First study of Hohlraum x-ray preheat asymmetry inside an ICF capsule

In indirect drive inertial confinement fusion (ICF), laser induced Hohlraum preheat radiation (so-called M-band, >1.8 keV) asymmetry will lead to asymmetric ablation front and ablator–fuel interface hydrodynamic instability growth in an imploding capsule. First experiments to infer the M-band asymmetries at the capsule were performed on the National Ignition Facility for high density carbon (HDC) ICF capsules in low density fill (0.3 mg/cc 4 He) Au Hohlraums by time resolved imaging of 2.3 keV fluorescence emission of a smaller Mo sphere placed inside the capsule. In this study, the measured Mo emission is pole hot (P 2 > 0) since M-band is generated mainly by the outer laser beams as their irradiance at the Hohlraum wall is 5× higher than for the inner beams. P 2 has a greater negative than positive swing vs time [Δ(P 2 /P 0 )/Δt ~ 0.2/ns], giving insight into laser heated Hohlraum dynamics. P 4 asymmetry is small at the sphere due to efficient geometric smoothing of Hohlraum asymmetries at large Hohlraum -to-capsule ratios. The M-band P 2 history is qualitatively reproduced by radiation hydrodynamic HYDRA simulations. The smaller P 2 than that calculated earlier suggests either less outer beam spot motion and/or preheat emission. At late times, the observed P 2 swing is larger and P 4 is more negative than simulated, which could be due to inner beams being stopped more in the outer beams wall plasma bubble than simulated. Asymmetry at the HDC capsule inner surface (“ice–ablator interface”) is also inferred from the Mo emission asymmetry by an analytic viewfactor model, accounting for the Mo/HDC radius difference and HDC capsule opacity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gas Stopper Developments for Improved Purity and Intensity of Low-Energy, Rare Isotope Ion Beams (Final Technical Report)

