Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “battery heating and cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Thermal design analysis for SuperTruck II lithium-titanate battery pack

Here, this paper presents a systematic thermal management analysis for a new lithium-titanate-oxide battery pack to be installed in a SuperTruck II, Class 8 hybrid truck. The authors investigate the feasibility of mounting the battery pack inside the vehicle and air-cooling it with fans supplying conditioned air from the cabin. Moreover, the cells within each module are to be immersed in a heat-transfer fluid to improve temperature homogeneity. A multi-stage thermal analysis is performed to ensure adequate thermal regulation of the battery under the proposed design, considering installation and operational constraints. The authors perform thermal and electrical characterization tests on a single cell. Results inform the development of computational fluid dynamics models of the cells, modules, and pack. Module-level analysis shows that the cell temperatures can be maintained below their upper operational limit of 55 °C with module wall-to-air heat transfer coefficients between 10 and 20 Wm -2 K -1 . Pack-level analysis of distinct configurations determines effective airflow paths for adequate heat transfer and delivers a final battery pack design that achieves sufficient cooling and temperature uniformity. A reduced-order electrothermal model is developed to rapidly predict the transient battery performance and to develop a temperature control strategy.

25 ENERGY STORAGE↗

The power reliability event simulator tool (PRESTO): A novel approach to distribution system reliability analysis and applications

The growing interest in onsite solar photovoltaic and energy storage systems is partially motivated by customer concerns regarding grid reliability. However, accurately assessing the effectiveness of PVESS in mitigating these interruptions requires a comprehensive understanding of location-specific outage patterns and the ability to simulate realistic scenarios. To address the gap, we introduce the Power Reliability Event Simulation TOol (PRESTO), the first publicly available tool that simulates location-specific power interruptions at the county level. PRESTO allows for a more realistic assessment of system reliability by considering the unpredictability and location-specific patterns of power interruptions. We applied PRESTO in a case study of a single-family home across three U.S. counties, examining the performance of a solar photovoltaic system with 10kWh of battery storage during short-duration power interruptions. Our findings show that this system reliably met 93% of energy demand for essential non-heating and cooling loads, fully serving these loads in 84% of events, despite the constraints of daily time-of-use bill management which limits the battery's state-of-charge reserve. However, when heating and cooling loads were included, system performance decreased significantly, with only 70% of demand met and full service in 43% of events. These results highlight the challenges of using solar photovoltaic and energy storage systems for short-duration outages, emphasizing the need to consider factors like battery size and grid charging strategies to improve reliability. Our study demonstrates the practical applications of PRESTO, providing valuable insights into potential mitigation strategies including grid charging and optimizing battery size.

14 SOLAR ENERGY↗

Cooling Vest

Because quadriplegics are unable to perspire below the level of spinal injury, they cannot tolerate heat stress. A cooling vest developed by Ames Research Center and Upjohn Company allows them to participate in outdoor activities. The vest is an adaptation of Ames technology for thermal control garments used to remove excess body heat of astronauts. The vest consists of a series of corrugated channels through which cooled water circulates. Its two outer layers are urethane coated nylon, and there is an inner layer which incorporates the corrugated channels. It can be worn as a backpack or affixed to a wheelchair. The unit includes a rechargeable battery, mini-pump, two quart reservoir and heat sink to cool the water.

Source record↗

Comparative analysis of thermal management systems in electric vehicles at extreme weather conditions: Case study on Nissan Leaf 2019 Plus, Chevrolet Bolt 2020 and Tesla Model 3 2020

