffolds, suggesting that new and novel ways of toughening inorganic scaffolds should be future research directions for scaffolds applied in loaded sites. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1209–1217, 2018.

Fu, Qiang↗

An implantable biomechanical energy harvester for animal monitoring devices

Insufficient service life and the resulting need for battery replacements have been a great challenge for implantable electronic devices. This is particularly true for animal tracking applications, because recapturing animals is often unlikely once they are released to the wild. To tackle this problem, we developed a biomechanical energy harvester that uses a Macro Fiber Composite™ (MFC) piezoelectric beam to harvest the mechanical energy from animals’ body bending movements as the power source for implantable and wearable devices. Prototypes of an underwater acoustic transmitter using this technology were subdermally implanted into juvenile white sturgeon and their energy harvesting performance was evaluated through the device’s transmissions. Additionally, the fish successfully recovered from the implantation surgery and freely swam inside a tank. The transmitter prototypes in the fish continually transmitted signals for a period up to 5 weeks. A benchtop test setup was also created to emulate the fish’s body bending, estimate the device’s energy harvesting performance in the live fish, and perform accelerated fatigue testing of the energy harvester by applying test parameters learned from a video study of the fish’s body movement and behavior characteristics. The gradual depolarization of the piezoelectric ceramic material in the MFC under cyclic mechanical loading was the main limiting factor for the life span of the energy harvester. Pathways for improvement are proposed to achieve long-term efficacy of powering implantable and wearable electronic devices.

42 ENGINEERING↗

Use of Xenon Difluoride to Clean Hazardous By-Products in Ion Implanter Source Housings, Turbo Pumps, and Fore-Lines

This paper describes the use of xenon difluoride to clean deposits in the source housing, source turbo pump, and source turbo pump fore-line of ion implanters. Xenon difluoride has previously been shown to be effective in increasing the lifetime of the ion source{sup 1,2} and this paper presents an extension of the technology to other areas within the tool. Process by-products that are deposited in the source housing, turbo pump, and turbo pump fore-line can not only pose productivity issues, in the case of coatings on insulators, but can also be flammable and toxic in the case of deposits formed within the turbo pump and fore-line. The results presented in this paper detail the initial successful examples of using xenon difluoride to clean these deposits.ATMI has shown that xenon difluoride is capable of cleaning an insulator in an ion implanter. Typically during use an insulator will become increasingly coated with deposits that could lead to productivity problems. By introducing xenon difluoride into the source housing the insulator residues were effectively cleaned in-situ, thereby extending the maintenance interval and resulting in significant consumable savings.Similar deposits that form in the turbo pump and fore-line could not only lead to production problems due to turbo pump failure or fore-line build-up, but pose significant health risks during the ex-situ cleaning process. Through internal testing ATMI has shown that xenon difluoride is able to clean phosphorus and germanium deposits located within a turbo pump. Additionally, testing has demonstrated that the turbo pump fore-line can be cleaned in-situ without the need to remove these components, thereby virtually eliminating the possibility of fires. The cleaning reaction progress and by-products were monitored using FTIR spectrometry and thermocouples.In order to efficiently clean the source housing, turbo pump, and turbo pump fore-line xenon difluoride delivery must be optimized. This paper also details a hardware concept that maximizes xenon difluoride delivery and allows the clean to be done in a way that is viable for production ion implanters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A 3D printed superconducting aluminium microwave cavity

3D printing of plastics, ceramics, and metals has existed for several decades and has revolutionized many areas of manufacturing and science. Printing of metals, in particular, has found a number of applications in fields as diverse as customized medical implants, jet engine bearings, and rapid prototyping in the automotive industry. Although many techniques are used for 3D printing metals, they commonly rely on computer controlled melting or sintering of a metal alloy powder using a laser or electron beam. The mechanical properties of parts produced in such a way have been well studied, but little attention has been paid to their electrical properties. Here we show that a microwave cavity (resonant frequencies 9.9 and 11.2 GHz) 3D printed using an Al-12Si alloy exhibits superconductivity when cooled below the critical temperature of aluminium (1.2 K), with a performance comparable with the common 6061 alloy of aluminium. Superconducting cavities find application in numerous areas of physics, from particle accelerators to cavity quantum electrodynamics experiments. The result is achieved even with a very large concentration of non-superconducting silicon in the alloy of 12.18%, compared with Al-6061, which has between 0.4% and 0.8%. Our results may pave the way for the possibility of 3D printing superconducting cavity configurations that are otherwise impossible to machine.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiation stability test on multiphase glass ceramic and crystalline ceramic waste forms

