At least 37 records · Page 2

Development of a Metabolic Cage for Simulation of Weightlessness in a Laboratory Environment

Astronauts experience many physiological changes during spaceflight and exposure to microgravity. There is a headwardshift of fluids, muscles atrophy, and changes occur in the body's bone structure and hormone levels. This paper describes a unique metabolic cage that was developed to evaluate ground simulation of these effects. Hindlimb or tail suspension in rats has been studied as a model to create the effects of microgravity in order to study how to counteract them. This suspension model, developed by Holton, accurately simulates the effects of weightlessness during spaceflight by unloading the hindlimbs and producing a head-ward shift of fluids. However, obtaining quantitative data on the nutritional state, the gastrointestinal and renal function of these animals has not been possible, until now. Using Holton's tail suspension model, the new metabolic suspension cage effectively separates urine and feces samples for analysis allowing investigators to examine the effects of microgravity in many complex body systems. A description of the cage system, its design, and results of its use is provided along with pictures and details for replication of the cages.

Mulenburg, Gerald M.↗

A tethering system for direct measurement of cardiovascular function in the caged baboon

A device suitable for the continuous measurement of physiological activity in large, conscious monkeys has permitted the direct recording of systemic arterial blood pressure and heart rate in caged baboons. The device comprises a lightweight fiberglass backpack, retained in place on the baboon by a thoracic elastic band and shoulder straps, and a flexible stainless steel tether connecting the pack to an electrocannular slip-ring in the top center of the baboon's cage. A chronically indwelling arterial catheter inserted retrograde into the abdominal aorta via the internal iliac artery and connected to a small pressure transducer on the pack provides direct measurement of blood pressure and heart rate. Body fluids can be sampled or drugs administered via an indwelling catheter in the inferior vena cava. Electrical and fluid connections between the fiberglass pack and recording and infusion equipment located outside the cage pass through the flexible tether and remain protected from the subject. The reliability of the tethering system has been demonstrated in physiological, pharmacological, and behavioral experiments with baboons.

Byrd, L. D.↗

Behavioral study of ultradian activity periods of mice enclosed in experimental cages of different dimensions

Male mice are enclosed in cages of different dimensions (cage A - 23x8x8 cm., cage B - 36x27x17 cm.), in an alternating light/dark regimen, at an ambient temperature of 22 to 23 C. The successions of the behavioral sequences of ultradian activity periods are noticed by direct observation during 11 consecutive hours in light. The experimental situation modifies the mean duration time and the behavioral organization of each activity period. However, the comparison of the overall activity time lengths and the comparison of the overall behavioral frequencies suggest that the energy spent per mouse is constant.

Guillot, A.↗

High pressure oxygen turbopump bearing cage stability analyses

The low service life of the high pressure oxygen turbopump (HPOTP) bearings used in the space shuttle main engine was examined by use of the Battelle "BASDAP' bearing computer stability model. The dynamic instability of the bearing cage resulted in excessive wear and eventual failure of the unit. By maintaining a cage/race clearance of no more than 0.25 millimeters (0.010 inches), ball/pocket clearance of no less than 0.54 millimeters (0.025 inches), dynamic balancing of the cages, and maintaining adequate lubricant films between the balls and races, cage instability and subsequent bearing degradation can be reduced.

Merriman, T. L.↗

Cleaning Animals' Cages With Little Water

Proposed freeze/thaw method for cleaning animals' cages requires little extra weight and consumes little power and water. Cleaning concept developed for maintaining experimental rat cages on extended space missions. Adaptable as well to similar use on Earth. Reduces cleaning time. Makes use of already available facilities such as refrigerator, glove box, and autoclave. Rat waste adheres to steel-wire-mesh floor of cage. Feces removed by loosening action of freezing-and-thawing process, followed by blast of air.

Harman, Benjamin J.↗

Metabolic Cage for a Space Flight Model in the Rat

The new cage facilitates the collection of 24-h specimens of separated urine and feces apparently uncontaminated by food, as required for precise nutritional and metabolic studies, while maintaining the large floor area and suspension method of Holton's design (3). Although the cage was evaluated, using 6-month-old rats weighing 408 to 488 g, it can be easily adjusted for smaller rats. It also was successfully used to collect post-flight urine after the recent Spacelab Life Sciences-2 space shuttle flight. With its flexibility and ease of use, this new cage design adds a new tool to study the physiologic effects of simulated space flight and other disuse conditions.

Jennifer S Harper↗

AAH Cage Out-Link and In-Link Antenna Characterization

This final report encapsulates the accomplishments of the third year of work on an Advanced Biotelemetry System (ABTS). Overall MU/ABTS project objectives are to provide a biotelemetry system that can collect data from and send commands to an implanted biotransceiver. This system will provide for studies of rodent development in space. The system must be capable of operating in a metal animal cage environment. An important goal is the development of a small, "smart", micropower, -channel data output and single channel command implantable biotransceiver with eight input capabilities with the flexibility for easy customization for a variety of physiologic investigations. The NASA Ames/Marquette University Joint Research work has been devoted to the system design of such a new state of the art biotelemetry system, having multiple physiologic inputs, and bi-directional data transfer capabilities. This work has provided a successful prototype system that connects, by two-way radio links, an addressable biotelemetry system that provides communication between an animal biotelemeter prototype and a personal computer. The operational features of the prototype system are listed below: Two-Way PCM Communication with Implanted Biotelemeter Microcontroller Based Biotelemeter Out-Link: Wideband FSK (60 kbaud) In-Link: OOK (2.4 kbaud) Septum Antenna Arrays (In/Out-Links) Personal Computer Data Interface The important requirement of this third year's work, to demonstrate two-way communication with transmit and receive antennas inside the metal animal cage, has been successfully accomplished. The advances discussed in this report demonstrate that the AAH cage antenna system can provide Out-link and In-link capability for the ABTS bi-directional telemetry system, and can serve as a benchmark for project status.