This final technical report summarizes the work of the Michigan State University (MSU) team supported by grant # DE-SC0021423 awarded by the Office of Nuclear Physics, Department of Energy. Objectives: The successful fulfillment of the FRIB science mission hinges on ensuring the availability of fast, stopped, and reaccelerated beams consisting of rare isotopes. This project's research and development focus was dedicated to supporting the advancement and creation of a cutting-edge linear gas stopper. The primary aim is to efficiently convert the high-intensity fast beams of rare isotopes provided by FRIB into high-quality, low-energy beams. These beams are essential for conducting stopped beam experiments or for subsequent reacceleration. The overarching goal is to advance technology, aiming to increase the beam rate capability of the linear gas stopper for medium-to-heavy-mass rare isotopes by more than tenfold compared to the currently most effective gas stopper in operation, and to improve the purity of the delivered beams. Project Description: The existing technology employed in gas stopping devices designed for low-energy, rare-isotope beams presents limitations in both the purity of extracted beams and the intensities of injected beams. These limitations are incompatible with the requirements of the recently commissioned rare isotope beam facility, FRIB. Our research and development efforts, aligned with the previously outlined objectives, focused on addressing the most critical aspects for enhancing beam-rate capability and purity. Specifically, advanced particle-in-cell simulations were developed and integrated into a simulation pipeline to explore the efficacy of multi-layer RF carpets on increasing ion transport efficiency with high incoming beam rates that generate space charge fields which can limit it. We also explored the possibility of using a collision-induced-dissociation (CID) gas cell to break up molecular contaminant ions that are generated during the stopping process. A prototype CID gas cell was constructed and tested with beams from an offline ion source, validating the concept with the successful demonstration of breaking of molecular ions. The outcome of this research enabled the formulation a conceptual design for a next-generation linear gas stopping device specifically tailored for FRIB. This device is envisioned to deliver rare-isotope-ion beams at a rate of 10 8 particles per second or higher, accompanied by advancements in purity. Methods employed: This project leverages advancements in technologies initially designed for the Advanced Cryogenic Gas Stopper (ACGS), the current state-of-the-art linear gas stopper, through the use of new simulations and beam purification via collision-induced-dissociation. The methods include: 1. Development of a prototype low-energy, low-pressure CID gas stopper. This prototype features a thin, approximately 20 nm, Si 3 N 4 entrance window designed for dissociating stable and rare-isotope molecular ions. The goal is to enhance beam purification and overall efficiency. 2. Creation of Particle-in-cell (PIC) simulations to assess the advantages of multi-layer RF carpets and multi-point extraction for ion transport efficiency. These simulations rely on the 3DCylPIC package, specifically designed for studying devices of this nature. The goal is to quantify and mitigate ion transport losses due to space charge generated in the stopping process of large numbers of ions. 3. Perform ion transport simulations across an RF carpet using an 8-phase travelling wave and evaluate its performance. Compared to the 4-phase RF carpets used in ACGS, the 8-phase carpets will double the wavelength of the generated traveling wave allowing for larger maximum RF amplitudes that could result in improved ion transport efficiency for high-intensity incoming beams when large space charge fields are present. Impact: Tackling the primary challenges associated with transforming high-energy projectile fragment beams into low-energy beams—specifically, addressing efficiency and purity—holds significant promise for advancing FRIB science. This advancement will particularly impact precision mass measurements, laser spectroscopy of short-lived nuclei, and studies in astrophysics and nuclear reactions using reaccelerated beams. These domains play a crucial role in addressing key questions outlined in the 2023 NSAC long-range plan, spanning nuclear structure, nuclear astrophysics, and fundamental symmetries. Additionally, they contribute to addressing 10 out of the 17 benchmarks identified by the NRC RISAC. The development of a next-generation gas stopping device capable of delivering low-energy, rare-isotope beams at a rate of 10 8 particles per second, or more, with high purity holds the potential to unlock experiments that would otherwise be unfeasible. Furthermore, it is expected to reduce the time required for experiments at FRIB, thereby maximizing scientific output. The research and development activities performed as part of this project bolstered essential competencies at FRIB in beam physics and ion source technologies, provided valuable training opportunities for junior scientists.

43 PARTICLE ACCELERATORS↗

Heating and ionization of stellar chromospheres by nonthermal proton beams: Implications for impulsive phase, redshifted Lyman-alpha radiation in stellar flares

We investigate the physical basis for the timescale of impulsive-phase, redshifted Lyman-alpha emission in stellar flares on the assumption that it is determined by energy losses in a nonthermal proton beam that is penetrating the chromosphere from above. The temporal evolution of ionization and heating in representative model chromospheres subjected to such beams is calculated. The treatment of 'stopping' of beam protons takes into account their interactions with (1) electrons bound in neutral hydrogen, (2) nuclei of neutral hydrogen, (3) free electrons, and (4) ambient thermal protons. We find that, for constant incident beam flux, the system attains an equilibrium with the beam energy input to the chromosphere balanced by radiative losses. In equilibrium, the beam penetration depth is constant, and erosion of the chromosphere ceases. If the redshifted, impulsive-phase stellar flare Lyman-alpha emission is produced by downstreaming hydrogen formed through charge exchange between beam protons and ambient hydrogen, then the emission should end when the beam no longer reaches neutral hydrogen. The durations of representative emission events calculated on this assumption range from 0.1 to 14 s. The stronger the beam, the shorter the timescale over which the redshifted Lyman-alpha emission can be observed.

