Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “broad bandwidth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Far-infrared emission from H II regions. II - Multicolor photometry of selected sources and 2.2 min resolution maps of M42 and NGC 2024

Medium- and broad-bandwidth photometric measurements have been made of seven compact H II regions at wavelengths between 30 and 650 microns. The results are consistent with the hypothesis that the far-infrared flux is continuum radiation from dust grains. Color temperatures range from 33 to 85 K. For most of the sources, the infrared flux is low enough so that the dust could conceivably be mixed with the ionized gas. In at least one case, however, the far-infrared spectrum and luminosity of the source cannot be reconciled with reasonable grain models unless the far-infrared flux comes from a shell surrounding the H II region. M42 (Orion) and NGC 2024 (Orion B) have been mapped at 90 microns with a resolution (half-power beam diameter) of 2.2 min. Although the peak far-infrared brightness in M42 occurs at the position of the Kleinmann-Low infrared nebula, most of the flux originates in a more extended (about 6 x 8 min) source. The energy for the diffuse component could be supplied by the stars in the Trapezium cluster. However, the single early-type star visible in NGC 2024 is not luminous enough to account for either the infrared flux or the observed free-free flux.

Harper, D. A.↗

Satellites using the 30/20 GHz band

A review of the future options open to satellite system planners focuses attention on the use of the 30/20 GHz band. Very broad bandwidths available, coupled with a primary allocation for fixed satellite service, make the band very attractive. NASA, in concert with the system and service supplier industries, is planning a research and development program aimed at flight demonstration of 30/20 satellite systems which it is hoped will lead to operational system use in the early 1990's. The communication system concepts and the spacecraft systems necessary to support these for operational use in 1990 and beyond are discussed.

Sivo, J. N.↗

Single-pulse broad-band rotational CARS thermometry of cold N2 gas

Coherent anti Stokes Raman scattering (CARS) from the pure rotational Raman lines of N2 was employed to measure the instantaneous (10 nsec) rotational temperature of the gas at room temperature and below. An entire rotational CARS spectrum was generated by a single laser pulse using a broad bandwidth dye laser and was recorded on an optical multichannel analyzer. A best fit temperature obtained for individual experimental spectra by comparison with calculated spectra. Good agreement between CARS temperatures and thermocouple temperatures was observed.

Chang, R. K.↗

The cosmic X-ray background

The cosmic X-ray experiment performed with the A2 instrument on HEAO-1 was especially developed to make systematics-free measurements of the extragalactic X-ray sky and has yielded the broadband spectral characteristics for two extreme aspects of this radiation. For the apparently isotropic radiation of cosmological origin that dominates the extragalactic X-ray flux, the spectrum over the energy band of maximum intensity is remarkably well described by a thermal model with a temperature of a half-billion degrees. At the other extreme, broadband observations of individual extragalactic X-ray sources with HEAO-1 are restricted to objects within the present epoch. These X-ray sources include a large sample of active galaxies studied in some detail over a broad bandwidth for the first time. Details of the cosmic X-ray background at these two extremes are reviewed, and some models describing X-ray emission mechanisms are discussed.

Boldt, E.↗

Rotational CARS application to simultaneous and multiple-point temperature and concentration determination in a turbulent flow

Coherent anti-Stokes Raman scattering (CARS) from the pure rotational Raman lines of N2 is employed to measure the instantaneous (approximately 10 ns) rotational temperature of N2 gas at room temperature and below with good spatial resolution (0.2 x 0.2 x 3.0 cu mm). A broad bandwidth dye laser is used to obtain the entire rotational spectrum from a single laser pulse; the CARS signal is then dispersed by a spectrograph and recorded on an optical multichannel analyzer. A best fit temperature is found in several seconds with the aid of a computer for each experimental spectrum by a least squares comparison with calculated spectra. The model used to calculate the theoretical spectra incorporates the temperature and pressure dependence of the pressure-broadened rotational Raman lines, includes the nonresonant background susceptibility, and assumes that the pump laser has a finite linewidth. Temperatures are fit to experimental spectra recorded over the temperature range of 135 to 296 K, and over the pressure range of .13 to 15.3 atm.

