Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “biokinetic data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Radiological Toolbox User’s Guide

The Radiological Toolbox software developed by Oak Ridge National Laboratory (ORNL) for U. S. Nuclear Regulatory Commission (NRC) is designed to provide electronic access to the vast and varied data that underlies the field of radiation protection. These data represent physical, chemical, anatomical, physiological, and mathematical parameters detailed in various handbooks which a health physicist might consult while in his office. The initial motivation for the software was to serve the needs of the health physicist away from his office and without access to his handbooks; e.g., NRC inspectors. The earlier releases of the software were widely used and accepted around the world by not only practicing health physicist but also those within educational programs. This release updates the software to accommodate changes in Windows operating systems and, in some aspects, radiation protection. This release has been tested on Windows 7 and 8 and on 32- and 64-bit machines. The nuclear decay data has been updated and thermal neutron capture cross sections and cancer risk coefficients have been included. This document and the software’s user’s guide provide further details and documentation of the information captured within the Radiological Toolbox.

59 BASIC BIOLOGICAL SCIENCES↗

Proposed biokinetic model for phosphorus

This paper reviews data related to the biokinetics of phosphorus in the human body and proposes a biokinetic model for systemic phosphorus for use in updated International Commission on Radiological Protection (ICRP) guidance on occupational intake of radionuclides. Compared with the ICRP s current occupational model for phosphorus (Publication 68, 1994) the proposed model provides a more realistic description of the paths of movement of phosphorus in the body and improved consistency with experimental, medical, and environmental data on the time-dependent distribution and retention of phosphorus following uptake to blood. For acute uptake of 32P to blood, the proposed model yields roughly a 50% decrease in dose estimates for bone surface and red marrow and a 6-fold increase in estimates for liver and kidney compared with the biokinetic model of Publication 68 (applying Publication 68 dosimetric models in both sets of calculations). For acute uptake of 33P to blood, the proposed model yields roughly a 50% increase in dose estimates for bone surface and red marrow and a 7-fold increase in estimates for liver and kidney compared with the model of Publication 68.

60 APPLIED LIFE SCIENCES↗

Biokinetics of 238 Pu oxides: Inferences from bioassay data

The bioassay data collected from several workers involved in 238 Pu inhalation incidents have been analyzed using the most recent biokinetic models described in Occupational Intakes of Radionuclides (OIR) series of publications. Although all exposures were thought to be to 238 Pu oxides, the observed urinary excretion patterns differed in different inhalation incidents. The urinary excretion from individuals involved in one of the incidents increased steadily with time peaking around 2-3 years before decreasing. This pattern is described in Part 4 of the OIR series using the ‘ 238 PuO 2 , ceramic’ model. This non-monotonic behavior, explained as being due to fragmentation and dissolution, was not specific to the incident, but was also observed in other incidents. The urinary excretion data collected from individuals involved in another incident showed dissolution behavior between Type M and Type S. Finally, the bioassay data from yet another incident showed a pattern that appears to represent behavior more insoluble than Type S, which is possibly a result of self-heating due to the decay heat from 238 Pu. The urinary excretion patterns and the corresponding dose coefficients have been calculated and compared.

238Pu↗

A brief overview of compartmental modeling for intake of plutonium via wounds

Here, the aim of this study is to present several approaches that have been used to model the behavior of radioactive materials (specifically Pu) in contaminated wounds. We also review some attempts by the health physics community to validate and revise the National Council on Radiation Protection and Measurements (NCRP) 156 biokinetic model for wounds, and present some general recommendations based on the review. Modeling of intake via the wound pathway is complicated because of a large array of wound characteristics (e.g. solubility and chemistry of the material, type and depth of the tissue injury, anatomical location of injury). Moreover, because a majority of the documented wound cases in humans are medically treated (excised or treated with chelation), the data to develop biokinetic models for unperturbed wound exposures are limited. Since the NCRP wound model was largely developed from animal data, it is important to continue to validate and improve the model using human data whenever plausible.

