Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity ring-down spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

34 records · Page 2

CAPE-K_ISO: Water vapor isotopic measurements from Western Tasmania

This dataset provides processed 1-minute water vapor isotope observations from the Water Vapor Isotopic Measurements During CAPE-K project at the Kennaook/Cape Grim Baseline Air Pollution Station in northwestern Tasmania. Measurements were made with a Picarro L-2130 cavity ring-down spectroscopy analyzer during the CAPE-K deployment. The dataset includes water vapor mixing ratio, d18O, dD, deuterium excess, and propagated 1-sigma uncertainties. Isotope ratios are calibrated to the VSMOW/SLAP scale. Calibration intervals, transition periods, and obvious isotope outliers have been removed. The processed record spans 11 June 2024 to 15 October 2025 and is intended for studies of Southern Ocean marine boundary-layer moisture, isotope variability, air-sea exchange, and cloud and precipitation processes.

Water Vapor Isotopic Composition↗

Atmospheric Oxygen Photoabsorption

The work conducted on this grant was devoted to various aspects of the photophysics and photochemistry of the oxygen molecule. Predissociation linewidths were measured for several vibrational levels in the O2(B3 Sigma(sub u)(sup -)) state, providing good agreement with other groups working on this important problem. Extensive measurements were made on the loss kinetics of vibrationally excited oxygen, where levels between v = 5 and v = 22 were investigated. Cavity ring-down spectroscopy was used to measure oscillator strengths in the oxygen Herzberg bands. The great sensitivity of this technique made it possible to extend the known absorption bands to the dissociation limit as well as providing many new absorption lines that seem to be associated with new O2 transitions. The literature concerning the Herzberg band strengths was evaluated in light of our new measurements, and we made recommendations for the appropriate Herzberg continuum cross sections to be used in stratospheric chemistry. The transition probabilities for all three Herzberg band systems were re-evaluated, and we are recommending a new set of values.

Slanger, Tom G.↗

Hybrid-PIC Modeling of the Transport of Atomic Boron in a Hall Thruster

Computational analysis of the transport of boron eroded from the walls of a Hall thruster is performed by implementing sputter yields of hexagonal boron nitride and velocity distribution functions of boron within the hybrid-PIC model HPHall. The model is applied to simulate NASA's HiVHAc Hall thruster at a discharge voltage of 500V and discharge powers of 1-3 kW. The number densities of ground- and 4P-state boron are computed. The density of ground-state boron is shown to be a factor of about 30 less than the plasma density. The density of the excited state is shown to be about three orders of magnitude less than that of the ground state, indicating that electron impact excitation does not significantly affect the density of ground-state boron in the discharge channel or near-field plume of a Hall thruster. Comparing the rates of excitation and ionization suggests that ionization has a greater influence on the density of ground-state boron, but is still negligible. The ground-state boron density is then integrated and compared to cavity ring-down spectroscopy (CRDS) measurements for each operating point. The simulation results show good agreement with the measurements for all operating points and provide evidence in support of CRDS as a tool for measuring Hall thruster erosion in situ.

Materials Engineering↗

Observation of absorbing aerosols above clouds over the South-East Atlantic Ocean from the geostationary satellite SEVIRI - Part 2: Comparison with MODIS and aircraft measurements from the CLARIFY-2017 field campaign

