Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capillary discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

22 records · Page 2

Optimizing the Fabrication of Electrospun Nanofibrous Membrane Using Fractional Factorial Design

Electrospinning, a simple and easily tunable technique that utilizes the force balance between the electrostatic force and the solution surface tension to fabricate membranes out of 1D nanostructured fibers, has garnered much interest especially from the nanotechnology community. Depending on the morphology of the fibers, electrospun membrane has found its way in a wide range of applications, such as oil-water separation, desalination, tissue engineering, and batteries. During an electrospinning process, many factors can affect the morphology of the products, such as viscosity of the solution, voltage supply, discharge distance, feed rate of the solution, and electrospinning time. In this work, we investigated the impacts of the most important parameters on the morphology of electrospun fibrous membrane based on the fractional factorial design. We evaluated the electrospun fibrous membrane morphology using scanning electron microscopy (SEM) and capillary flow porometry. Poly (vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) was chosen for the current study due to its interesting and versatile functionalities including superior hydrophobicity, high free volume, and piezoelectricity. This work provides valuable insight for the fabrication of electrospun membranes, especially for tailoring membrane properties in accordance with any targeted applications.

Zhao, Yajing↗

Temporal persistence of postfire flood hazards under present and future climate conditions in southern Arizona, USA

Changes to soil hydraulic properties that reduce infiltration capacity following fire can increase flash flood risks. These risks are exacerbated by rainfall intensification associated with a warming climate. However, the potential effects of climate-change-driven rainfall intensification on postfire floods remain largely unexplored. Using rainfall and runoff observations from a 49.4 km 2 watershed in southern Arizona, USA, and a hydrologic model (KINEROS2), we examined the temporal evolution following a historic fire of three crucial hydrologic parameters: soil saturated hydraulic conductivity (K sp ), net capillary drive (G p ), and hydraulic roughness (n c ). We explored how the effect of fire on these parameters may influence peak flow under future climate scenarios derived from CMIP6, specifically the medium emissions scenario (SSP2-4.5) and high emissions scenario (SSP5-8.5). Results demonstrate an increase in K sp from 11 mm h −1 in the first postfire year to 60 mm h −1 in postfire year 3. G p similarly increased from 19 mm in the first postfire year to 30 mm in the third, while nc was relatively constant. The highest simulated Q p occurred in the first postfire year. Under the SSP2-4.5 scenario, the likelihood of a 100-year flood is projected to be twice as large by the middle of the century relative to its historical magnitude. Simulations further indicate that the maximum expected discharge associated with a postfire flood, as derived from historical data, could be triggered by a 10-year rainstorm under the SSP5-8.5 scenario by the late century. Simulations also demonstrate that rainfall intensification will lead to greater persistence of elevated flood hazards following fire by the late century under both the SSP2-4.5 and the SSP5-8.5 scenarios.

54 ENVIRONMENTAL SCIENCES↗

Interfacial Solar Evaporation by a 3D Graphene Oxide Stalk for Highly Concentrated Brine Treatment

In this study, we demonstrate a 3-dimensional graphene oxide (3D GO) stalk that operates near the capillary wicking limit to achieve an evaporation flux of 34.7 kg m -2 h -1 under 1 sun conditions (1 kW/m 2 ). This flux represents nearly a 100 times enhancement over a conventional solar evaporation pond. Interfacial solar evaporation traditionally uses 2D evaporators to vaporize water using sunlight, but their low evaporative water flux limits their practical applicability for desalination. Some recent studies using 3D evaporators demonstrate potential for more efficient water transfer, but the flux improvement has been marginal because of a low evaporation area index (EAI), which is defined as the ratio of the total evaporative surface area to the projected ground area. By using a 3D GO stalk with an ultrahigh EAI of 70, we achieved nearly a 20-fold enhancement over a 2D GO evaporator. The 3D GO stalk also exhibited additional advantages including omnidirectional sunlight utilization, a high evaporation flux under dark conditions from more efficient utilization of ambient heating, a dramatic increase of the evaporation rate by introducing wind, and scaling resistance in evaporating brines with a salt content of up to 17.5 wt %. This performance makes the 3D GO stalk well suited for the development of a low-cost, reduced footprint technology for zero liquid discharge in brine management applications.

3D evaporator↗

Modeling Efforts to Gain Insight into Historical Leak Events from the Single-Shell Tank A-105 in the Hanford 241-A Tank Farm - 20113

The 241-A Tank Farm is a single-shell tank (SST) farm constructed to store process waste from Hanford nuclear operations. Millions of gallons of nuclear waste were stored in the 241-A Tank Farm SSTs and some of the SSTs leaked in the past. In addition, spills and pipeline leaks during transfers and storage and intentional discharges to cribs and trenches resulted in releasing waste to the ground. Tank liner leaks are referred to as 'leaks' and all other discharges to the soil are referred to as 'releases.' Liquid waste that could be removed by pumping has been removed from all of the SSTs to reduce the potential for future leaks. The most significant historical leak event in 241-A Tank Farm occurred in 1965 when tank A-105 experienced a pressurized steam event. This event resulted in damage to the inner steel liner flooring of A-105, which was separated from the sidewalls over part of its circumference and buckled up to 2.5 m, vertically. During this event up to 7,570 L of contaminated liquid may have leaked to the adjacent soil. This leak occurred under extreme temperature and pressure conditions. Modeling efforts to better understand the nature and extent of historical leaks from subsurface SSTs that were used to store highly radioactive, self-boiling liquid wastes at 241-A Tank Farm have recently been undertaken. These efforts have compiled the available historical information to support a preliminary non-isothermal, multiphase flow and chemical transport modeling effort to re-create the conditions under which the leaks occurred and to formulate a conceptual model as to the extent and distribution of leaked radioactive contaminants in the adjacent soil material. The focus of this work was on developing an understanding of the key features, processes and bounding conditions related to tank A-105 leak events that occurred in the 1960's. The activities include estimation of leak composition, non-isothermal multiphase flow and transport modeling, and geochemical modeling. The STOMP{sup C} Water-Air-Energy modeling code was utilized to implement the three-dimensional representation of the subsurface tank and the surrounding flow field. Once constructed, the model was used to evaluate the conceptual understanding of leaks originating from different parts of the tank under the elevated temperature boundary conditions that were imposed by surrounding tanks at the time of the historical leaks. The chemical evolution of the liquid waste was also evaluated as it leaked from the tank under transient pressure and temperature gradients. The results of the preliminary evaluation suggested the presence of a heat-pipe effect beneath tank A-105 in which water vapor at an elevated temperature is driven away from the base of the tank to a position where water vapor cools, condenses and is then drawn back toward the tank by the strong capillary attraction of the dry soil. A non-sorbing contaminant (Tc-99) was introduced into this flow field to better understand the potential distribution patterns of leaked contaminants that may have occurred during the historical leak events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