Snow, J. B.↗

Rotational cars application to simultaneous and multiple-point temperature and concentration determination in a turbulent flow

Coherent Anti-stokes Raman Scattering (CARS) from the pure rotational Raman lines of N2 is employed to measure the instantaneous rotational temperature of N2 gas at room temperature and below with good spatial resolution. A broad-bandwidth dye laser is used to obtain the entire rotational spectrum from a signal laser pulse; the CARS signal is then dispersed by a spectrograph and recorded on an optical multichannel analyzer. A best-fit temperature is found in several seconds with the aid of a computer for each experimental spectrum by a least squares comparison with calculated spectra. The model used to calculate the theoretical spectra incorporates the temperature and pressure dependence of the pressure-broadened rotational Raman lines, includes the nonresonant background susceptibility, and assumes that the pump laser has a finite linewidth. Temperatures are fit to experimental spectra recorded over the temperature range of 135 to 296K, and over the pressure range of 0.13 to 15.3 atm. In addition to the spatially resolved single point work, we have used multipoint CARS to obtain information from many spatially resolved volume elements along a cylindrical line (0.1 x 0.1 x 2.0 mm). We also obtained qualitative information on the instantaneous species concentration and temperature at 20 spatially resolved volume elements (0.1 x 0.1 x 0.1 mm) along a line.

Snow, J. B.↗

A large area imaging gas scintillation proportional counter for use in X-ray astronomy

A large area (200 sq cm), broad bandwidth (0.1-70 keV), imaging gas scintillation proportional counter (IGSPC) has been constructed for use in X-ray astronomy. The IGSPC consists of a high pressure xenon gas scintillation proportional counter (GSPC) coupled to a multi-wire proportional counter (MWPC) via a calcium fluoride window. THe MWPC, filled with a mixture of argon, methane, and tetrakis (dimethylamino) ethylene, detects the UV photons emitted by the xenon gas in the GSPC. The detector has a measured energy resolution of 8.0 percent (FWHM) and 4.3 percent (FWHM) at 5.9 keV and 22.1 keV, respectively. The predicted spatial resolution of the detector is less than 1 mm (FWHM) between 3-22 keV and 37-60 keV. A method to determine the three-dimensional location of detected X-rays is described. In addition, a combination of discrimination schemes designed to reduce the non-X-ray background in the IGSPC by more than two orders of magnitude is discussed.

Ku, W. H.-M.↗

Interstellar absorption features toward the compact infrared source W33A

A high-resolution (lambda/Delta lambda of approximately 2000) broad-bandwidth (3.3-5.0 microns) spectrum of the compact infrared source W33A is presented. Four absorption features are associated with compositionally distinct components in the interstellar medium: solid-phase C3, CN, or CH3OH at 4.9 microns, solid-phase CO and either solid or gaseous CH3NC near 4.6 microns and the well-known dirty ice feature near 3 microns. The analysis of this spectrum supports chemically complex models of grain mantle evolution in cold, quiescent molecular clouds.

Larson, H. P.↗

The sources of Uranus' dominant nightside radio emissions

The broad-bandwidth radio emission detected by Voyager 2 over the nightside of Uranus is examined. It is concluded that the source location of the smooth component is consistent with emission originating near the electron gyrofrequency from a small set of field lines whose foot points lie near the Uranomagnetic southern (dark) pole. The source centroid is at L = 11.5, and extends in latitude between about L = 8 and L = 25. This deduced source region is primarily on closed field lines that pass through the outer radiation belt and have their opposite foot points near the Uranomagnetic northern pole (near the present epoch terminator). The source location of the bursty component is less well defined but is consistent with the set of open field lines which map down to the region surrounding the planet's south magnetic dipole tip.

Kaiser, M. L.↗

A fine resolution multifrequency polarimetric FM radar

A fine resolution polarimetric FM SAR was developed for optimization of polarimetric SARs and interpretation of SAR data via controlled experiments with surface-base sensors. The system is designed for collecting polarimetric data at 5.3 and 10 GHz over incidence angles from 0 to 60 deg. Features of the system include broad bandwidth to obtain fine range resolution, phase stabilization and linearization loop circuitry, and digital signal processing capability. The system is used in a research program to collect polarimetric backscatter data from artificial sea ice research and design trade-offs, laboratory and field evaluation, as well as results from experiments on artificial sea ice are presented.

Bredow, J.↗

A search for p-mode oscillations of Jupiter - Serendipitous observations of nonacoustic thermal wave structure

Frequencies for the p-mode oscillations of Jupiter have been determined, and infrared brightness temperature fluctuations are used to search for the modes. Measurements of the infrared intensity of the Jovian disk were obtained in a broad bandwidth using a 20-element linear array. No p-mode oscillations were observed at the 0.07-K level in the 8-13-micron brightness temperature. The results suggest that Jovian p modes are not likely to have observable amplitudes. A prominent nonacoustic wave-like structure in the 8-13-micron brightness temperature is found both at 20 deg N and at the equator.

