Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “biosensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Lunar BioSensor: An Autonomous Instrument to Study the Effects of the Lunar Environment on Biological Organisms

One of the major challenges to long-duration space travel and habitation in deep space is an in-depth understanding of the biological effects of space radiation, often convoluted by the impact of reduced gravity. Nonetheless, due to the near impossibility of simulating prolonged exposure to these combined effects in terrestrial facilities, actual missions are needed to characterize the radiobiological hazards of this environment. NASA Ames has been the leader in developing autonomous bio nanosatellites to address strategic knowledge gaps about the effects of space travel on biological organisms, including GeneSat, PharmaSat, EcAMSat, and BioSentinel. BioSentinel will be the first interplanetary bio nanosatellite or CubeSat to study the biological response to space radiation outside Low Earth Orbit (LEO). BioSentinel is an autonomous platform able to support biology and to investigate the effects of space radiation on a model organism in interplanetary deep space. It will fly onboard NASA’s Artemis-1, from which it will be deployed on a lunar fly-by trajectory and into a heliocentric orbit. The BioSentinel nanosatellite, a 6U deep space CubeSat (1U = 10-cm cube), will measure the DNA damage and response to ambient space radiation in a model biological organism, the budding yeast S. cerevisiae, which will be compared to information provided by an onboard physical radiation sensor and to data obtained in LEO (on the ISS) and on Earth. Even though the primary objective of the mission is to develop an autonomous spacecraft capable of conducting biological experiments in deep space, the 4U BioSensor science payload contained within the 6U free-flyer is an adaptable instrument platform that can perform biological measurements with different microorganisms and in multiple space environments, including the ISS, lunar gateway, and on the surface of the Moon. The proposed 4U instrument will leverage the payload design of the 6U free-flyer, utilizing the lunar lander or vehicle for power and data relay. Thus, nanosatellites like BioSentinel (and Lunar BioSensor) can be used to study the effects of both reduced gravity and space radiation and can house different bio organisms to answer specific science questions. In addition to their flexibility, nanosatellites also provide a low-cost alternative to more complex and larger missions, and require minimal crew support, if any.

space biosensors↗

Space Biology Research and Biosensor Technologies: Past, Present, and Future

In light of future missions beyond low Earth orbit (LEO) and the potential establishment of bases on the Moon and Mars, the effects of the deep space environment on biology need to be examined in order to develop protective countermeasures. Although many biological experiments have been performed in space since the 1960s, most have occurred in LEO and for only short periods of time. These LEO missions have studied many biological phenomena in a variety of model organisms, and have utilized a broad range of technologies. However, given the constraints of the deep space environment, upcoming deep space biological missions will be largely limited to microbial organisms and plant seeds using miniaturized technologies. Small satellites such as CubeSats are capable of querying relevant space environments using novel, miniaturized instruments and biosensors. CubeSats also provide a low-cost alternative to larger, more complex missions, and require minimal crew support, if any. Several have been deployed in LEO, but the next iterations of biological CubeSats will travel beyond LEO. They will utilize biosensors that can better elucidate the effects of the space environment on biology, allowing humanity to return safely to deep space, venturing farther than ever before.

space biology↗

Sensors 2000! Program: Advanced Biosensor and Measurement Systems Technologies for Spaceflight Research and Concurrent, Earth-Based Applications

