Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bridge circuits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Automatic Control of Arc Process for Making Carbon Nanotubes

An automatic-control system has been devised for a process in which carbon nanotubes are produced in an arc between a catalyst-filled carbon anode and a graphite cathode. The control system includes a motor-driven screw that adjusts the distance between the electrodes. The system also includes a bridge circuit that puts out a voltage proportional to the difference between (1) the actual value of potential drop across the arc and (2) a reference value between 38 and 40 V (corresponding to a current of about 100 A) at which the yield of carbon nanotubes is maximized. Utilizing the fact that the potential drop across the arc increases with the interelectrode gap, the output of the bridge circuit is fed to a motor-control circuit that causes the motor to move the anode toward or away from the cathode if the actual potential drop is more or less, respectively, than the reference potential. Thus, the system regulates the interelectrode gap to maintain the optimum potential drop. The system also includes circuitry that records the potential drop across the arc and the relative position of the anode holder as function of time.

Scott, Carl D.↗

A Single-Stage Isolated Resonant SiC DC/AC Inverter for Efficient High-Power Applications

This paper presents a single-stage series-resonant dual active half bridge (SR-DAHB) inverter suitable for high power applications. The topology is an isolated dual half-bridge circuit with an unfolding bridge. A combined phase-shift and frequency modulation technique is utilized to generate AC power output. In high-power applications where the switching devices operate at relatively high current and voltage, the switching loss becomes the major portion of the converter’s total loss as the devices are turned on and off under hard switching condition. The primary merit of the proposed single-stage SR-DAHB inverter with the combined phase-shift and frequency modulation control is to significantly reduce the switching loss so that it is not a function of load current. A precise and comprehensive power loss model is developed for both the SR-DAHB and DAHB to optimize the operation of the inverters. The objective of the optimization is to minimize the inverter total loss while calculating the optimum combination of frequency and phase shift. A 1.5 kV, 50 kW prototype was built to demonstrate the performance of the SRDAHB versus DAHB inverters with the combined phase-shift and frequency modulation control, and validate the theoretical analysis.

Tayebi, S. Milad↗

Wein bridge oscillator circuit

Circuit with minimum number of components provides stable outputs of 2 to 8 volts at frequencies of .001 to 100 kHz. Oscillator exhibits low power consumption, portability, simplicity, and drive capability, it has application as loudspeaker tester and audible alarm, as well as in laboratory and test generators.

Lipoma, P. C.↗

Current loop signal conditioning: Practical applications

This paper describes a variety of practical application circuits based on the current loop signal conditioning paradigm. Equations defining the circuit response are also provided. The constant current loop is a fundamental signal conditioning circuit concept that can be implemented in a variety of configurations for resistance-based transducers, such as strain gages and resistance temperature detectors. The circuit features signal conditioning outputs which are unaffected by extremely large variations in lead wire resistance, direct current frequency response, and inherent linearity with respect to resistance change. Sensitivity of this circuit is double that of a Wheatstone bridge circuit. Electrical output is zero for resistance change equals zero. The same excitation and output sense wires can serve multiple transducers. More application arrangements are possible with constant current loop signal conditioning than with the Wheatstone bridge.

Anderson, Karl F.↗

RF-source resistance meters

Several embodiments of RF source resistance measuring devices are disclosed. Common to all embodiments in the feature of the inclusion of at least one variable resistor, and a peak readout meter. In one embodiment, two ganged unloaded potentiometers are employed while another embodiment comprises an automaticnulling RF power bridge circuit with a variable rather than a fixed bridge reference resistance. A third embodiment comprises a calorimeter with a varible rather than a fixed resistor, while in another embodiment attenuator pads with variable resistors are employed.

Oakley, E. C.↗

Direct-Current Unbalance Detector

Short circuits to ground indicated by voltage changes. Current transducer connected in bridge circuit with floating 30-Vdc power supply measures voltage unbalance between positive and negative powerlines and ground. Detection circuit output swings higher or lower than normal balanced condition voltage to signify unbalance toward positive or negative side respectively. Circuit configuration adaptable to monitor 4- to 20-mA current loops often found in industrial controls.

Wagner, A. P.↗

Low-power anemometer

Device allows wind speeds to be measured with less power by alternating hot-wire or hot-film heating periods with measurement periods. System includes reference auxiliary circuits to generate V sub ref and ramp voltage (E sub 3) and reference half of bridge circuit. Circuit permits use of several sensing films with common temperature compensation sensor.

