Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “blockage effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

AWAKEN Dual-Doppler Lidar (ADDLidar) Field Campaign Report

The AWAKEN Dual-Doppler Lidar (ADDLidar) experiment was conducted as part of the larger AWAKEN field campaign (https://www.nrel.gov/wind/awaken.html). The American Wake Experiment (AWAKEN) is an international, multi-institutional wind energy field campaign that was conducted from May 2022 to 2024, in the vicinity of the King Plains wind farm in north central Oklahoma. The goal of AWAKEN was to provide observations to better understand interactions between wind turbines in a wind farm and the interactions between the wind farm as a whole and the atmosphere. The focus of the ADDLidar campaign was to provide height-resolved measurements of wind speed and direction at key locations upwind of the wind farm to characterize the inflow and possible blockage effects upwind of the farm. Specifically, dual-Doppler scanning methods were employed to create a number of so-called virtual towers (Calhoun et al 2006, Debnath et al. 2017, Fernando et al. 2019, Hill et al. 2010, Newman et al. 2016, Newsom et al. 2008, 2015) upwind of the farm. The ADDLidar campaign involved the deployment of two U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility scanning Doppler lidars (S/N 236 and 237) to AWAKEN sites A4 (36.361894°, -97.356352°) and A7 (36.347259°, -97.389968°). Both sites are located approximately 29 km south of the ARM Southern Great Plains (SGP) observatory C1 site, as shown in Figure 1. These sites were chosen for their close proximity to the most southerly row of turbines in the King Plains wind farm.

54 ENVIRONMENTAL SCIENCES↗

Investigating the relationship between simulation parameters and flow variables in simulating atmospheric gravity waves for wind energy applications

Wind farms, particularly offshore clusters, are becoming larger than ever before. Besides influencing the surface wind flow and the inflow for downstream wind farms, large wind farms can trigger atmospheric gravity waves in the inversion layer and the free atmosphere aloft. Wind-farm-induced gravity waves can cause adverse pressure gradients upstream of the wind farm, which contribute to the global blockage effect, and can induce favorable pressure gradients above and downstream of the wind farm that enhance wake recovery. Numerical modeling is a powerful means of studying these wind-farm-induced atmospheric gravity waves, but it comes with the challenge of handling spurious reflections of these waves from domain boundaries. Typically, approaches which employ radiation boundary conditions and forcing zones are used to avoid these reflections. However, the simulation setup of these approaches relies heavily on ad hoc processes. For instance, the widely used Rayleigh damping method requires ad hoc tuning to produce a setup that may only produce satisfactory results for a particular case. To provide more systematic guidance on setting up realistic simulations of atmospheric gravity waves, we conduct a large-eddy simulation (LES) study of flow over a 2D hill and through a wind farm canopy that explores the optimum domain size and damping layer setup depending on the fundamental parameters which determine the flow characteristics. In this work, we only consider linearly stratified conditions (i.e., no inversion layer), thereby focusing on internal gravity waves in the free atmosphere and their reflections from the domain boundaries. This type of flow is governed by a single Froude number, which dictates most of the internal wave properties, such as wavelength, amplitude, and direction. This, in turn, will dictate the optimum domain size and Rayleigh damping layer setup. We find the effective horizontal and vertical wavelengths (the representative wavelengths of the entire wave spectrum) to be the appropriate length scales to size the domain and damping layer thickness, and the optimal Rayleigh damping coefficient scales with the Brunt–Väisälä frequency. Considering Froude numbers seen in wind farm applications, we propose recommendations to limit the reflections to less than 10 % of the total upward-propagating wave energy. Typically, damping is done at the top boundary, but given the non-periodic lateral boundary conditions of practical wind farm simulation domains, we find that damping the inflow–outflow boundaries is of equal importance to damping the top boundary. The Brunt–Väisälä frequency-normalized damping coefficient should be between 1 and 10. The damping layer thickness should be at least one effective vertical wavelength; damping layers exceeding 1.5 times the vertical wavelength are found to be unnecessary. The domain length and height should accommodate at least one effective horizontal and vertical wavelength, respectively. Moreover, Rayleigh damping does not damp the waves completely, and the non-damped energy might accumulate over the simulation time.

