Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capacity change”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Leaf gas exchange of Andropogon gerardii Vitman, Panicum virgatum L., and Sorghastrum nutans (L.) Nash in a tallgrass prairie

Net CO2 assimilation as a function of internal CO2 and stomatal conductance to water vapor were measured on blades of the C4 grasses Andropogon gerardii Vitman, Panicum virgatrum L., and Sorghastrum nutans (L.) Nash in northeast Kansas over two growing seasons to determine the comparative physiological responses of these dominant grasses of the tallgrass prairie to environmental variables. The response of dark respiration to temperature and of net assimilation to CO2 concentration and absorbed quantum flux differed little among species. A. gerardii had lower potential photosynthetic rates at internal CO2 concentrations below saturation than P. virgatum and S. nutans, but net assimilation under ambient conditions was similar in the three species. Net assimilation and both the initial slope of assimilation versus internal CO2 curves and the maximum potential assimilation rate decreased as leaf water potential declined in blades of A. gerardii and S. nutans. Changes in assimilation capacity were paralleled by changes in stomatal conductance that were similar in all three species. The strong correlations among processes regulating leaf CO2 assimilation and transpiration in A. gerardii, P. virgatum, and S. nutans suggest that the processes are tightly and similarly coupled in these grasses over a wide range of environmental conditions encountered in the tallgrass prairie.

Polley, H. W.↗

Characteristics of storage related capacity loss in Ni/H2 cells

The changes in the capacity, voltage and pressure profile of flight configuration Ni/H2 cells when they are stored for extended periods is examined. The Ni/H2 cells exhibit capacity fade phenomenon regardless of their design when they are stored at room temperature. Capacity loss also occurs if old cells (5 years old) are stored in a very low rate trickle charge (C/200 rate) condition. A periodic recharge technique leads to pressure rise in the cells. Conventional trickle charge (C/100 rate) helps in minimizing or eliminating the second plateau which is one of the characteristics of the capacity fade phenomenon.

Vaidyanathan, Hari↗

Effect of aerobic capacity on Lower Body Negative Pressure (LBNP) tolerance in females

This investigation determined whether a relationship exists in females between: (1) aerobic capacity and Lower Body Negative Pressure (LBNP); and (2) aerobic capacity and change in LBNP tolerance induced by bed rest. Nine females, age 27-47 (34.6 plus or minus 6.0 (Mean plus or minus SD)), completed a treadmill-graded exercise test to establish aerobic capacity. A presyncopal-limited LBNP test was performed prior to and after 13 days of bed rest at a 6 deg head-down tilt. LBNP tolerance was quantified as: (1) the absolute level of negative pressure (NP) tolerated for greater than or equal to 60 sec; and (2) Luft's Cumulative Stress Index (CSI). Aerobic capacity was 33.3 plus or minus 5.0 mL/kg/min and ranged from 25.7 to 38.7. Bed rest was associated with a decrease in NP tolerance (-9.04 1.6 kPa(-67.8 plus or minus 12.0 mmHg) versus -7.7 1.1 kPa(-57.8 plus or minus 8.33 mmHg); p = 0.028) and in CSI (99.4 27.4 kPa min(745.7 plus or minus 205.4 mmHg min) versus 77.0 16.9 kPa min (577.3 plus or minus mmHg min); p = 0.008). The correlation between aerobic capacity and absolute NP or CSI pre-bed rest did not differ significantly from zero (r = -0.56, p = 0.11 for NP; and r = -0.52, p = 0.16 for CSI). Also, no significant correlation was observed between aerobic and pre- to post-rest change for absolute NP tolerance (r = -0.35, p = 0.35) or CSI (r = -0.32, p = 0.40). Therefore, a significant relationship does not exist between aerobic capacity and orthostatic function or change in orthostatic function induced by bed rest.