Brosius, Jeffrey W.↗

Gas stopping and reacceleration techniques at the Facility for Rare Isotope Beams (FRIB)

The Facility for Rare Isotope Beams (FRIB) at Michigan State University provides a wide range of beams and energies for science with fast, stopped and reaccelerated rare-isotope beams. FRIB was commissioned in 2022 with the science program beginning in May 2022. Here, the combination of fast beams followed by gas stopping of rare-isotope beams together with reacceleration is unique to FRIB. Stopping techniques and beam manipulation at very-low energies are important to slow down fast beams for use in either stopped-beam experimental devices, or subsequent injection in the reaccelerator for experiments at energies ranging from 0.3 MeV/u to 12 MeV/u, depending on the Q/A of the ion. Innovative stopped-beam techniques to optimize the stopping and extraction efficiencies across a wide range of atomic numbers, as well as to reduce contamination and increase extraction speed, were developed. Reacceleration of those beams involve cooling, bunching, charge breeding and acceleration by a state-of-the-art superconducting reaccelerator, ReA. In this contribution we present the latest results of various gas stoppers and techniques to eliminate contaminants after reacceleration by the ReA.

43 PARTICLE ACCELERATORS↗

Laser-Beam Separator

Train of prisms and optical stop separate fundamental beam of laser from second and higher order harmonics of beam produced in certain crystals and by stimulated Raman scattering in gases and liquids.

Mcdermid, I. S.↗

Effects of argon ion injections in the plasmasphere

In lifting massive space power system payloads from low Earth orbit to geosynchronous Earth orbit, Cargo Orbit Transfer (COTV) using ion propulsion will inject energetic beams of argon ions into the plasmasphere. The relationship of the beam velocity to Alfven and thermal velocities as a function of radial distance in the plasmasphere is given for positions near the Earth's equatorial plane. A beam sheath loss model is used which results in a deposition of argon ions and hence energy in the plasmasphere which is much less than that in models calling for clouds or plasma instabilities to rapidly stop the beam. A comparison is given of the cumulative fractional mass loss of an ion beam injected at 1.5 R for the ion cloud and the ion beam sheath loss process. The integrated difference of these two deposition models is shown for the construction of one SPS.

Curtis, S. A.↗

A high-voltage MR-ToF mass spectrometer and separator for the study of exotic isotopes at FRIB

The Facility for Rare Isotope Beams (FRIB) delivers a wide variety of rare isotopes as fast, stopped, or reaccelerated beams to enable forefront research in nuclear structure, astrophysics, and fundamental interactions. To expand the scientific potential of FRIB’s stopped and reaccelerated beam programs, we are designing a Multi-Reflection Time-of-Flight mass spectrometer and separator (MR-ToF MS). It will enable high-precision mass measurements of short-lived isotopes, improve beam diagnostics, and deliver isobarically and isomerically purified beams to downstream experimental stations. It is designed to store ions at a kinetic energy of 30 keV, significantly enhancing ion throughput while maintaining high mass resolving power. In conclusion, we present the scientific motivation, technical design, and simulations demonstrating the expected performance of the system, which has the potential to significantly enhance FRIB’s mass measurement, diagnostic, and mass separation capabilities.