To evaluate the SEVIRI retrieval for aerosols above clouds presented in Part 1 of the companion paper, the algorithm is applied over the south-east Atlantic Ocean during the CLARIFY-2017 field campaign period. The first step of our analysis compares the retrieved aerosol and cloud properties against equivalent products from the MODIS MOD06ACAERO retrieval (Meyer et al., 2015). While the correlation between the two satellite retrievals of the above-cloud aerosol optical thickness (AOT) is good (R = 0.78), the AOT retrieved by SEVIRI is 20.3 % smaller than that obtained from the MODIS retrieval. This difference in AOT is attributed mainly to the more absorbing aerosol model assumed for the SEVIRI retrieval compared to MODIS. The underlying cloud optical thickness (COT) derived from the two satellites is in good agreement (R = 0.90). The cloud droplet effective radius (CER) retrieved by SEVIRI is consistently smaller than MODIS by 2.2 µm, which is mainly caused by the use of different spectral bands of the satellite instruments. In the second part of our analysis, we compare the forecast water vapour profiles used for the SEVIRI atmospheric correction as well as the aforementioned aerosol and cloud products with in situ measurements made from the Facility for Airborne Atmospheric Measurements (FAAM) aircraft platform during the CLARIFY-2017 campaign. Around Ascension Island, the column water vapour used to correct the SEVIRI signal is overestimated by 3.1 mm in the forecast compared to that measured by dropsondes. However, the evidence suggests that the accuracy of the atmospheric correction improves closer to the African coast. Consistency is observed between the SEVIRI above-cloud AOT and in situ measurements (from cavity ring-down spectroscopy instruments) when the measured single-scattering albedo is close to that assumed in the retrieval algorithm. On the other hand, the satellite retrieval overestimates the AOT when the assumed aerosol model is not absorbing enough. Consistency is also found between the cloud properties retrieved by SEVIRI and the CER measured by a cloud droplet probe and the liquid water path derived from a microwave radiometer. Despite the instrumental limitations of the geostationary satellite, the consistency obtained between SEVIRI, MODIS and the aircraft measurements demonstrates the ability of the retrieval in providing additional information on the temporal evolution of the aerosol properties above clouds.

absorbing aerosols↗

Long-Term 13 C Uptake by 12 C-Enriched Calcite

Knowledge of the exchange of carbon isotopes between dissolved inorganic carbon and calcite minerals is of long-standing importance for the interpretation of sedimentary paleoclimate records and 14 C transport in the geosphere. To assess the mechanism and rates of carbon isotope exchange, we equilibrated 12 C-pure synthetic calcite particles in water, first in a glovebox and then in contact with atmospheric P CO 2 and 13 C/ 12 C ratio, at two different temperatures. Cavity ring-down infrared spectroscopy δ 13 C measurements of the solid revealed sustained 13C incorporation for over a period of 500 days (21 °C) and 125 days (50 °C). We developed a quantitative model for recrystallization and isotope exchange, assuming that the interfacial free energy provides a thermodynamic driving force for the growth of larger particles at the expense of smaller ones. Furthermore, this Ostwald ripening model did not reproduce the kinetics of 13C uptake and required greater coarsening than observed. Rather, the data were best explained by a mechanism involving surface exchange and solid-phase diffusion of 13C into the particles with an inferred effective diffusion constant at 21 °C of about 10 –25 m 2 /s. Although this work cannot rule out the possibility that structural or chemical aspects of the synthetic particles enabled faster 13 C uptake than could be observed in natural systems, this study adds to the body of the recent work, suggesting that fast exchange processes are possible, likely through grain boundaries and other defects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupling to rotational manifolds to improve gas-phase pump–probe spectroscopic models

The physical picture of gas-phase optical transitions is normally presented as an isolated two-level system balanced by upward and downward processes. Isolated models assume a phenomenological treatment of collisional dephasing but do not strictly account for collisional population exchange with the rotational baths. While this assumption is valid under low-intensity conditions, where excitation is rate-limiting, isolated models can deviate from Beer’s Law at sufficient pressures and monochromatic intensities when both collisional broadening and power broadening are comparable to (or greater than) lifetime broadening, which are not uncommon conditions for cavity enhanced spectroscopies in the mid-IR spectral range. Although this problem has been addressed by rate-equation models for linear absorption measurements, a general treatment for multi-level quantum mechanical models suitable for non-linear absorption measurements (two-photon/two-color/pump–probe) is lacking. Isolated models require physical parameter inputs that disagree with expected values by at least an order of magnitude. These non-physical models undermine the ability to predict non-linear signal strengths under untested conditions and thereby limit the potential to optimize the sensitivity of non-linear spectroscopies and to expand their analytical applications (e.g., new analytes and/or buffer gases, changes in cavity free-spectral-range, changes in intracavity powers or wavelengths, and accurate investigation of physical phenomena). In this study, we derive bath-coupled models for gaseous pump–probe spectroscopy by application of the quantum Lindblad equation and detailed balance. Bath-coupled models are shown to fit data consistently across variations in intensity and agree with all physically expected values.