Deming, Drake↗

Channelized coplanar waveguide pin-diode switches

Three different types of p-i-n diode, reflective CPW switches are presented. The first two switches are the series and the shunt mounted diode switches. Each has achieved greater than 15 dB of isolation over a broad bandwidth. The third switch is a narrow band, high isolation switched filter which has achieved 19 dB of isolation. Equivalent circuits and measured performance for each switch is presented.

Ponchak, G. E.↗

Slot antenna SIS mixers for submillimeter wavelengths

We are developing improved versions of a slot antenna SIS mixer which we have previously described. The initial work demonstrated a double sideband noise temperature of 420 K for a 500 GHz quasi-optical SIS mixer employing a twin-slot antenna on a quartz dielectric substrate. A quartz hyperhemispherical lens is used to focus the incoming radiation onto the twin-slot antenna. The advantages of a twin-slot antenna include a low impedance (35 omega) and a clean, symmetric beam pattern into the dielectric with a 70 percent efficiency. In our original mixer, the radiation was coupled from the two slot antennas onto superconducting microstrip lines which fed the SIS junction. By performing an impedance transformation using tapered lines and by feeding the radiation from the two slots to the junction in parallel, the effective (real) impedance seen by the junction was reduced to just 4 omega. This very low impedance allowed a junction area of 2.3 sq micron to be used at 500 GHz, which was manufactured using optical lithography. However, no attempt was made to tune out the junction capacitance. We estimate that this capacitance reduces the impedance coupling efficiency to eta(sub Z) approx. equals 0.23, for our junction with omega R(sub N) C = 5.3 at 500 GHz. The recent development of techniques using electron-beam lithography to manufacture junctions with very small areas (approx. equals 0.1 sq microns) now allows considerably more flexibility in the design of SIS mixer circuits. We have redesigned the slot-antenna mixer to take advantage of this possibility. In particular, we have included a novel circuit which allows the junction capacitance to be tune out over a broad bandwidth. For instance, mixers designed for 800 GHz using NbN/MgO/NbN junctions with realistic parameters achieve a 3 dB impedance bandwidth of nearly 400 GHz. Furthermore, our circuit uses only short lengths of microstrip and should be less sensitive to RF losses than other designs. The improved impedance match should give a large reduction in noise temperature as compared to our previous mixer. The new devices are currently under fabrication. Further details of the design and any available experimental results are discussed.

Zmuidzinas, Jonas↗

Mineralogic variations in fluvial sediments contaminated by mine tailings as determined from AVIRIS data, Coeur D'Alene River Valley, Idaho

The success of imaging spectrometry in mineralogic mapping of natural terrains indicates that the technology can also be used to assess the environmental impact of human activities in certain instances. Specifically, this paper describes an investigation into the use of data from the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) for mapping the spread of, and assessing changes in, the mineralogic character of tailings from a major silver and base metal mining district. The area under investigation is the Coeur d'Alene River Valley in northern Idaho. Mining has been going on in and around the towns of Kellogg and Wallace, Idaho since the 1880's. In the Kellogg-Smelterville Flats area, west of Kellogg, mine tailings were piled alongside the South Fork of the Coeur d'Alene River. Until the construction of tailings ponds in 1968 much of these waste materials were washed directly into the South Fork. The Kellogg-Smelterville area was declared an Environmental Protection Agency (EPA) Superfund site in 1983 and remediation efforts are currently underway. Recent studies have demonstrated that sediments in the Coeur d'Alene River and in the northern part of Lake Coeur d'Alene, into which the river flows, are highly enriched in Ag, Cu, Pb, Zn, Cd, Hg, As, and Sb. These trace metals have become aggregated in iron oxide and oxyhydroxide minerals and/or mineraloids. Reflectance spectra of iron-rich tailing materials are shown. Also shown are spectra of hematite and goethite. The broad bandwidth and long band center (near 1 micron) of the Fe(3+) crystal-field band of the iron-rich sediment samples combined with the lack of features on the Fe(3+) -O(2-) charge transfer absorption edge indicates that the ferric oxide and/or oxyhydroxide in these sediments is poorly crystalline to amorphous in character. Similar features are seen in poorly crystalline basaltic weathering products (e.g., palagonites). The problem of mapping and analyzing the downriver occurrences of iron rich tailings in the Coeur d'Alene (CDA) River Valley using remotely sensed data is complicated by the full vegetation cover present in the area. Because exposures of rock and soil were sparse, the data processing techniques used in this study were sensitive to detecting materials at subpixel scales. The methods used included spectral mixture analysis and a constrained energy minimization technique.