With the surge in electric vehicle (EV) adoption and the need for extended driving ranges, optimizing energy efficiency, particularly through thermal management, is critical, especially in extreme weather. Managing the substantial energy needed for cabin climate control and battery temperature regulation can increase energy demands by over 50 %, severely limiting range. This study conducts a comparative analysis of thermal management systems (TMS) in three popular EV vehicles, 2020 Chevrolet Bolt, 2019 Nissan Leaf Plus, and 2020 Tesla Model 3, evaluating their distinct TMS configurations and performance under varied weather conditions. Using both numerical simulations and experimental data collected on a controlled test bench at Argonne National Laboratory, we assess how TMS architecture and operational modes influence energy consumption and range. A comprehensive TMS model was developed, integrating cabin and battery thermal sub-models in the Autonomie software platform, to simulate temperature fluctuations and range impacts. Cabin climate was modeled using a mono-zonal approach, while battery cell temperature distribution was estimated through a 2D nodal structure. Each vehicle's distinct TMS setup was evaluated: the Chevrolet Bolt and Tesla Model 3 use a dual evaporator vapor compression cycle with a PTC heater for the cabin and a coolant loop for battery thermal management; the Nissan Leaf Plus employs a heat pump with a PTC heater for the cabin and air-cooling for the battery. Tests conducted at ambient temperatures of 35°C, 22°C, -7°C, and -18°C reveal significant differences in energy use and range reduction across both configurations and conditions. At 35°C, the Tesla Model 3, Chevrolet Bolt, and Nissan Leaf Plus have a range reduction of 8%, 9%, and 13%, respectively, due to air conditioning. In winter, heating technology is paramount; at -7°C, the Nissan Leaf's heat pump configuration achieves a lower range reduction (19.3%) compared to the Tesla and Chevrolet Bolt PTC heaters, which reduce range by 28.3% and 31%, respectively. Further, this study provides valuable insights for automotive engineers, EV technology researchers, and thermal management system designers aiming to enhance electric vehicle performance by understanding how different weather conditions and TMS architectures impact energy consumption and driving range.

33 ADVANCED PROPULSION SYSTEMS↗

Experimental Evaluation of Thermal Storage Performance of a Dual-Purpose Underground Thermal Battery

A geothermal heat pump (GHP) system is an energy-efficient building heating and cooling technology with great potential for reducing energy consumption and decarbonization. However, applications of GHP are still limited due to the high cost, of which 30% is related to the cost of installing the conventional vertical bore ground heat exchangers, which are usually installed in boreholes 60 meters deep. A dual-purpose underground thermal battery (DPUTB) has been developed to offer a low-cost ground heat exchanger with a built-in thermal storage capacity. The DPUTB innovatively integrates a shallow-bore ground heat exchanger (the outer tank), which can be installed in a borehole less than 6 m deep, with thermal energy storage (TES) (the inner tank). DPUTB has the potential to reduce the cost of a ground source heat pump system while allowing shifting the electric demand of the building served by the GHP system from peak to off-peak hours of the electric grid by charging and discharging the thermal storage. A lab-scale (1:125 in volume) DPUTB prototype was built. Phase change material (PCM) was added to increase the thermal storage capacity and maintain the supply water temperature from the TES within the desired range for direct cooling operation during the discharge period. As PCMs are critical to the TES performance of the DPUTB, this study compared the influence of different PCMs (including salt hydrate and organic PCMs) on the discharge performance of the DPUTB. The thermal State of Charge (SoC) of the DPUTB was used to compare the performance resulting from using different PCMs. Test results indicate that the organic PCM (Methyl Laurate) outperforms salt-hydrate PCMs due to a lower melting temperature and a narrower melting temperature range during the phase change process. The results of this study provide a guide for PCM selection and the optimal design of DPUTB.

Wang, Lingshi↗

Low Carbon Technology Strategies: Hospital

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon hospitals within their existing building portfolios. Hospitals typically include complex heating and cooling systems and specialty medical equipment.

analytics↗

Numerical modeling and parametric study of a dual purpose underground thermal battery

We report integrating thermal energy storage with building energy systems can enable flexible building electric demands at buildings to help mitigate the mismatch between electricity supply and demand. A novel building heating and cooling system that integrates a dual-source heat pump with hybrid thermal storage named dual-purpose underground thermal battery (DPUTB) has been developed for reshaping building electric demands. The proposed DPUTB integrated geothermal heat pump system is an original innovation that enables Grid-interactive Energy Efficient buildings. This paper focuses on the study of the novel DPUTB. The DPUTB works as both a thermal storage tank (an inner tank) and a ground heat exchanger (an outer tank separated from the inner tank by the insulation material). High fidelity and computationally effective models are needed to predict the performance of the novel DPUTB. This study has developed a simplified dynamic model for the DPUTB according to heat transfer and energy conservation principles and validated it by using experimental data obtained from testing a small-scale DPUTB apparatus. A parametric study was conducted to identify a design that can achieve the target thermal storage performance of load shift and energy efficiency. The parametric study results show that the inner tank shell thermal conductivity and the phase change material's melting point are the two most influencing factors on the performance of the DPUTB. One single full-size DPUTB with the identified design could provide 1-ton cooling (3.51 kW) with the supply temperature lower than 11 °C for 4 hours in summer after being fully charged in 8 hours. The inner tank filled with phase change material is for cooling thermal storage as a latent tank in the design. However, its capacity can be as high as 60 MJ as a sensible water tank for heating storage in winter. In the future study, the DPUTB model will be incorporated into the dual-source heat pump system for evaluating the overall system performance of demand side management in the long term.