Sensors 2000! (S2K!) is a specialized, integrated projects team organized to provide focused, directed, advanced biosensor and bioinstrumentation systems technology support to NASA's spaceflight and ground-based research and development programs. Specific technology thrusts include telemetry-based sensor systems, chemical/ biological sensors, medical and physiological sensors, miniaturized instrumentation architectures, and data and signal processing systems. A concurrent objective is to promote the mutual use, application, and transition of developed technology by collaborating in academic-commercial-govemment leveraging, joint research, technology utilization and commercialization, and strategic partnering alliances. Sensors 2000! is organized around three primary program elements: Technology and Product Development, Technology infusion and Applications, and Collaborative Activities. Technology and Product Development involves development and demonstration of biosensor and biotelemetry systems for application to NASA Space Life Sciences Programs; production of fully certified spaceflight hardware and payload elements; and sensor/measurement systems development for NASA research and development activities. Technology Infusion and Applications provides technology and program agent support to identify available and applicable technologies from multiple sources for insertion into NASA's strategic enterprises and initiatives. Collaborative Activities involve leveraging of NASA technologies with those of other government agencies, academia, and industry to concurrently provide technology solutions and products of mutual benefit to participating members.

Hines, J.↗

Demonstration of four immunoassay formats using the array biosensor

The ability of a fluorescence-based array biosensor to measure and quantify the binding of an antigen to an immobilized antibody has been demonstrated using the four different immunoassay formats: direct, competitive, displacement, and sandwich. A patterned array of antibodies specific for 2,4,6-trinitrotoluene (TNT) immobilized onto the surface of a planar waveguide and used to measure signals from different antigen concentrations simultaneously. For direct, competitive, and displacement assays, which are one-step assays, measurements were obtained in real time. Dose-response curves were calculated for all four assay formats, demonstrating the array biosensor's ability to quantify the amount of antigen present in solution.

NASA Discipline Life Sciences Technologies↗

In-line pressure-flow module for in vitro modelling of haemodynamics and biosensor validation

An in-line pressure-flow module for in vitro modelling of haemodynamics and biosensor validation has been developed. Studies show that good accuracy can be achieved in the measurement of pressure and of flow, in steady and pulstile flow systems. The model can be used for development, testing and evaluation of cardiovascular-mechanical-electrical anlogue models, cardiovascular prosthetics (i.e. valves, vascular grafts) and pressure and flow biosensors.

NASA Discipline Cardiopulmonary↗

Progress in Development of Improved Ion-Channel Biosensors

Further improvements have recently been made in the development of the devices described in Improved Ion-Channel Biosensors (NPO-30710), NASA Tech Briefs, Vol. 28, No. 10 (October 2004), page 30. As discussed in more detail in that article, these sensors offer advantages of greater stability, greater lifetime, and individual electrical addressability, relative to prior ion-channel biosensors. In order to give meaning to a brief description of the recent improvements, it is necessary to recapitulate a substantial portion of the text of the cited previous article. The figure depicts one sensor that incorporates the recent improvements, and can be helpful in understanding the recapitulated text, which follows: These sensors are microfabricated from silicon and other materials compatible with silicon. Typically, the sensors are fabricated in arrays in silicon wafers on glass plates. Each sensor in the array can be individually electrically addressed, without interference with its neighbors. Each sensor includes a well covered by a thin layer of silicon nitride, in which is made a pinhole for the formation of a lipid bilayer membrane. In one stage of fabrication, the lower half of the well is filled with agarose, which is allowed to harden. Then the upper half of the well is filled with a liquid electrolyte (which thereafter remains liquid) and a lipid bilayer is painted over the pinhole. The liquid contains a protein that forms an ion channel on top of the hardened agarose. The combination of enclosure in the well and support by the hardened agarose provides the stability needed to keep the membrane functional for times as long as days or even weeks. An electrode above the well, another electrode below the well, and all the materials between the electrodes together constitute a capacitor. What is measured is the capacitive transient current in response to an applied voltage pulse. One notable feature of this sensor, in comparison with prior such sensors, is a relatively thick dielectric layer between the top of the well and the top electrode. This layer greatly reduces the capacitance of an aperture across which the ion channels are formed, thereby increasing the signal-to-noise ratio. The use of a relatively large aperture with agarose support makes it possible to form many ion channels instead of only one, thereby further increasing the signal-to-noise ratio and effectively increasing the size of the available ionic reservoir. The relatively large reservoir makes it possible to measure AC rather than DC. This concludes the recapitulation from the cited previous article.