Moore, Alan D., Jr.↗

Experimental Characterization of a Composite Morphing Radiator Prototype in a Relevant Thermal Environment

For future long duration space missions, crewed vehicles will require advanced thermal control systems to maintain a desired internal environment temperature in spite of a large range of internal and external heat loads. Current radiators are only able to achieve turndown ratios (i.e. the ratio between the radiator's maximum and minimum heat rejection rates) of approximately 3:1. Upcoming missions will require radiators capable of 12:1 turndown ratios. A radiator with the ability to alter shape could significantly increase turndown capacity. Shape memory alloys (SMAs) offer promising qualities for this endeavor, namely their temperature-dependent phase change and capacity for work. In 2015, the first ever morphing radiator prototype was constructed in which SMA actuators passively altered the radiator shape in response to a thermal load. This work describes a follow-on endeavor to demonstrate a similar concept using highly thermally conductive composite materials. Numerous versions of this new concept were tested in a thermal vacuum environment and successfully demonstrated morphing behavior and variable heat rejection, achieving a turndown ratio of 4.84:1. A summary of these thermal experiments and their results are provided herein.

Bertagne, Christopher L.↗

Performance of a hybrid chemical/mechanical heat pump

The authors present the design and preliminary results of the performance of a hybrid chemical/mechanical, low-lift (20 C) heat pump. Studies have indicated that this heat pump has several advantages over the traditional single fluid vapor compression (reverse Rankine) heat pump. Included in these benefits are: 1) increased COPc due to the approximation of the cycle to the Lorenz cycle and due to the availability of the heat of solution, along with the heat of vaporization, to provide cooling; and 2) ease of variation in system cooling capacity by changing the fluid composition. The system performance is predicted for a variety of refrigerant-absorbent pairs. Cooling capacity is determined for systems operating with ammonia as the refrigerant and lithium nitrate and sodium thiocyanate as the absorbents and also with water as the refrigerant and magnesium chloride, potassium hydroxide, lithium bromide, sodium hydroxide, and sulfuric acid as the absorbents. Early indications have shown that the systems operating with water as the refrigerant operate at 2-4 times the capacity of the ammonia-refrigerant-based systems. Using existing working fluids in the proposed innovative design, a coefficient-of-performance improvement of 21 percent is possible when compared to the best vapor compression systems analyzed.

Silvestri, John J.↗

Performance and Safety Characteristics of Sanyo NiCd Cells

NiCd batteries are widely used for high drain applications like power tools and also in other portable equipment like cameras, PCs, etc. NASA and Dreamtime Holdings, Inc. worked together to have the capability of a High Definition TV (HDTV) on the ISS and Space Shuttle. The Sanyo HD camcorder was used on the STS 105 fight in July, 2001 . The camcorder used two versions of a NiCd battery. One was a cOlnmercial off-the-shelf Sony BP90 battery pack that had Sanyo NiCd D cells. The other was a modified battery (FBP-90) made by Frezzi Energy, which also had the same Sanyo NiCd D cells. The battery has 10 NiCd D cells in series to form a 12 V pack with 5.0 Ah capacity. Our current study involved the perforn1ance and abuse tests on the Sanyo NiCd 5.0 Ah D cells. The best combination of charge/discharge current rate is 0.3C for charge and 1/2e for discharge within 200 cycles. No significant changes in capacity were observed in 200 cycles. The cell also showed capability of 5C (25.0A) high rate discharge. In overcharge and overdischarge tests, all tested cells passed the tests without venting. In imbalance tests, the battery pack could be charged and discharged only at relatively low current. At charge current of 1.0A or less, the imbalanced cells in the battery pack displayed relatively high temperatures during charge or discharge. The cells functioned normally during internal short and no mishap occurred during external short. Cells passed exposure tests at 80 C and no leakage till 150 C during heat-tovent tests.

Deng, Yi↗

Deep Space Mission Trend Analyses: A Briefing to the Next Generation EBRE Study Team

Determination of stakeholder needs for next generation implementations necessitates a multi ]pronged approach. . Future mission set analyses provide a lower gbound h for some of these needs. . Earth ]based analogies provide an upper gbound h for some of these needs. . Interpreting the results requires being mindful of both the near ]term contextual factors and long ]term factors that are in play. . In the context of last year fs analyses, the current budget environment, the potential Pu ]238 shortage, and SMD fs gsingle 34m only h policy may, collectively, create a future deep space mission set that, from a capacity and end ]to ]end link difficulty standpoint, is no more challenging than it is today. . Nonetheless, data rates and volumes continue to increase, suggesting capability and spectrum challenges ahead. These results agree with the results from the Earthbased analogies. . Emerging developments such as smallsats and distributed spacecraft could significantly change the capacity and end ]to ]end link difficulty picture.