25 ENERGY STORAGE↗

Proof-of-Concept for Sensor Modeling in MOOSE for the Design of Autonomous Nuclear Reactor Control

Autonomous operation is essential for the deployment of microreactors and fission batteries, both in terrestrial and space applications. For this reason, recent studies have investigated autonomous control by using adaptive model predictive control and multi-objective optimization for heat pipe–cooled microreactors under normal and heat pipe failure conditions. However, prototypes of microreactors and fission batteries do not exist yet, and even the design space has not been narrowed down conclusively, making the instrumentation and control system design difficult. For this reason, there is a need for flexible computational capabilities to create a numerical stand-in of potential microreactor and fission battery designs. The latter can be used to design and test control strategies to support autonomous operations. In this poster, we describe the initial implementation of a pluggable sensor system for the easy implementation of realistic sensor models in the multiphysics object-oriented simulation environment (MOOSE) framework. This new capability will enable MOOSE users to create a numerical stand-in of microreactors and fission batteries, ultimately allowing them to easily test new control algorithms, and instrumentation strategies for advanced systems in the design phase.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

A prototype cooling blanket for mitigating occupant overheating risk in a hot indoor environment: Modeling and assessments

Conventional ways of cooling a room or an entire house for occupant thermal comfort during summer consume a significant amount of energy and are vulnerable to overheating risk during power outages that lead to loss of cooling system operations. This study investigates a low-power cooling blanket, as a Personal Cooling System (PCS), that covers the upper human body for direct cooling during a five-day heat wave in a single-family house. A modeling framework is developed for evaluating the thermal and energy performance of the cooling blanket, which builds upon the co-simulation of three models: a house energy model, a personal thermal comfort model, and a cooling blanket model. Simulation results show that under the power outage scenario, the cooling blanket can greatly reduce the occupant heat stress with a reduction of daily hours of exceedance (discomfort hours defined as TSV>2) by up to 17.2 h (a 95.3 % improvement from the baseline power outage without the blanket). The cooling blanket, equipped with an innovative electrocaloric heat pump (COP as high as 10.1) consumes 6.31 W and can be operated by a portable battery for several days. The cooling blanket consumes only 0.28 % of the electricity of a central air-conditioning system running to provide cooling for the whole house during the five-day heatwave period. The findings justify further research of electrocaloric wearable PCS as low-power effective cooling to ensure thermal survivability of occupants during extreme indoor environments.

Electrocaloric heat pump↗

Development of Integrated Mechanical Pods

This presentation highlights early wins, updated progress, and upcoming developments on ‘national-scale shared development platform’ for rapid prototyping, testing and validation of various integrated Mechanical Pod solutions and form factors. Such pod solutions consist of a set of all-electric heat pump mechanical equipment that have integrated functionalities through built-in controls, with heating, cooling, hot water, ventilation (including energy recovery), electrical management, and battery storage within a single package. The presentation draws inspiration from the success of bathroom pods in the US modular construction industry, UK’s efforts with unitizing mechanical systems as ‘utility cupboards’, and VEIC’s early wins in design-build of all-electric Mechanical Pod solutions in Vermont. The presentation includes researchers and partners involved with NREL in Design for Manufacturing and Assembly (DfMA), Virtual Design and Construction (VDC), and digital twin based process optimization modeling of integrated Mechanical Pod solutions. The presentation aims to highlight early wins from such a platform and how various physical and virtual tools are currently being employed as part of NREL’s ongoing multi-year project funded by US DOE. Streamlined procurement, coordination, installation, and O&M of Mechanical Pods such that the majority of work is delegated to the off-site modular factory implies monetary savings. Such a seemingly basic shift in location of the construction process leads to great reduction in complexity, first cost, lead time, and waste, and greater opportunities for innovative compartmentalization and integration of mechanical systems appropriately sized for each apartment or hotel guest room. However, past studies on unitized combination systems show that high installation costs, maintenance issues, challenges with system integration, limitations in existing electrical infrastructure, and lack of architecturally appealing solutions are key barriers. NREL and partners aim to address key barriers through DfMA approach, rapid prototyping and testing, and digital twin process optimization modeling. The presentation is also a call for interested entities to partner with NREL as part of the national-scale development platform, help drive both product and process innovation, and encourage open source sharing of learnings. Learning objectives include (1) learn about the vision of national-scale shared development platform for process-product innovation on integrated mechanical pod solutions and how to get involved, (2) gain an understanding of the components of an all-electric, high performance home, design characteristics and equipment included in an all-electric mechanical pod, integration of mechanical systems within a modular factories’ assembly line, and the system’s commissioning, operation and maintenance. The pre-planning and coordination with the factory and sub-contractors are also highlighted, (3) gain an understanding of using process modeling tools to quantify resource-constrained performance of operations (such as integration of energy efficiency strategies) to manufacture modules of varying design, (4) gain insights on virtual design, rapid prototyping, and emulated testing of various form factors across different climatic conditions. The need for such preliminary testing with open source sharing of learnings will also be highlighted.