Cavity ring-down spectroscopy↗

Cavity Ring Down Spectroscopy of Cold Neutral Phenanthrene and Phenanthridine in Supersonic Jets

Here we study the effect of nitrogen insertion on the electronic spectra of polycyclic aromatic hydrocarbon (PAH) molecules measured under laboratory conditions that are relevant for comparison with astronomical data. We examine the case of the substitution of carbon atoms by nitrogen atoms in the benzenoid skeleton of phenanthrene (C 14 H 10 ), a prototype non-compact PAH. The vibronic transitions of the 2 1 A 1 (S 1 )←X 1 A 1 (S 0 ) electronic absorption band system of neutral phenanthrene (C 14 H 10 ) and phenanthridine (C 13 H 9 N) molecules seeded in a supersonic free jet expansion of argon gas are measured in the 315-345 nm region using the cavity ring down spectroscopy (CRDS) technique. Additional measurements of the absorption spectra of the phenanthrene, phenanthridine, and 1,10-phenanthroline (C 12 H 8 N 2 ) molecules isolated in 10-K solid argon matrices are also presented. The results obtained confirm that laboratory spectra of cold, isolated molecules obtained under astrophysically relevant conditions are required for a direct, unambiguous comparison with astronomical observations as well as for the understanding of the physical evolution of the interstellar medium.

Absorption band↗

A minor respiratory process with major global implications: is atmospheric methane oxidation in tree stems driven by stem respiration rather than microbial methanotrophy?

Tree stem surfaces are widely recognized as sites of carbon dioxide (CO₂) efflux and oxygen (O₂) influx, reflecting the dynamics of aerobic respiration of photosynthate substrates, such as sugars, delivered via the phloem. Stems are also largely considered passive conduits for methane (CH₄) produced in anoxic soils via microbial methanogenesis, where CH₄ is thought to be transported upward through the transpiration stream and/or diffusion and emitted through stem surfaces and the canopy. However, recent observations from dynamic stem chambers suggest that stems may also act as active sinks for atmospheric CH₄. Despite these findings, the extent and drivers of stem CH₄ consumption remain poorly characterized across biomes, species, and environmental gradients, and its quantitative relationship to stem respiration has not been established. Moreover, previous studies captured only snapshot fluxes, leaving diurnal patterns of CH₄ exchange uncharacterized. Here, we address these limitations by combining real-time measurements of stem CH₄ and O₂ uptake under ambient conditions in a California cherry tree, using a dynamic stem gas exchange system with three chambers receiving a continuous flow of ambient air and automated chamber and reference air sampling every 10 min. Our results confirm that stems of upland trees can actively consume both atmospheric CH₄ and O₂, but with decreasing temperature sensitivity as daily temperatures increase. Early mornings were marked by rapid influxes of both gases, followed by declining uptake as temperatures rose further. Methane uptake was tightly coupled with O₂ influx and represented a minor (0.012% ± 0.002%) fraction of stem respiratory activity, as determined by concurrent O₂ uptake. These findings suggest that while atmospheric CH₄ oxidation is a minor respiratory process in stems, it is strongly linked with stem physiological activity. This challenges the current assumption that terrestrial CH₄ uptake is driven solely by microbial methanotrophy and raises the possibility that living stem tissues may contribute to CH₄ oxidation through an as-yet-unidentified plant-based mechanism.

Atmospheric greenhouse gases↗

Influence of Benzene on the Optical Properties of Titan Haze Laboratory Analogs in the Mid-Visible

The Cassini Ion and Neutral Mass Spectrometer (Waite, Jr., et al., 2007) and the Composite Infrared Spectrometer (Coustenis, A., et al., 2007) have detected benzene in the upper atmosphere and stratosphere of Titan. Photochemical reactions involving benzene in Titan's atmosphere may influence polycyclic aromatic hydrocarbon formation, aerosol formation, and the radiative balance of Titan's atmosphere. We measure the effect of benzene on the optical properties of Titan analog particles in the laboratory. Using cavity ring-down aerosol extinction spectroscopy, we determine the real and imaginary refractive index at 532 nm of particles formed by benzene photolysis and Titan analog particles formed with ppm-levels of benzene. These studies are compared to the previous study by Hasenkopf, et a1. (2010) of Titan analog particles formed by methane photolysis.

