High Current Density Cables for Simpler HTS Magnets in Fusion Energy Systems

High current density cables are needed for the engineering design of potentially low cost, simpler geometry high temperature superconducting (HTS) magnets in the promising magnetic configurations as a fusion pilot plant (FPP) option. Significant technology maturation efforts are underway by privately funded startups with the goal to demonstrate mature HTS magnet technology. Test results, however, indicate critical engineering issues remain to be addressed to meet performance goals, and demonstrate HTS coil operation repeatability and reliability. To this end, exploring and enabling multiple viable conductor and cable options is vital. Partnering with a private fusion startup and manufacturers of superconducting strands and cables, Princeton Plasma Physics Laboratory (PPPL) is exploring and seeking to de-risk the aggressive high field approach presently targeted by others. Our main objective is to develop, test and calibrate novel high current density cables for a broad deployment of affordable and reliable coils using Bi-2212 conductors. If successful, such a project will provide technical feasibility for promising FPP configurations including spherical tokamaks (ST) and compact stellarators. Here, we aim at the state-of-the-art Bi-2212 cable technologies toward a current density of 100 A/mm 2 at 16 T and 4.2 K–10 K operation for low cost, simpler geometry toroidal field (TF) coils for compact stellarators developed by fusion startup companies on a timeline consistent with the FPP initiatives and beyond.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Properties of Cables with Meandering Wires through a Multipole-based Cable Braid Electromagnetic Penetration Model

In this paper, we employ our first principles multipole-based cable braid electromagnetic penetration model to evaluate the transfer inductance of cables exhibiting meandering wires. We concentrate on a cable structure with two wires, and consider the dependence on the transfer inductance as a function of braid angle and amplitude of the meandering. We compare the results from the first principles model to analytical estimations, confirming the accuracy and correctness of our model. In turn, this makes the multipole-based model readily available for the modeling of realistic cable geometries by accounting for the full dependence on the actual cable geometry.

36 MATERIALS SCIENCE↗

AC losses of Roebel and CORC ® cables at higher AC magnetic fields and ramp rates

We have measured ReBCO coated conductor-based conductor on round core (CORC ® ) and Roebel cables at 77 K in a spinning magnet calorimeter, which subjected the tapes in the samples to a radial magnetic field of 566 mT (peak) at frequencies up to 120 Hz (272 T s -1 , cyclic average) with an approximately sinusoidal waveform. The samples were oriented such that the field applied to the tapes within the cables was entirely radial, simplifying subsequent analysis. An expression for loss which included hysteretic, flux creep and eddy current losses was fit to both the CORC ® and the Roebel cables. This expression allowed easy comparison of the relative influence of eddy currents and flux creep (or power-law behavior) effects. The loss of both the CORC ® and Roebel cables measured here were seen to be essentially the sum of the hysteretic loss, flux creep effects, and the normal metal eddy current losses of the individual tapes. The losses of these cables were measured at high B × d B /d t with no coupling current loss observed under the present preparation conditions. The influence of flux creep effects on loss were not negligible. The losses of the CORC ® cable per meter of tape were seen to be reduced from the case of a flat tape because of the helical geometry of the tapes.

Physics↗

Berkeley Lab Finite Element Framework (BELFEM) v0.1

The software program, referred to as BELFEM, is a specialized finite element code designed for the magnetodynamic modeling of high-temperature superconducting (HTS) tapes. It incorporates novel mixed finite element formulations, particularly the h-ϕ-formulation with thin-shell simplification, to efficiently simulate larger geometries. This methodology is extremely promising for predicting the electrodynamic performance of HTS tapes used in superconducting cables and magnets, offering the benefit of reduced computational cost. Compared to similar technologies like COMSOL Multiphysics and GetDP, BELFEM's performance benchmarking indicates superior efficiency in its thin-shell implementation. In the future, it will also support features like thermal coupling and inter-tape current sharing, enhancing its utility in research and development, particularly in nuclear fusion applications. The intent is to develop BELFEM as a robust and efficient tool for the HTS community, contributing to the analysis and design of superconducting cables and magnets.