61 RADIATION PROTECTION AND DOSIMETRY↗

A biokinetic model for systemic nickel

The International Commission on Radiological Protection (ICRP) is updating its suite of reference biokinetic models for internally deposited radionuclides. This paper reviews data for nickel and proposes an updated biokinetic model for systemic (absorbed) nickel in adult humans for use in radiation protection. Compared with the ICRP s current model for nickel, the proposed model is based on a larger set of observations of the behavior of nickel in human subjects and laboratory animals and provides a more realistic description of the paths of movement of nickel in the body. For the two most important radioisotopes of nickel, 59Ni and 63Ni, the proposed model yields substantially lower dose estimates per unit of activity reaching blood than the current ICRP model.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Man-machine analysis of translation and work tasks of Skylab films

An objective approach to determine the concurrent validity of computer-graphic models is real time film analysis. This technique was illustrated through the procedures and results obtained in an evaluation of translation of Skylab mission astronauts. The quantitative analysis was facilitated by the use of an electronic film analyzer, minicomputer, and specifically supportive software. The uses of this technique for human factors research are: (1) validation of theoretical operator models; (2) biokinetic analysis; (3) objective data evaluation; (4) dynamic anthropometry; (5) empirical time-line analysis; and (6) consideration of human variability. Computer assisted techniques for interface design and evaluation have the potential for improving the capability for human factors engineering.

Hosler, W. W.↗

A Generic Biokinetic Model for C-14

The generic biokinetic model currently recommended by the International Commission on Radiological Protection (ICRP) for the treatment of systemic radiocarbon assumes uniform distribution of activity in tissues and a biological half-time of 40 d. This model is intended to generate cautiously high estimates of dose per unit intake of C-14 and, in fact, generally predicts a much higher effective dose than systemic models that have been developed on the basis of biokinetic studies of specific carbon compounds. The simplistic model formulation precludes its application as a bioassay model or adjustment to fit case-specific bioassay data. This paper proposes a new generic biokinetic model for systemic radiocarbon that is less conservative than the current ICRP model but maintains sufficient conservatism to overestimate the effective dose coefficients generated by most radiocarbon-compound-specific models. The proposed model includes two systemic pools with different biological half-times representing an initial systemic form of absorbed radiocarbon, a submodel describing the behaviour of labelled carbon dioxide produced in vivo, and three excretion pathways: breath, urine and faeces. Generic excretion rates along each path are based on multi-phase excretion curves observed in experimental studies of radiocarbons. The generic model structure is designed so that the user may adjust the level of dosimetric conservatism to fit the information at hand and may adjust parameter values for consistency with subject-specific or site-specific bioassay data.

61 RADIATION PROTECTION AND DOSIMETRY↗

IDAC-Bio, A Software for Internal Dosimetry Based on the New ICRP Biokinetic Models and Specific Absorbed Fractions

Radiation dosimetry is central to virtually all radiation safety applications, optimization, and research. It relates to various individuals and population groups and to miscellaneous exposure situations—including planned, existing, and emergency situations. The International Commission on Radiological Protection (ICRP) has developed a new computational framework for internal dose estimations. Important components are more detailed and improved anatomical models and more realistic biokinetic models than before. The ICRP is currently producing new organ dose and effective dose coefficients for occupational intakes of radionuclides (OIR) and environmental intakes of radionuclides (EIR), which supersede the earlier dose coefficients in Publication 68 and the Publication 72 series, respectively. However, the ICRP only publishes dose coefficients for a single acute intake of a radionuclide and for an integration period of 50 years for intake by adults and to age 70 years for intakes by pre-adults. The new software, IDAC-Bio, performs committed absorbed dose and effective dose calculations for a selectable intake scenario, e.g., for a continuous intake or an intake during x hours per day and y days per week, and for any selected integration time. The software uses the primary data and models of the ICRP biokinetic models and numerically solves the biokinetic model and calculates the absorbed doses to organs and tissues in the ICRP reference human phantoms. The software calculates absorbed dose using the nuclear decay data in ICRP publication 107. IDAC-Bio is a further development and an important addition to the internal dosimetry program IDAC-Dose2.1. Here, the results generated by the software were validated against published ICRP dose coefficients. The potential of the software is illustrated by dose calculations for a nuclear power plant worker who had been exposed to varying levels of 60 Co and who had undergone repeated whole-body measurements, and for a hypothetical member of the public subject to future releases of 148 Gd from neutron spallation in tungsten at the European Spallation Source.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of urinary excretion data from three plutonium-contaminated wounds at Los Alamos National Laboratory

