Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “central return”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Specialized physiological studies in support of manned space flight

Breath-by-breath measurements of pulmonary capillary O2 transfer and ventilation with a box-balloon spirometer and mass spectrometer were made on 3 subjects before, during and after 10 min of lower body negative pressure (LBNP) at -20, -40 and -60 Torr with arterial samples at -60 Torr. Deficits in blood O2 stores (O2B) were noted during LBNP with repayment of O2B during recovery being related to the intensity of LBNP stress. Concurrent calf volume, measured with a Hg strain gauge, decreased towards baseline well before the peak rise in pulmonary capillary O2 transfer after the release of LBNP which signified that O2B changes were related to blood volume shifts. The return of O2-depleted pooled blood to the central circulation during the first min. of recovery caused significant stress-related hyperpnea which peaked near 30 sec. and returned to near baseline after the first min. Three-compartment lung model analyses indicated an increase in the ventilated unperfused lung fraction from 0.09 to 0.17 with the effective compartment decreasing from 0.83 to 0.77. It appears that the 30% increase in ventilation equivalent was primarily the result of less effective lung perfusion during the LBNP.

Source record↗

Venous return curves obtained from graded series of valsalva maneuvers

The effects were studied of a graded series of valsalva-like maneuvers on the venous return, which was measured transcutaneously in the jugular vein of an anesthetized dog, with the animal serving as its own control. At each of five different levels of central venous pressure, the airway pressure which just stopped venous return during each series of maneuvers was determined. It was found that this end-point airway pressure is not a good estimator of the animal's resting central venous pressure prior to the simulated valsalva maneuver. It was further found that the measured change in right atrial pressure during a valsalva maneuver is less than the change in airway pressure during the same maneuver, instead of being equal, as had been expected. Relative venous return curves were constructed from the data obtained during the graded series of valsalva maneuvers.

Mastenbrook, S. M., Jr.↗

Multiple scattering lidar returns from stratus clouds

Multiple scattering lidar returns from stratus clouds were measured using a multi-field-of-view (MFOV) lidar operating at 1.054 microns. The detector consists of four concentric silicon photodiodes which define half-angle fields of view (FOV) of 3.8, 12.5, 25 and 38.5 mrad. The central FOV receives the conventional lidar signal, while the outer FOV's receive only multiply scattered contributions. The ratios of the signals in the outer FOV's to the signal in the central FOV is an indication of the lateral spreading of the scattered component of the laser pulse as it propagates through the cloud. MFOV lidar returns from stratus clouds measured between October 1991 and March 1992 can be divided into two distinct types, those with large multiple scattering ratios and those with small ratios. An example of each type of return is shown. Both measurements were made at an elevation angle of 45 degrees. Clouds with small multiple scattering signals probably have a high concentration of much larger particles on the order of hundreds of micrometers in size. This is a typical size range for suspended ice crystals or precipitations. Stratus clouds often have a high concentration of ice crystals even when there is no precipitation. Large ice crystals would give smaller signals in the outer FOV's because much of the scattered intensity is contained in a narrow diffraction peak with an angular width on the order of milliradians. The result is that for a given extinction, many more orders of scattering are required for the laser pulse to spread out. So far we have not been able to do simulations of MFOV lidar returns from ice crystal clouds because of uncertainties about the phase function of the crystals, particularly the magnitude of the backscatter peak at 180 degrees. On two occasions, MFOV lidar returns measured just prior to snowfall, showed a striking vertical profile. An example is shown. From 900 to 1300m, the multiply scattered signals are negligible compared to the return in the central FOV. Abruptly, at 1300m strong signals begin in the outer FOVs. These results could be explained by the presence of a cloud layer composed of water droplets at a range of 1300m (or 900m above ground) with snow precipitations forming at the bottom of the cloud. By measuring the polarization ratio of lidar signals, Pal and Carswell have observed snow precipitating from a cloud layer composed of water droplets. Based on these results, we believe that analysis of multiple scattering lidar returns can yield important information on the phase of cloud particles.

