Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “blind system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Basin and Range Investigation for Developing Geothermal Energy: Exploration Data

This data package includes exploration material from the Basin & Range Investigation for Developing Geothermal Energy [in Hidden Systems] project (BRIDGE), which is part of a broader initiative to advance the exploration of hidden geothermal resources in the Basin & Range Province of the western U.S. Data modalities include a helicopter-borne time-domain electromagnetic survey, magnetotellurics, 2-meter temperature measurements, ground-based gravity and legacy aeromagnetic surveys, geochemistry, geologic mapping, LiDAR analysis, 3D models, associated geospatial data, and a bibliography of existing data and references utilized in prospect characterization and conceptual modeling. Key files are in CSV, Geosoft, and Geotools formats. Please refer to READMEs for dataset-specific information. Where applicable, acquisition data and inversion models for a particular prospect or area of interest are organized separately. This BRIDGE data package is the product of a collaboration led by Sandia National Laboratories with partners from Geologica Geothermal Group, Inc., the U.S. Navy Geothermal Program Office, and consultants Steven Sewell (Australis Geoscience Ltd) and William Cumming (Cumming Geoscience). The project's areas of interest (AOIs) are based off priority areas of interest in the southwestern portion of the Nevada Play Fairway map, distribution across tectonic provinces, accessibility, and the project team's extensive experience in the region. AOIs cover about a dozen basins that include unexplored prospects, partially explored prospects, and some developed analogue resources that provide validation cases. Many unexplored and partially explored prospects are on U.S. Department of Defense (DoD) land, though adjacent lands are included as well.

15 GEOTHERMAL ENERGY↗

Hawai‘i Play Fairway (Final Report)

Most of Hawai'i's geothermal resources are blind—their manifestations, such as hot springs and steam vents, do not appear on the ground surface because the heated water flows far below. With the exception of $K\bar{i}lauea East Rift Zone$, in most areas of Hawai'i, high lateral permeability in the first kilometer below ground surface prevents surface thermal features from developing. As a methodology for discovering these blind resources, Play Fairway Analysis (PFA) involves finding potential locations of blind hydrothermal systems and describing potential geothermal sources in rift-zone settings. Using the PFA to find Hawai'i's geothermal resources, the University of Hawai'i (UH) conducted the Hawai‘i Play Fairway Project, Hawai'i's first statewide geothermal resource assessment since 1985. Sponsored by the U.S. Department of Energy, the Hawai'i Play Fairway Project provided an updated resource assessment, a roadmap for additional exploration activities, and the identification of areas for further exploration. Benefitting from UH's core competency in earth sciences and experienced geothermal researchers, the project comprised three phases. During the first phase, the team identified, compiled, and ranked existing geologic, groundwater, and geophysical datasets relevant to subsurface heat, fluid and permeability. Using a Bayesian statistical approach, the team developed a statistical methodology to integrate these data into a resource probability map. The team evaluated the confidence in the probability value and considered development viability of areas with geothermal resources. With these analyses, the team identified 10 locations in the Hawaiian Islands for exploration activities. For the second phase, the team collected new groundwater data in 10 locations across the state and new geophysical data on $L\bar{a}na‘i, Maui$, and central Hawai'i Island and modeled topographically induced stress to better characterize subsurface permeability. Analyzing the subsurface stresses, the team evaluated the potential for fracture-induced permeability. The team inverted the MT and gravity data to produce 3D models of resistivity and density, respectively, on $L\bar{a}na‘i$, across $Haleakal\bar{a}'s$ SW rift (Maui), and surrounding Mauna Kea (Hawai‘i Island). The team developed and applied a new method for incorporating depth information about resistivity, density, and potential for fracture-induced permeability into the statistical method for computing resource probability in these three focus areas. The team incorporated the new groundwater results with the new geophysical results and the calculations of potential for fracture-induced permeability to produce updated maps of resource probability and confidence. Through combining data from the first and second phases, the team determined locations for further exploration during the third phase. For MT and gravity surveys, the team recommended $Kaua'i's$ $L\bar{i}hu'e$ $Basin$, the east rift of $Maui's$ $Haleakal\bar{a}$ volcano, and the southwest rift of Hawai'i Island's Mauna Loa volcano. The MT and gravity surveys aimed to enable improved confidence in the resource potential in these locations. For drilling deep groundwater well(s), the team recommended Southeast Mauna Kea and $L\bar{a}na's$ $P\bar{a}l\bar{a}wai$ $Basin$. During the third phase, further exploration involved drilling a groundwater well in $L\bar{a}na's$ $P\bar{a}l\bar{a}wai$ $Basin$ and performing more geophysical surveys. We deepened an existing water well proximal to our target area on $L\bar{a}na'i$ due to funding constraints that precluded us from spudding a new well that would exceed 1km depth. Drilling was preceded by a number of substantial elements including: writing an Environmental Assessment and the subsequent legal process, performance of deviation logging, lowering a camera down the well, coordinating site preparation with $P\bar{u}lama$ $L\bar{a}na'i$, shipping the UH-owned rig interisland, procuring supplies, and leading 3 community meetings on $L\bar{a}na'i$. Drilling occurred 24/7 the entire month of June 2019 over which time $L\bar{a}na'i$ $Well$ 10 was deepened from 427 m to 1057 m, with continuous core collected. We measured a roughly linear temperature gradient averaging 42°C/km and a maximum bottom hole temperature of 66°C. This gradient is more than twice the background for Hawai'i and within a range of gradients measured in this depth range for some exploration wells within KERZ. We consider these results encouraging for $L\bar{a}na'i's$ resource potential and recommend following with a slim hole within $L\bar{a}na'i's$ caldera (our target zone) to ~ 2 km. Further, the positive implications such results have for the island of O‘ahu are substantial - the shield stage of O'ahu's volcanoes ended 1-2 My earlier. However, O'ahu uses more electricity than the rest of the islands combined, and the utility recently called for 500-700MW of firm, dispatchable renewable electricity on O'ahu by 2033. In Phase 3, we also collected limited new encouraging groundwater data, and updated our thoughts on the probabilities of fluid and permeability at resource depths (Pr F = 1; Pr P = mostly unconstrained). Ultimately, we advocate for using our final probability of heat, and confidence in this probability, to drive the next phase of exploration. We contend further development of geothermal in Hawai‘i will enable the state to achieve its 100% renewable policy objective and Hawai'i to transition off of fossil fuels through geothermal discovery and development. The project not only produced a large amount of data and expanded the existing knowledge of Hawai'i's geothermal resources, but also produced publications, theses, presentations, core photos, datasets, media reports, television interviews, community events, and a blog. Students and new professionals benefitted from the project's hands-on research experiences and educational opportunities and earned awards and recognition.