30 DIRECT ENERGY CONVERSION↗

Wind power demonstration and siting problems

Technical and economic feasibility studies on a small windmill to provide overnight charging for an electrically driven car are reported. The auxiliary generator provides power for heating and cooling the vehicle which runs for 25 miles on battery power alone, and for 50 miles with the onboard charger operating. The blades for this windmill have a diameter of 12 feet and are coupled through to a conventional automobile alternator so that they are able to completely recharge car batteries in 8 hours. Optimization of a windmill/storage system requires detailed wind velocity information which permits rational sitting of wind power system stations.

Bergey, K. H.↗

Methods for the photochemical utilization of solar energy

The paper considers the 'ground rules' which govern the efficiency of photochemical solar energy conversion and then summarizes the most promising approaches in each of three categories: photochemically assisted thermal systems for the heating and/or cooling of structures; photogalvanic systems for the production of electrical power in applications, such as photorechargeable batteries or inexpensive 'solar cells'; and photochemical formation of fuels for combustion and for use as chemical feedstocks or foods. Three concepts for the photochemical utilization of solar energy in space are found to be particularly promising: (1) photochemical trans-cis isomerization of indigold dyes for photoassisted heating or cooling, (2) the redox stabilized photoelectrolysis cell for the production of hydrogen (and/or oxygen or other useful chemicals), and (3) the liquid-junction photovoltaic cell for the production of electrical power.

Schwerzel, R. E.↗

A Comprehensive Numerical and Experimental Study for the Passive Thermal Management in Battery Modules and Packs

Cooling plates in battery packs of electric vehicles play critical roles in passive thermal management systems to reduce risks of catastrophic thermal runaway. In this work, a series of numerical simulations and experiments are carried out to unveil the role of cooling plates (both between cells and a bottom plate parallel to the cell stack) on the thermal behavior of battery modules and packs under nail penetrations. First, we investigated the role of side cooling plates on the thermal runaway propagation mitigation in battery modules (1S3P) and packs (3S3P) by varying the key parameters of the side cooling plates, such as plate thicknesses, thermal contact resistances, and materials. Then, three important factors for passive thermal management systems are identified: (i) thermal mass of side cooling plates, (ii) interfacial thermal contact resistances, and (iii) the effective heat transfer coefficients at exterior surfaces. The roles of bottom cooling plates on thermal runaway propagation mitigation in 1S3P and 1S5P battery modules are numerically investigated by comparing the thermal behavior of the modules with only side cooling plates and with both side and bottom cooling plates.

25 ENERGY STORAGE↗

Concepts for application of 500- to 2500-We Brayton power systems for shuttle-launched missions

A mini-Brayton power system in the power range of 500 to 2500 We utilizing the multihundred Watt isotope heat source was studied for use in shuttle-launched experiments. The system consists of a single closed gas loop containing a single-shaft, gas cooled, compressor-alternator turbine assembly; a heat source heat exchanger assembly; a startup battery package; an electrical control module; a recuperator; a gas radiator; and a multifoil superinsulation system. The basic configuration and major nuclear payloads for shuttle integration are discussed. It is concluded that mini-Brayton systems have low isotope inventories and high electrical output per thermal input, and have the capability of flying all earth orbital and interplanetary missions with little degradation in performance.

