Engineering PapersSearch

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

AI-Ready Control System for the Fermilab Accelerator Complex

Reliable, high-intensity operation of the Fermilab Accelerator Complex is critical to the success of the Long-Baseline Neutrino Facility and Deep Underground Neutrino Experiment. We describe the requirements and infrastructure necessary to support routine use of artificial intelligence and machine learning (AI/ML) in the accelerator control system. Three capabilities are identified: a machine learning operations (MLOps) framework standardizing the lifecycle of AI/ML automation from data management through deployment and monitoring; a data quality framework defining and enforcing standards required to build trustworthy AI/ML applications; and workflow integration with large language models to assist physicists, engineers, and operators with information retrieval, code development, and routine analysis. Use cases spanning beam diagnostics, beam control, and support system automation illustrate the technical requirements across the complex.

43 PARTICLE ACCELERATORS

A probe for real-time images of particle beams and their analyses in a merged-beams apparatus

A real-time charged particle beam probe was developed, which can be used both as a beam diagnostic (beam tuning) and to quantitatively determine the three-dimensional density distribution of a beam. The probe consists of a microchannel plate, an aluminized phosphor screen deposited on a fiber-optic faceplate, a flexible fiber-optic bundle, and a charge injection device (CID) in tandem. Digital or analog video output of the CID is fed into a computer or oscilloscope, respectively, for analysis or observation. The probe can be moved continuously along the beams' paths to obtain 'pictures' of the beam at any desired interval, thus giving three-dimensional form factors. The beams, singly or simultaneously, may be observed on the monitor facilitating the task of beam adjustment for optimum overlap. The digital output is used for quantitative computation of the beam overlaps. The device is linear with beam intensity, but the performance degrades with time due to beam damage of the microchannel plate.

Forand, J. L.

Rate-induced aging effects on Parallel-Plate Avalanche Counter (PPAC) caused by heavy ion beams

The Facility for Rare Isotope Beams (FRIB) is one of the premier scientific user facilities for nuclear science with radioactive beams, capable of producing most (approximately 80%) of the isotopes expected to exist, from oxygen to uranium, at energies up to 200 MeV/u. With the increase in beam power from the present 10 kW to the planned 400 kW, FRIB experiments are about to enter a new era. An unprecedented rate capability as well as stable performance of all the planned instrumentation intended for beam diagnostics and beam tuning is required at the expected high beam intensities (> 1 MHz). A summary of aging phenomena at high heavy-ion beam rates observed in the Advanced Rare Isotope Separator (ARIS) detectors for beam diagnostics, including Parallel Plate Avalanche Counters (PPAC) and plastic scintillation for time-of-flight measurements, is discussed. Current research and development project to mitigate rate-induced aging are presented.

Aging effects

Telescope beam-profile diagnostics and the solar limb

The basic method is described for determining the solar limb brightness profile properly corrected for spurious limb darkening caused by the far wings of the resolving beams encountered in large far-infrared and radio telescopes. When the far wings of the beam can be independently measured this problem is usually amenable to standard deconvolution procedures. Under a broad range of well-defined cases, solutions to the deconvolution problem are unique to within the discrimination provided by the core of the beam profile. The theory is applied to solar limb scans made recently on the James Clerk Maxwell Telscope to show solar limb brightening in 850 micron radiation.

Lindsey, Charles A.

Single-shot ionization-based monitor for pulsed electron beams

In this work, we present an experimental demonstration of a single-shot, nondestructive electron beam diagnostic based on the ionization of a low-density pulsed gas jet. In our study, 7 MeV electron bunches from a radio-frequency photoinjector, carrying up to 100 pC of charge, traversed a localized distribution of nitrogen gas (N 2 ). The interaction of the electron bunches with the N 2 gas generated a correlated signature in the ionized particle distribution, which was spatially magnified using a series of electrostatic lenses and recorded with a microchannel-plate detector. Various modalities, including point-to-point imaging and velocity mapping, are investigated. A temporal trace of the detector current enabled the identification of single- and double-ionization events. The characteristics of the ionization distribution, dependence on gas density, total bunch charge, and other parameters, are described. Approaches to scaling to higher electron bunch density and energy are suggested. Additionally, the instrument proves useful for comprehensive studies of the ionization process itself.

47 OTHER INSTRUMENTATION

Design of a self-diagnostic beam-mode piezoelectric accelerometer

A technique was developed for detecting in situ real-time soft failures in a beam-mode piezoelectric accelerometer. The new technique can be used to detect changes in the piezoelectric capacitance, the equivalent mechanical stiffness of the piezoelectric element and the surface mounting impedance, and the piezoelectric efficiency.

Flanagan, Patrick M.

Machine protection system for coherent electron cooling experiment

The coherent electron cooling (CeC) experiment employs a 15 MeV electron beam with up to a few milliamperes current which is capable of destroying the vacuum equipment or intercepting beam diagnostics. The high-current beam can be delivered to two different dumps. RF systems include normal conducting and superconducting cavities which also require protection from abnormal conditions. In this paper, we describe in detail the design and operation of the machine protection system for the CeC accelerator.

