Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cascade control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Leveraging Disturbance Observer Based Torque Control for Improved Impedance Rendering with Series Elastic Actuators

The fidelity with which series elastic actuators (SEAs) render desired impedances is important. Numerous approaches to SEA impedance control have been developed under the premise that high-precision actuator torque control is a prerequisite. Indeed, the design of an inner torque compensator has a significant impact on actuator impedance rendering. The disturbance observer (DOB) based torque control implemented in NASA's Valkyrie robot is considered here and a mathematical model of this torque control, cascaded with an outer impedance compensator, is constructed. While previous work has examined the impact a disturbance observer has on torque control performance, little has been done regarding DOBs and impedance rendering accuracy. Both simulation and a series of experiments are used to demonstrate the significant improvements possible in an SEA's ability to render desired dynamic behaviors when utilizing a DOB. Actuator transparency at low impedances is improved, closed loop hysteresis is reduced, and the actuator's dynamic response to both commands and interaction torques more faithfully matches that of the desired model. All of this is achieved by leveraging DOB based control rather than increasing compensator gains, thus making improved SEA impedance control easier to achieve in practice.

Mehling, Joshua S.↗

Cascaded systems and methods for controlling energy use during a demand limiting period

A cascaded control system is configured to control power consumption of a building during a demand limiting period. The cascaded control system includes an energy use setpoint generator and a feedback controller. The energy use setpoint generator is configured to use energy pricing data and measurements of a variable condition within the building to generate an energy use setpoint during the demand limiting period. The feedback controller is configured to use a difference between the energy use setpoint and a measured energy use to generate a control signal for building equipment that operate to affect the variable condition within the building during the demand limiting period.

Wenzel, Michael J.↗

Modified Cascading Generalized Inverse Control Allocation

The current aviation revolution towards electric propulsion aircraft (e.g., electric vertical takeoff-and-landing) brings unique control challenges. These vehicles are typically over-actuated (more effectors than desired control outcomes), may require control strategies for the three phases of flight (hover, transition and cruise), and currently have limited electric power availability. These vehicle challenges bring the need for optimal control allocation to the forefront of research. A leading control allocation algorithm, used in current flight vehicles, is the Cascading Generalized Inverse (CGI). Unfortunately, the Cascading Generalized Inverse algorithm is unable to achieve some desired outcomes, it intermittently provides non-optimal allocations, and it may fail to preserve moment direction near maximal achievable outcomes. In this research, the shortcomings of the Cascading Generalized Inverse algorithm are addressed by augmenting the algorithm with Scalar Difference Quadratic unsaturation identification and location at each iteration. Rigorous theory is shown that the Modified Cascading Generalized Inverse performs better at obtaining optimal allocations for all attainable outcomes. Numerical case studies for over-actuated vehicles demonstrate resolution to the aforementioned deficiencies.

Control Allocation↗

Modified Cascading Generalized Inverse Control Allocation

The current aviation revolution towards electric propulsion aircraft (e.g., electric vertical takeoff-and-landing) brings unique control challenges. These vehicles are typically over-actuated (more effectors than desired control outcomes), may require control strategies for the three phases of flight (hover, transition and cruise), and currently have limited electric power availability. These vehicle challenges bring the need for optimal control allocation to the forefront of research. A leading control allocation algorithm, used in current flight vehicles, is the Cascading Generalized Inverse (CGI). Unfortunately, the Cascading Generalized Inverse algorithm is unable to achieve some desired outcomes, it intermittently provides non-optimal allocations, and it may fail to preserve moment direction near maximal achievable outcomes. In this research, the shortcomings of the Cascading Generalized Inverse algorithm are addressed by augmenting the algorithm with Scalar Difference Quadratic unsaturation identification and location at each iteration. Rigorous theory is shown that the Modified Cascading Generalized Inverse performs better at obtaining optimal allocations for all attainable outcomes. Numerical case studies for over-actuated vehicles demonstrate resolution to the aforementioned deficiencies.