Yoon, Y. Heidi↗

Coupling of torsion and OH-stretching in tert -butyl hydroperoxide. II. The OH-stretching fundamental and overtone spectra

We report the vibrational spectra of gas phase tert-butyl hydroperoxide have been recorded in the OH-stretching fundamental and overtone regions (Δv OH = 1–5) at room temperature using conventional Fourier transform infrared (Δv OH = 1–3) and cavity ring-down (Δv OH = 4–5) spectroscopy. In hydroperoxides, the OH-stretching and COOH torsion vibrations are strongly coupled. The double-well nature of the COOH torsion potential leads to tunneling splitting of the energy levels and, combined with the low frequency of the torsional vibration, results in spectra in the OH-stretching regions with multiple vibrational transitions. In each of the OH-stretching regions, both an OH-stretching and a stretch–torsion combination feature are observed, and we show direct evidence for the tunneling splitting in the OH-stretching fundamental region. We have developed two complementary vibrational models to describe the spectra of the OH-stretching regions, a reaction path model and a reduced dimensional local mode model, both of which describe the features of the vibrational spectra well. We also explore the torsional dependence of the OH-stretching transition dipole moment and show that a Franck–Condon treatment fails to capture the intensity in the region of the stretch–torsion combination features. The accuracy of the Franck–Condon treatment of these features improves with increasing Δv OH .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Sub-Ppm Instrument Response Suggests Higher Detection Limits Could Be Used to Quantify Methane Emissions from Oil and Gas Infrastructure

Quantifying and controlling fugitive methane emissions from oil and gas facilities remains essential for addressing climate goals, but the costs associated with monitoring millions of production sites remain prohibitively expensive. Current thinking, supported by measurement and simple dispersion modelling, assumes single-digit parts-per-million instrumentation is required. To investigate instrument response, the inlets of three trace-methane (sub-ppm) analyzers were collocated on a facility designed to release gas of known composition at known flow rates between 0.4 and 5.2 kg CH 4 h –1 from simulated oil and gas infrastructure. Methane mixing ratios were measured by each instrument at 1 Hertz resolution over nine hours. While mixing ratios reported by a cavity ring-down spectrometer (CRDS)-based instrument were on average 10.0 ppm (range 1.8 to 83 ppm), a mid-infrared laser absorption spectroscopy (MIRA)-based instrument reported short-lived mixing ratios far larger than expected (range 1.8 to 779 ppm) with a similar nine-hour average to the CRDS (10.1 ppm). We suggest the peaks detected by the MIRA are likely caused by a micrometeorological phenomenon, where vortex shedding has resulted in heterogeneous methane plumes which only the MIRA can observe. Further analysis suggests an instrument like the MIRA (an optical-cavity-based instrument with cavity size ≤10 cm3 measuring at ≥2 Hz with air flow rates in the order of ≤0.3 slpm at distances of ≤20 m from the source) but with a higher detection limit (25 ppm) could detect enough of the high-concentration events to generate representative 20 min-average methane mixing ratios. Even though development of a lower-cost, high-precision, high-accuracy instrument with a 25 ppm detection threshold remains a significant problem, this has implications for the use of instrumentation with higher detection thresholds, resulting in the reduction in cost to measure methane emissions and providing a mechanism for the widespread deployment of effective leak detection and repair programs for all oil and gas infrastructure.

