A two-wire IC compatible capacitive transducer circuit
Two-wire IC pressure transducer bridge circuit performance features based on circuit analysis
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Two-wire IC pressure transducer bridge circuit performance features based on circuit analysis
Bolometer detector and bridge circuit measure the RF power. A varied bridge reference resistor achieves maximum power transfer allowing the output impedance of the RF source to be determined from the known circuit parameters.
This paper describes a variety of practical application circuits based on the current loop signal conditioning paradigm. Equations defining the circuit response are also provided. The constant current loop is a fundamental signal conditioning circuit concept that can be implemented in a variety of configurations for resistance-based transducers, such as strain gages and resistance temperature detectors. The circuit features signal conditioning outputs which are unaffected by extremely large variations in lead wire resistance, direct current frequency response, and inherent linearity with respect to resistance change. Sensitivity of this circuit is double that of a Wheatstone bridge circuit. Electrical output is zero for resistance change equals zero. The same excitation and output sense wires can serve multiple transducers. More application arrangements are possible with constant current loop signal conditioning than with the Wheatstone bridge.
Several embodiments of RF source resistance measuring devices are disclosed. Common to all embodiments in the feature of the inclusion of at least one variable resistor, and a peak readout meter. In one embodiment, two ganged unloaded potentiometers are employed while another embodiment comprises an automaticnulling RF power bridge circuit with a variable rather than a fixed bridge reference resistance. A third embodiment comprises a calorimeter with a varible rather than a fixed resistor, while in another embodiment attenuator pads with variable resistors are employed.
Short circuits to ground indicated by voltage changes. Current transducer connected in bridge circuit with floating 30-Vdc power supply measures voltage unbalance between positive and negative powerlines and ground. Detection circuit output swings higher or lower than normal balanced condition voltage to signify unbalance toward positive or negative side respectively. Circuit configuration adaptable to monitor 4- to 20-mA current loops often found in industrial controls.
Device allows wind speeds to be measured with less power by alternating hot-wire or hot-film heating periods with measurement periods. System includes reference auxiliary circuits to generate V sub ref and ramp voltage (E sub 3) and reference half of bridge circuit. Circuit permits use of several sensing films with common temperature compensation sensor.
Thermocouple-signal-conditioning circuit acting in conjunction with thermocouple, exhibits electrical behavior of voltage in series with resistance. Combination part of input bridge circuit of controller. Circuit configured for either of two specific applications by selection of alternative resistances and supply voltages. Includes alarm circuit detecting open circuit in thermocouple and provides off-scale output to signal malfunctions.
A current determiner having an output at which representations of input currents are provided having an input conductor for the input current and a current sensor supported on a substrate electrically isolated from one another but with the sensor positioned in the magnetic fields arising about the input conductor due to any input currents. The sensor extends along the substrate in a direction primarily perpendicular to the extent of the input conductor and is formed of at least a pair of thin-film ferromagnetic layers separated by a non-magnetic conductive layer. The sensor can be electrically connected to a electronic circuitry formed in the substrate including a nonlinearity adaptation circuit to provide representations of the input currents of increased accuracy despite nonlinearities in the current sensor, and can include further current sensors in bridge circuits.
A current determiner having an output at which representations of input currents are provided having an input conductor for the input current and a current sensor supported on a substrate electrically isolated from one another but with the sensor positioned in the magnetic fields arising about the input conductor due to any input currents. The sensor extends along the substrate in a direction primarily perpendicular to the extent of the input conductor and is formed of at least a pair of thin-film ferromagnetic layers separated by a non-magnetic conductive layer. The sensor can be electrically connected to electronic circuitry formed in the substrate including a nonlinearity adaptation circuit to provide representations of the input currents of increased accuracy despite nonlinearities in the current sensor, and can include further current sensors in bridge circuits.
The use of a known temperature compensation technique is suggested to reduce the overall temperature sensitivity of a PdCr strain gauge system being developed for turbine engine research. The temperature compensation technique proposed for this application uses a resistance thermometer in an adjacent leg of the strain gauge bridge circuit to cancel the thermally generated resistance change of the strain gauge. Equations for calculating the required compensation resistor values and the sensitivity of the resulting strain gauge bridge to both temperature and strain are presented.
Diode-quad bridge circuit was developed for use with pressure-sensitive capacitive transducers, liquid-level measuring devices, proximity deflection sensors, and inductive displacement sensors. It may also be used as FM discriminator and as universal impedance bridge.
Driving and braking torques controllable. Control circuit operates 7-kW, 45-lb-ft (61-N-m), three-phase, brushless dc motor in both motor and generator modes. In motor modes, energy from power source is pulse-width modulated to motor through modified "H-bridge" circuit, in generator mode, energy from motor is pulse-width modulated into bank of load resistors to provide variable braking torques. Circuit provides high-resolution torque control in both directions over wide range of speeds and torques. Tested successfully at bus voltages up to 200 Vdc and currents up to 45 A.
