Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bolometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

27 records · Page 2

Validation of 3D MHD simulations of Ne/D 2 mixed shattered pellet injection in JET

Nonlinear 3D magnetohydrodynamic (MHD) modeling of shattered pellet injection (SPI) in JET tokamak plasmas is performed with the JOREK code. The study focuses on the validation of simulation result with respect to experimental observations, addressing in particular figures of merit for the efficiency of the SPI, as a technique to mitigate thermal loads by injecting radiative impurities like neon during the thermal quench (TQ) phase of disruptions. A set of JET pulses with neon/deuterium atomic mixture ratio in the shattered pellet varying from 10% to 100% provides the experimental data to be compared with. Simulations using different models for the ablation of solid fragments and the radiation of neon impurities are considered. Synthetic diagnostics are employed for a direct quantitative comparison with key JET diagnostic systems providing in particular radiation, electron temperature and density, and magnetic measurements. 3D radiation structures from MHD simulations are analyzed to estimate the toroidal asymmetry of radiation, which is difficult to measure in JET due to the presence of only two toroidally displaced multi-channel bolometry systems. JOREK simulations show that, before the TQ, the bulk of the radiation is concentrated in a toroidal region enclosing the radiating fragments that is missed by both multi-channel bolometers, suggesting a possible underestimation of the total radiation by such diagnostic systems in the pre-TQ phase. On the other hand, JOREK predicts that during the TQ the radiation becomes more toroidally symmetric, with positive implications for the heat load to plasma facing components.

JOREK↗

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Enhanced sensitivity to trace 238 U impurity of sapphire via coincidence neutron activation analysis

Sapphire has mechanical and electrical properties that are advantageous for the construction of internal components of radiation detectors such as time projection chambers and bolometers. However, it has proved difficult to assess its 232 Th and 238 U content down to the picogram per gram level. Here, this work reports an experimental verification of a computational study that demonstrates 𝛾⁢𝛾 coincidence counting, coupled with neutron activation analysis (NAA), can reach ppt sensitivities. Combining results from 𝛾⁢𝛾 coincidence counting with those of earlier single-𝛾 counting based NAA shows that a sample of Saint Gobain sapphire has 232 Th and 238 U concentrations of <0.26 ppt and <2.3 ppt, respectively; the best constraints on the radiopurity of sapphire.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CUPID, the Cuore upgrade with particle identification

CUPID, the CUORE Upgrade with Particle Identification, is a next-generation experiment to search for neutrinoless double beta decay (0 νββ ) and other rare events using enriched Li 2 100 MoO 4 scintillating bolometers. It will be hosted by the CUORE cryostat located at the Laboratori Nazionali del Gran Sasso in Italy. The main physics goal of CUPID is to search for 0 νββ of 100 Mo with a discovery sensitivity covering the full neutrino mass regime in the inverted ordering scenario, as well as the portion of the normal ordering regime with lightest neutrino mass larger than 10 meV. With a conservative background index of 10 −4 cts/(keV·kg·yr), 240 kg isotope mass, 5 keV FWHM energy resolution at 3 MeV and 10 live-years of data taking, CUPID will have a 90% C.L. half-life exclusion sensitivity of 1.8 · 10 27 yr, corresponding to an effective Majorana neutrino mass ( m ββ ) sensitivity of 9–15 meV, and a 3σ discovery sensitivity of 1 · 10 27 yr, corresponding to an m ββ range of 12–21 meV.

Alfonso, K. [Virginia Polytechnic Institute and St↗

The SPT-3G+ Experiment on the South Pole Telescope

Observations of the cosmic microwave background (CMB) offer an unparalleled opportunity to advance our understanding of fundamental physics. SPT-3G+ is an upgraded receiver for the arcminute-resolution South Pole Telescope (SPT) that plans to deploy in late 2028. SPT-3G+ will increase the CMB mapping speed of SPT by nearly an order of magnitude over the currently installed SPT-3G receiver. SPT-3G+ will have ~24,000 transition-edge sensor (TES) bolometers in two frequency bands with center frequencies at 95 GHz and 150 GHz that will be read out with microwave multiplexing. SPT-3G+ will measure the CMB lensing spectrum and galaxy clusters to constrain the growth of structure, dark matter, and dark energy. SPT-3G+ will also reach critical thresholds on inflationary constraints by combining data with BICEP/Keck, forming the South Pole Observatory (SPO). BICEP/Keck has deep degree-angular scale measurements but is currently delensing-limited, while SPT-3G+ will provide deep lensing measurements. Forecasts show that SPO will reach an uncertainty on the tensor-to-scalar ratio $r$ of $\sigma(r) \sim 1.2\times 10^{-3}$ by 2034. A detection at these levels would provide evidence of inflation and probe new physics at grand unified theory energy scales, while no detection would exclude large classes of models and shift the scientific paradigm describing the early universe. I will give an overview of SPT-3G+ including its design and current status.

Simon, Sara M. [Fermilab] (ORCID:0009000006683584)↗

Low energy backgrounds and excess noise in a two-channel low-threshold calorimeter

Here, we describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a transition edge sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: “shared” multichannel events with a pulse shape consistent with substrate athermal phonon events and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These “singles” are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.

47 OTHER INSTRUMENTATION↗

Data-driven background model for the CUORE experiment

Here, we present the model we developed to reconstruct the CUORE radioactive background based on the analysis of an experimental exposure of 1038.4 kg yr. The data reconstruction relies on a simultaneous Bayesian fit applied to energy spectra over a broad energy range. The high granularity of the CUORE detector, together with the large exposure and extended stable operations, allow for an in-depth exploration of both spatial and time dependence of backgrounds. We achieve high sensitivity to both bulk and surface activities of the materials of the setup, detecting levels as low as 10 nBq kg −1 and 0.1 nBq cm −2 , respectively. We compare the contamination levels we extract from the background model with prior radio-assay data, which informs future background risk mitigation strategies. The results of this background model play a crucial role in constructing the background budget for the CUPID experiment as it will exploit the same CUORE infrastructure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