SEARCH · Engineering Papers
Results for “bifacial PV modules”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Field Study of Nighttime Leakage Current in Bifacial PV modules: Correlation with Atmospheric Electric Field data
We demonstrate a charges transfer from the atmosphere to the modules’ frame in the field and discuss the mechanism - leakage current measured in the field are not only related to the PV module operation - this is crucial to consider in potential-induced degradation modeling
Spectral Effects in Albedo and Rearside Irradiance Measurment for Bifacial Performance Estimation: Preprint
Albedo data are essential for accurate prediction of bifacial PV module performance. However, spectral response mismatch between PV modules and irradiance sensors used in albedometers can limit the accuracy of performance predictions. In order to provide quantitative assessment of this effect, we investigate via simulation the differences in spectrally responsive albedo measured with thermopile pyranometers and crystallinesilicon PV reference cells in comparison to a representative crystalline-silicon bifacial PV module for nine different representative ground surface materials. Calculations are performed using simulated solar spectra together with catalogued spectral reflectivity data distributed with the SMARTS simulation software. For the specific materials considered, the results show that albedo measurement using thermopile pyranometers could over or under-estimate the ground-reflected radiation usable by a bifacial PV module by up to 10%, versus only approximately 4% total range of variation for a PV reference cell.
Evaluation of Bifacial Modules and PV Technologies with Combined-Accelerated Stress Testing
In view of the increasing interest and market share of bifacial cells and modules, suitable substrates such as glass and transparent backsheets along with ethylene vinyl acetate (EVA) and polyolefin elastomer (POE) encapsulants were examined in combined-accelerated stress testing (C-AST) to evaluate and compare degradation modes. Testing with both monofacial and bifacial cells, we found glass-glass modules with monofacial cells led to greater grid finger breakage than those with polymeric backsheets. This is attributed to previous x-ray topography work showing higher stress in cells in glass-glass modules than glass backsheet modules. Consistent with the objectives of C-AST, which stresses modules at levels corresponding to the limits seen in the natural environment, we observed the UV-fluorescence signatures of modules tested in C-AST (considering the degradation associated with developing chromophores, moisture penetration and photobleaching effects) to be like those in fielded modules, more so than other chamber stress testing implemented for comparison. Finally, among multiple cell degradation modes that we observed such as light-induced degradation (LID), we differentiated susceptibility to potential-induced degradation (PID) on the back of the bifacial Passivated Emitter Back Cells (PERC) in C-AST. Confirming with ex-situ tests, we found polarization-type PID most prevalent in glass/glass modules with EVA as would be anticipated considering the greater leakage current through such module encapsulation. Unlike PID tests performed in the dark, which can lead to false positive PID test results, field-representative illumination is experienced by the modules on the front and back side while -1200 V system voltage is applied in C-AST, supporting the conclusion that this module type would be susceptible to PID in the field.
Presenting a Model to Predict Changing Snow Albedo for Improving Photovoltaic Performance Simulation
As photovoltaic (PV) deployment increases worldwide, PV systems are being installed more frequently in locations that experience snow cover. The higher albedo of snow, relative to the ground, increases the performance of PV systems in northern and high-altitude locations by reflecting more light onto the PV modules. Accurate modeling of the snow’s albedo can improve estimates of PV system production. Typical modeling of snow albedo uses a simple two-value model that sets the albedo high when snow is present, and low when snow is not present. However, snow albedo changes over time as snow settles and melts and a binary model does not account for transitional changes, which can be significant. Here, we present and validate a model for estimating snow albedo as it changes over time. The model is simple enough to only require daily snow depth and hourly average temperature data, but can be improved through the addition of site-specific factors, when available. We validate this model to quantify its ability to more accurately predict snow albedo and compare the model’s performance against satellite imagery-based methods for obtaining historical albedo data. In addition, we perform modeling using the System Advisor Model (SAM) to show the impact of changes in albedo on energy modeling for PV systems. Overall, our albedo model has a significantly improved ability to predict the solar insolation on PV modules in real time, especially on bifacial PV modules where reflected irradiance plays a larger role in energy production.
Susceptibility to polarization type potential induced degradation in commercial bifacial p-PERC PV modules
Potential induced degradation (PID) is a reliability issue affecting photovoltaic (PV) modules, mainly when PV strings operate under high voltages in hot/humid conditions. Polarization-type PID (PID-p) has been known to decrease module performance quickly. PID-p can be reduced or recovered under the light in some cases, but this effect, as expected, would be less pronounced on the rear side of bifacial PV modules receiving lower irradiance. As bifacial PV modules are projected to dominate the PV market within the next 10 years, it is crucial to understand the PID-p issue in bifacial modules better. In this study, we performed indoor PID testing to induce PID-p on 14 commercial bifacial p-PERC modules with three different module constructions from three manufacturers. Here, four rounds (+ve and –ve polarities for front and rear sides) of PID testing are done at 25°C, 54% relative humidity (RH) for 168 h using the aluminum foil method. Each module side (front cell side and back cell side) is tested individually under both negative and positive voltage bias. The results show that the highest degradation of 32% in maximum power (Pmax) at standard test conditions (1000 W/m 2 ) and 51% at low irradiance (200 W/m 2 ) has been observed in some cases. Recovery under sunlight is also done, and outcomes show a near-complete recovery in Pmax. This study presents an extensive experimental methodology and a detailed analysis to systematically and simultaneously/sequentially evaluate multiple construction types of bifacial modules to the PID-p susceptibility and recovery.