Hutt, D. L.↗

Hot-spot tectonics of Eistla Regio, Venus: Results from Magellan images and Pioneer Venus gravity

Eistla Regio (ER) is a broad, low, discontinuous topographic rise striking roughly EW at low northern latitudes of Venus. Some 2000 x 7000 km in dimensions, it is the third largest rise in planform on Venus after Aphrodite Terra and Beta Phoebe Regiones. These rises are the key physiographic elements in a hot spot model of global tectonics including transient plume behavior. Since ER is the first such rise viewed by Magellan and the latitude is very favorable for Pioneer Venus gravity studies, some of the predictions of a time dependent hot spot model are tested. Western ER is defined as the rise including Gula and Sif Mons and central ER as that including Sappho Patera. Superior conjunction prevented Magellan from returning data on eastern ER (Pavlova) during the first mapping cycle. It is concluded that the western and central portions of ER, while part of the same broad topographic rise and tectonic framework, have distinctly different surface ages and gravity signatures. The western rise, including Gula and Sif Mons, is the expression of deep seated uplift with volcanism limited to the individual large shields. The eastern portion has been widely resurfaced more recently by thermal anomalies in the mantle.

Grimm, Robert E.↗

Detailed Test Objectives (DTOs) and Detailed Supplementary Objectives (DSOs)

The purpose of this experiment is to demonstrate the performance and operations of the GPS during orbiter ascent, entry and landing phases utilizing a modified military GPS receiver processor and the existing orbiter GPS antennas. The purpose of this experiment is to demonstrate the capability to perform a manually controlled landing in the presence of a crosswind. Changes in gastrointestinal function and physiology as a result of spaceflight affect drug absorption and the bioavailability of oral medications, which can compromise therapeutic effectiveness. This DSO will lead to the design and development of effective pharmocological countermeasures and therapeutic adjustments for spaceflight. A previous observation suggested that discordant sensory stimuli caused by an unusual motion environment disrupted spatial orientation and balance control in a returning crewmember by triggering a state change in central vestibular processing. The findings of the current investigation are expected to demonstrate the degree to which challenging motion environments may affect post-flight (re)adaptation to gravity.

Source record↗

Cardiovascular consequences of bed rest: effect on maximal oxygen uptake

Maximal oxygen uptake (VO2max) is reduced in healthy individuals confined to bed rest, suggesting it is independent of any disease state. The magnitude of reduction in VO2max is dependent on duration of bed rest and the initial level of aerobic fitness (VO2max), but it appears to be independent of age or gender. Bed rest induces an elevated maximal heart rate which, in turn, is associated with decreased cardiac vagal tone, increased sympathetic catecholamine secretion, and greater cardiac beta-receptor sensitivity. Despite the elevation in heart rate, VO2max is reduced primarily from decreased maximal stroke volume and cardiac output. An elevated ejection fraction during exercise following bed rest suggests that the lower stroke volume is not caused by ventricular dysfunction but is primarily the result of decreased venous return associated with lower circulating blood volume, reduced central venous pressure, and higher venous compliance in the lower extremities. VO2max, stroke volume, and cardiac output are further compromised by exercise in the upright posture. The contribution of hypovolemia to reduced cardiac output during exercise following bed rest is supported by the close relationship between the relative magnitude (% delta) and time course of change in blood volume and VO2max during bed rest, and also by the fact that retention of plasma volume is associated with maintenance of VO2max after bed rest. Arteriovenous oxygen difference during maximal exercise is not altered by bed rest, suggesting that peripheral mechanisms may not contribute significantly to the decreased VO2max. However reduction in baseline and maximal muscle blood flow, red blood cell volume, and capillarization in working muscles represent peripheral mechanisms that may contribute to limited oxygen delivery and, subsequently, lowered VO2max. Thus, alterations in cardiac and vascular functions induced by prolonged confinement to bed rest contribute to diminution of maximal oxygen uptake and reserve capacity to perform physical work.

Non-NASA Center↗

Neurovestibular and Sensorimotor Studies in Space and Earth Benefits

This review summarizes what has been learned from studies of human neurovestibular system in weightless conditions, including balance and locomotion, gaze control, vestibular-autonomic function and spatial orientation, and gives some examples of the potential Earth benefits of this research. Results show that when astronauts and cosmonauts return from space flight, both the peripheral and central neural processes are physiologically and functionally altered. There are clear distinctions between the virtually immediate adaptive compensations to weightlessness and those that require longer periods of time to adapt. However, little is known to date about the adaptation of sensory-motor functions to long-duration space missions in weightlessness and to the transitions between various reduced gravitational levels, such as on the Moon and Mars. Results from neurovestibular research in space have substantially enhanced our understanding of the mechanisms and characteristics of postural, gaze, and spatial orientation deficits, analogous to clinical cases of labyrinthine-defective function. Also, space neurosciences research has participated in the development and application of significant new technologies, such as video recording and processing of three-dimensional eye movements and posture, hardware for the unencumbered measurement of head and body movement, and procedures for investigating otolith function on Earth. In particular, devices such as centrifugation or off-vertical axis rotation could enhance clinical neurological testing because it provides linear acceleration which specifically stimulates the otolith organs in a frequency range close to natural head and body movement.