17 WIND ENERGY↗

Influence of simple terrain on the spatial variability of a low-level jet and wind farm performance in the AWAKEN field campaign

In wind energy research, scientific challenges are often associated with complex terrain sites, where orography, vegetation, and buildings disrupt flow uniformity. However, even sites characterized as simple terrain can exhibit significant spatial variability in wind speed, particularly during stable boundary layers (SBLs) and low-level jets (LLJs). This study investigates these terrain interactions using both simulations and observations from the American WAKe ExperimeNt (AWAKEN). We employ a multiscale Weather Research and Forecasting (WRF) model simulation, integrating mesoscale forcing in the coarse domains and representing three rows of turbines from the King Plains wind farm as generalized actuator disks (GAD) in the large-eddy simulation (LES) domains. During a nocturnal LLJ event on 3 April 2023, the downstream, wake-affected turbine rows outperformed the upstream, unwaked row by 25 %–51 %. This counterintuitive result arises from terrain-induced streamwise variations in hub-height wind speed of approximately 4 m s −1 over 5 km – equivalent to ∼50 % of the upstream reference speed. This enhancement outweighs the wake-induced reduction in mean wind speed (∼12 %) and global blockage effects reported in the literature (∼1 %–3.4 %). The multiscale simulations capture the intra-farm spatial variability in power performance observed in SCADA data. Terrain-induced vertical displacement of the LLJ, coupled with large wind shear below the jet maximum, drives the substantial streamwise acceleration within the wind farm. These findings underscore the importance of accounting for spatial variability related to terrain, even in simple landscapes, particularly during LLJ conditions. Incorporating such effects into reduced-order modeling frameworks for wind farm design and control could significantly enhance their effectiveness.

17 WIND ENERGY↗

Quantifying wind plant blockage under stable atmospheric conditions

Wind plant blockage reduces the wind velocity upstream undermining turbine performance for the first row of the plant. We assess how atmospheric stability modifies the induction zone of a wind plant in flat terrain. We also explore different approaches to quantifying the magnitude and extent of the induction zone from field-like observations. To investigate the influence from atmospheric stability, we compare simulations of two stable boundary layers using the Weather Research and Forecasting model in large-eddy simulation mode, representing wind turbines using the generalized actuator disk approach. We find a faster cooling rate at the surface, which produces a stronger stably stratified boundary layer, amplifies the induction zone of both an isolated turbine and of a large wind plant. A statistical analysis on the hub-height wind speed field shows wind slowdowns only extend far upstream (up to 15D) of a wind plant in strong stable boundary layers. To evaluate different ways of measuring wind plant blockage from field-like observations, we consider various ways of estimating the freestream velocity upstream of the plant. Sampling a large area upstream is the most accurate approach to estimating the freestream conditions, and thus of measuring the blockage effect. Also, the choice of sampling method may induce errors of the same order as the velocity deficit in the induction zone.

54 ENVIRONMENTAL SCIENCES↗

Verification of induction zone models for wind farm annual energy production estimation

Fast engineering wake models are the backbone of wind farm annual energy production (AEP) estimators, whereas the addition of induction zone models in existing tools is a more recent response to rising concerns over wind farm blockage associated losses. Here, "blockage" describes the combined induction fields of all wind turbines inside a farm. Unlike the term might suggest, blockage not only reduces flow speeds, but also increases them; for instance along the outer edges of wind farms. Evaluating the overall impact on AEP of these gains and losses necessitates accurate wind farm induction models. Whilst engineering wake models are tuned to predict wind farm performance, existing induction zone models are all derived for accurately predicting the near field induction not the far field value—important for wind farm simulations. This paper presents the induction models implemented in the wind farm simulation tool PyWake, as well as results from novel analytical models and compares their far field predictions to RANS-AD simulations of different turbines. We demonstrate that when including blockage in AEP simulations, the downstream speed-ups need to be included to avoid an unrealistic bias toward AEP loss and that wake expansion significantly impacts induction at rated thrust levels.

17 WIND ENERGY↗

Experimental investigation of turbulent wake flows in a helically wrapped rod bundle in presence of localized blockages