A circuit for commutating a thyristor (21) by shunting its current for a minimum interval, thereby removing sustaining voltage to said thyristor, then subsequently restoring voltage to said thyristor at a predetermined rate, utilizes a series combination of a commutation electronic switch (22) and an isolated dc voltage supply (23) connected in parallel with the thyristor. The voltage supply is arranged with a polarity that permits the current flowing through the thyristor in one direction to be bypassed through the series combination while the commutation switch is turned on and to reverse bias the thyristor when the commutation switch is fully on. A dv/dt control circuit (24) limits the rate of rise of voltage across the commutation switch (22) as it is turned off in response to a command input signal. The dv/dt control circuit is comprised of a constant current drive (31) and a capacitor (32) connected between the output terminal of the commutation switch and the control input terminal of the commutation switch. The thyristor may be a triac (40) with two commutation switches (42, 43), one for current of each polarity, or with a single commutation switch (55) and a bridge circuit (52-55) for selecting the polarity of the switch (56).
A series-connected buck boost regulator (SCBBR) is an electronic circuit that bucks a power-supply voltage to a lower regulated value or boosts it to a higher regulated value. The concept of the SCBBR is a generalization of the concept of the SCBR, which was reported in "Series-Connected Boost Regulators" (LEW-15918), NASA Tech Briefs, Vol. 23, No. 7 (July 1997), page 42. Relative to prior DC-voltage-regulator concepts, the SCBBR concept can yield significant reductions in weight and increases in power-conversion efficiency in many applications in which input/output voltage ratios are relatively small and isolation is not required, as solar-array regulation or battery charging with DC-bus regulation. Usually, a DC voltage regulator is designed to include a DC-to-DC converter to reduce its power loss, size, and weight. Advances in components, increases in operating frequencies, and improved circuit topologies have led to continual increases in efficiency and/or decreases in the sizes and weights of DC voltage regulators. The primary source of inefficiency in the DC-to-DC converter portion of a voltage regulator is the conduction loss and, especially at high frequencies, the switching loss. Although improved components and topology can reduce the switching loss, the reduction is limited by the fact that the converter generally switches all the power being regulated. Like the SCBR concept, the SCBBR concept involves a circuit configuration in which only a fraction of the power is switched, so that the switching loss is reduced by an amount that is largely independent of the specific components and circuit topology used. In an SCBBR, the amount of power switched by the DC-to-DC converter is only the amount needed to make up the difference between the input and output bus voltage. The remaining majority of the power passes through the converter without being switched. The weight and power loss of a DC-to-DC converter are determined primarily by the amount of power processed. In the SCBBR, the unswitched majority of the power is passed through with very little power loss, and little if any increase in the sizes of the converter components is needed to enable the components to handle the unswitched power. As a result, the power-conversion efficiency of the regulator can be very high, as shown in the example of Figure 1. A basic SCBBR includes a DC-to-DC converter (see Figure 2). The switches and primary winding of a transformer in the converter is connected across the input bus, while the secondary winding and switches are connected in series with the output bus, so that the output voltage is the sum of the input voltage and the secondary voltage of the converter. In the breadboard SCBBR, the input voltage applied to the primary winding is switched by use of metal oxide/semiconductor field-effect transistors (MOSFETs) in a full bridge circuit; the secondary winding is center-tapped, with two MOSFET switches and diode rectifiers connected in opposed series in each leg. The sets of opposed switches and rectifiers are what enable operation in either a boost or a buck mode. In the boost mode, input voltage and current, and the output voltage and current are all positive; that is, the secondary voltage is added to the input voltage and the net output voltage can be regulated at a value equal or greater than the input voltage. In the buck mode, input voltage is still positive and the current still flows in the same direction in the secondary, but the switches are controlled such that some power flows from the secondary to the primary. The voltage across the secondary and the current into the primary are reversed. The result is that the output voltage is lower than the input voltage, and some power is recirculated from the converter secondary back to the input. Quantitatively, the advantage of an SCBBR is a direct function of the regulation range required. If, for example, a regulation range of 20 percent is required for a 500-W supply, th it suffices to design the DC-to-DC converter in the SCBBR for a power rating of only 100 W. The switching loss and size are much smaller than those of a conventional regulator that must be rated for switching of all 500 W. The reduction in size and the increase in efficiency are not directly proportional to switched-power ratio of 5:1 because the additional switches contribute some conduction loss and the input and output filters must be larger than those typically required for a 100-W converter. Nevertheless, the power loss and the size can be much smaller than those of a 500-W converter.
Connector pin consisting of a piezoresistive crystal, retainer spring and a bridge circuit with voltmeter is used to test connector sockets and may be adapted for multiple socket testing.
Sensing device measures directly the density of compressible fluid existing simultaneously in both liquid and gaseous phases. The device is comprised of a capacitor connected as one leg of a bridge circuit, a power source, and an indicator calibrated to indicate density as a direct measurement.
Two ferroelectric bolometer sensing elements measure low rf absolute power at millimeter and submillimeter wavelengths. The sensing elements are mounted in sections of waveguide and connected in series in a standard temperature compensating bridge circuit.
Resistance thermometer incorporating a germanium resistance element with a platinum resistance element in a wheatstone bridge circuit has a linear temperature-resistance coefficient over a range from approximately minus 140 deg C to approximately minus 253 deg C.