Jeutter, Dean C.↗

Flow Cage Assemblies

Apparatus, systems and methods for implementing flow cages and flow cage assemblies in association with high pressure fluid flows and fluid valves are provided. Flow cages and flow assemblies are provided to dissipate the energy of a fluid flow, such as by reducing fluid flow pressure and/or fluid flow velocity. In some embodiments the dissipation of the fluid flow energy is adapted to reduce erosion, such as from high-pressure jet flows, to reduce cavitation, such as by controllably increasing the flow area, and/or to reduce valve noise associated with pressure surge.

Sherrit, Stewart↗

Bearings use dry self-lubricating cage materials

Rolling element bearings in spacecraft mechanical systems use solid lubricant composites of polytetrafluoroethylene in the bearing cage which functions as the lubricant reservoir. The cage spaces the rolling elements equally and provides the lubricant at the bearing load-carrying surface.

Anderson, W. J.↗

High-temperature bearing-cage materials

Evaluation tests conducted at temperatures of 500 and 700 degrees F reveal that S-Monel and AISI M-1 steel are suitable as high temperature cage materials for precision bearings. The area of the wear scar in the cage pocket that developed during the test was used as the measure of wear.

Anderson, W. J.↗

Caging Mechanism for a drag-free satellite position sensor

A disturbance compensation system for satellites based on the drag-free concept was mechanized and flown, using a spherical proof mass and a cam-guided caging mechanism. The caging mechanism controls the location of the proof mass for testing and constrains it during launch. Design requirements, design details, and hardware are described.

Hacker, R.↗

Effect of confinement in small space flight size cages on insulin sensitivity of exercise-trained rats

The effect of confinement in small cages (simulating the size to be used in future space Shuttle missions) on insulin sensitivity was studied in rats having an increased insulin sensitivity due to exercise training prior to confinement. Oral glucose tolerance tests (OGTT) were given to both control and exercise-trained rats before and after placement in the small cages for 7 days. The insulin resistance was assessed by the product of the area of the insulin and glucose curves of the OGTT (IG index). Results show that the values obtained before confinement were one-half as high in exercise-trained rats as those in control rats, reflecting an increased sensitivity to insulin with exercise training. After 7 days confinement, the IG index was found to be not significantly different from initial values for both control and exercise-trained rats. These findings suggest that increased insulin sensitivity in exercise-trained rats persists 7 days after cessation of running activity. The data also indicate that exercise training, before flight, may be beneficial in minimizing the loss of insulin sensitivity expected with decreased use of gravity dependent muscles during exposure to hypogravity in space flight.

Mondon, C. E.↗

Cepstral Analysis Detects Ball-Cage Wear

Report discusses application of cepstral analysis to diagnosis of wear in ball-bearing cages in rotating machinery. Ball-cage vibrations and changes in vibrations symptomatic of wear is detected earlier in test than by more conventional methods based on strain-gauge measurements. Particularly useful in diagnoses of gearboxes and rolling-element bearing.

Weese, Gary E.↗

Ball-Pass Cage-Modulation Detector

Ball-pass cage-modulation detector puts out signal useful in detecting incipient failure of bearing in rotating machine. Part of system of electronic equipment measuring various components of vibrations in such bearings. Bearing sensor - strain gauge or deflectometer on bearing housing - measures deflections of housing as balls pass by. Output of sensor filtered to extract ball-pass cage modulation, indicative of wear in bearing.

Randall, Richard L.↗

Faraday Cage Protects Against Lightning

Faraday cage protects electronic and electronically actuated equipment from lightning. Follows standard lightning-protection principles. Whether lightning strikes cage or cables running to equipment, current canceled or minimized in equipment and discharged into ground. Applicable to protection of scientific instruments, computers, radio transmitters and receivers, and power-switching equipment.

Jafferis, W.↗

Investigation of Wear and Friction Properties Under Sliding Conditions of Some Materials Suitable for Cages of Rolling-Contact Bearings

An investigation of wear and friction properties of a number of materials sliding against SAE 52100 steel was conducted. These materials included brass, bronze, beryllium copper, monel, nichrome v, 24s-t aluminum, nodular iron, and gray cast iron. The metals investigated may be useful as possible cage (separator or retainer) materials for rolling-contact bearings of high-speed turbine engines. The ability of materials to form surface films that prevent welding is a most important factor in both dry friction and boundary lubrication. On the basis of wear and resistance to welding only, the cast irons were the most promising materials investigated; they showed the least wear and the least tendency to surface failure when run dry, and when boundary lubricated they showed the highest load capacity. On the basis of mechanical properties, nodular iron is superior to gray cast iron. Bronze had the lowest friction coefficient under dry sliding conditions. The results with brass, beryllium copper, and aluminum were poor and these materials do not appear, with regard to friction and wear, to be suitable for cages.

Johnson, Robert L↗