In nuclear sodium fast reactors, bundles of rods are tightly packed into a triangular lattice, enclosed in a hexagonal duct, and each pin is spirally wrapped with a thin wire. Flow blockages can potentially impact the local flow characteristics and heat transfer mechanisms in the bundle due to its small subchannel size. The effects of the blockage on the flow structures and heat transfer mechanisms are important aspects that require an accurate investigation. In this study, the flow-field characteristics in the vicinity of a blockage located in the exterior subchannel of rod bundles with helically wrapped wires were experimentally investigated. The velocity fields in the exterior subchannel were acquired by applying matched-index-of-refraction and time-resolved particle image velocimetry (TR-PIV) techniques for Reynolds numbers of Re 1 = 4000 and Re 2 = 17 000, i.e., equivalent to Rew 1 = 19 600 and Rew 2 = 83 200, respectively, based on the blockage width. The results from the TR-PIV measurements revealed an arch-shaped vortex with a large flow recirculation and a pair of counter-rotating vortices in the wake region downstream of the blockage, which is commonly observed in the wake flow of bluff bodies. The relative lateral distance and angle between the two vortices decreased when the Reynolds numbers increased. Profiles of maximum turbulence intensity along the shear layers illustrated the transition process including the growth, peak, and decay along the flow direction. From the spectral analysis of the turbulent velocities extracted at points along the shear layer, the Strouhal numbers ( St ) representing the vortex shedding frequency were found to be St = 0.25 and St = 0.56 for the left and right shear layers, respectively. Characteristics of shear layers generated by the blockage in the exterior subchannel were investigated via the two-point cross correlation of fluctuating velocities. The patiotemporal cross correlations of turbulent velocities, computed at points in the region where the left shear layer exhibited rolling effects and vortex breakdowns, were considerably wider and longer. The convection velocity U c was estimated to be ~0.82 U m to 0.93 U m . Proper orthogonal decomposition (POD) analysis was applied to the instantaneous velocity fields to extract the statistically dominant flow structures. It was found that POD modes 2–3 and 4–5 formed the pair modes when the corresponding POD temporal coefficients depicted sinusoidal shapes and exhibited nearly circular orbits in the phase space. Spectral analysis of the POD temporal coefficients confirmed the vortex shedding frequencies detected in the analysis of turbulent velocities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hierarchical Galloaluminosilicate MFI Catalysts for Ethane Nonoxidative Dehydroaromatization

This study presented an approach to overcome diffusion limitation and imbalance between Brønsted and Lewis acidities that affect conversion and aromatic yield in alkane nonoxidative dehydroaromatization (DHA) conversion. Three different Ga-promoted ZSM-5 catalysts were synthesized for the ethane DHA reaction. The hierarchical galloaluminosilicate Meso-GaZSM-5 was prepared by the solid-state crystallization technique wherein Ga was introduced through the in situ synthesis process. The microporous galloaluminosilicate Micro-GaZSM-5 was synthesized by the hydrothermal technique wherein Ga was introduced in situ during zeolite formation. The hierarchically structured Ga-Meso-ZSM-5 was synthesized by the solid-state crystallization method, but the Ga was introduced by the incipient wetness method. Additional Pt was incorporated by the incipient wetness technique for all three catalysts to enhance the DHA activity. The solid-state crystallization technique created the hierarchical structure without using a template. With the in situ technique, Ga species replaced the Al framework, reducing the strong Brønsted acidity. Meanwhile, they created the extraframework GaO + , introducing the strong Lewis acid sites into catalysts. Due to better synergistic interaction between the oxidation state of metals, acidic properties, and catalyst porosity, Pt-Meso-GaZSM-5 showed higher C 2 H 6 conversion and aromatic selectivity. The improvement on diffusivity not only reduces the effect of channel blockage but also improves the utilization of active sites. As a result, this work sheds light on the direct, nonoxidative conversion of shale gas without going through the syngas route.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

American WAKE Experiment (AWAKEN) Field Campaign Report

The American WAKE experimeNt (AWAKEN) was a large-scale, international collaborative field campaign funded primarily by the U.S. Department of Energy (DOE) Wind Energy Technologies Office. Its main purpose was to gather detailed observations of wind farm-atmosphere interactions to improve understanding of wind farm physics, validate and improve simulation tools, lower uncertainties in wind farm modeling, understand environmental impacts, and ultimately reduce the cost and increase the reliability of wind energy systems. The campaign specifically focused on seven testable hypotheses that include characterizing wind turbine and wind farm wake effects, wind farm blockage, turbulent mixing, structural loading impacts, local environmental impacts, and testing wind farm control technologies. AWAKEN was a highly collaborative effort involving numerous agencies, including: DOE, through the Wind Energy Technologies Office and the Office of Science Atmospheric Radiation Measurement (ARM) User Facility, the U.S. Department of Commerce through the National Oceanic and Atmospheric Administration, many American universities, and internationally funded collaborators from Germany and Brazil.