Electrostatic ion beam trap↗

Solar flare model atmospheres

Solar flare model atmospheres computed under the assumption of energetic equilibrium in the chromosphere are presented. The models use a static, one-dimensional plane-parallel geometry and are designed within a physically self-consistent coronal loop. Assumed flare heating mechanisms include collisions from a flux of nonthermal electrons and X-ray heating of the chromosphere by the corona. The heating by energetic electrons accounts explicitly for variations of the ionized fraction with depth in the atmosphere. X-ray heating of the chromosphere by the corona incorporates a flare loop geometry by approximating distant portions of the loop with a series of point sources, while treating the loop leg closest to the chromospheric footpoint in the plane-parallel approximation. Coronal flare heating leads to increased heat conduction, chromospheric evaporation and subsequent changes in coronal pressure; these effects are included self-consistently in the models. Cooling in the chromosphere is computed in detail for the important optically thick H I, Ca II and Mg II transitions using the non-local thermodynamic equilibrium (non-LTE) prescription in the program MULTI. Hydrogen ionization rates from X-ray photoionization and collisional ionization by nonthermal electrons are included explicitly in the rate equations. The models are computed in the 'impulsive' and 'equilibrium' limits, and in a set of intermediate 'evolving' states. The impulsive atmospheres have the density distribution frozen in the pre-flare configuration, while the equilibrium models assume the entire atmosphere is in hydrostatic and energetic equilibrium. The evolving atmospheres represent intermediate stages where hydrostatic equilibrium has been established in the chromosphere and corona, but the corona is not yet in energetic equilibrium with the flare heating source. Thus, for example, chromospheric evaporation is still in the process of occurring. We have computed the chromospheric radiation that results from a range of coronal heating rates, with particular emphasis on the widely observed diagnostic H(alpha). Our conclusion is that the H(alpha) fluxes and profiles actually observed in flares can only be produced under conditions of a low-pressure corona with strong beam heating. Therefore we suggest that H(alpha) in flares is produced primarily at the footprints of newly heated loops where significant evaporation has not yet occurred. As a single loop evolves in time, no matter how strong the heating rate may become, the H(alpha) flux will diminish as the corona becomes denser and hence more effective at stopping the beam. This prediction leads to several observable consequences regarding the spatial and temporal signatures of the X-ray and H(alpha) radiation during flares.

Hawley, Suzanne L.↗

Solid-phase isotope harvesting of 88 Zr from a radioactive ion beam facility

During routine operation of the Facility for Rare Isotope Beams (FRIB), radionuclides will accumulate in both the aqueous beam dump and along the beamline in the process of beam purification. These byproduct radionuclides, many of which are far from stability, can be collected and purified for use in other scientific applications in a process called isotope harvesting. In this work, the viability of 88 Zr harvesting from solid components was investigated at the National Superconducting Cyclotron Laboratory. A secondary 88 Zr beam was stopped in a series of collectors comprised of Al, Cu, W, and Au foils. Here, this work details irradiation of the collector foils and the subsequent radiochemical processing to isolate the deposited 88 Zr (and its daughter 88 Y) from them. Total average recovery from the Al, Cu, and Au collector foils was (91.3 ± 8.9) % for 88 Zr and (95.0 ± 5.8) % for 88 Y, respectively, which is over three times higher recovery than in a previous aqueous-phase harvesting experiment. The utility of solid-phase isotope harvesting to access elements such as Zr that readily hydrolyze in near-neutral pH aqueous conditions has been demonstrated for application to harvesting from solid components at FRIB.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Wire-coil insert optimization for high-heat-load/flux synchrotron components

Many synchrotron components require high levels of internal-flow, forced-convection heat transfer to minimize surface temperatures, thermal gradients, and thermally induced stress on high-power beam-interacting surfaces. Wire-coil inserts, physically similar to a common spring, are mechanically fitted inside of component cooling passages to optimize heat transfer performance. They are routinely used in Advanced Photon Source (APS) front end and beamline high-heat-load/flux components to significantly enhance convection heat transfer-up to 400% compared to plain open passages. This has the additional benefit of greatly reducing coolant flow requirements for these components. Using several cooling passage sizes, five different wire sizes, and a range of pitch values, an experimental investigation conducted at the APS has determined the average heat transfer coefficient and resulting pressure loss as a function of water flow rate for 65 different wire-coil inserts. Data from this study have been non-dimensionalized and generalized to yield relationships that can be used to determine the heat transfer performance and resulting pressure loss for any given wire-coil insert that may be used at the APS. Through data reduction, the wire-coil insert characteristic dimensions have also been optimized to yield the highest heat transfer enhancement while minimizing the coolant flow requirements. These generalized expressions for wirecoil inserts will be presented, and they can be used by scientists and engineers during the component design process to evaluate achievable heat transfer performance and associated pressure loss, aiding in the establishment of optimized operating parameters and cooling passage flow distribution schemes.