Clement, Gilles↗

Simpler cabling and power link for remote readouts

Display power and segment data are multiplexed over same coaxial line. Thus, only one wire and return lead are needed, and single power supply at central location can service all remote displays.

Perry, J. C.↗

Comparison of Echo 7 field line length measurements to magnetospheric model predictions

The Echo 7 sounding rocket experiment injected electron beams on central tail field lines near L = 6.5. Numerous injections returned to the payload as 'conjugate echoes' after mirroring in the southern hemisphere. Field line lengths calculated from measured conjugate echo bounce times and energies are compared to predictions made by integrating electron trajectories through various magnetospheric models. Although Kp at launch was 3-, quiet time magnetic models best fit the echo measurements. Geosynchronous satellite magnetometer measurements near the Echo 7 field lines during the flight were best modeled by the Olson-Pfitzer Dynamic Model and the Tsyganenko-Usmanov model for Kp = 3. The discrepancy between the models that best fit the Echo 7 data and those that fit the satellite data was most likely due to uncertainties in the small-scale configuration of the magnetospheric models. The field line length measured by the conjugate echoes showed some temporal variation in the magnetic field, also indicated by the satellite magnetometers. This demonstrates the utility an Echo-style experiment could have in substorm studies.

Nemzek, R. J.↗

Central Valley Water Resources II: Groundwater Sustainability Management Support in the California Central Valley using GRACE and InSAR Datasets

California’s Central Valley is one of the most productive agricultural regions in the United States, producing a fourth of the nation’s food supply. The water demand in this region is heavily dependent on groundwater resources, resulting in over pumping of aquifers at unsustainable rates during recent periods of severe drought. Over the past century, Central Valley aquifers have experienced a significant decline in groundwater levels, resulting in land subsidence and irreversible loss in groundwater storage. In 2014, the state enacted the Sustainable Groundwater Management Act, requiring high and medium priority subbasins to suspend overdraft and achieve sustainable levels of pumping and recharge by 2042.The California Department of Water Resources (DWR) oversees subbasin groundwater management; however, monitoring remains challenging due to sparse and inconsistent in situ data. To assist the DWR, this project developed a user-friendly executable application and an interactive visualization tool to quantify groundwater storage and land subsidence trends using remotely sensed and in situ data. The team utilized NASA’s Gravity Recovery and Climate Experiment (GRACE), GRACE Follow-On (GRACE-FO), Sentinel-1 C-band Synthetic Aperture Radar (C-SAR) interferograms, and Advanced Land Observing Satellite 2 (ALOS-2) Phased Array L-band Synthetic Aperture Radar 2 (PALSAR-2) interferograms in conjunction with well and GPS measurements to analyze groundwater and subsidence trends. GRACE and well data returns produced a strong Pearson correlation of .84, while Sentinel-1 and GPS data returns produced a Pearson correlation of .41 over the entire Central Valley. These findings suggest remotely sensed GRACE and interferometric SAR data can be used in the absence of in situ data.

DEVELOP Project Summary↗

Impact of Water Withdrawals from Groundwater and Surface Water on Continental Water Storage Variations