Control Allocation↗

Evaluation of supply air temperature control performance with different control strategies at air handling units

Due to its nonlinear feature, supply air temperature control systems at air handling units using single-loop fixed gain control frequently suffer unstable response under dynamic conditions. This paper is aimed at identifying a more effective control strategy to stabilize the valve control and achieve desirable supply air temperature response under various operation conditions by evaluating three control strategies, cascade, gain scheduling and cascade plus gain scheduling controls. Firstly, a control-oriented model is developed and calibrated through open-loop tests. Then, the control issues with single-loop fixed gain control are evaluated through simulations and field tests, which indicates that the system has more aggressive response or becomes unstable under lower load conditions when the chilled-water flow rate is less than 0.1 L/s. Finally, three control strategies are proposed and evaluated. Further, the results reveal that all three proposed controls can achieve better robustness with the integral square error of supply air temperature decreased to 16%, 47% and 5%, respectively, under lower load condition. However, since high-frequency oscillation of the control valve occurs with cascade and cascade plus gain scheduling control, the gain scheduling control is recommended considering a trade-off among the supply air temperature response, valve lifetime and implementation complexity.

42 ENGINEERING↗

A Distributed Control Architecture for Cascaded H-Bridge Converter with Integrated Battery Energy Storage

Cascaded H-bridge topology has been used in grid-tied converters for battery energy storage system due to its modular structure. To fully utilize the converter’s modularity, this paper proposes a hierarchical distributed control architecture that consists of primary control, secondary control and battery state of charge (SOC) balancing control. Primary control ensures accurate current tracking while a distributed secondary control based on consensus algorithm is presented to regulate power sharing among modules and is proved to be stable theoretically. Here, a distributed SOC balancing control is further introduced to improve energy efficiency of battery energy storage system. Finally, the hierarchical distributed control strategy is implemented using hardware controllers and a software platform. Besides, a carrier phase shift control is also implemented to achieve multilevel output voltage and harmonic reduction. The experimental results demonstrate the performance of the proposed control scheme effectively.

25 ENERGY STORAGE↗

A Decoupled Droop Control Strategy for Cascaded Multicell Inverter with Low-Frequency Modulation

Cascaded multicell inverter (CMI), featured by its merits of modularity and fault-tolerance, is suitable for medium-voltage applications without using bulky step-up transformers. However, little research has reported grid-forming control of the CMI for the application in the power grid with high penetrations of inverter-interfaced generation. To bridge this research gap, this paper proposes a novel droop control strategy for the CMI with a low-frequency modulation to offer inertia and reactive power support to the power grid. A decoupled Q/V droop control strategy is proposed to eliminate the coupling effect from the P/ω control loop caused by the phase-angle difference between the voltages of the CMI and the grid. The output of the Q/V control loop is set as the reference voltage for each cell of the CMI, which makes the CMI naturally a voltage source to provide a grid-forming capability. Finally, the proposed control strategy shows great active and reactive power regulation and sharing capability, which is validated by simulation on two 100 kW, 2.4 kV CMIs connected in parallel to a power grid.

14 SOLAR ENERGY↗

A new approach to the digital redesign of continuous-time controllers

This paper presents a new method for digital redesign of both a continuous-time state-feedback control law and a cascaded analog controller. The concept of the Law of Mean from the integral calculus is utilized for the development of the equivalent digital controllers from the available analog controllers. A tuning parameter has been introduced into the digitally redesigned control gains so that the digitally controlled states will closely match the original continuous-time states. The proposed digital controllers give excellent performance.

Shieh, Leang-San↗

Comparison of calculated and experimental cascade performance for controlled-diffusion compressor stator blading

The mid-span section of a previously reported controlled-diffusion compressor stator has been experimentally evaluated in cascade. Measurements are taken over a range of incidence angles for blade chord Reynolds numbers from 470,000 to 690,000. Blade chord length is 12.7 cm, aspect ratio is 2.0, and solidity is 1.67. Measurements include conventional cascade performance parameters as well as blade surface pressures. Computations are made for the inviscid flow field, surface boundary layers, and loss for several of the blade inlet angle conditions, are compared against corresponding data.