The NCRP-156 Report proposes seven different biokinetic models for the wound cases depending on the physicochemistry of the contaminant. Because the models were heavily based on experimental animal data, the authors of the report encouraged application and validation of the models using bioassay data from actual human exposures. Each of the wound models was applied to three plutonium-contaminated wounds, and the models resulted in a good agreement to only one of the cases. We then applied a simpler biokinetic model structure to the bioassay data and showed that fitting the transfer rates from this model structure yielded better agreement with the data than does the best-fitting NCRP-156 model. Because the biokinetics of radioactive material in each wound is different, it is impractical to propose a discrete set of model parameters to describe the biokinetics of radionuclides in all wounds, and thus each wound should be treated empirically.

61 RADIATION PROTECTION AND DOSIMETRY↗

An integrated experimental-computational approach for predicting virulence in New Zealand white rabbits and humans following inhalation exposure to Bacillus anthracis spores

Inhalation of Bacillus anthracis spores can lead to an anthrax infection that can be fatal. Previously published mathematical models have extrapolated kinetic rates associated with bacterial growth in New Zealand White (NZW) rabbits to humans, but to date, actual measurements of the underlying processes associated with anthrax virulence between species have not been conducted. To address this knowledge gap, we have quantified species-specific rate constants associated with germination, proliferation, and immune cell inactivation of B. anthracis Sterne using an in vitro test platform that includes primary lung epithelial and immune cells. The generated data was then used to develop a physiologically based biokinetic model (PBBK) which quantitatively compares bacterial growth and mean time to death under lethal conditions in rabbits and humans. Simulations based upon our in vitro data and previously published in vivo data from rabbits indicate that disease progression is likely to be faster in humans than in NZW rabbits under comparable total deposited dose conditions. With the computational framework established, PBBK parameters can now be refined using experimental data for lethal B. anthracis strains (e.g. Ames) under identical conditions in future studies. The PBBK model can also be linked to existing aerosol dosimetry models that account for species-specific differences in aerosol deposition patterns to further improve the human health risk assessment of inhalation anthrax.

3-D tissue culture, B. anthracis Sterne, biothreat↗

In Vitro Measurements of Metabolism for Application in Pharmacokinetic Modeling

Abstract Human risk and exposure assessments require dosimetry information. Species-specific tissue dose response will be driven by physiological and biochemical processes. While metabolism and pharmacokinetic data are often not available in humans, they are much more available in laboratory animals; metabolic rate constants can be readily derived in vitro. The physiological differences between laboratory animals and humans are known. Biochemical processes, especially metabolism, can be measured in vitro and extrapolated to account for in vivo metabolism through clearance models or when linked to a physiologically based biological (PBPK) model to describe the physiological processes, such as drug delivery to the metabolic organ. This review focuses on the different organ, cellular, and subcellular systems that can be used to measure in vitro metabolic rate constants and how that data is extrapolated to be used in biokinetic modeling.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a New Chelation Model: Bioassay Data Interpretation and Dose Assessment after Plutonium Intake via Wound and Treatment with DTPA