Humans have strongly impacted the global water cycle, not only water flows but also water storage. We have performed a first global-scale analysis of the impact of water withdrawals on water storage variations, using the global water resources and use model WaterGAP. This required estimation of fractions of total water withdrawals from groundwater, considering five water use sectors. According to our assessment, the source of 35% of the water withdrawn worldwide (4300 cubic km/yr during 1998-2002) is groundwater. Groundwater contributes 42%, 36% and 27% of water used for irrigation, households and manufacturing, respectively, while we assume that only surface water is used for livestock and for cooling of thermal power plants. Consumptive water use was 1400 cubic km/yr during 1998-2002. It is the sum of the net abstraction of 250 cubic km/yr of groundwater (taking into account evapotranspiration and return flows of withdrawn surface water and groundwater) and the net abstraction of 1150 km3/yr of surface water. Computed net abstractions indicate, for the first time at the global scale, where and when human water withdrawals decrease or increase groundwater or surface water storage. In regions with extensive surface water irrigation, such as Southern China, net abstractions from groundwater are negative, i.e. groundwater is recharged by irrigation. The opposite is true for areas dominated by groundwater irrigation, such as in the High Plains aquifer of the central USA, where net abstraction of surface water is negative because return flow of withdrawn groundwater recharges the surface water compartments. In intensively irrigated areas, the amplitude of seasonal total water storage variations is generally increased due to human water use; however, in some areas, it is decreased. For the High Plains aquifer and the whole Mississippi basin, modeled groundwater and total water storage variations were compared with estimates of groundwater storage variations based on groundwater table observations, and with estimates of total water storage variations from the GRACE satellites mission. Due to the difficulty in estimating area-averaged seasonal groundwater storage variations from point observations of groundwater levels, it is uncertain whether WaterGAP underestimates actual variations or not. We conclude that WaterGAP possibly overestimates water withdrawals in the High Plains aquifer where impact of human water use on water storage is readily discernible based on WaterGAP calculations and groundwater observations. No final conclusion can be drawn regarding the possibility of monitoring water withdrawals in the High Plains aquifer using GRACE. For the less intensively irrigated Mississippi basin, observed and modeled seasonal groundwater storage reveals a discernible impact of water withdrawals in the basin, but this is not the case for total water storage such that water withdrawals at the scale of the whole Mississippi basin cannot be monitored by GRACE.

Doell, Petra↗

On-Shore Central Hydraulic Power Generation for Wind and Tidal Energy

Tidal energy, offshore wind energy, and onshore wind energy can be converted to electricity at a central ground location by means of converting their respective energies into high-pressure hydraulic flows that are transmitted to a system of generators by high-pressure pipelines. The high-pressure flows are then efficiently converted to electricity by a central power plant, and the low-pressure outlet flow is returned. The Department of Energy (DOE) is presently supporting a project led by Sunlight Photonics to demonstrate a 15 kW tidal hydraulic power generation system in the laboratory and possibly later submerged in the ocean. All gears and submerged electronics are completely eliminated. A second portion of this DOE project involves sizing and costing a 15 MW tidal energy system for a commercial tidal energy plant. For this task, Atlantis Resources Corporation s 18-m diameter demonstrated tidal blades are rated to operate in a nominal 2.6 m/sec tidal flow to produce approximately one MW per set of tidal blades. Fifteen units would be submerged in a deep tidal area, such as in Maine s Western Passage. All would be connected to a high-pressure (20 MPa, 2900 psi) line that is 35 cm ID. The high-pressure HEPG fluid flow is transported 500-m to on-shore hydraulic generators. HEPG is an environmentally-friendly, biodegradable, watermiscible fluid. Hydraulic adaptations to ORPC s cross-flow turbines are also discussed. For 15 MW of wind energy that is onshore or offshore, a gearless, high efficiency, radial piston pump can replace each set of top-mounted gear-generators. The fluid is then pumped to a central, easily serviceable generator location. Total hydraulic/electrical efficiency is 0.81 at full rated wind or tidal velocities and increases to 0.86 at 1/3 rated velocities.

wind energy↗

On-Shore Central Hydraulic Power Generation for Wind and Tidal Energy

Tidal energy, offshore wind energy, and onshore wind energy can be converted to electricity at a central ground location by means of converting their respective energies into high-pressure hydraulic flows that are transmitted to a system of generators by high-pressure pipelines. The high-pressure flows are then efficiently converted to electricity by a central power plant, and the low-pressure outlet flow is returned. The Department of Energy (DOE) is presently supporting a project led by Sunlight Photonics to demonstrate a 15 kilowatt tidal hydraulic power generation system in the laboratory and possibly later submerged in the ocean. All gears and submerged electronics are completely eliminated.A second portion of this DOE project involves sizing and costing a 15 megawatt tidal energy system for a commercial tidal energy plant. For this task, Atlantis Resources Corporation's 18-m diameter demonstrated tidal blades are rated to operate in a nominal 2.6 m/sec tidal flow to produce approximately one megawatt per set of tidal blades. Fifteen units would be submerged in a deep tidal area, such as in Maine's Western Passage. All would be connected to a high-pressure (20 megapascals, 2900 pounds per square inch) line that is 35 cm ID. The high-pressure HEPG fluid flow is transported 500-m to on-shore hydraulic generators. HEPG is an environmentally-friendly, biodegradable, water-miscible fluid. Hydraulic adaptations to ORPC's cross-flow turbines are also discussed.For 15 megawatt of wind energy that is onshore or offshore, a gearless, high efficiency, radial piston pump can replace each set of top-mounted gear-generators. The fluid is then pumped to a central, easily serviceable generator location. Total hydraulic/electrical efficiency is 0.81 at full rated wind or tidal velocities and increases to 0.86 at 1/3 rated velocities.