Sanger, N. L.↗

Comparison of calculated and experimental cascade performance for controlled-diffusion compressor stator blading

The mid-span section of a previously reported controlled-diffusion compressor stator has been experimentally evaluated in cascade. Measurements are taken over a range of incidence angles for blade chord Reynolds numbers from 470,000 to 690,000. Blade chord length is 12.7 cm, aspect ratio is 2.0, and solidity is 1.67. Measurements include conventional cascade performance parameters as well as blade surface pressures. Computations are made for the inviscid flow field, surface boundary layers, and loss for several of the blade inlet angle conditions, are compared against corresponding data.

Sanger, N. L.↗

A cascaded coding scheme for error control and its performance analysis

A coding scheme is investigated for error control in data communication systems. The scheme is obtained by cascading two error correcting codes, called the inner and outer codes. The error performance of the scheme is analyzed for a binary symmetric channel with bit error rate epsilon <1/2. It is shown that if the inner and outer codes are chosen properly, extremely high reliability can be attained even for a high channel bit error rate. Various specific example schemes with inner codes ranging form high rates to very low rates and Reed-Solomon codes as inner codes are considered, and their error probabilities are evaluated. They all provide extremely high reliability even for very high bit error rates. Several example schemes are being considered by NASA for satellite and spacecraft down link error control.

Lin, Shu↗

Redesign and cascade tests of a supercritical controlled diffusion stator blade-section

A supercritical stator blade section, previously tested in cascade, and characterized by a flat-roof-top suction surface Mach number distribution, has been redesigned and retested. At near design conditions, the losses and air turning were improved over the original blade by 50 percent and 7 percent respectively. The key element in the improved performance was a small blade reshaping. This produced a continuous flow acceleration over the first one-third chord of the suction surface which successfully prevented a premature laminar separation bubble. Several recently available inviscid analysis and one fully viscous (Navier-Stokes) analysis code were used in the redesign process. The validity of these codes was enhanced by the test results.

Schmidt, J. F.↗

Redesign and cascade tests of a supercritical controlled diffusion stator blade-section

A supercritical stator blade section, previously tested in cascade, and characterized by a flat-roof-top suction surface Mach number distribution, has been redesigned and retested. At near design conditions, the losses and air turning were improved over the original blade by 50 percent and 7 percent, respectively. The key element in the improved performance was a small blade reshaping. This produced a continuous flow acceleration over the first one-third chord of the suction surface which successfully prevented a premature laminar separation bubble. Several recently available inviscid analysis codes and one fully viscous (Navier-Stokes) analysis code were used in the redesign process. The validity of these codes was enhanced by the test results. Previously announced in STAR as N84-22533

Schmidt, J. F.↗

Design Study for Bio-Oil Production from Biomass Using a Dual Fluidized-Bed Reactor