17 WIND ENERGY↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

On the retardation mechanisms of citric acid in ettringite-based binders

This study aims to obtain insights into the retardation mechanism of citric acid in an ettringite-based binder from ladle slag and gypsum. The hydration kinetics and phase assemblage of the binder were experimentally investigated and thermodynamically modelled. Additionally, the effects of citric acid on synthetic ettringite were studied to obtain further understanding of the interaction between this organic ligand and the crystal. Experimental results reveal that citric acid works as an inhibitor of ettringite's formation leading to the precipitation of monosulfate and gypsum; the ettringite surface blockage by citrate ligand effectively prevents precipitation of this crystal. This leads to an overestimation in the precipitation of ettringite in the thermodynamic model due to this kinetic barrier imposed by the ligand. Thermodynamic modelling suggests ettringite, monosulfate, aluminum hydroxide, and strätlingite as main hydrates in this binder, whereas an intermixed C–(A–)S–H gel was observed experimentally instead of strätlingite.

36 MATERIALS SCIENCE↗

Verification and Validation of Flow Confinement Modeling using OpenFAST Source Panel Method

Blockage or flow confinement effects in scale wind and water turbine testing in experimental facilities, including wind and water tunnels and tow tanks, can significantly alter incident aerodynamic and hydrodynamic loads, turbine performance (thrust, torque, power output), and wake dynamics compared to unconfined conditions. As scale model tests are key sources of OpenFAST model validation measurements, directly modeling flow confinement and its effects in OpenFAST enables improved model validat

Kim, Dongyoung [Sandia National Laboratories (SNL-↗

A Green's Function Wind Turbine Induction Model That Incorporates Complex Inflow Conditions

ABSTRACT In this work, we develop a new analytical turbine induction model that can incorporate complex inflow conditions including cases where the wind velocity and temperature profiles can vary as functions of height. This induction model is derived from the linearized Navier–Stokes and leads to a second‐order ODE that can be solved using a Green's function formulation. The corresponding Green's function for several configurations are found including the infinite domain, semi‐infinite domain with ground plane, and a power law velocity inflow profile. The results of this approach are then compared with simulations of the turbine induction field using the AMR‐Wind CFD solver with a uniformly loaded actuator disk model. These comparisons show that the Green's function approach captures the centerline blockage, three‐dimensional blockage flow field, and streamwise velocity slow down, with very good agreement for lower thrust conditions and at larger distances away from rotor disk. The effects of shear on the turbine blockage were also compared using a power law inflow profile, and we show that this approach matches the CFD predictions for the cases considered.

17 WIND ENERGY↗

Blockage and speedup in the proximity of an onshore wind farm: A scanning wind LiDAR experiment

To maximize the profitability of wind power plants, wind farms are often characterized by high wind turbine density leading to operations with reduced turbine spacing. As a consequence, the overall wind farm power capture is hindered by complex flow features associated with flow modifications induced by the various wind turbine rotors. In addition to the generation of wakes, the velocity of the incoming wind field can reduce due to the increased pressure in the proximity of a single turbine rotor (named induction); a similar effect occurs at the wind-farm level (global blockage), which can have a noticeable impact on power production. On the other hand, intra-wind-farm regions featuring increased velocity compared to the freestream (speedups) have also been observed, which can be a source for a potential power boost. To quantify these rotor-induced effects on the incoming wind velocity field, three profiling LiDARs and one scanning wind LiDAR were deployed both before and after the construction of an onshore wind turbine array. The different wind conditions are classified according to the ambient turbulence intensity and streamwise/spanwise spacing among wind turbines. The analysis of the mean velocity field reveals enhanced induction and speedup under stably stratified atmospheric conditions. Additionally, a reduced horizontal area between adjacent turbines has a small impact on the induction zone but increases significantly the speedup between adjacent rotors.