43 PARTICLE ACCELERATORS↗

The MU2E Experiment at FERMILAB: R&D, Design and Status

The Mu2e Experiment at Fermilab 1) will search for coherent, neutrinoless conversion of negative muons into electrons in the field of an aluminum nucleus, µ - + N (A, Z) → e - + N (A, Z). This is an example of Charged Lepton Flavour Violation (CLFV) never observed experimentally. The dynamics of such a process is well modelled by a two-body decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass (~104.967 MeV). If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between conversion and capture rate R µe ≤ 6 × 10 -17 (@ 90% C.L.). This will improve the current limit of a factor of 10 4 over previous experiments. The experiment complements and extends the current/planned searches (µ → eγdecay at MEG , mu3e) as well as the direct searches for new physics at the LHC. Indeed, such CLFV searches in the muon sector probe new physics at a mass scale inaccessible with direct searches at either present or planned high-energy colliders. To detect the muon conversion process, a very intense pulsed beam of negative muons is produced by means of a S-shape Superconducting Solenoid Magnet System that is organized into three subsystems: the Production Solenoid, the Transport Solenoid and the Detector Solenoid. The beam is stopped at 10 GHz on an Aluminum target inside the Detector Solenoid. The Mu2e detectors, also installed inside the Detector Solenoid, are a high-precision tracker made on ~20000 straw tubes, and a calorimeter composed of ~1500 pure CsI crystals organized in two disks and readout by two large area UV-extended Silicon Photomultipliers (SiPMs). The Detector Solenoid region is surrounded by a Cosmic Ray Veto based on scintillators readout by SiPMs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thorium-uranium fission radiography

Results are described for studies designed to develop routine methods for in-situ measurement of the abundance of Th and U on a microscale in heterogeneous samples, especially rocks, using the secondary high-energy neutron flux developed when the 650 MeV proton beam of an accelerator is stopped in a 42 x 42 cm diam Cu cylinder. Irradiations were performed at three different locations in a rabbit tube in the beam stop area, and thick metal foils of Bi, Th, and natural U as well as polished silicate glasses of known U and Th contents were used as targets and were placed in contact with mica which served as a fission track detector. In many cases both bare and Cd-covered detectors were exposed. The exposed mica samples were etched in 48% HF and the fission tracks counted by conventional transmitted light microscopy. Relative fission cross sections are examined, along with absolute Th track production rates, interaction tracks, and a comparison of measured and calculated fission rates. The practicality of fast neutron radiography revealed by experiments to data is discussed primarily for Th/U measurements, and mixtures of other fissionable nuclei are briefly considered.

Haines, E. L.↗

Energetic ion beam magnetosphere injection and solar power satellite transport

The effects of ion beam injection in the magnetosphere are considered. The beam's parameters are those characteristic of the ion propulsion engines envisioned for use in solar power satellite placement (Hanley and Guttman, 1978). Specifically, from a detailed analysis of the beam's propagation through the magnetosphere it is shown that the bulk of the ion beam is not stopped in the magnetosphere. However, the relatively small fraction of the beam which is deposited via the beam's sheath loss may give rise to a large distortion in the magnetospheric plasma population. Possible loss mechanisms from the magnetosphere for this artificial energetic ion component are evaluated. Electron Coulomb scattering yields the shortest lifetime throughout most of the plasmasphere provided that plasmasphere heating by beam ions is not too intense. Charge exchange dominates beyond the plasmasphere. The effects of pitch angle scattering due to beam ion turbulence may appreciably shorten beam ion lifetimes throughout the magnetosphere

Curtis, S. A.↗

The new Batch Mode Ion Source for stand-alone operation at the Facility for Rare Isotope Beams (FRIB)

Gas stoppers have been used for a long-standing successful science program at Michigan State University with stopped and rare-isotope beams produced by projectile fragmentation. The National Superconducting Cyclotron Laboratory’s Coupled Cyclotron Facility has recently transitioned into the Facility for Rare Isotope Beams (FRIB) laboratory to provide rare isotopes using a high-power superconducting linear accelerator and new production facilities. To allow the science program with stopped and reaccelerated beams to continue during the transition period, a stand-alone capability was added. The Batch Mode Ion Source (BMIS) was built and has been providing beams of long-lived and stable isotopes of a variety of elements for successful user experiments. Finally, the BMIS system is described and results from the production of various beams are presented.