15 GEOTHERMAL ENERGY↗

Holistic fleet optimization incorporating system design considerations

The methodology described in this article enables a type of holistic fleet optimization that simultaneously considers the composition and activity of a fleet through time as well as the design of individual systems within the fleet. Often, real-world system design optimization and fleet-level acquisition optimization are treated separately due to the prohibitive scale and complexity of each problem. Importantly, this means that fleet-level schedules are typically limited to the inclusion of predefined system configurations and are blind to a rich spectrum of system design alternatives. Similarly, system design optimization often considers a system in isolation from the fleet and is blind to numerous, complex portfolio-level considerations. In reality, these two problems are highly interconnected. To properly address this system-fleet design interdependence, we present a general method for efficiently incorporating multi-objective system design trade-off information into a mixed-integer linear programming (MILP) fleet-level optimization. This work is motivated by the authors' experience with large-scale DOD acquisition portfolios. However, the methodology is general to any application where the fleet-level problem is a MILP and there exists at least one system having a design trade space in which two or more design objectives are parameters in the fleet-level MILP.

97 MATHEMATICS AND COMPUTING↗

Automated Production of Optimization-Based Control Logics for Dynamic Facade Systems, with Experimental Application to Two-Zone External Venetian Blinds

The primary goal of this research is to devise a system that produces controllers for complex fenestration systems that perform nearly as well as Model Predictive Control but at a level of cost and implementation complexity that rivals simple heuristic controls. To this end, a cloud-based automated controller production system has been set up for a motorized external Venetian blind device, with a simple web interface that can be used by non-experts. The computation cost per controller is in the range of a few dollars, and the control logic is simple enough to be implemented on small and cheap distributed controllers. The web interface allows the user to specify some details of their particular building and window configuration, including orientation, latitude, interior geometries, and lighting and HVAC system parameters. Upon submittal, a cloud-based system configures the necessary files and commands, and then runs thousands of optimizations with them. Once the calculations are finished, the system produces a lookup table and interpolation-based controller scripts that can be used on a simple and cheap distributed controller. This paper describes the underlying models and optimization processes. It also describes the resulting control logics for two cases tested at Lawrence Berkeley National Laboratory’s Advanced Windows Testbed Facility: illuminance maximization subject to glare constraints; and lighting + HVAC energy minimization. The performance of the model-based controllers produced by the automated web-based system are compared to a heuristic ‘block beam’ controller in physical experiments at the Testbed. The experimental results are supplemented by simulation experiments with the same configuration as the Testbed. The results show the illuminance maximizing controller significantly outperforms the heuristic controller in terms of glare avoidance, and also outperforms it in terms of hours of daylight autonomy. The energy minimizing controller also outperforms the heuristic controller. This paper also discusses how the web-based system may be extended to consider other configurations, such as electrochromic windows and thermally massive HVAC systems. Potential roles for this type of system within the building design and construction industry are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Online Alpha Monitoring of High Cs-137 Hanford and SRS High Level Waste with Tensioned Metastable Fluid Detectors