To evaluate the re-design and reconfiguration of a dual-fluidized bed (DFB) gasification system into a recirculating pyrolysis reactor, Computation Fluid Dynamic (CFD) simulations of the system were conducted. The Barracuda Virtual Reactor® computational particle fluid dynamic code was used to perform simulations of the pyrolysis process. Modeling of the chemical reaction kinetics for both gas phase and solid particle phase were included. The recirculating pyrolysis reactor shown in Fig. 1a is based on a bubbling-bed biomass pyrolyzer and a riser combustor to convert the remaining char. The operational differences in the re-configuration of the DFB gasification system into a recirculating pyrolysis system for the production of bio-oil are (1) replacement of a low-surface area inert bed material with a high-surface-area bed material that has acidic properties to provide catalytic activity for the production of bio-oil with reduced oxygen content, (2) lower temperature and residence time for bio-oil production from pyrolysis, (3) replacement of the fluidization gas in the bubbling bed pyrolyzer from steam to nitrogen, and (4) the reduction of pyrolyzer freeboard volume. The bed material used for catalytic pyrolysis is Sasol 300 (300-micron dia., bulk density 0.94 kg/l, and surface area 130 m2/g) and is a theta-alumina with mild acidity. This is in comparison with previous standard bed material Carbo HSP (430-micron dia., bulk density 2.01 kg/l, and surface area 0.03 m2/g) used for gasification. For bio-oil production, pyrolysis in the bubbling bed requires temperatures in the range of 550 C in comparison with gasification temperatures near 850 C. To attain this lower temperature requires management of the energy mass balances, with control of the bed material recirculation rate between bubbling bed pyrolyzer and riser combustor, the introduction of a nitrogen purge in the pyrolyzer, and adjusting the pressure balance between the two vessels. To extract bio-oil from the pyrolysis reactor with a snorkel, two different freeboard configurations were evaluated. In Fig. 1 b the existing high freeboard configuration is shown and in Fig. 1 c the reduced freeboard design is presented. The introduction of a nitrogen purge for the high free board configuration provided the highest bio-oil production from the CFD simulations. To decrease the bed-material circulation rate, primary and secondary air on the combustor side were reduced, and the pressure on the combustor was slightly increased. A portion of the biomass and bio-oil was observed to be transported to the combustor, leading to a smaller pyrolysis yield. The control of the pyrolyzer temperature is performed by controlling the circulation rate. Good fluidization of the bubbling bed and cascade PID control are required to keep the temperature from oscillating due to large time delay experienced when changing primary and secondary air. (a) (b) (c) Figure 1. (a) Dual Fluidized Bed pyrolysis system configuration, (b) mole fraction of nonpolar biooil in high freeboard configuration, and (c) mole fraction of nonpolar bio-oil in low freeboard configuration with nitrogen purge introduced in both configurations.

BASIC BIOLOGICAL SCIENCES,BIOMASS FUELS↗

A cascaded coding scheme for error control and its performance analysis

A coding scheme for error control in data communication systems is investigated. The scheme is obtained by cascading two error-correcting codes, called the inner and outer codes. Its error performance is analyzed for a binary symmetric channel with bit-error rate epsilon less than 1/2. It is shown that, if the inner and outer codes are chosen properly, high reliability can be attained even for a high-channel bit-error rate. Specific examples with inner codes ranging from high rates and Reed-Solomon codes as outer codes are considered, and their error probabilities evaluated. They all provide high reliability even for high bit-error rates, say 0.1-0.01. Several example schemes are being considered for satellite and spacecraft downlink error control.

Kasami, Tadao↗

A cascaded coding scheme for error control and its performance analysis

A coding scheme for error control in data communication systems is investigated. The scheme is obtained by cascading two error correcting codes, called the inner and the outer codes. The error performance of the scheme is analyzed for a binary symmetric channel with bit error rate epsilon < 1/2. It is shown that, if the inner and outer codes are chosen properly, extremely high reliability can be attained even for a high channel bit error rate. Various specific example schemes with inner codes ranging from high rates to very low rates and Reed-Solomon codes are considered, and their probabilities are evaluated. They all provide extremely high reliability even for very high bit error rates, say 0.1 to 0.01. Several example schemes are being considered by NASA for satellite and spacecraft down link error control.

Lin, S.↗

Coding for reliable satellite communications

This research project was set up to study various kinds of coding techniques for error control in satellite and space communications for NASA Goddard Space Flight Center. During the project period, researchers investigated the following areas: (1) decoding of Reed-Solomon codes in terms of dual basis; (2) concatenated and cascaded error control coding schemes for satellite and space communications; (3) use of hybrid coding schemes (error correction and detection incorporated with retransmission) to improve system reliability and throughput in satellite communications; (4) good codes for simultaneous error correction and error detection, and (5) error control techniques for ring and star networks.

Gaarder, N. T.↗