33 records · Page 2

Computational studies of hydraulic stressors for biological performance assessment in a hydropower plant with Kaplan turbine

We report Hydropower is currently one of the preeminent sources of renewable energy in the United States and globally. Hydropower plants also have detrimental impacts on the environment and ecology, including direct impacts to anadromous fish populations. The computational fluid dynamics (CFD) – based Biological Performance Assessment (BioPA) toolset is used for biological evaluations of fish passage through hydropower plants. The hydraulic environment of a hydropower plant was evaluated using CFD coupled with discrete element method (DEM) simulations. The predicted flow field and particle collision rate were validated against the experimental data in a water flume that has an idealized hydroturbine distributor geometry. Flow simulations were conducted to evaluate the hydraulic stressors, such as nadir pressure, fluid shear, runner collision, in a physical scale in a hydropower plant with Kaplan turbine which are responsible for injury and mortality of fish in a downstream migration. The cumulative exposure probability for the nadir pressure and collision with turbine runner was found to decrease with increased discharge rate. The lowest discharge rate shows the higher value of cumulative shear exposure probability. The maximum value of collision velocity increases with increased discharge rate. We offer the conclusions that will help in understanding various hydraulic stressors for biological assessment for environmentally sustainable hydroturbine passage.

13 HYDRO ENERGY↗

Tutorial Guide: Biological Performance Assessment (BioPA) Toolset for High Head Passage

Higher head facilities that impede migratory fish use trap and transport to varying levels of success. There are ongoing efforts to improve the downstream passage. One such effort seeks to attract fish by using large flow, shedding most of the attraction flow, and routing fish downstream using minimal flows. To demonstrate BioPA is suitable for improving downstream high head fish passage, a similar type flow path will be used in this document.

54 ENVIRONMENTAL SCIENCES↗

Investigating lab-scaled offshore wind aerodynamic testing failure and developing solutions for early anomaly detections

As offshore wind systems become more complex, the risk of human error or equipment malfunction increases during experimental testing. This study investigates a lab-scale incident involving a 1 : 50 scale 5 MW wind turbine, where a generator failure led to rotor overspeed and a blade–tower strike. To improve early fault detection, we propose a data-driven method based on multivariate long short-term memory (LSTM) models. High-frequency measurements are projected onto principal components, and anomalies are identified using reconstruction error and its time derivative. Two models are trained on different healthy datasets and tested using single- and multi-principal component (1PC and MPC) variations. Results show that combining both error and error derivative improves detection accuracy. The 1PC model detects faults faster, has a higher recall rate, and achieves a 43 % improvement in anomaly detection accuracy, while the MPC model yields higher precision. This approach provides a simple and effective tool for early anomaly detection in lab-scale experiments, helping to reduce the risk of future failures during the testing of new technologies.

17 WIND ENERGY↗

Validation of a lightning protection system for a fusion-welded thermoplastic composite wind turbine blade tip

Fusion welding for thermoplastic composite wind turbine blades is being investigated as a replacement for adhesives in bond lines to reduce manufacturing time and cost and to promote ease of recyclability. Resistance welding uses an electrically conductive material, such as carbon fiber, embedded in the bond line to heat the joining surfaces and fuse them together under pressure. One main challenge with fusion joining for large wind blades is the ability to use this conductive heating element in the bond line while still protecting the blade from the catastrophic effects of a lightning strike. This paper outlines the design and manufacturing of a lightning protection system for a 5-m-long thermally welded blade tip. The outcomes of high voltage and high current lightning testing applied to the 5 m blade tip show that the proposed design was able to protect the fusion welded bond lines from significant lightning damage.