The administration of chelation therapy to treat significant intakes of actinides, such as plutonium, affects the actinide’s normal biokinetics. In particular, it enhances the actinide’s rate of excretion, such that the standard biokinetic models cannot be applied directly to the chelation-affected bioassay data in order to estimate the intake and assess the radiation dose. Here we propose a new chelation model that can be applied to the chelation-affected bioassay data after plutonium intake via wound and treatment with DTPA. In the proposed model, chelation is assumed to occur in the blood, liver, and parts of the skeleton. Ten datasets, consisting of measurements of 14 C-DTPA, 238 Pu, and 239 Pu involving humans given radiolabeled DTPA and humans occupationally exposed to plutonium via wound and treated with chelation therapy, were used for model development. The combined dataset consisted of daily and cumulative excretion (urine and feces), wound counts, measurements of excised tissue, blood, and post-mortem tissue analyses of liver and skeleton. The combined data were simultaneously fit using the chelation model linked with a plutonium systemic model, which was linked to an ad hoc wound model. The proposed chelation model was used for dose assessment of the wound cases used in this study.

60 APPLIED LIFE SCIENCES↗

THE MAYAK WORKER DOSIMETRY SYSTEM (MWDS-2013) FOR INTERNALLY DEPOSITED PLUTONIUM: AN OVERVIEW

The Mayak Worker Dosimetry System (MWDS-2013) is a system for interpreting measurement data from Mayak workers from both internal and external sources. This paper is concerned with the calculation of annual organ doses for Mayak workers exposed to plutonium aerosols, where the measurement data consists mainly of activity of plutonium in urine samples. The system utilises the latest biokinetic and dosimetric models, and unlike its predecessors, takes explicit account of uncertainties in both the measurement data and model parameters. The aim of this paper is to describe the complete MWDS-2013 system (including model parameter values and their uncertainties) and the methodology used (including all the relevant equations) and the assumptions made. Where necessary, supplementary papers which justify specific assumptions are cited.

Bayesian analysis' retrospective dosimetry↗

The effects of chronic diseases on plutonium urinary excretion in former workers of the Mayak Production Association

The radiochemical analysis of plutonium activity in urine is the main method for indirect estimation of doses of internal exposure from plutonium incorporation in professional workers. It was previously shown that late-in-life acute diseases, particularly those that affect the liver, can promote accelerated rates of release of plutonium from the liver with enhanced excretion rates. This initial study examines the relationships of some chronic diseases on plutonium excretion as well as the terminal relative distribution of plutonium between the liver and skeleton. Fourteen cases from former workers at the Mayak Production Association (Mayak PA) who provided from 4–9 urine plutonium bioassays for plutonium, had an autopsy conducted after death, and had sufficient clinical records to document their health status were used in this study. Enhanced plutonium excretion was associated with more serious chronic diseases, including cardiovascular diseases and other diseases that involved the liver. These chronic diseases were also associated with relatively less plutonium found in the liver relative to the skeleton determined by analyses conducted after autopsy. These data further document health conditions that affect plutonium biokinetics and organ deposition and retention patterns and suggest that health status should be considered when conducting plutonium bioassays as these may alter subsequent dosimetry and risk models.

60 APPLIED LIFE SCIENCES↗

A biokinetic model for systemic technetium in adult humans

The International Commission on Radiological Protection (ICRP) currently is updating its biokinetic and dosimetric models for internally deposited radionuclides. Technetium (Tc), the lightest element that exists only in radioactive form, has two important isotopes from the standpoint of potential risk to humans: the long-lived isotope 99 Tm(T 1/2 =2.1x10 5 y) is present in high concentration in nuclear waste, and the short-lived isotope 99m Tc (T 1/2 =6.02 h) is the most commonly used radionuclide in diagnostic nuclear medicine. This paper reviews data on the biological behavior of technetium and proposes a biokinetic model for systemic technetium in the adult human body for use in radiation protection. Compared with the ICRP s current occupational model for systemic technetium, the proposed model provides a more realistic description of the paths of movement of technetium in the body; provides greater consistency with experimental and medical data; and, for most radiosensitive organs, yields substantially different estimates of cumulative activity (total radioactive decays within the organ) following uptake of 99 Tm or 99 mTc to blood.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reconstruction of radionuclide intakes for the residents of East Urals Radioactive Trace (1957–2011)