The Department of Energy’s Hanford and Savannah River Sites maintain millions of gallons of caustic supernate and salt high activity waste in their high-level waste (HLW) tank farm inventories. The Savannah River Site is currently treating this waste with a calixarene-based solvent extraction of Cs-137 to reduce these inventories. Hanford is employing an at-tank crystalline silico titanate (CST) based solid phase extraction methodology to reduce their liquid HLW inventories. Due to the high solubility of Cs-137 and the relative insolubility of the actinides in these caustic waste forms, the beta to alpha radioactivity ratio can often exceed six orders of magnitude in the feed solutions to these treatment processes. This unique characteristic leads to significant technical challenges in making rapid gross alpha measurements in the presence of the overwhelming beta, gamma, as well as dissolved sodium salt in these HLW matrices. Conventional radioanalytical techniques, such as liquid scintillation analysis or gas flow proportional counting require significant radiochemistry preparation prior to the radiometric measurements for gross alpha activity. These required pretreatments render these technologies untenable for rapid quantification of gross alpha activity that could be required to support on or at-line measurements ensuring a waste stream will meet regulatory requirements. The radiation measurement properties of Tensioned Metastable Fluid Detectors (TMFDs) have been studied by Purdue University’s Taleyarkhan research group for well over a decade. Fluids tensioned to the appropriate degree will rupture when struck by radiation, resulting in a measurable cavitation event. The negative pressure generating this tension can be adjusted by centrifugal rotation or by acoustic means in such a way that these cavitation events can be generated from alpha radiation but will not be generated by beta or gamma radiation. Purdue University and the Savannah River National Laboratory are currently collaborating to develop a gamma/beta blind, spectroscopic alpha measurement system based on the Tensioned Metastable Fluid Detector technology to provide a potential solution for performing rapid gross alpha measurements on these high gamma/beta sample matrices. Measurements using the Indirect Drive Acoustically Tensioned Metastable Fluid Detectors developed as part of this collaboration were performed with an alpha emitting radionuclide. Successful determination of gross alpha activity was observed, indicating a potential pathway for rapid gross alpha measurements in remote-handled shielded cells or in process situations requiring online alpha monitoring. Measurements using this system have been conducted on high beta activity solutions, demonstrating the beta blind capability of this system. Measurements are currently underway to test the system’s capability to measure gross alpha activity on Savannah River Site high level waste high Cs-137 samples that have been measured by the SRNL radiochemistry team. This work was supported by the DOE EM Technology Development program.

DiPrete, David [Savannah River National Laboratory↗

STRIDES: a 3.9 per cent measurement of the Hubble constant from the strong lens system DES J0408−5354

We present a blind time-delay cosmographic analysis for the lens system DES J0408−5354. This system is extraordinary for the presence of two sets of multiple images at different redshifts, which provide the opportunity to obtain more information at the cost of increased modelling complexity with respect to previously analysed systems. We perform detailed modelling of the mass distribution for this lens system using three band Hubble Space Telescope imaging. We combine the measured time delays, line-of-sight central velocity dispersion of the deflector, and statistically constrained external convergence with our lens models to estimate two cosmological distances. We measure the ‘effective’ time-delay distance corresponding to the redshifts of the deflector and the lensed quasar |$D_{\Delta t}^{\rm eff}=$||$3382_{-115}^{+146}$| Mpc and the angular diameter distance to the deflector D_d = |$1711_{-280}^{+376}$| Mpc, with covariance between the two distances. From these constraints on the cosmological distances, we infer the Hubble constant H_0= |$74.2_{-3.0}^{+2.7}$| km s^−1 Mpc^−^1 assuming a flat ΛCDM cosmology and a uniform prior for Ω_m as |$\Omega _{\rm m} \sim \mathcal {U}(0.05, 0.5)$|⁠. This measurement gives the most precise constraint on H_0 to date from a single lens. Our measurement is consistent with that obtained from the previous sample of six lenses analysed by the H_0 Lenses in COSMOGRAIL’s Wellspring (H0LiCOW) collaboration. It is also consistent with measurements of H_0 based on the local distance ladder, reinforcing the tension with the inference from early Universe probes, for example, with 2.2σ discrepancy from the cosmic microwave background measurement.