Gilje, R. I.↗

Thermocouple-Signal-Conditioning Circuit

Thermocouple-signal-conditioning circuit acting in conjunction with thermocouple, exhibits electrical behavior of voltage in series with resistance. Combination part of input bridge circuit of controller. Circuit configured for either of two specific applications by selection of alternative resistances and supply voltages. Includes alarm circuit detecting open circuit in thermocouple and provides off-scale output to signal malfunctions.

Simon, Richard A.↗

Magnetic current sensor

A current determiner having an output at which representations of input currents are provided having an input conductor for the input current and a current sensor supported on a substrate electrically isolated from one another but with the sensor positioned in the magnetic fields arising about the input conductor due to any input currents. The sensor extends along the substrate in a direction primarily perpendicular to the extent of the input conductor and is formed of at least a pair of thin-film ferromagnetic layers separated by a non-magnetic conductive layer. The sensor can be electrically connected to a electronic circuitry formed in the substrate including a nonlinearity adaptation circuit to provide representations of the input currents of increased accuracy despite nonlinearities in the current sensor, and can include further current sensors in bridge circuits.

Black, Jr., William C.↗

Magnetically coupled signal isolator

A current determiner having an output at which representations of input currents are provided having an input conductor for the input current and a current sensor supported on a substrate electrically isolated from one another but with the sensor positioned in the magnetic fields arising about the input conductor due to any input currents. The sensor extends along the substrate in a direction primarily perpendicular to the extent of the input conductor and is formed of at least a pair of thin-film ferromagnetic layers separated by a non-magnetic conductive layer. The sensor can be electrically connected to electronic circuitry formed in the substrate including a nonlinearity adaptation circuit to provide representations of the input currents of increased accuracy despite nonlinearities in the current sensor, and can include further current sensors in bridge circuits.

Black, Jr., William C.↗

The dual element method of strain gauge temperature compensation

The use of a known temperature compensation technique is suggested to reduce the overall temperature sensitivity of a PdCr strain gauge system being developed for turbine engine research. The temperature compensation technique proposed for this application uses a resistance thermometer in an adjacent leg of the strain gauge bridge circuit to cancel the thermally generated resistance change of the strain gauge. Equations for calculating the required compensation resistor values and the sensitivity of the resulting strain gauge bridge to both temperature and strain are presented.

Englund, David R.↗

Diode-quad bridge for reactive transducers and FM discriminators

Diode-quad bridge circuit was developed for use with pressure-sensitive capacitive transducers, liquid-level measuring devices, proximity deflection sensors, and inductive displacement sensors. It may also be used as FM discriminator and as universal impedance bridge.

Harrison, D. R.↗

Controller for a High-Power, Brushless dc Motor

Driving and braking torques controllable. Control circuit operates 7-kW, 45-lb-ft (61-N-m), three-phase, brushless dc motor in both motor and generator modes. In motor modes, energy from power source is pulse-width modulated to motor through modified "H-bridge" circuit, in generator mode, energy from motor is pulse-width modulated into bank of load resistors to provide variable braking torques. Circuit provides high-resolution torque control in both directions over wide range of speeds and torques. Tested successfully at bus voltages up to 200 Vdc and currents up to 45 A.

Fleming, David J.↗

Voltage reapplication rate control for commutation of thyristors

A circuit for commutating a thyristor (21) by shunting its current for a minimum interval, thereby removing sustaining voltage to said thyristor, then subsequently restoring voltage to said thyristor at a predetermined rate, utilizes a series combination of a commutation electronic switch (22) and an isolated dc voltage supply (23) connected in parallel with the thyristor. The voltage supply is arranged with a polarity that permits the current flowing through the thyristor in one direction to be bypassed through the series combination while the commutation switch is turned on and to reverse bias the thyristor when the commutation switch is fully on. A dv/dt control circuit (24) limits the rate of rise of voltage across the commutation switch (22) as it is turned off in response to a command input signal. The dv/dt control circuit is comprised of a constant current drive (31) and a capacitor (32) connected between the output terminal of the commutation switch and the control input terminal of the commutation switch. The thyristor may be a triac (40) with two commutation switches (42, 43), one for current of each polarity, or with a single commutation switch (55) and a bridge circuit (52-55) for selecting the polarity of the switch (56).