Messe, Christian↗

Acoustic diagnostic system and method for superconducting devices operating in gas or liquid

A novel system and method for detecting a quench of a superconducting conductor and detecting abnormal behavior of a superconducting conductor using acoustic sensor technology in the coolant of a superconducting cable and/or magnet is disclosed. This system and method is not only limited to use for superconductors, but also may be used for any device disposed in liquid and gas. Acoustic sensors are installed along a coolant space of a superconducting conductor and monitor coolant conditions. By monitoring acoustic changes, temperature changes or coolant flow disruption can be detected very quickly by an acoustic sensor array. By disposition of the acoustic sensor array in a coolant flow channel, the acoustic sensor system can quickly detect a local condition, such as the thermal status (temperature) of a superconducting cable and magnet with precise spatial resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance of low-loss demountable joints between CORC ® cable-in-conduit-conductors at magnetic fields up to 8 T developed for fusion magnets

Abstract High-temperature superconductors (HTS) are promising candidates for use in the high-field magnets needed in particle accelerators and fusion reactors. HTS conductor on round core (CORC ® ) cables and wires wound from ReBa 2 Cu 3 O 7- x (REBCO) coated tapes are being developed for use in high-field magnet applications including fusion magnets operating at currents beyond 80 kA, requiring them to be bundled into cable-in-conduit conductor (CICC) configurations. The use of HTS cables enable demountable superconducting fusion magnets that would allow easier access to the fusion machine for maintenance and parts replacement. Such demountable magnets require practical, low-resistance joints, capable of injecting current uniformly into the many REBCO tapes that make up different cable designs. Optimization steps on CORC ® cables have resulted in high-current terminations and joints with a joint resistance measured between a pair of 30-tape CORC ® cables of 51 nΩ at 76 K and 1.9 nΩ at 4 K. Demountable joints between CICCs consisting of six CORC ® cables arranged in flat and round configurations were also tested and compared to joints between low-temperature superconducting (LTS) CICCs consisting of NbTi Rutherford cables. Samples were paired into two configurations (LTS-to-LTS and HTS-to-HTS) with a demountable joint between them that were each tested in series with currents up to 10 000 A in an applied background magnetic field of up to 8 T. The total loop resistance of the HTS-to-HTS sample, including their terminations and joint, was about 4 nΩ at 4 K in self-field with the resistance of the copper pressed joint being less than 1 nΩ. At 8 T, the total loop resistance increased to 6.9 nΩ with the pressed joint contributing 1.4 nΩ. These initial tests prove the feasibility of producing remountable (dry) joints with low resistance between superconducting magnet windings in future compact fusion machines.

Physics↗

Lambda Plate Seal for HFVMTF Anticryostat

Fermilab is currently designing a High Field Vertical Magnet Test Facility in order to test superconducting cables and magnets. The goal of this project was to analyze the thermal performance of three different seal designs and provide recommendations for the HFVMTF.

Gasior, Brett↗

Cable-splice detector

Detector has possible uses in aerial cable-car systems, equipment handling in mines, boreholes, and undersea operations, and other applications where moving steel cable must be measured, monitored, or controlled. Detector consists of Hall-effect magnetic sensor located close to cable. Magnetic markings on cable are converted to electrical signals. Signals are filtered, amplified, and can actuate alarm.

Lee, R. D.↗

Test of Harmonic Coil Accuracy Using a Multi Vertex Probe

Magnets are integral components of particle accelerators, with different multipoles used to perform various beam conditioning functions, like steering and focusing. Testing accelerator magnets to ensure compliance with specification is a crucial step of fabrication. One of the most popular techniques for verifying magnetic field strength and integrity is the harmonic coil probe. Harmonic coil probes are comprised of passive loops that are rotated around the aperture of a magnet and are used to measure magnetic flux. Oftentimes the measurements of the harmonic coil probe are affected by transverse vibrations along the axis of rotation and torsional vibrations of the position closure sensor, both causing spurious harmonics. To make matters challenging, it is difficult to distinguish between the real harmonics of the magnet and the spurious harmonics during analysis. This research explores the use of a novel configuration of harmonic coil probe, Multi-Vertex Probe (MVP), to address multiple factors that affect the accuracy and repeatability of harmonic coil probe measurement. Most of the results are based on simulation data, in which artificial torsional distortions are introduced and removed with the proposed processing method. In addition to implementing torsional vibration removal in simulation, laboratory analysis regarding the source of vibrations was performed using a pre-fabricated MVP. More specifically, various mechanical conditions were used to explore the standard deviation of main harmonic’s flux amplitude. The conditions included: coupling type (rigid or soft), rotation speed, probe starting position within magnetic field, and cabling location inside the magnetic field. Along with this, the MVP’s measured noise floor in and outside a magnetic field was quantified.