03 NATURAL GAS↗

Ring-Down Spectroscopy for Characterizing a CW Raman Laser

.A relatively simple technique for characterizing an all-resonant intracavity continuous-wave (CW) solid-state Raman laser involves the use of ring-down spectroscopy. As used here, characterizing signifies determining such parameters as threshold pump power, Raman gain, conversion efficiency, and quality factors (Q values) of the pump and Stokes cavity modes. Heretofore, in order to characterize resonant-cavity-based Raman lasers, it has usually been necessary to manipulate the frequencies and power levels of pump lasers and, in each case, to take several sets of measurements. In cases involving ultra-high-Q resonators, it also has been desirable to lock pump lasers to resonator modes to ensure the quality of measurement data. Simpler techniques could be useful. In the present ring-down spectroscopic technique, one infers the parameters of interest from the decay of the laser out of its steady state. This technique does not require changing the power or frequency of the pump laser or locking the pump laser to the resonator mode. The technique is based on a theoretical analysis of what happens when the pump laser is abruptly switched off after the Raman generation reaches the steady state. The analysis starts with differential equations for the evolution of the amplitudes of the pump and Stokes electric fields, leading to solutions for the power levels of the pump and Stokes fields as functions of time and of the aforementioned parameters. Among other things, these solutions show how the ring-down time depends, to some extent, on the electromagnetic energy accumulated in the cavity. The solutions are readily converted to relatively simple equations for the parameters as functions of quantities that can be determined from measurements of the time-dependent power levels. For example, the steady-state intracavity conversion efficiency is given by G1/G2 1 and the threshold power is given by Pin(G2/G1)2, where Pin is the steady-state input pump power immediately prior to abrupt switch-off, G1 is the initial rate of decay of the pump field, and G2 is the final rate of decay of the pump field. Hence, it is possible to determine all the parameters from a single ring-down scan, provided that the measurements taken in that scan are sufficiently accurate and complete.

Matsko, Andrey↗

Optical and Probe Diagnostics Applied to Reacting Flows

The general theme of the research my NASA colleague and I have planned is "Optical and probe diagnostics applied to reacting flows". We plan to explore three major threads during the fellowship period. The first interrogates the flame synthesis of carbon nanotubes using aerosol catalysts. Having demonstrated the viability of the technique for nanotube synthesis, we seek to understand the details of this reacting system which are important to its practical application. Laser light scattering will reveal changes in particle size at various heights above the burner. Analysis of the flame gas by mass spectroscopy will reveal the chemical composition of the mixture. Finally, absorption measurements will map the nanotube concentration within the flow. The second thread explores soot oxidation kinetics. Despite the impact of soot on engine performance, fire safety and pollution, models for its oxidation are inhibited by uncertainty in the values of the oxidation rate. We plan to employ both optical and microscopic measurements to refine this rate. Cavity ring-down absorption measurements of the carbonaceous aerosol can provide a measure of the mass concentration with time and, hence, an oxidation rate. Spectroscopic and direct probe measurements will provide the temperature of the system needed for subsequent modeling. These data will be benchmarked against changes in soot nanostructures as revealed by transmission electron microscopic images from directly sampled material.

Ticich, Thomas M.↗

High-precision monitoring of outgassing species in model extreme ultraviolet photoresists with a cavity ring-down spectrometer

Background Extreme ultraviolet (EUV) photoresists play a pivotal role in advancing nanopatterning technologies by balancing image quality and sensitivity. The outgassing behavior of photoresist thin films under EUV and deep ultraviolet (DUV) exposure reveals chemical details relevant to their performance. Aim Here, we focus on utilizing an analytical technique not previously used in photolithography, the tabletop cavity ring-down spectrometer, to investigate outgassing dynamics in EUV photoresists, enabling precise chemical identification and deeper insights into resist processing. Approach The spectrometer’s enhanced laser path length (∼ 20 km) and broadband absorption capabilities in the C–H overtone region allow for sensitive and temporally resolved detection of mixtures of outgassed species. Using a model resist comprising a polymer matrix with a photoacid generator and quencher, we analyzed the influence of time delays between exposure and post-exposure bake (PEB) as well as storage under varying environmental conditions. Results Suppression of isobutylene outgassing and thickness loss was observed with extended delays between exposure and PEB, potentially linked to water absorption and acid deactivation. The technique proved highly effective in distinguishing subtle chemical differences between processing stages. Conclusions Delay times and their environmental conditions, particularly humidity, reduce outgassing and thickness loss of photoresists during PEB, suggesting decreased acid-driven deprotection. This can potentially impact sensitivity, defectivity, and roughness of resist patterns, necessitating precise monitoring and control.

Extreme ultraviolet photoresists↗