future mission analysis↗

Measurement of the Heat Capacity of He-II Under a Heat Current Near the Lambda Transition

We present preliminary measurements of the heat capacity of superfluid helium-4 under an applied heat current near the lambda transition. The calorimeter is a standard cylindrical thermal conductivity cell with a 0.6 mm gap between two copper endplates. The sidewall is made of stainless steel. A heat current density in the range of 1 to 4 microW/sq cm is applied through the helium sample while a pulse method is used to measure the heat capacity. Temperature changes are recorded with high-resolution thermometers (HRTs) located on the top and bottom endplates. Corrections are made to the readings of the HRTs to account for the Kapitza boundary resistance and the anomalous Kapitza boundary resistance. After the corrections, both the top and the bottom HRTs. give the same heat capacity values. The heat capacity is found to be much larger than the prediction of recent theories. We also plotted our data on a scaled plot to test the prediction of scaling by the theories. The result and its interpretation will be presented. The cell height was deliberately made to be thin to reduce the effects of gravity. Nonetheless, gravity is expected to have significant effects on the heat capacity data in the temperature range of our measurement. A space experiment would remove this unwanted gravity effect and allow the true physics to be examined. Moreover, in the absence of gravity, a deeper cell can be used allowing HRTs to be mounted on to the sidewall providing direct measurements of the helium temperature, unaffected by the anomalous Kapitza boundary resistance.

Harter, Alexa W.↗

Integrated Demand Management: Concepts and Procedures

This report provides a comprehensive description of the Integrated Demand Management concept. Motivation: NASA’s Integrated Demand Management (IDM) research explores the idea that, under certain conditions, time-based flow management (TBFM) arrival operations can benefit from the coordinated use of a strategic traffic management initiative (TMI) to “precondition” the inbound demand. The research was motivated by the observation that TBFM was usually turned off during convective weather, even in facilities where it was routinely used. Our hypothesis was that strategic adjustments to the inbound traffic so that it provided a better match to the off-nominal changes in capacity observed during these conditions could enable TBFM scheduling to continue to provide effective support for arrival traffic management. Concept: IDM proposes that a TMI (e.g., a Collaborative Trajectory Options Program, or CTOP) be used to adjust the rate and/or geographic distribution across flows of the traffic inbound to a high-demand, TBFM-managed airport before that traffic reaches the TBFM planning horizon. After this strategic preconditioning, TBFM can then tactically fine-tune the demand to deliver a well-managed, orderly feed to the destination airport. Coordinated use of these two flow management capabilities is intended to improve system performance in terms of: • Equity of ground delay assignment, avoiding excessive ground delay for TBFM-scheduled departures, without penalizing longer flights; • Throughput, by distributing traffic to maximize use of available capacity; • Predictability for operators, providing advance notice about the impact on individual flights; • Increased flexibility, supporting operator mitigation strategies such as slot swapping or trajectory options; • Efficiency of flight operations, using ground delay more effectively and reducing airborne delay. The operational description in this document highlights how the IDM concept builds upon already existing tools and procedures, and also indicates where tool enhancements could facilitate conduct of IDM operations. However, enhanced tools are not a requirement for concept introduction. In fact, initial deployment that focused on training procedures and rationale for coordinated use of TFMS and TBFM, without changes to existing tools, might be a simpler way to introduce and to familiarize traffic managers with the idea of preconditioning. The concept and procedures described in this document can hopefully provide useful guidance for introduction of IDM into field operations..

IDM↗

Principles of Gravitational Biology

Physical principles of gravitation are enumerated, including gravitational and inertial forces, weight and mass, weightlessness, size and scale effects, scale limits of gravitational effects, and gravity as biogenic factor. Statocysts, otolithic organs of vertebrates, gravity reception in plants, and clinostat studies for gravitation orientation are reviewed. Chronic acceleration is also studied, as well as physiology of hyper and hypodynamic fields. Responses of animals to a decreased acceleration field are examined, considering postural changes, work capacity, growth, and physiologic deadaptation.