Nadeau, Jay L.↗

Replaceable Microfluidic Cartridges for a PCR Biosensor

The figure depicts a replaceable microfluidic cartridge that is a component of a miniature biosensor that detects target deoxyribonucleic acid (DNA) sequences. The biosensor utilizes (1) polymerase chain reactions (PCRs) to multiply the amount of DNA to be detected, (2) fluorogenic polynucleotide probe chemicals for labeling the target DNA sequences, and (3) a high-sensitivity epifluorescence-detection optoelectronic subsystem. Microfluidics is a relatively new field of device development in which one applies techniques for fabricating microelectromechanical systems (MEMS) to miniature systems for containing and/or moving fluids. Typically, microfluidic devices are microfabricated, variously, from silicon or polymers. The development of microfluidic devices for applications that involve PCR and fluorescence-based detection of PCR products poses special challenges

Francis, Kevin↗

Identification of Novel Desiccation-Tolerant S. cerevisiae Strains for Deep Space Biosensors

NASA's BioSentinel mission, a secondary payload that will fly on the Space Launch Systems first Exploration Mission (EM-1), utilizes the budding yeast S. cerevisiae to study the biological response to the deep space radiation environment. Yeast samples are desiccated prior to launch to suspend growth and metabolism while the spacecraft travels to its target heliocentric orbit beyond Low Earth Orbit. Each sample is then rehydrated at the desired time points to reactivate the cells. A major risk in this mission is the loss of cell viability that occurs in the recovery period following the desiccation and rehydration process. Cell survival is essential for the detection of the biological response to features in the deep space environment, including ionizing radiation.The aim of this study is to mitigate viable cell loss in future biosensors by identifying mutations and genes that confer tolerance to desiccation stress in rad51, a radiation-sensitive yeast strain. We initiated a screen for desiccation-tolerance after rehydrating cells that were desiccated for three years, and selected various clones exhibiting robust growth. To verify retention of radiation sensitivity in the isolated clonesa crucial feature for a successful biosensorwe exposed them to ionizing radiation. Finally, to elucidate the genetic and molecular bases for observed desiccation-tolerance, we will perform whole-genome sequencing of those rad51 clones that exhibit both robust growth and radiation sensitivity following desiccation. The identification and characterization of desiccation-tolerant strains will allow us to engineer a biological model that will be resilient in face of the challenges of the deep space environment, and will thus ensure the experimental success of future biosensor missions.

S. cerevisiae↗

BioSentinel: Developing a Space Radiation Biosensor

BioSentinel is an autonomous fully self-contained science mission that will conduct the first study of the biological response to space radiation outside low Earth orbit (LEO) in over 40 years. The 4-unit (4U) BioSentinel biosensor system, is housed within a 6-Unit (6U) spacecraft, and uses yeast cells in multiple independent microfluidic cards to detect and measure DNA damage that occurs in response to ambient space radiation. Cell growth and metabolic activity will be measured using a 3-color LED detection system and a metabolic indicator dye with a dedicated thermal control system per fluidic card.

Radiation biosensor↗

Biosentinel: Improving Desiccation Tolerance of Yeast Biosensors for Deep-Space Missions