wind energy↗

Dispersed ion structures at the poleward edge of the auroral oval: Low-altitude observations and numerical modeling

We have compared the AUREOL 3 (A3) observations of auroral ion precipitation, particularly ion beams, with the results from the global kinetic model of magnetotail plasma of Ashour-Abdalla et al. (1993). We have identified 101 energetic keV H(+) velocity dispersed precipitating ion structures (VDIS) with fluxes above 10(exp -3) ergs./sq cm./s in the A3 record between the end of 1981 and mid-1984. These beams display a systematic increase in energy with increasing latitude and were observed in a narrow region within less than 1 deg in latitude of the polar cap boundary. The VDIS are the most distinctive feature in the auroral zone of the plasma sheet boundary layer. We report first on a statistical analysis of the possible ralationships between magnetic activity or substorm phase and the VDIS properties. Our particle simulations of the precipitating ions have been extended by using a series of modified versions of the Tsyganenko (1989) magnetic field model and by varying the cross-magnetosphere electric field. In the simulations, plasma from a mantle source is subject to strong nonlinear acceleration, forming beams which flow along the PSBL. Only 3 to 4% of these beams precipitate into the ionosphere to form the VDIS while the majority return to the equatorial plane after mirroring and form the thermalized central plasma sheet. The final energy and the dispersion of the beams in the model depend on the amplitude of the cross-tail electric field. Two unsual observations of low-energy (less than 5 keV) O(+) VDIS, shifted by 4 deg 5 deg in invariant latitude equatorward of H(+) VDIS are analyzed in detail. The sparsity of such O(+) events and the absence of the changes in the flux and frequency of occurrence indicate a solar wind origin for the plasma. Finally, large-scale kinetic modeling, even with its simplifications and assumptions (e.g., static magnetic field, solar wind source), reproduces low-altitude auroral ion features fairly well; it may therefore be presented as an appropriate framework into which data on energization and transport of the hot plasma, obtained in the equatorial plane, could be inserted in the near future.

Bosqued, J. M.↗

Method and apparatus for spatially variable rate application of agricultural chemicals based on remotely sensed vegetation data

Remotely sensed spectral image data are used to develop a Vegetation Index file which represents spatial variations of actual crop vigor throughout a field that is under cultivation. The latter information is processed to place it in a format that can be used by farm personnel to correlate and calibrate it with actually observed crop conditions existing at control points within the field. Based on the results, farm personnel formulate a prescription request, which is forwarded via email or FTP to a central processing site, where the prescription is prepared. The latter is returned via email or FTP to on-side farm personnel, who can load it into a controller on a spray rig that directly applies inputs to the field at a spatially variable rate.

Hood, Kenneth Brown↗

Method and system for spatially variable rate application of agricultural chemicals based on remotely sensed vegetation data

Remotely sensed spectral image data are used to develop a Vegetation Index file which represents spatial variations of actual crop vigor throughout a field that is under cultivation. The latter information is processed to place it in a format that can be used by farm personnel to correlate and calibrate it with actually observed crop conditions existing at control points within the field. Based on the results, farm personnel formulate a prescription request, which is forwarded via email or FTP to a central processing site, where the prescription is prepared. The latter is returned via email or FTP to on-side farm personnel, who can load it into a controller on a spray rig that directly applies inputs to the field at a spatially variable rate.

Hood, Kenneth Brown↗

Dynamic Visual Acuity and Landing Sickness in Crewmembers Returning from Long-Duration Spaceflight