17 WIND ENERGY↗

Influence of tower shadow on downwind flexible rotors: Field tests and simulations

Abstract As wind turbine rotors become larger, the blades become more flexible, requiring extra stiffness and cost to avoid the risk of tower strike. Wind turbines in a downwind configuration have a reduced risk of tower strike because the rotor thrust acts away from the tower. However, downwind blades pass through the wake of the tower, and the resulting load variation may contribute to blade fatigue. To date, there have been no field tests to quantify this tower shadow effect on unsteady blade moments. The present study reports on the first field testing of a flexible, downwind, coned rotor and compares the experimental data against simulations run in OpenFAST. The tower shadow effect is simulated using the conventional Powles model and a new Eames model (developed herein), which includes the influence of upstream turbulence. Both models reasonably predict the blade root out‐of‐plane bending moment data and the tower shadow dip magnitude when compared to field test data in Region 3. Tower shadow was found to increase the short‐term Damage Equivalent Loads (DELs) by less than 10% compared to other effects (gravity, shear, and turbulence), and the predictions were consistent with experiments. These results indicate that the tower shadow effect can be reasonably modeled with the simpler Powles model and that the tower shadow effect can be small compared to the effect of turbulence. However, long‐term fatigue due to tower shadow should be included in detailed structural analysis and design of the rotor and the tower.

Simpson, Juliet G.↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗

3D printable polymeric lightning strike protection system for fiber reinforced composites

The current embodiments include all-polymeric protective material for mitigating lightning strike damage. The protective material includes a hybrid matrix comprising PANI and MXene dispersed within a thermosetting epoxy resin. This hybrid matrix can be painted, printed, or applied as a conductive polymeric layer to a FRCP structure, for example an aircraft fuselage, wing, empennage, control surface (aileron, flap, slats, rudder, elevator) or a wind turbine blade. The protective material not only withstands lightning strikes, but also functions as shielding against electromagnetic interference and is corrosion-resistant and lightweight.

Kumar, Vipin↗

Field tests of a highly flexible downwind ultralight rotor to mimic a 13-MW turbine rotor

Offshore extreme-scale turbines of 20–25 MW in size may offer reduced energy costs. The technical barriers at these extreme scales include escalating blade masses with increased flexibility as well as high gravity loads and tower-strike issues. These barriers may be addressed with a load-aligning downwind turbine. To investigate this type of design, a field test campaign was conducted with an aeroelastically scaled rotor, termed the Segmented Ultralight Morphing Rotor Demonstrator (SUMR-D). The tests were conducted on the Controls Advanced Research Turbine at the National Renewable Energy Laboratory. The paper gives an overview of the experimental diagnostics, blade design, and results of the field campaign, as well as makes conclusions and recommendations regarding extreme-scale highly flexible downwind rotors.

17 WIND ENERGY↗

Bat Impact Minimization Technology: An Improved Bat Deterrent for the Full Swept Rotor Area of Any Wind Turbine

The growth in the number of wind turbine generators has led to a significant number of fatal interactions with bat species. The need to reduce the number of bat fatalities while minimizing power losses is the greatest conservation challenge for wind energy development in parts of the country, according to the American Wind Wildlife Institute. Technological solutions that can also allow turbines to operate normally would generate the maximum electricity and avoid financial losses. Bats use echolocation to perceive their surroundings by listening to features of echoes from their high frequency vocal signals reflecting from targets. In this project, Frontier Wind built on previous research demonstrating that ultrasonic noise can mask echolocation and act as a repellent or deterrent to bat flight activity. Whereas the initial study only broadcast ultrasonic transmissions from the center of the turbine, the Strike Free™ system developed for this project extended the ultrasonic coverage to the entire area swept by the turbine blades. Frontier Wind designed the system components and their integration and then tested them in the lab and in the field at Pattern Energy’s Hatchet Ridge Wind Facility near Redding, California. The researchers used an acoustic model to determine the optimal configuration of transmitters along the blades to provide sound transmission coverage across the turbine rotor swept area volume. The custom ultrasonic transmitters were designed specifically for the echolocation frequencies of the four main bat species that have been shown to have died at Hatchet Ridge, although the transmitters can be customized for different frequencies as needed in other geographic locations. The Strike Free™ system shows promise for reducing bat fatalities, and the path to commercialization requires further testing to validate and optimize performance in the field.