Effect of Torque-Tube Parameters on Rear-Irradiance and Rear-Shading Loss for Bifacial PV Performance on Single-Axis Tracking Systems
The emergence of cost-competitive bifacial PV modules has raised the question of the additional value of bifacial 1-axis tracking arrays, in particular when considering rear-irradiance losses from the tracker system itself. In this work, the effect of different geometries and materials of torque tubes is evaluated through ray-trace simulations and found to cause rear irradiance shading factors between 2% to 8% for systems without gap between the modules in 2-UP configuration. Inclusion of a gap between the modules can offset the shading factor. Electrical mismatch is also evaluated for the various configurations, and a methodology to apply shading factor and electrical mismatch loss to rear irradiance from the calculated loss in DC power, which averages 1% for the systems explored here, is proposed.
Effect of Torque-Tube Parameters on Rear-Irradiance and Rear-Shading Loss for Bifacial PV Performance on Single-Axis Tracking Systems: Preprint
The emergence of cost-competitive bifacial PV modules has raised the question of the additional value of bifacial modules in 1-axis tracking arrays, in particular when considering rear-irradiance losses from the tracker system itself. In this work, the effect of different geometries and materials of torque tubes is evaluated and found to reduce rear-irradiance averages without any torque-tube shading by 0.1 to 12% for metallic and black absorptive torque tubes respectively for a clear-sky day. This paper will compare modeled to measured rear-irradiance profiles, and propose a recommended range of rear-shading loss factors for different geometry conditions. The effect of rear-irradiance distribution into electrical mismatch loss will also be explored.
Effect of Torque-Tube Parameters on Rear-Irradiance and Rear-Shading Loss for Bifacial PV Performance on 1-Axis Tracking Systems
The emergence of cost-competitive bifacial PV modules has raised the question of the additional value of bifacial modules in 1-axis tracking arrays, in particular when considering rear-irradiance losses from the tracker system itself. In this work, the effect of different geometries and materials of torque tubes is evaluated and found to reduce rear-irradiance averages without any torque-tube shading by 0.1 to 12% for metallic and black absorptive torque tubes respectively for a clear-sky day. This paper will compare modeled to measured rear-irradiance profiles, and propose a recommended range of rear-shading loss factors for different geometry conditions. The effect of rear-irradiance distribution into electrical mismatch loss will also be explored. shading by 0.1 to 12% for metallic and black absorptive torque tubes respectively for a clear-sky day. This paper will compare modeled to measured rear-irradiance profiles, and propose a recommended range of rear-shading loss factors for different geometry conditions. The effect of rear-irradiance distribution into electrical mismatch loss will also be explored.
The 1st International Round-Robin on Bi-Facial Modules
This presentation discusses validation of methods and ensuring the validity of results when testing bifacial PV modules, both of which are requirements in ISO/IEC 17025:2017; electrical parameters to be reported per IEC TS 60904-1-2; and statistical design proficiency testing per ISO 17043.
bifacial_radiance: a python package for modeling bifacial solar photovoltaic systems
bifacial_radiance is a national-laboratory-developed, community-supported, open-source toolkit that provides a set of functions and classes for simulating the performance of bifacial photovoltaic (PV) systems. (Bifacial PV modules collect light on the front as well as the rear side.) bifacial_radiance automates calculations of PV system layout and performance to use along with the popular ray-tracing software tool RADIANCE (Ward, 1994). Specific algorithms include design and layout of PV modules, reflective ground surfaces, shading obstructions, and irradiance calculations throughout the system, among others. bifacial_radiance is an important component of a growing ecosystem of open-source tools for solar energy (William F Holmgren et al., 2018).
Albedo Data to Facilitate Bifacial PV System Planning
For mono-facial photovoltaic (PV) systems, the ground-reflected radiation typically comprises only 1% to 2% of the total radiation received by the PV module. Consequently, a rudimentary understanding of the ground albedo is adequate for predicting their performance. However, for bifacial PV modules where their benefit is determined by the additional radiation reflected by the ground to their backside, a better understanding of albedo values and characteristics is needed by both the PV and financial communities to better estimate performance and to reduce risk. This was identified as a key need at the 2018 Bifacial PV Workshop. Subsequently, the Department of Energy (DOE) has initiated work with the National Renewable Energy Laboratory (NREL) to provide albedo data for different locations and ground surfaces for both the simulation of bifacial PV systems and for summary information, including variations in albedo with respect to time of day, season, and year. This albedo data base will include data from measurement networks (SURFRAD and Ameriflux), and the PV industry is also asked to provide their albedo measurements and take part in a cooperative effort to provide an expansive and accurate data base of albedo values.