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced Fenestration Controller (AFC) v1.0

The Advanced Fenestration Controller is the result of 5+ years of R&D to develop an advanced control system for Dynamic Facades (e.g., automated shades, blinds, etc.), electric lighting, and HVAC system in buildings. It can dynamically control those technologies to reduce electricity cost while increasing comfort. The work in FY22 focused on open-sourcing our development, per agreement with DOE.

Gehbauer, Christoph↗

Encryption of Signal Pulses to Replace Tamper-indicating Conduit

In order to verify signal integrity and point of origin for TTL pulse data used in IAEA systems, and to avoid the need for expensive tamper-indicating conduit or electronic techniques, we propose the development of a signal pulse signing and encryption in-line device. In measurement applications in which the data acquisition electronics is separate from the enclosed, sealed detector, tamper-indicating techniques are required to protect raw TTL pulse streams between the detector and the data acquisition module, i.e UMSR. The goal of this proposed project is to design a rad-tolerant transmitter that would mount inside the sealed detector system and a receiver in the sealed electronics cabinet with the data acquisition instrument. This transmitter/receiver pair would digitally sign and encrypt the pulse stream data at the detector then transmit the data to the sealed cabinet where the receiver would decrypt the data and reproduce the original pulse stream. Existing tamper indicating techniques, such as LiveWire’s spread spectrum time domain reflectometry rely on detecting physical changes to the wiring system and can be blind to fast coupling of micro-second wide pulses. Digital signing and encryption techniques such as the Sandia Laboratories Enhanced Data Authentication System (EDAS) are capable of encrypting communications data, i.e. RS-232, but are not capable reproducing a critical time correlated data streams. Recent NA-241 Safeguards Technology supported developments have reduced the need for special conduit to transmit data via Ethernet by incorporating the IAEA RAINSTORM data encryption and authentication protocol, a tamper indicator is still required to protect raw pulse data from detectors to the acquisition electronics. Encrypting pulse data is especially complicated for radiation detection instruments due to the time correlation data analysis that is performed on this data stream. Any corruption in the timing information will produce errors in measurement values.

97 MATHEMATICS AND COMPUTING↗

A computational modeling framework for pre-clinical evaluation of cardiac mapping systems

There are a variety of difficulties in evaluating clinical cardiac mapping systems, most notably the inability to record the transmembrane potential throughout the entire heart during patient procedures which prevents the comparison to a relevant “gold standard”. Cardiac mapping systems are comprised of hardware and software elements including sophisticated mathematical algorithms, both of which continue to undergo rapid innovation. The purpose of this study is to develop a computational modeling framework to evaluate the performance of cardiac mapping systems. The framework enables rigorous evaluation of a mapping system’s ability to localize and characterize (i.e., focal or reentrant) arrhythmogenic sources in the heart. The main component of our tool is a library of computer simulations of various dynamic patterns throughout the entire heart in which the type and location of the arrhythmogenic sources are known. Our framework allows for performance evaluation for various electrode configurations, heart geometries, arrhythmias, and electrogram noise levels and involves blind comparison of mapping systems against a “silver standard” comprised of computer simulations in which the precise transmembrane potential patterns throughout the heart are known. A feasibility study was performed using simulations of patterns in the human left atria and three hypothetical virtual catheter electrode arrays. Activation times (AcT) and patterns (AcP) were computed for three virtual electrode arrays: two basket arrays with good and poor contact and one high-resolution grid with uniform spacing. The average root mean squared difference of AcTs of electrograms and those of the nearest endocardial action potential was less than 1 ms and therefore appears to be a poor performance metric. In an effort to standardize performance evaluation of mapping systems a novel performance metric is introduced based on the number of AcPs identified correctly and those considered spurious as well as misclassifications of arrhythmia type; spatial and temporal localization accuracy of correctly identified patterns was also quantified. This approach provides a rigorous quantitative analysis of cardiac mapping system performance. Proof of concept of this computational evaluation framework suggests that it could help safeguard that mapping systems perform as expected as well as provide estimates of system accuracy.