BioSentinel is one of 13 secondary payloads to be deployed on Exploration Mission 1 (EM-1) in 2019. We will use the budding yeast Saccharomyces cerevisiae as a biosensor to determine how deep-space radiation affects living organisms and to potentially quantify radiation levels through radiation damage analysis. Radiation can damage DNA through double strand breaks (DSBs), which can normally be repaired by homologous recombination. Two yeast strains will be air-dried and stored in microfluidic cards within the payload: a wild-type control strain and a radiation sensitive rad51 mutant that is deficient in DSB repairs. Throughout the mission, the microfluidic cards will be rehydrated with growth medium and an indicator dye. Growth rates of each strain will be measured through LED detection of the reduction of the indicator dye, which correlates with DNA repair and the amount of radiation damage accumulated. Results from BioSentinel will be compared to analog experiments on the ISS and on Earth. It is well known that desiccation can damage yeast cells and decrease viability over time. We performed a screen for desiccation-tolerant rad51 strains. We selected 20 re-isolates of rad51 and ran a weekly screen for desiccation-tolerant mutants for five weeks. Our data shows that viability decreases over time, confirming previous research findings. Isolates L2, L5 and L14 indicate desiccation tolerance and are candidates for whole-genome sequencing. More time is needed to determine whether a specific strain is truly desiccation tolerant. Furthermore, we conducted an intracellular trehalose assay to test how intracellular trehalose concentrations affect or protect the mutant strains against desiccation stress. S. cerevisiae cell and reagent concentrations from a previously established intracellular trehalose protocol did not yield significant absorbance measurements, so we tested varying cell and reagent concentrations and determined proper concentrations for successful protocol use.

BioSentinel↗

Wearable Biosensor Monitor to Support Autonomous Crew Health and Performance

During future human exploration missions, spaceflight crews will encounter adverse health outcomes and decrements in performance during the missions and for long term health. The Psychophysiological Research Lab is currently conducting a technology demonstration of a prototype wearable biosensor system (Astroskin) on astronaut surrogates during 30 day missions within NASAs Human Exploration Research Analog (HERA). HERA, located at Johnson Spaceflight Center, represents a flight analog for simulation of isolation, confinement and remote conditions of mission exploration scenarios. Astroskin, an autonomous medical monitoring system, consists of an intelligent garment for the upper body and a headband fitted with sensors, and associated software and hardware that can measure, transmit and store vital signs (ECG, respiration, blood pressure, etc.), sleep quality and activity level of the wearer. One of the main goals of the technology demonstration is to evaluate the performance of the Astroskin system (i.e., data quality), crew usability and comfort. To validate the Astroskin as a viable option for use during future spaceflight missions, crew data from HERA are sent to Ames researchers for processing and analyses. Crew surveys on usability and comfort will also be evaluated. This work supports the Exploration Medical Capabilities element within NASAs Human Research Program.

space analog↗

BioSentinel/Mars: Interplanetary Space Radiation Biosensor Experiment in Martian Transit on Mars 2020

Despite significant progress understanding biological radiation effects via terrestrial studies, no terrestrial source duplicates space’s unique radiation environment. Furthermore, no biological experiments have been conducted beyond low Earth orbit since Apollo. Understanding space’s fundamental biological effects requires overcoming these limitations. The BioSentinel 4U payload, under development for flight aboard Exploration Mission-1, measures biological responses to deep space radiation. Traveling to more than 1AU from Earth, BioSentinel/EM-1 will record DNA double-strand breaks (DSBs) repaired using a pathway common to humans and BioSentinel’s bioengineered yeast model organism, responding to as few as one biologically repaired DSB. The BioSentinel/Mars 4U instrument (6-8kg; 5-8W; 0.2-1MB/week) would include eighteen 16-well biosensor fluidic cards, activated biweekly during Mars 2020’s cruise phase, to provide a dose-dependent rate of DSB/repair. The instrument, which includes solid-state sensors for total ionizing dose and linear-energy-transfer spectra, addresses MEPAG SKG-B3 by simultaneously measuring both spectra and biological effects of space radiation. Biological measurements are rendered reliable by independent replicate experiments. The spatio-temporal uniformity of interplanetary galactic cosmic radiation makes BioSentinel/EM1 and BioSentinel/Mars approximate replicates, except for any major differences in solar particle events. Results will be compared to Earth and ISS controls to characterize the radiation/reduced-gravity parameter space by its biological impact.