A radiation stability study was performed on glass ceramic and crystalline ceramic waste forms. These materials are candidate host materials for immobilizing alkali/alkaline earth (Cs/Sr-CS) + lanthanide (LN) + transition metal (TM) fission product waste streams from nuclear fuel reprocessing. In this study, glass ceramics were fabricated using a borosilicate glass as a matrix in which to incorporate CS/LN/TM combined waste streams. The major phases in these multiphase materials are powellite, oxyaptite, pollucite, celsian, and durable residual glass phases. Al2O3 and TiO2 were combined with these waste components to produce multiphase crystalline ceramics containing hollandite-type phases, perovskites, pyrochlores and other minor metal titanate phases. For the radiation stability test, selected glass ceramic and crystalline ceramic samples were exposed to different irradiation environments including low fluxes of high-energy (~1–5 MeV) protons and alpha particles generated by an ion accelerator, high fluxes of low-energy (hundreds of keV) krypton particles generated by an ion implanter, and in-situ electron irradiations in a transmission electron microscope. These irradiation experiments were performed to simulate self-radiation effects in a waste form. Ion irradiation-induced microstructural modifications were examined using X-ray diffraction and transmission electron microscopy. Our preliminary results reveal different radiation tolerance in different crystalline phases under various radiation damage environments. However, their stability may be rate dependent which may limit the waste loading that can be achieved.

Crystalline ceramic↗

Polylactic acid (PLA)-based multifunctional and biodegradable nanocomposites and their applications

Polylactic acid (PLA)-based nanocomposites are emerging as multifunctional, biodegradable materials, offering sustainable alternatives to petroleum-based plastics. This review examines recent advancements in PLA nanocomposites, focusing on enhanced mechanical strength, thermal stability, and biodegradability achieved through nanofillers like metallic particles, carbon-based materials, and ceramics. Techniques such as in situ polymerization, melt mixing, and electrospinning enable application-specific improvements. PLA's limitations, including brittleness and low barrier properties, are addressed to support diverse applications: in packaging (e.g., extended shelf life), biomedicine (e.g., degradable implants), and electronics (e.g., flexible devices). Despite challenges with filler dispersion and thermal resistance, continued innovations expand PLA's potential across multiple industries, contributing to a sustainable, circular economy.

Biodegradable polymers↗

Bubble Formation and Lattice Parameter Changes Resulting from He Irradiation of Defect-Fluorite Gd2Zr2O7

Pyrochlores have long been considered as potential candidates for advanced ceramic waste-forms for the immobilization of radioactive waste nuclides. This work provides evidence that Gd2Zr2O7, often considered the most radiation tolerant pyrochlore, could be susceptible to radiation damage in the form of bubble nucleation at the highest He doses expected over geological time. Ion irradiations were utilized to experimentally simulate the radiation damage and He accumulation produced by ..alpha..-decay. Samples were pre-damaged using 7 MeV Au3+ to induce the pyrochlore to defect-fluorite phase transformation, which would occur due to ..alpha..-recoil damage within several hundred years of storage in a Gd2Zr2O7 waste-form. These samples were then implanted to various He concentrations in order to study the long-term effects of He accumulation. Helium bubbles 1-3 nm in diameter were observed in TEM at a concentration of 4.6 at.% He. Some bubbles remained isolated, while others formed chains 10-30 nm in length parallel to the surface. GIXRD measurements showed lattice swelling after irradiating pristine Gd2Zr2O7 with 7 MeV Au3+ to a fluence of 2.2 x 1015 Au/cm2. An increase in lattice swelling was also measured after 2.2 x 1015 Au/cm2 + 2 x 1015 He/cm2 and 2.2 x 1015 Au/cm2 + 2 x 1016 He/cm2. A decrease in lattice swelling was measured after irradiation with 2.2 x 1015 Au/cm2 + 2 x 1017 He/cm2, the fluence where bubbles and bubble chains were observed in TEM. Bubble chains are thought to form in order to reduce lattice strain normal to the surface, which is produced by the Au and He irradiation damage.

36 MATERIALS SCIENCE↗

Charge transportation and permittivity in electron beam irradiated polymethyl methacrylate

The charging phenomenon in the insulating dielectrics often occurs in the radiative environments such as in the outer space and in the nuclear reactor. Both surface charging and bulk charging have various influences on the dielectric properties. Understanding electrical properties of e-beam irradiated dielectrics is of great significance in order to maintain the stability and reliability of the related operating system. In this work, the effect of electron beam irradiation on the permittivity of polymethyl methacrylate (PMMA) samples was investigated. It was found that the variance of permittivity in e-beam irradiated PMMA is mainly determined by two factors. One is the porosity of the material. The irradiating process could increase the porosity of PMMA due to the escape of the small molecule (e.g., CO, CO{sub 2}, and CH{sub 4}) produced during material degradation caused by e-beam irradiation. The enhanced higher porosity corresponds to lower permittivity. The distribution of the implanted charge is the other factor that influences the permittivity. When the distribution of electric field generated by the accumulating charge is asymmetric for the middle thickness of the sample, the PMMA sample with polar groups would be subjected to extra polarization by the field, which could lead to the increase in permittivity. Combining with the model of Wakino et al. [J. Am. Ceram. Soc. 76, 2588 (1993)] on permittivity of mixture materials, the Clausius-Mosotti equation was utilized to analyze the variation in permittivity in the e-beam irradiated PMMA samples.

36 MATERIALS SCIENCE↗