17 WIND ENERGY↗

Progress on Optimizing Wind Farms and Rotor Designs Using Adjoints

Modern wind plants are increasingly tasked with multiple performance objectives. In addition to designing plants that maximize power output and minimize the levelized cost of energy (LCOE), the design and operation of wind plants is increasingly influenced by challenges regarding grid integration of variable generation renewables. This places a growing emphasis on making wind plants more controllable and predictable. WindSE is a Reynolds-averaged Navier-Stokes (RANS) model designed around analytical gradient and adjoint methods, with the ability to capture terrain-induced effects, as shown in Figure 1. The recent addition of an unsteady solver with an actuator line method (ALM) and ongoing work to enable massively parallel optimizations gives it a unique niche to explore coupled plant-level controls and design problems. This code is an open source python package built on the FEniCS framework that utilizes fast, parallel PETSc solvers to model fluid flow throughout wind-farm scale domains. Two recent studies performed using WindSE demonstrate the capability to optimize under a wide variety of flow conditions and objective functions. In the first, we present an optimization focused on modifying the layout of a wind farm with a fixed number of turbines for maximum total power output [1]. This study highlights the ability to quickly perform simulations using the steady Navier-Stokes solver combined with rotors represented as actuator disks while also stressing the importance of capturing terrain-induced effects. Gradient-based optimization using the RANS equations is viable due to the inclusion of efficiently computed adjoint derivatives. We interpret the physical results of the optimal layout and also discuss the computational cost of scaling to larger problems. In the second study, we present the capabilities of the unsteady Navier-Stokes solver, where rotor-blade profiles represented by actuator lines are optimized to enhance wake steering effects and overall power production [2]. We quantify the wind plant performance gains obtained from this type of simultaneous control co-design optimization as compared to optimizing the blade design and yaw independently. Figure 2 shows the differences between a baseline two-turbine system and an optimized system where we fine-tune the blade chord profile. Results and challenges from each study are quickly summarized and used to motivate the current development efforts within WindSE. Current and future work is focused on enabling higher-resolution studies with more degrees of freedom through parallelization of both the simulation and optimization algorithms. We present benchmarking results to show that WindSE performs well in both weak- and strong-scaling tests and further demonstrate that the optimizer obtains the same convergence rates in both shared- and distributed-memory environments. Using larger wind farms, we can study deep-array effects within an optimization context, allowing the use of objective functions that have been previously unstudied. As an example, we present ongoing work on a blockage metric which characterizes the loss of available kinetic energy due to wake effects from multiple upstream turbines.

adjoint optimization↗

Simulation of a High-Confinement Tidal Energy Array (Abstract)

When the projected area of a current turbine array occupies a substantial fraction of a tidal or river channel cross-sectional area, the confinement associated with the channel boundaries substantially increases turbine efficiency. This effect can be exploited to substantially reduce the levelized cost of energy for current turbine arrays. However, the presence of such an array will affect inflow velocity, water depth, and circulation in the surrounding area. This has implications for array performance and environmental impacts. This project combines existing numerical modeling capability from PNNL with an understanding of confined array performance from UW. The work will 1) Simulate tidal currents and water surface elevation in a regional circulation model that includes the Knik Arm site at appropriate resolution; 2) Incorporate a varying thrust coefficient into this model that reflects the outcomes of tidal hydrodynamic simulations of confined turbine arrays; 3) Use the model to determine the effects of array operation on water levels and inflow conditions as a function of different blockage ratios and control strategies; and 4) Identify the “far field” environmental implications of operating an array of this type. UW will use the outputs from this model to evaluate the implications of “feedback effects” and variable inflow conditions on levelized cost of energy estimates for a confinement exploiting array of cross-flow turbines.

16 TIDAL AND WAVE POWER↗

Effects of small marine energy deployments on oceanographic systems

The placement and operation of marine energy deployments in the ocean have the potential to change flow patterns, decrease wave heights, and/or remove energy from the oceanographic system. Changes in oceanographic systems resulting from harvesting marine energy, particularly tidal and wave energy, may be of concern. These changes include alterations in nearfield and farfield physical processes, as well as potential secondary environmental effects such as changes in sediment transport patterns, biological processes, or coastal erosion. Knowledge of changes in oceanographic systems associated with marine energy is primarily available from numerical modeling studies, informed by some laboratory tests and very few field measurements. A literature review was conducted using the Tethys knowledge base and other online sources, building on conclusions from the Ocean Energy Systems-Environmental State of the Science report. Potential changes in oceanographic systems that may be caused by marine energy differ between tidal and wave devices because of different extraction mechanisms and siting locations. Numerical models show that tidal extraction on the order of hundreds of megawatts or with significant channel blockage is required to create changes in oceanographic processes that exceed natural variability. Effects from wave energy extraction in arrays are localized and dependent on array spacing and proximity to the shore. Here the available evidence supports the conclusion that the risk of significant environmental effects from such changes could be retired (i.e., less investigation required for every project) for small deployments—those representative of the state of the industry in 2021. Determining changes in oceanographic systems to be low risk for small deployments can thereby streamline environmental consenting by reducing monitoring needs at this early stage in the industry.

54 ENVIRONMENTAL SCIENCES↗