BioSentinel↗

Wearable Biosensor Monitor to Support Autonomous Crew Health and Readiness to Perform

For future human exploration missions, NASA needs a health monitoring system composed of hardware that is compact, fully interoperable with an integrated data management system, and requires minimal consumables. Such a system will be achieved through the integration of small, easy to use biomedical sensors that will have the ability to measure, store and transmit physiological parameters during operational and ambulatory activity. Since 2012, the Canadian Space Agency (CSA) has been active in funding the development of wearable biomonitoring sensors. The Astroskin is the first prototype and consists of a shirt-based garment and headband with embedded sensors, and associated software and technology that measure vital signs, sleep quality and activity level of the wearer. NASA and CSA have been collaborating since 2014 to test and validate this system in a lab environment at Ames Research Center and more recently in the Human Exploration Research Analog (HERA) located at Johnson Spaceflight Center. Specific objectives of the HERA study were: 1) to assess the performance of the Astroskin biosensor system for long-term health monitoring (24-hours) capabilities and during exercise as a measure of crew fitness; 2) to obtain crew feedback on comfort and usability of the Astroskin system; 3) to demonstrate performance of Bluetooth communication during real-time transmission and for verification of data in this environment; and 4) to obtain baseline data for further development of algorithms and tools that facilitate decision support for diagnosing and monitoring of a sick or injured crewmember. HERA Campaign 3 included four missions (each 30-days in duration) with four crewmembers assigned to each mission. A total of 9 men and 7 women participated in the Astroskin evaluation that included continuous physiological monitoring (24-hours) on mission days MD-11, MD1 (high workload), MD15 (low workload), MD19, MD29, and MD+7. Mission days 19 and 29 also included 30 minutes of sub-maximal exercise on a cycle ergometer. Following each 24-hour monitoring session crew physiological data were downloaded to laptops and each crewmember completed a 28 question survey on their experiences with the Astroskin hardware and software. This presentation will focus on lessons learned from the HERA missions. Specifically it will address Astroskin system performance in terms of data loss and data quality (no comparison to lab standard devices), wireless communication with the onboard mobile device, crew usability and comfort, and future development of a next generation biomonitoring system.

crew fitness↗

Yeast Strain Development and Hardware Testing in Preparation of a Lunar BioSensor

With Artemis missions underway, it is clear we are going back to the Moon to stay. Before sending Astronauts for long-duration missions, it is crucial to understand the technological and biomedical countermeasures needed to protect them before they get there. We can use knowledge gained from biological CubeSats to guide the next generation of experiments to support human habitation on the Moon. Lunar Explorer Instrument for space biology Applications (LEIA) is NASA’s latest BioSensor, adapted BioSentinel, the only CubeSat to travel Beyond Low Earth Orbit. BioSentinel launched on Artemis I and is currently >50 million kilometers from Earth (as of July 2024). LEIA aims to identify biological responses to the Lunar environment, which unprotected against would pose a threat to astronauts (cancer, cardiovascular disease, neurological impairment). The suite of instruments within LEIA detects Lunar radiation using two on-board radiation sensors (ARES charged particle detector, Mini-Fast Neutron Detector), then monitors real-time biological responses to the Lunar environment via an autonomous microfluidic system, fit with 3-LED emitter and detector boards and the alamarBlue metabolic indicator dye. LEIA will use a genetic approach in addition to synthetic biology to test counter-measure production in space, with the goal to inform and protect astronauts for future Moon missions. We have conducted preliminary tests in preparation for launch to the anticipated South Pole of the Moon, optimizing the biology (strain down-selection, desiccation tolerance, radiation sensitivity) and improving the hardware (including a blue LED to detect the beta-carotene countermeasure product). Our team will discuss these findings in several parts – an overview of the LEIA mission (Mark Settles), adapting flexible CubeSat platforms for deep-space applications (Sergio Santa Maria, Kira Rienecker), developing new technologies to support LEIA ground studies (Chinmayee Govinda Raj), and yeast strain development and hardware testing in preparation for LEIA (presented here).

synthetic biology↗