Farrand, W. H.↗

The Development of Si and SiGe Technologies for Microwave and Millimeter-Wave Integrated Circuits

Historically, microwave technology was developed by military and space agencies from around the world to satisfy their unique radar, communication, and science applications. Throughout this development phase, the sole goal was to improve the performance of the microwave circuits and components comprising the systems. For example, power amplifiers with output powers of several watts over broad bandwidths, low noise amplifiers with noise figures as low as 3 dB at 94 GHz, stable oscillators with low noise characteristics and high output power, and electronically steerable antennas were required. In addition, the reliability of the systems had to be increased because of the high monetary and human cost if a failure occurred. To achieve these goals, industry, academia and the government agencies supporting them chose to develop technologies with the greatest possibility of surpassing the state of the art performance. Thus, Si, which was already widely used for digital circuits but had material characteristics that were perceived to limit its high frequency performance, was bypassed for a progression of devices starting with GaAs Metal Semiconductor Field Effect Transistors (MESFETs) and ending with InP Pseudomorphic High Electron Mobility Transistors (PHEMTs). For each new material or device structure, the electron mobility increased, and therefore, the high frequency characteristics of the device were improved. In addition, ultra small geometry lithographic processes were developed to reduce the gate length to 0.1 pm which further increases the cutoff frequency. The resulting devices had excellent performance through the millimeter-wave spectrum.

Ponchak, George E.↗

Sideband-Separating, Millimeter-Wave Heterodyne Receiver

Researchers have demonstrated a submillimeter-wave spectrometer that combines extremely broad bandwidth with extremely high sensitivity and spectral resolution to enable future spacecraft to measure the composition of the Earth s troposphere in three dimensions many times per day at spatial resolutions as high as a few kilometers. Microwave limb sounding is a proven remote-sensing technique that measures thermal emission spectra from molecular gases along limb views of the Earth s atmosphere against a cold space background.

Ward, John S.↗

Digital Spectrometers for Interplanetary Science Missions

A fully digital polyphase spectrometer recently developed by the University of California Berkeley Wireless Research Center in conjunction with the Jet Propulsion Laboratory provides a low mass, power, and cost implementation of a spectrum channelizer for submillimeter spectrometers for future missions to the Inner and Outer Solar System. The digital polyphase filter bank spectrometer (PFB) offers broad bandwidth with high spectral resolution, minimal channel-to-channel overlap, and high out-of-band rejection.

polyphase filter bank spectrometer (PFB)↗

NASA Tech Briefs, June 2012

Topics covered include: iGlobe Interactive Visualization and Analysis of Spatial Data; Broad-Bandwidth FPGA-Based Digital Polyphase Spectrometer; Small Aircraft Data Distribution System; Earth Science Datacasting v2.0; Algorithm for Compressing Time-Series Data; Onboard Science and Applications Algorithm for Hyperspectral Data Reduction; Sampling Technique for Robust Odorant Detection Based on MIT RealNose Data; Security Data Warehouse Application; Integrated Laser Characterization, Data Acquisition, and Command and Control Test System; Radiation-Hard SpaceWire/Gigabit Ethernet-Compatible Transponder; Hardware Implementation of Lossless Adaptive Compression of Data From a Hyperspectral Imager; High-Voltage, Low-Power BNC Feedthrough Terminator; SpaceCube Mini; Dichroic Filter for Separating W-Band and Ka-Band; Active Mirror Predictive and Requirement Verification Software (AMP-ReVS); Navigation/Prop Software Suite; Personal Computer Transport Analysis Program; Pressure Ratio to Thermal Environments; Probabilistic Fatigue Damage Program (FATIG); ASCENT Program; JPL Genesis and Rapid Intensification Processes (GRIP) Portal; Data::Downloader; Fault Tolerance Middleware for a Multi-Core System; DspaceOgreTerrain 3D Terrain Visualization Tool; Trick Simulation Environment 07; Geometric Reasoning for Automated Planning; Water Detection Based on Color Variation; Single-Layer, All-Metal Patch Antenna Element with Wide Bandwidth; Scanning Laser Infrared Molecular Spectrometer (SLIMS); Next-Generation Microshutter Arrays for Large-Format Imaging and Spectroscopy; Detection of Carbon Monoxide Using Polymer-Composite Films with a Porphyrin-Functionalized Polypyrrole; Enhanced-Adhesion Multiwalled Carbon Nanotubes on Titanium Substrates for Stray Light Control; Three-Dimensional Porous Particles Composed of Curved, Two-Dimensional, Nano-Sized Layers for Li-Ion Batteries 23 Ultra-Lightweight; and Ultra-Lightweight Nanocomposite Foams and Sandwich Structures for Space Structure Applications.

Source record↗