Lofquist, Claire [Northern Illinois U.]↗

Conceptual Design of a HTS Dipole Insert Based on Bi2212 Rutherford Cable

The U.S. Magnet Development Program (US-MDP) is aimed at developing high-field accelerator magnets with magnetic fields beyond the limits of Nb 3 Sn technology. Recent progress with composite wires and Rutherford cables based on the first generation high-temperature superconductor Bi 2 Sr 2 CaCu 2 O 8-x (Bi2212) allows considering them for this purpose. However, Bi2212 wires and cables are sensitive to transverse stresses and strains, which are large in high-field accelerator magnets. This requires magnet designs with stress management concepts to control azimuthal and radial strains in the coil windings and prevent the degradation of the current carrying capability of Bi2212 conductor or even its permanent damage. This paper describes a novel stress management approach, which was developed at Fermilab for high-field large-aperture Nb 3 Sn accelerator magnets, and is now being applied to high-field dipole inserts based on Bi2212 Rutherford cables. The insert conceptual design and main parameters, including the superconducting wire and cable, as well as the coil stress management structure, key technological steps and approaches, test configurations and their target parameters, are presented and discussed.

43 PARTICLE ACCELERATORS↗

Flux Creep in a Bi-2212 Rutherford Cable for Particle Accelerator Applications

Bi-2212 superconducting cables are being considered for use in the high field magnets needed for the next generation of particle accelerators. Magnetization in these cables and the decay of that magnetization lead to field error and field-error drift, respectively, which need to be compensated. To study this, a segment of the winding pack was extracted from a racetrack coil made from Bi-2212 Rutherford cable. Using a Hall probe measurement technique, we measured the response of the cable's magnetization and its magnetization decay to changes in the applied magnetic field. The effect of adjustments to the cycling of the magnetic field was studied, intended to simulate the preinjection cycles of an accelerator magnet. Three M vs. H loops were constructed by sweeping the magnetic field applied to the sample from 0 to 2.5 T, then to a preinjection field 'x' (where x = 0, 0.25, 0.75 T), and finally up to 1 T. The applied field was then held at 1 T for 1500 s, and the magnetization decay was measured. Finally, the decay was found to vary from 8% to 14% after 1500 s, depending on the preinjection field cycle.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and Construction of a Superconducting “Direct Wind” R&D Magnet for the EIC Interaction Region

Brookhaven National Laboratory (BNL) was chosen to host the international Electron-Ion Collider (EIC), which will collide high energy and highly polarized hadron and electron beams with a center of mass energy up to 140 GeV. The Interaction Region (IR) [1] requires several large aperture, relatively high field superconducting dipole and quadrupole magnets, some of which are very closely spaced.\r\nA value engineering effort is underway as part of the EIC Project to construct and test a Direct Wind magnet [2] (coil comprised of NbTi conductor deposited directly onto a support tube, in this instance tapered, and secured mechanically against Lorentz forces afterwards) to replace two Rutherford cable collared magnets. This magnet exceeds the combination of aperture, number of coil \r\nlayers, and magnetic field, as compared to existing accelerator and R&D Direct Wind magnets to date. Furthermore, construction has been completed using a newly commissioned winding machine, upgraded in anticipation of the upcoming EIC production coil fabrication. Design, analysis, construction issues, lessons learned and accomplishments to date shall be discussed, including the \r\nachieved corrections to multipoles made to successive coil layers based on warm magnetic measurements of preceding layers.

43 PARTICLE ACCELERATORS↗

Ultrasonic waveguide reflectometry for quench detection (CRADA Final Report)