Glass/glass photovoltaic module reliability and degradation: a review
Glass/glass (G/G) photovoltaic (PV) module construction is quickly rising in popularity due to increased demand for bifacial PV modules, with additional applications for thin-film and building-integrated PV technologies. G/G modules are expected to withstand harsh environmental conditions and extend the installed module lifespan to greater than 30 years compared to conventional glass/backsheet (G/B) modules. With the rapid growth of G/G deployment, understanding the outdoor performance, degradation, and reliability of this PV module construction becomes highly valuable. In this review, we present the history of G/G modules that have existed in the field for the past 20 years, their subsequent reliability issues under different climates, and methods for accelerated testing and characterization of both cells and packaging materials. We highlight some general trends of G/G modules, such as greater degradation when using poly(ethylene-co-vinyl acetate) (EVA) encapsulants, causing the industry to move toward polyolefin-based encapsulants. Transparent backsheets have also been introduced as an alternative to the rear glass for decreasing the module weight and aiding the effusion of trapped gaseous degradation products in the laminate. New amendments to IEC 61215 standard protocols for G/G bifacial modules have also been proposed so that the rear side power generation and UV exposure will be standardized. We further summarize a suite of destructive and non-destructive characterization techniques, such as current-voltage scans, module electro-optical imaging, adhesion tests, nanoscale structural/chemical investigation, and forensic analysis, to provide deeper insights into the fundamental properties of the module materials degradation and how it can be monitored in the G/G construction. This will set the groundwork for future research and product development.
Glass/Glass Photovoltaic Module Reliability and Degradation: A Review - Figures
Glass/glass (G/G) photovoltaic (PV) module construction is quickly rising in popularity due to increased demand for bifacial PV modules, with additional applications for thin-film and building-integrated PV technologies. G/G modules are expected to withstand harsh environmental conditions and extend the installed module lifespan to greater than 30 years compared to conventional glass/backsheet (G/B) modules. With the rapid growth of G/G deployment, understanding the outdoor performance, degradation, and reliability of this PV module construction becomes highly valuable. In this review, we present the history of G/G modules that have existed in the field for the past 20 years, their subsequent reliability issues under different climates, and methods for accelerated testing and characterization of both cells and packaging materials. We highlight some general trends of G/G modules, such as greater degradation when using poly(ethylene-co-vinyl acetate) (EVA) encapsulants, causing the industry to move toward polyolefin-based encapsulants. Transparent backsheets have also been introduced as an alternative to the rear glass for decreasing the module weight and aiding the effusion of trapped gaseous degradation products in the laminate. New amendments to IEC 61215 standard protocols for G/G bifacial modules have also been proposed so that the rear side power generation and UV exposure will be standardized. We further summarize a suite of destructive and non-destructive characterization techniques, such as current-voltage scans, module electro-optical imaging, adhesion tests, nanoscale structural/chemical investigation, and forensic analysis, to provide deeper insights into the fundamental properties of the module materials degradation and how it can be monitored in the G/G construction. This will set the groundwork for future research and product development.
Albedo Data for Bifacial PV Systems
At the September 2018 Bifacial PV Workshop in Lakewood, CO, a better understanding of albedo values and characteristics was identified as a key need by both the PV and financial communities to better estimate performance and to reduce risk of bifacial PV systems. To meet this need, the U.S. Department of Energy (DOE) has initiated work with the National Renewable Energy Laboratory (NREL) to provide the following: A multi-year database of measured and quality assessed albedo values with temporal resolution of one hour or less for numerous locations and types of ground surfaces. Site metadata for each location (Pictures, instruments and calibration history, soil and vegetation types, etc.) Site albedo statistics for each location (diurnal profiles, monthly and annual means, interannual variability) Analysis of the spectral mismatch for bifacial PV modules of the ground-reflected radiation for anticipated deployment surfaces (using both measured and modeled spectral albedo data). Comparisons of the measured albedos with available satellite-derived MODIS albedo products to validate the MODIS albedo products for estimating bifacial PV system performance.
bifacialVF - Bifacial PV View Factor model [SWR 17-58]
bifacialvf is a self-contained view factor (or configuration factor) model which replicates a 5-row PV system of infinite extent perpendicular to the module rows. Single-axis tracking is supported, and hourly output files based on TMY inputs are saved. Spatial nonuniformity is reported, with multiple rear-facing irradiances collected on the back of each module row. Bilinear interpolation code add-on to bifacialvf (description below) to pre-generate IV arrays and bifacial coefficients, and to examine the energy production with back side irradiance mismatch for either a portrait or landscape module. Included are IV curves and bifacial info for a Yingli (standard) module. Based on the publication: "A Practical Irradiance Model for Bifacial PV Modules" B. Marion, S. MacAlpine, C. Deline, A. Asgharzadeh, F. Toor, D. Riley, J. Stein, C. Hansen 2017 IEEE Photovoltaic Specialists Conference, Washington DC, 2017 URL: https://www.nrel.gov/docs/fy17osti/67847.pdf