59 BASIC BIOLOGICAL SCIENCES↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing alphafold-multimer-based protein complex structure prediction with MULTICOM in CASP15

To enhance the AlphaFold-Multimer-based protein complex structure prediction, we developed a quaternary structure prediction system (MULTICOM) to improve the input fed to AlphaFold-Multimer and evaluate and refine its outputs. MULTICOM samples diverse multiple sequence alignments (MSAs) and templates for AlphaFold-Multimer to generate structural predictions by using both traditional sequence alignments and Foldseek-based structure alignments, ranks structural predictions through multiple complementary metrics, and refines the structural predictions via a Foldseek structure alignment-based refinement method. The MULTICOM system with different implementations was blindly tested in the assembly structure prediction in the 15th Critical Assessment of Techniques for Protein Structure Prediction (CASP15) in 2022 as both server and human predictors. MULTICOM_qa ranked 3 rd among 26 CASP15 server predictors and MULTICOM_human ranked 7 th among 87 CASP15 server and human predictors. The average TM-score of the first predictions submitted by MULTICOM_qa for CASP15 assembly targets is ~0.76, 5.3% higher than ~0.72 of the standard AlphaFold-Multimer. The average TM-score of the best of top 5 predictions submitted by MULTICOM_qa is ~0.80, about 8% higher than ~0.74 of the standard AlphaFold-Multimer. Moreover, the Foldseek Structure Alignment-based Multimer structure Generation (FSAMG) method outperforms the widely used sequence alignment-based multimer structure generation.

59 BASIC BIOLOGICAL SCIENCES↗

PV Performance Modeling - Data and Resources

The Photovoltaic (PV) Performance Modeling Collaborative (PVPMC) organized a blind PV performance modeling intercomparison to allow PV modelers to blindly test their models and modeling ability against real system data. Measured weather and irradiance data were provided along with detailed descriptions of PV systems from two locations (Albuquerque, New Mexico, USA and Roskilde, Denmark). Participants were asked to simulate the plane-of-array irradiance, module temperature, and DC power output from six systems and submit their results to Sandia for processing. This dataset includes seven MS-Excel sheets with instructions, notes and all necessary data (weather, irradiance, temperature, power) used for the data analysis of the blind modeling comparison. The hourly data represent six different systems from Albuquerque, NM and Roskilde, Denmark over a period of one year. These data are useful for PV performance model validation studies.

14 SOLAR ENERGY↗

TDCOSMO. IX. Systematic comparison between lens modelling software programs: time delay prediction for WGD 2038-4008

The importance of alternative methods for measuring the Hubble constant, such as time-delay cosmography, is highlighted by the recent Hubble tension. It is paramount to thoroughly investigate and rule out systematic biases in all measurement methods before we can accept new physics as the source of this tension. In this study, we perform a check for systematic biases in the lens modelling procedure of time-delay cosmography by comparing independent and blind time-delay predictions of the system WGD 2038-4008 from two teams using two different software programs: GLEE and LENSTRONOMY. The predicted time delays from the two teams incorporate the stellar kinematics of the deflector and the external convergence from line-of-sight structures. The un-blinded time-delay predictions from the two teams agree within 1.2σ, implying that once the time delay is measured the inferred Hubble constant will also be mutually consistent. However, there is a ~4σ discrepancy between the power-law model slope and external shear, which is a significant discrepancy at the level of lens models before the stellar kinematics and the external convergence are incorporated. We identify the difference in the reconstructed point spread function (PSF) to be the source of this discrepancy. When the same reconstructed PSF was used by both teams, we achieved excellent agreement, within ~0.6σ<, indicating that potential systematics stemming from source reconstruction algorithms and investigator choices are well under control. We recommend that future studies supersample the PSF as needed and marginalize over multiple algorithms or realizations for the PSF reconstruction to mitigate the systematics associated with the PSF. A future study will measure the time delays of the system WGD 2038-4008 and infer the Hubble constant based on our mass models.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of Millimeter-wavelength Flares from Two Accreting White Dwarf Systems in the SPT-3G Galactic Plane Survey