Early detection of thermal runaway (quench) is critical for safely operating high-temperature superconductor (HTS) magnets. Voltage-based techniques provide late detection of quenching in HTS, which can lead to magnet burnout and system damage. Various non-voltage quench-detection approaches are therefore investigated nowadays that are based on magnetic, acoustic, and optical sensing. LBNL has been actively developing the quench detection principle based on diffuse ultrasonic wave propagation since 2017 and has demonstrated the approach's viability with several peer-reviewed publications and a patent application. Over the last decade, Etegent, LBNL partner for this proposal and effort, has been developing a sensing technology that utilizes the propagation of stress waves through the solid metallic and nonmetallic waveguides (WG). The method is based on the dependence of materials' elastic properties and the speed of sound on temperature. Compared with optical analog, acoustic WG operates at much lower frequencies, eliminating the need for expensive, complex, highly sensitive receivers and data processing. Etegent proved this technology in many harsh environments, mainly concentrated high-temperature measurements. The initial contact between LBNL and Etegent started in 2020, aiming at combining our knowledge and effort toward developing a viable ultrasound-based quench detection technique for use with HTS magnets. A preliminary study conducted jointly in 2022 found no principle restrictions for expanding the WG technology toward cryogenic temperature operation. The present CRADA work aimed at designing, building, and testing ultrasonic waveguide temperature sensors at relevant cryogenic conditions, and demonstrating this technology's applicability to detecting heating and quenching in High Temperature Superconductor (HTS)-based cables and magnets. The technical objectives of the project included: (1) Design and fabricate ultrasonic WG sensors suitable for cryogenic operation, (2) Test ultrasonic WGs under cryogenic conditions, (3) Determining a suitable way of insulating WGs to prevent ultrasonic leakage while maintaining good thermal contact with the surrounding medium, (4) WG integration and cryogenic test with HTS conductors and HTS magnets, and (5) Design and basic prototyping of a standalone WG-based quench detection system. This project adds value to the present LBNL magnet diagnostics portfolio and enables a breakthrough in addressing the HTS magnet quench detection challenge.

47 OTHER INSTRUMENTATION↗

Marshall Space Flight Center head development program

This report summarizes the results of the candidate head evaluation for the new long-life magnetic head per the SOW of Contract No. NAS8-39407, MSFC Head Development Program. The original program plans were to test a candidate head, fabricate a new head, then qualify the new head. These activities were scheduled to be carried out between March 1993 and March 1994. The program was halted after the evaluation of the candidate head by NAS8-39407 Amendment No. 4. MSFC has provided and authorized the use the MARS-2000 SRB QUAL Recorder PN 10400-0677-801 - Serial Number 200004 (Datatape PN 591000 - Serial Number 1004), Reproduce Amplifier Module (RAM) Datatape PN 533040 - Serial Number 2006, associated cables, and magnetic tape on special SRB/DFI tapered reels to Datatape for this program. All the testing that has been done for the candidate head evaluation was done at Datatape's facility in Pasadena,CA. The testing was performed in a Class 100,000 particle counts clean room at ambient temperature, except for the thermal testing which was conducted in a different area at Datatape. The Performance Verification Test Procedure PVT-11004-4 (PVT) and Acceptance Test Procedure ATP-11004-09 (ATP) procedures were used when tests were conducted on the recorder.

Harrer, Jim↗

AC loss and contact resistance in REBCO CORC ® , Roebel, and stacked tape cables

Abstract Many high-temperature superconductor (HTS) applications require superconducting cables with high currents while operating in an alternating magnetic field. HTS cables should be composed of numerous superconducting tapes to achieve the required current capacity. Alternating current and magnetic fields cause AC losses in such cables and can provoke conductor instability. AC losses and contact resistances were measured of several cable designs based on commercially available REBCO tapes at the University of Twente. The AC loss was measured under identical conditions for eight REBCO conductors manufactured according to three types of cabling methods—CORC ® (Conductor on Round Core), Roebel, and stacked tape, including a full-size REBCO CICC (cable in conduit conductor). The measurements were done at T = 4.2 K without transport current in a sinusoidal AC magnetic field of 0.4 T amplitude and frequencies from 5 to 55 mHz. The AC loss was measured simultaneously by calibrated gas flow calorimeter utilizing the helium boil-off method and by the magnetization method using pick-up coils. Also, the AC loss of two CORC® conductors and a Roebel cable was measured at 77 K. Each conductor was measured with and without background field of 1 T. The measured AC coupling loss in the CORC ® and Roebel conductors is negligible at 4.2 K for the applied conditions while at 77 K coupling loss was observed for all conductors. The absence of coupling loss at 4.2 K can be explained by shielding of the conductor interior; this is confirmed with measurement and calculation of the penetration field of CORC ® and Roebel cables. The inter-tape contact resistance was measured for CORC ® and stacked tape samples at 4.2 and 77 K. It was demonstrated that a short heat treatment of CORC ® conductor with solder-coated tapes activates tape-to-tape soldering and decreases the contact resistance. The reduction of contact resistance by two orders in magnitude to tens of nΩm is comparable with the interstrand contact resistance in ITER Nb 3 Sn type conductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