Block, H. B.↗

Field Test and Thermal Performance Comparison of a Novel Underground Thermal Battery with a Single U-tube Borehole Heat Exchanger for Geothermal Heat Pump Application

Geothermal Heat Pumps (GHP) are a proven technology to electrify and decarbonize space heating and cooling by utilizing the thermally consistent underground as a heat sink or source. However, the high drilling costs of conventional borehole heat exchangers (BHEs) associated with GHP systems and subsurface heterogeneity have been two major challenges to their widespread adoption. In this paper, we present results from a field-scale pilot of an Underground Thermal Battery (UTB) as a potential alternative to a conventional BHE. To benchmark the UTB performance, a side-by-side field test was conducted to compare the UTB with a conventional BHE installed at the same site. The UTB was installed in a 7.01-meter-deep borehole having a diameter of 0.9 meter, whereas the conventional BHE (with single U-tube loop) is in a borehole with 36.6-meter depth and 0.15-meter diameter. Both are integrated into a GHP system to meet the thermal energy demands of office space at the Illinois Energy Farm on the University of Illinois Urbana-Champaign campus. The system’s performance is compared in terms of heat transfer rate, outlet temperatures, and contributions to the overall thermal power of the GHP system under varying thermal demands and in different heat pump operation modes: heating only, cooling only, and hybrid (alternative, diurnal heating and cooling). Results to date indicate that the UTB delivers a more consistent response under during a time period of varying thermal demands. Its operational performance is better during short-term with higher thermal demands, while the conventional BHE performs better under continuous, long-term thermal demands.

Pokhrel, Sajjan [ORNL] (ORCID:0000000228523749)↗

Thermal management of a high temperature sodium sulphur battery stack

The sodium sulfur battery is an advanced secondary battery with high potential for grid-level storage due to their high energy density, low cost of the reactants, and high open-circuit voltage. However, as the operating temperature of the battery is high (about 300 °C), effective thermal management is required to prevent thermal runaway under high current density operation. Here, to develop efficient thermal management strategies, a detailed, thermo-electrochemical, non-isothermal, distributed dynamic model of a sodium-sulfur battery stack is developed. Models of three thermal management strategies are developed and analyzed in this work: active cooling, passive cooling, and hybrid cooling. The active cooling strategy uses air as the cooling medium whereas, the passive cooling strategy uses a phase change material. In the hybrid cooling strategy, both active and passive cooling strategies are used. Due to the high operating temperature of the sodium sulfur batteries, the rejected heat can be utilized effectively and consequently a high variability in the heat rejection rate may not be acceptable. Performance of these strategies is analyzed under high current density operation by evaluating the variability in the cell temperature during charge/discharge cycles, temperature difference between the cells based on their locations, and variability in the heat rejection rate. The phase change-based hybrid thermal management strategy with an embedded controller maintained the temperature variation within ±/- 2.8 °C. Considering the tradeoff between the capital cost for PCM, fan power requirement, and variability in the heat rejection rate, the optimal quantity of the PCM and the maximum air velocity for the maximum current density of 260 mA/cm 2 (0.55 C-rate) were found be 0.74 g/Wh and 3 m/s, respectively.

25 ENERGY STORAGE↗

Low Carbon Technology Strategies: Midrise Apartment

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon midrise apartment buildings within their existing building portfolios. Midrise apartments may use packaged rooftop units for heating, cooling, and ventilation or central plant systems for larger buildings.

analytics↗

Spokane Eco-District Campus Performance Under Alternative Electricity Rates: Benefits for virtual power plant participants and suppliers

Here, the respective benefits for virtual power plant participants and suppliers are revealed and compared under alternative electricity rate structures, including conventional large commercial electricity rates, large commercial electricity rates with special rates for demand-side generation, and dynamic hourly transactive prices. These three scenarios were explored using the capabilities of the Eco-District campus, a virtual power plant in Spokane, Washington, that is supplied electricity by Avista Utilities. The Eco-District Campus was modeled to host solar power generation, battery energy storage, and thermal energy resources that must be coordinated with building heating and cooling needs. First, the electricity supplier’s costs for energy, infrastructure, and energy losses were modeled. Then, the virtual power plant’s performance was modeled while presuming that its manager would minimize its costs under its electricity rate structure. The demand charges of conventional commercial electricity rates managed monthly peak, as would be expected, but hourly dynamic transactive pricing resulted in a striking alignment between the costs incurred by the supplier and the virtual power plant’s energy costs.

Electricity rates↗