Blind discoveries of millimeter-wave transient events in nontargeted surveys, as opposed to follow-up or pointed observations, have only become possible in the past decade using cosmic microwave background surveys. Here we present the first results from the SPT-3G Galactic Plane Survey—the first dedicated high-sensitivity, wide-field, time-domain, millimeter-wave survey of the Galactic Plane, conducted with the South Pole Telescope (SPT) using the SPT-3G camera. The survey field covers approximately 100 deg 2 near the Galactic center. In 2023 and 2024, this survey consisted of roughly 1500 individual 20 minute observations in three bands centered at 95, 150, and 220 GHz, with plans for more observations in the coming years. We report the detection of two transient events exceeding a 5σ threshold in both the 95 and 150 GHz bands in the first 2 yr of SPT-3G Galactic Plane Survey data. Both events are unpolarized and exhibit durations of approximately 1 day, with peak flux densities at 150 GHz of at least 50 mJy. The peak isotropic luminosities at 150 GHz are on the order of 10 31 erg s −1 . Both events are associated with previously identified accreting white dwarfs. Magnetic reconnection in the accretion disk is a likely explanation for the observed millimeter flares. In the future, we plan to expand the transient search in the Galactic Plane by lowering the detection threshold, enabling single-band detections, analyzing lightcurves on a range of timescales, and including additional data from future observations.

Wan, Y. [Univ. of Illinois at Urbana-Champaign, IL↗

Broadband, 920-nm mirror thin film damage competition

This year’s competition proposed to survey the state-of-the-art broadband, near-IR multilayer dielectric (MLD) mirrors designed for ultra-short, pulsed laser applications. The requirements for the coatings were a minimum reflection of 99.5% at 45-degree incidence angle for S-polarization from 830 nm to 1010 nm and group delay dispersion (GDD) < ± 50 fs 2 . The participants in this effort selected the coating materials, coating design, and deposition method. Samples were damage tested at a single testing facility to enable direct comparison among the participants using a 25 ± 5 fs OPCPA laser system operating at 5 Hz. A double blind test assured sample and submitter anonymity. The damage performance results, sample rankings, details of the deposition processes, coating materials and substrate cleaning methods are shared here. We found that multilayer coatings using tantala and/or hafnia as high index materials were top performers within several coating deposition groups. Specifically, dense coatings by ion-beam sputtering (IBS), magnetron sputtering (MS), and electron-beam ion assisted deposition (e-beam IAD) exhibited highest damage initiation onset (LIDT) while e-beam coatings were low performers. In addition, damage growth onset (LDGT) was also examined and the results are reported here for all samples as this performance metric plays an important role in establishing the safe operational conditions for larger aperture, ultrashort pulsed lasers. As a result, not all coating samples in the survey met the GDD requirements stated above and associated measurements are discussed in the context of the present and past competitions focused on similar broadband, near-IR MLD coatings.

42 ENGINEERING↗

Detection and imaging of chemicals and hidden explosives using terahertz time-domain spectroscopy and deep learning

Detecting concealed chemicals and explosives remains a critical challenge in global security. Terahertz time-domain spectroscopy (THz-TDS) offers a promising non-invasive and stand-off detection technique owing to its ability to penetrate optically opaque materials without causing ionization damage. While many chemicals exhibit distinct spectral features in the terahertz range, conventional terahertz-based detection methods often struggle in real-world environments, where variations in sample geometry, thickness, and packaging can lead to inconsistent spectral responses. In this study, we present a chemical imaging system that integrates THz-TDS with deep learning to enable accurate pixel-level identification and classification of different explosives. Operating in reflection mode and enhanced with plasmonic nanoantenna arrays, our THz-TDS system achieves a peak dynamic range of 96 dB and a detection bandwidth of 4.5 THz, supporting practical, stand-off operation. By analyzing individual time-domain pulses with deep neural networks, the system exhibits strong resilience to environmental variations and sample inconsistencies. Blind testing across eight chemicals—including pharmaceutical excipients and explosive compounds—resulted in an average classification accuracy of 99.42% at the pixel level. Notably, the system maintained an average accuracy of 88.83% when detecting explosives concealed under opaque paper coverings, demonstrating its robust generalization capability. These results highlight the potential of combining advanced terahertz spectroscopy with neural networks for highly sensitive and specific chemical and explosive detection in diverse and operationally relevant scenarios.

Imaging and sensing↗