Rippel, Wally E.↗

Series-Connected Buck Boost Regulators

A series-connected buck boost regulator (SCBBR) is an electronic circuit that bucks a power-supply voltage to a lower regulated value or boosts it to a higher regulated value. The concept of the SCBBR is a generalization of the concept of the SCBR, which was reported in "Series-Connected Boost Regulators" (LEW-15918), NASA Tech Briefs, Vol. 23, No. 7 (July 1997), page 42. Relative to prior DC-voltage-regulator concepts, the SCBBR concept can yield significant reductions in weight and increases in power-conversion efficiency in many applications in which input/output voltage ratios are relatively small and isolation is not required, as solar-array regulation or battery charging with DC-bus regulation. Usually, a DC voltage regulator is designed to include a DC-to-DC converter to reduce its power loss, size, and weight. Advances in components, increases in operating frequencies, and improved circuit topologies have led to continual increases in efficiency and/or decreases in the sizes and weights of DC voltage regulators. The primary source of inefficiency in the DC-to-DC converter portion of a voltage regulator is the conduction loss and, especially at high frequencies, the switching loss. Although improved components and topology can reduce the switching loss, the reduction is limited by the fact that the converter generally switches all the power being regulated. Like the SCBR concept, the SCBBR concept involves a circuit configuration in which only a fraction of the power is switched, so that the switching loss is reduced by an amount that is largely independent of the specific components and circuit topology used. In an SCBBR, the amount of power switched by the DC-to-DC converter is only the amount needed to make up the difference between the input and output bus voltage. The remaining majority of the power passes through the converter without being switched. The weight and power loss of a DC-to-DC converter are determined primarily by the amount of power processed. In the SCBBR, the unswitched majority of the power is passed through with very little power loss, and little if any increase in the sizes of the converter components is needed to enable the components to handle the unswitched power. As a result, the power-conversion efficiency of the regulator can be very high, as shown in the example of Figure 1. A basic SCBBR includes a DC-to-DC converter (see Figure 2). The switches and primary winding of a transformer in the converter is connected across the input bus, while the secondary winding and switches are connected in series with the output bus, so that the output voltage is the sum of the input voltage and the secondary voltage of the converter. In the breadboard SCBBR, the input voltage applied to the primary winding is switched by use of metal oxide/semiconductor field-effect transistors (MOSFETs) in a full bridge circuit; the secondary winding is center-tapped, with two MOSFET switches and diode rectifiers connected in opposed series in each leg. The sets of opposed switches and rectifiers are what enable operation in either a boost or a buck mode. In the boost mode, input voltage and current, and the output voltage and current are all positive; that is, the secondary voltage is added to the input voltage and the net output voltage can be regulated at a value equal or greater than the input voltage. In the buck mode, input voltage is still positive and the current still flows in the same direction in the secondary, but the switches are controlled such that some power flows from the secondary to the primary. The voltage across the secondary and the current into the primary are reversed. The result is that the output voltage is lower than the input voltage, and some power is recirculated from the converter secondary back to the input. Quantitatively, the advantage of an SCBBR is a direct function of the regulation range required. If, for example, a regulation range of 20 percent is required for a 500-W supply, th it suffices to design the DC-to-DC converter in the SCBBR for a power rating of only 100 W. The switching loss and size are much smaller than those of a conventional regulator that must be rated for switching of all 500 W. The reduction in size and the increase in efficiency are not directly proportional to switched-power ratio of 5:1 because the additional switches contribute some conduction loss and the input and output filters must be larger than those typically required for a 100-W converter. Nevertheless, the power loss and the size can be much smaller than those of a 500-W converter.

Birchenough, Arthur G.↗

Pop-up Langmuir probe diagnostic in the water cooled divertor of Wendelstein 7-X

The design, development, and successful implementation of pop-up Langmuir probes installed in the water-cooled divertor of W7-X are described. The probes are controlled by drive coils (actuators) installed behind the divertor plates. These drive coils make use of the magnetic field in W7-X to move the probe tips into and out of the plasma. The drive coils were installed in the vacuum vessel after extensively testing the durability of the coils and analyzing the criteria for safe operation. The probe design is carefully tailored for each of the 36 probe tips in order to be suitable for the different magnetic field configurations used in W7-X and ensure that the probes do not present leading edges to the magnetic flux tubes. An electronic bridge circuit is used for measurement to compensate for the effects of signal propagation time on the long cable lengths used. The diagnostic is integrated with the segment control of W7-X for automated operation and control of the diagnostic. The evaluation of the results from the plasma operation is presented after accounting for appropriate sheath expansion for negative bias voltage on the probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