17 WIND ENERGY↗

Wind Turbine Lightning Mitigation System Radar Cross Section Reduction

Modern wind turbines employ Lightning Mitigation Systems (LMSs) in order to reduce costly damages caused by lightning strikes. Lightning strikes on wind turbines occur frequently making LMS configurations a necessity. An LMS for a single turbine includes, among other equipment, cables running inside each blade, along the entire blade length. These cables are connected to various metallic receptors on the outside surface of the blades. The LMS cables can act as significant electromagnetic scatterers which may cause interference to radar systems. This interference may be mitigated by reducing the Radar Cross-Section (RCS) of the wind turbine's LMS. This report investigates proposed modifications to LMS cables in order to reduce the RCS when illuminated by Re locatable Over the Horizon Radar (ROTHR) systems which operate in the HF band (3 - 30 MHz). The proposed modifications include breaking up the LMS cables using spark gap connections, and changing the orientation of the LMS cable within the turbine blade. Both simulated analyses of such RCS mitigation techniques is provided as well as recommendations on further research.

17 WIND ENERGY↗

Wind Turbine Gust Load Alleviation with Active Flow Control

Large wind turbine rotors are becoming more common in utility-scale wind power, especially for offshore wind plants. However, the trend toward large rotors can be limited by their ability to manage dynamic and extreme loads. To provide a safety margin for the rotor design and avoid catastrophic events such as tower strikes, extreme loads need to be controlled. The objective of this study is to develop and evaluate a feedback control system to alleviate extreme loads and reduce blade deflections under gust events using active flow control devices. We also propose a modification in the turbine controller to achieve further reduction in extreme loads. The extreme load reductions are evaluated under gust wind conditions with direction changes according to the IEC standard. The effects of the gust alleviation controller on turbine performance and fatigue loads are investigated as well. With the deployment of the gust alleviation controller and modified turbine baseline controller, the extreme loads and deflections reduce by up to 23%. The energy captured by the turbine is not affected by the proposed gust alleviation controller. The fatigue loads of various wind turbine components are either reduced or remain unchanged.

17 WIND ENERGY↗

An In-Depth Analysis of the Transformation of Tin Foil Anodes during Electrochemical Cycling in Lithium-Ion Batteries

Tin foils have an impressive lithium-storage capacity more than triple that of graphite anodes, and their adoption could facilitate a drastic improvement in battery energy density. However, implementation of a dense foil electrode architecture represents a significant departure from the standard blade-cast geometry with a distinct electrochemical environment, and this has led to confusion with regards to the first cycle efficiency of the system. In this work, we investigate the unique behavior of a tin active material in a foil architecture to understand its performance as an anode. We find shallow cycling of the foil results in an irreversible formation (< 40%) due to diffusional trapping, but intermediate and complete utilization allows for a remarkably reversible formation reaction (> 90%). This striking nonlinearity stems from an in situ transformation from bulk metal to porous electrode that occurs during formation cycles and defines electrode-level lithium-transport on subsequent cycles. As a result, an alternative cycling procedure for assessing the stability of foils is proposed to account for this chemomechanical effect.

25 ENERGY STORAGE↗

Aerodynamic Rotor Design for a 25 MW Offshore Downwind Turbine

Continuously increasing offshore wind turbine scales require rotor designs that maximize power and performance. Downwind rotors offer advantages in lower mass due to reduced potential for tower strike, and is especially true at large scales, e.g., for a 25 MW turbine. In this study, three 25 MW downwind rotors, each with different prescribed lift coefficient distributions were designed (chord, geometry, and twist) and compared to maximize power production at unprecedented scales and Reynolds numbers, including a new approach to optimize rotor tilt and coning based on aeroelastic effects. To achieve this objective the design process was focused on achieving high power coefficients, while maximizing swept area and minimizing blade mass. Maximizing swept area was achieved by prescribing pre-cone and shaft tilt angles to ensure the aeroelastic orientation when the blades point upwards was nearly vertical at nearly rated conditions. Maximizing the power coefficient was achieved by prescribing axial induction factor and lift coefficient distributions which were then used as inputs for an inverse rotor design tool. The resulting rotors were then simulated to compare performance and subsequently optimized for minimum rotor mass. To achieve these goals, a high Reynolds number design space was developed using computational predictions as well as new empirical correlations for flatback airfoil drag and maximum lift. Within this design space, three rotors of small, medium and large chords were considered for clean airfoil conditions (effects of premature transition were also considered but did not significantly modify the design space). The results indicated that the medium chord design provided the best performance, producing the highest power in Region 2 from simulations while resulting in the lowest rotor mass, both of which support minimum LCOE. The methodology developed herein can be used for the design of other extreme-scale (upwind and downwind) turbines.

downwind rotors↗