47 OTHER INSTRUMENTATION↗

Acceleration of uranium beam to record power of 10.4 kW and observation of new isotopes at Facility for Rare Isotope Beams

The Facility for Rare Isotope Beams (FRIB) is a major nuclear physics facility for research with fast, stopped, and reaccelerated beams that was successfully commissioned in May 2022. A key capability of FRIB is the production of an acceleration of the uranium beam, but this capability requires the facility to work at the design limits of the lowest charge-to-mass ratio and the highest power density on the beam intercepting devices. This paper presents techniques for overcoming the significant challenges in accelerating the uranium beam, culminating in the demonstration of 10.4 kW on target, and the discovery of three new isotopes. The high-power uranium beam enabled us to produce and identify G 88 a , A 93 s , and S 96 e , within the first 24 h of operation. The successful uranium operation at FRIB sets a new record for accelerated uranium beam power above 10 kW and opens a new avenue of research with rare isotopes. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Letter of Intent: Muonium R&D/Physics Program at the MTA

With the planned turn-on of the PIP-II 800 MeV superconducting proton linac, Fermilab will potentially become the world's best laboratory at which to carry out fundamental muon measurements, sensitive searches for symmetry violation, and precision tests of theory. In preparation, we propose to develop the techniques that will be needed. An R&D and physics program is proposed at the Fermilab MeV Test Area to use the existing 400 MeV Linac to demonstrate the efficient production of a slow muonium beam using $\mu^+$ stopped in a ~100 $\mu$m-thick layer of superfluid helium, and to use that beam to measure muonium gravity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward the Limits of Nuclear Existence: First Science with FRIB

The opportunity to explore the properties of short-lived atomic nuclei—or rare isotopes—in laboratories has enabled discoveries across the sciences related to the nature of the nuclear force and the limits of nuclear existence, the origin of the elements in the Universe, the cosmic matter–antimatter asymmetry, and the application of rare isotopes for society and the nation. The newest-generation Facility for Rare Isotope Beams (FRIB) on the campus of Michigan State University commenced operations in May 2022 as a user facility for the US Department of Energy, Office of Science, Office of Nuclear Physics. FRIB provides fast, stopped, and reaccelerated beams of rare isotopes for measurements, serving a 1,800-member-strong community of scientists from around the world. Here, this article reviews some of the first results from FRIB, showcasing the breadth of the science discoveries that have already occurred while the facility is ramping up to full capability.

FRIB↗

MTA Secondary Beamline Production and Optics Optimization

A new secondary beamline was recently installed in the MeV Test Area (MTA) with the objective of enhancing mu+/mu- production by factors of 3/8 by using a tungsten target versus the conventional graphite production target using the 400 MeV Fermilab proton Linac beam. Ultra-low energy muon beams can support world-class physics experiments for fundamental muon measurements, sensitive searches for symmetry violation, and precision tests of theory. Extensive production studies have confirmed higher muon yield from heavy targets (tungsten vs carbon), but also, surprisingly, showed significant differences in production fluence and energy spectrum between modern hadronic models (GENIEhad) and between GEANT and MCNP. Studies are also underway towards a high-efficiency source of muonium by stopping the mu+ beam in superfluid helium. Muon fluxes can be measured at MTA including using higher-Z and novel target geometries to test hadronic and production models which are critical to understanding ongoing experiments (Mu2e) and will significantly impact the planning of future HEP experiments and planning PIP II facilities. The MTA beamline will additionally support a broad user muon test beam for future experiments and R&D.

Ahmed, Shiza↗