Arthur H Smith↗

The first dedicated life sciences mission - Spacelab 4

The details of the payload and the experiments in Spacelab 4, the first Spacelab mission dedicated entirely to the life sciences, are discussed. The payload of Spacelab 4, carried in the bay of the Shuttle Orbiter, consists of 25 tentatively selected investigations combined into a comprehensive integrated exploration of the effects of acute weightlessness on living systems. The payload contains complementary designs in the human and animal investigations in order to validate animal models of human physiology in weightlessness. Animals used as experimental subjects will include squirrel monkeys, laboratory rats, several species of plants, and frog eggs. The main scientific objectives of the investigations include the study of the acute cephalic fluid shift, cardiovascular adaptation to weightlessness, including postflight reductions in orthostatic tolerance and exercise capacity, and changes in vestibular function, including space motion sickness, associated with weightlessness. Other scientific objective include the study of red cell mass reduction, negative nitrogen balance, altered calcium metabolism, suppressed in vitro lymphocyte reactivity, gravitropism and photropism in plants, and fertilization and early development in frog eggs.

Cramer, D. R.↗

Adaptability of the oxidative capacity of motoneurons

Previous studies have demonstrated that a chronic change in neuronal activation can produce a change in soma oxidative capacity, suggesting that: (i) these 2 variables are directly related in neurons and (ii) ion pumping is an important energy requiring activity of a neuron. Most of these studies, however, have focused on reduced activation levels of sensory systems. In the present study the effect of a chronic increase or decrease in motoneuronal activity on motoneuron oxidative capacity and soma size was studied. In addition, the effect of chronic axotomy was studied as an indicator of whether cytoplasmic volume may also be related to the oxidative capacity of motoneurons. A quantitative histochemical assay for succinate dehydrogenase activity was used as a measure of motoneuron oxidative capacity in experimental models in which chronic electromyography has been used to verify neuronal activity levels. Spinal transection reduced, and spinal isolation virtually eliminated lumbar motoneuron electrical activity. Functional overload of the plantaris by removal of its major synergists was used to chronically increase neural activity of the plantaris motor pool. No change in oxidative capacity or soma size resulted from either a chronic increase or decrease in neuronal activity level. These data indicate that the chronic modulation of ionic transport and neurotransmitter turnover associated with action potentials do not induce compensatory metabolic responses in the metabolic capacity of the soma of lumbar motoneurons. Soma oxidative capacity was reduced in the axotomized motoneurons, suggesting that a combination of axoplasmic transport, intracellular biosynthesis and perhaps neurotransmitter turnover represent the major energy demands on a motoneuron. While soma oxidative capacity may be closely related to neural activity in some neural systems, e.g. visual and auditory, lumbar motoneurons appear to be much less sensitive to modulations in chronic activity levels.

NASA Discipline Musculoskeletal↗

Pulmonary function in men after oxygen breathing at 3.0 ATA for 3.5 h

A complete description of pulmonary measurements obtained after continuous O2 exposure of 13 healthy men at 3.0 ATA for 3.5 h is presented. Measurements included flow-volume loops, spirometry, and airway resistance(n = 12); CO diffusing capacity (n = 11); closing volumes (n= 6); and air vs. HeO2 forced vital capacity maneuvers (n = 5). The average difference in maximum mid expiratory flows at 50 percent vital capacity on air and HeO2 was found to be significantly reduced postexposure by 18 percent. Raw and CO diffusing capacity were not changed postexposure. It is concluded that the relatively large change in forced expiratory flow at 25-75 percent of vital capacity compared with the mean forced expiratory volume in 1 s, the reduction in density dependence of flow, and the normal Raw postexposure are all consistent with flow limitation in peripheral airways as a major cause of the observed reduction in expiratory flow.

Clark, J. M.↗

Design and experimental evaluation of a high temperature radial turbine with a moveable sidewall nozzle

The uncooled, 2.27 kg/sec mass flow radial turbine designed to operate at 1477 K in the gas generator of an advanced, variable-capacity 683 kW turboshaft engine was configured with a cooled, movable sidewall nozzle capable of changing the stage flow capacity from 50 to 100 percent of maximum. Overall performance test data were obtained in a turbine test rig that duplicated engine Reynolds numbers; attention is given to the changing of flow capacity by moving the hub or shroud sidewall, vane sidewall leakage, vaneless space sidewall geometry, and nozzle-cooling injection. Data are presented in the form of turbine flow, efficiency, work parameter, and performance mappings.

Rogo, Casimir↗