43 PARTICLE ACCELERATORS

A high-voltage MR-ToF mass spectrometer and separator for the study of exotic isotopes at FRIB

The Facility for Rare Isotope Beams (FRIB) delivers a wide variety of rare isotopes as fast, stopped, or reaccelerated beams to enable forefront research in nuclear structure, astrophysics, and fundamental interactions. To expand the scientific potential of FRIB’s stopped and reaccelerated beam programs, we are designing a Multi-Reflection Time-of-Flight mass spectrometer and separator (MR-ToF MS). It will enable high-precision mass measurements of short-lived isotopes, improve beam diagnostics, and deliver isobarically and isomerically purified beams to downstream experimental stations. It is designed to store ions at a kinetic energy of 30 keV, significantly enhancing ion throughput while maintaining high mass resolving power. In conclusion, we present the scientific motivation, technical design, and simulations demonstrating the expected performance of the system, which has the potential to significantly enhance FRIB’s mass measurement, diagnostic, and mass separation capabilities.

Electrostatic ion beam trap

The effect of filament peaking on electron beam weld quality

Electron beam welding uses high intensity beams that are generated by an electron emitting cathode under high vacuum conditions. The cathode, typically a ribbon or wire filament of refractory metal, must be heated to sufficiently high temperatures for electron emission to occur and must be carefully controlled to produce the desired beam current while at the same time optimizing filament lifetime. Traditional methods for doing this in commonly used triode gun assemblies consist of first finding the filament knee point in the filament current versus beam current relationship that produces the desired beam current for a given beam voltage. The filament current is then increased by some amount, typically 5–10%, per conventional wisdom to produce a peaked beam. This investigation studies and quantifies the beam and weld quality produced by underkneed and overpeaked filaments using electron beam diagnostics to measure the power density distribution of these beams. Underkneed filaments are shown to have power densities that drop off very quickly below the traditional knee, resulting in poor weld penetration. Kneed filaments do not reach the full beam intensity and also produce shallow welds. Increasing the filament current 10% above the traditional knee was shown to produce a circular Gaussian-like beam with peaked intensity optimized for welding and for filament lifetime. Further increases in the filament current that produce overpeaked beams do not significantly change the beam or weld quality and would only contribute to a reduced filament lifetime.

Electron Beam Welding

Ion beam sputtering in electric propulsion facilities

Experiments were undertaken to determine sputter yields of potential ion beam target materials, to assess the impact of charge exchange on beam diagnostics in large facilities, and to examine material erosion and deposition after a 957 hr test of a 5 kW-class ion thruster. The xenon ion sputter yield of flexible graphite was lower than other graphite forms especially at high angles of incidence. Ion beam charge exchange effects were found to hamper beam probe current collection diagnostics even at pressures from 0.7 to 1.7 mPa. Estimates of the xenon ion beam envelope were made and predictions of the thickness of sputter deposited coatings in the facility were compared with measurements.

Sovey, James S.

Ion beam sputtering in electric propulsion facilities

Experiments were undertaken to determine sputter yields of potential ion beam target materials, to assess the impact of charge exchange on beam diagnostics in large facilities, and to examine material erosion and deposition after a 957-hour test of a 5 kW-class ion thruster. The xenon ion sputter yield of flexible graphite was lower than other graphite forms especialy at high angles of incidence. Ion beam charge exchange effects were found to hamper beam probe current collection diagnostics even at pressures from 0.7 to 1.7 mPa. Estimates of the xenon ion beam envelope were made and predictions of the thickness of sputter deposited coatings in the facility were compared with measurements.

Sovey, James S.

Solenoidal Fields from Permanent Magnets for a Polarized Electron Preinjector

This technical note describes the design of a compact focusing solenoid constructed from permanent bar magnets, intended for the low-energy section of a spin-polarized electron injector. Typically, quadrupole triplets provide appropriate focusing for the low-energy spin rotator section; however, their large footprint precludes the insertion of sufficient beam diagnostics. The primary motivation of this study is to provide beam focusing while preserving the vertical spin orientation of the electron beam. We propose a solenoidal field composed of multiple permanent magnets arranged to naturally yield a zero longitudinal magnetic field integral ($\int B_zdz = 0$). This design serves as a compact, passive, and non-coupling alternative to traditional quadrupole triplets. We present the magnet arrangement, field calculation methodology, spin tracking simulations using space charge codes, and calculations demonstrating that the required field strength is achievable.

43 PARTICLE ACCELERATORS

High-resolution in-beam video rate imaging with the ClearXCam for synchrotron beamlines

The ClearXCam detector is a new video rate imaging in-beam monitor based on a diamond sensor. Imaging with 2304 effective pixels is achieved by sequentially biasing one of 48 metal stripes on one side of a diamond sensor, while reading out the current from 48 stripes on the other side of the sensor. This system was characterized for real-time X-ray beam diagnostics at synchrotron beam­line 17-BM at the National Synchrotron Light Source II. Significant results include: detection of in-beam structure via the imaging mode, beam focusing in one minute with real-time imaging feedback during a focusing event, linearity over five orders of magnitude, validation of a fast mode operating at 100 Hz, and sub-micron beam-positioning resolution. The system is now available commercially.

36 MATERIALS SCIENCE