Long-term exposure to microgravity causes sensorimotor adaptations that result in functional deficits upon returning to a gravitational environment. At landing the vestibular system and the central nervous system, responsible for coordinating head and eye movements, are adapted to microgravity and must re-adapt to the gravitational environment. This re-adaptation causes decrements in gaze control and dynamic visual acuity, with astronauts reporting oscillopsia and blurred vision. Dynamic visual acuity (DVA) is assessed using an oscillating chair developed in the Neuroscience Laboratory at JSC. This chair is lightweight and easily portable for quick deployment in the field. The base of the chair is spring-loaded and allows for manual oscillation of the subject. Using a metronome, the chair is vertically oscillated plus or minus 2 cm at 2 Hz by an operator, to simulate walking. While the subject is being oscillated, they are asked to discern the direction of Landolt-C optotypes of varying sizes and record their direction using a gamepad. The visual acuity thresholds are determined using an algorithm that alters the size of the optotype based on the previous response of the subject using a forced-choice best parameter estimation that is able to rapidly converge on the threshold value. Visual acuity thresholds were determined both for static (seated) and dynamic (oscillating) conditions. Dynamic visual acuity is defined as the difference between the dynamic and static conditions. Dynamic visual acuity measures will be taken prior to flight (typically L-180, L-90, and L-60) and up to eight times after landing, including up to 3 times on R plus 0. Follow up measurements will be taken at R plus 1 (approximately 36 hours after landing). Long-duration International Space Station crewmembers will be tested once at the refueling stop in Europe and once again upon return to Johnson Space Center. In addition to DVA, subjective ratings of motion sickness will be recorded throughout the testing. Using the chair as a portable and reliable way to test DVA, we aim to test returning astronauts to assess the amount of retinal slip that they experience. By comparing these measurements to their motion sickness scores (using a scale of 1 to 20 where 20 is vomiting), we will correlate the amount of retinal slip to the level of motion sickness experienced. In addition to testing this in returning astronauts, we will perform ground-based studies to determine the effectiveness of stroboscopic goggles in reducing retinal slip and improving DVA. Finally, we will employ stroboscopic goggles in the field to astronauts experiencing high levels of motion sickness to minimize retinal slip and reduce their symptoms.

Rosenberg, M.J.F↗

Stroboscopic Goggles as a Countermeasure for Dynamic Visual Acuity and Landing Sickness in Crewmembers Returning from Long-Duration Spaceflight

Long-term exposure to microgravity causes sensorimotor adaptations that result in functional deficits upon returning to a gravitational environment. At landing, the vestibular system and the central nervous system, responsible for coordinating head and eye movements via the vestibulo-occular reflex (VOR), are adapted to microgravity and must re-adapt to the Earth's gravitational environment. This re-adaptation causes decrements in gaze control and dynamic visual acuity, with astronauts reporting oscillopsia and blurred vision. These effects are caused by retinal slip, or the inability to keep an image focused on their retina, which is thought to drive motion sickness symptoms experienced upon landing. Retinal slip can be estimated by dynamic visual acuity (DVA); visual acuity while in motion. Peters et al. (2011) find that DVA is worsened in astronauts by an average of 0.75 eye-chart lines one day after landing. Previously, the use of stroboscopic goggles has shown to be effective in minimizing motion sickness symptoms due to retinal slip (Reschke et al. 2007). In this study, we simulated the decrement in DVA caused by sensorimotor re-adaptation by using minifying lenses and then testing the efficacy of stroboscopic goggles in preventing retinal slip and improving DVA. Dynamic visual acuity is assessed using an oscillating chair developed in the Neuroscience Laboratory at JSC. This chair is motor-driven and oscillates vertically at 2 Hz with a vertical displacement of +/- 2 cm to simulate the vertical translations that occur while walking. As the subject is being oscillated, they are asked to discern the direction of Landolt-C optotypes of varying sizes and record their direction using a gamepad. The visual acuity thresholds are determined using an algorithm that alters the size of the optotype based on the previous responses of the subject using a forced-choice best parameter estimation that is able to rapidly converge on the threshold value. Visual acuity thresholds were determined both for static (seated) and dynamic (oscillating) conditions. Dynamic visual acuity is defined as the difference between the dynamic and static conditions. We found that healthy subjects (n=20) have a significantly impaired DVA while wearing the minifying lenses, demonstrating that the VOR is in an adaptive state and retinal slip is occurring. When subjects' acuity was tested wearing the stroboscopic goggles with the minifying lenses, there was no significant difference in their DVA compared to their baseline DVA. This suggests that stroboscopic goggles are preventing retinal slip and would function as an efficient countermeasure for VOR adaptations and thus help mitigate landing sickness symptoms experienced by long-duration crewmembers. These goggles might also be used to counter blurred vision (caused by retinal slip) experienced by crewmembers during launch where the vehicle vibrations are greatest. The stroboscopic effect could be built into a section of their head mounted displays on the visor of their helmets to be used in these high vibration situation if a mission critical task is necessary.

Rosenberg, M. J. F.↗