The East Urals Radioactive Trace (EURT) was formed after a chemical explosion in the radioactive waste-storage facility of the Mayak Production Association in 1957 (Southern Urals, Russia) and resulted in an activity dispersion of 7.4 × 10 16 Bq into the atmosphere. Internal exposure due to ingestion of radionuclides with local foodstuffs was the main factor of public exposure at the EURT. The EURT cohort, combining residents of most contaminated settlements, was formed for epidemiological study at the Urals Research Center for Radiation Medicine, Russia (URCRM). For the purpose of improvement of radionuclide intake estimates for cohort members, the following data sets collected in URCRM were used: (1) Total β-activity and radiochemical measurements of 90 Sr in local foodstuffs over all of the period of interest (1958–2011; n = 2200), which were used for relative 90 Sr intake estimations. (2) 90 Sr measurements in human bones and whole body ( n = 338); these data were used for average 90 Sr intake derivations using an age- and gender-dependent Sr-biokinetic model. Non-strontium radionuclide intakes were evaluated on the basis of 90 Sr intake data and the radionuclide composition of contaminated foodstuffs. Validation of radionuclide intakes during the first years after the accident was first carried out using measurements of the feces β-activity of EURT residents ( n = 148). The comparison of experimental and reconstructed values of feces β-activity shows good agreement. 90 Sr intakes for residents of settlements evacuated 7–14 days after the accident were also obtained from 90 Sr measurements in human bone and whole body. Furthermore, the results of radionuclide intake reconstruction will be used to estimate the internal doses for the members of the EURT cohort.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Age and gender specific biokinetic model for strontium in humans

A biokinetic model for strontium in humans is necessary for quantification of internal doses due to strontium radioisotopes. The ICRP-recommended biokinetic model for strontium has limitation for use in a population study, because it is not gender specific and does not cover all age ranges. The extensive Techa River data set on 90Sr in humans (tens of thousands of measurements) is a unique source of data on long-term strontium retention for men and women of all ages at intake. These, as well as published data, were used for evaluation of age- and gender-specific parameters for a new compartment biokinetic model for strontium (Sr-AGe model). The Sr-AGe model has similar structure as the ICRP model for the alkaline earth elements. The following parameters were mainly reevaluated: gastro-intestinal absorption and parameters related to the processes of bone formation and resorption defining calcium and strontium transfers in skeletal compartments. The Sr-AGe model satisfactorily describes available data sets on strontium retention for different kinds of intake (dietary and intravenous) at different ages (0–80 years old) and demonstrates good agreement with data sets for different ethnic groups. The Sr-AGe model can be used for dose assessment in epidemiological studies of general population exposed to ingested strontium radioisotopes.

age dependence↗

Updated biokinetic model for systemic americium

The biokinetic model for systemic americium (Am) currently recommended by the International Commission on Radiological Protection (ICRP) for application to occupational intake of Am is based on information available through the early 1990s. Much additional information on Am biokinetics has been developed in the past 25 y, including measurements of retention and excretion of 241 Am in many workers with 241 Am burdens and post mortem measurements of 241 Am in tissues of some of those workers. The ICRP's current Am model is reasonably consistent with the updated information, with the main exception that the current model apparently overestimates 24-hour urinary Am as a fraction of skeletal or systemic Am at late times after intake. This paper provides an overview of current information on the systemic kinetics of Am in adult human subjects and laboratory animals and presents an updated biokinetic model for systemic Am that addresses the discrepancies between the current database and current ICRP systemic model for Am. Here, this model is applied in Part 4 (to appear) of an ICRP series of reports on intake of radionuclides by workers called the OIR (Occupational Intake of Radionuclides) series.

61 RADIATION PROTECTION AND DOSIMETRY↗