Life Extension Activities for the Hubble Space Telescope

With the cancellation of the Hubble Space Telescope (HST) Servicing Mission 4 (SM4), the HST Project will face numerous challenges to keep the Telescope operating during the remainder of the decade. As part of the SM4, the HST Project had planned to install various upgrades to the Telescope including the installation of new batteries and new rate integrating gyros. Without these upgrades, reliability analysis indicates that the spacecraft will lose the capability to conduct science operations later this decade. The HST team will be severely challenged to maximize the Telescope's remaining operational lifetime, while still trying to maximize - its science output and quality. Two of the biggest areas of concern are the age and condition of the batteries and gyros. Together they offer the largest potential extension in Telescope lifetime and present the biggest challenges to the HST team. The six Ni-H batteries on HST are the original batteries from launch. With fourteen years of operational life, these batteries have collectively lasted longer than any other comparable mission. Yet as with all batteries, their capacity has been declining. Engineers are examining various methods to prolong the life of these mission critical batteries, and retard the rate of degradation. This paper will focus on these and other efforts to prolong the life of the HST, thus enabling it to remain a world-class observatory for as long as possible.

Walyus, Keith D.↗

Hybrid Power Management

An engineering discipline denoted as hybrid power management (HPM) has emerged from continuing efforts to increase energy efficiency and reliability of hybrid power systems. HPM is oriented toward integration of diverse electric energy-generating, energy-storing, and energy-consuming devices in optimal configurations for both terrestrial and outer-space applications. The basic concepts of HPM are potentially applicable at power levels ranging from nanowatts to megawatts. Potential applications include terrestrial power-generation, terrestrial transportation, biotechnology, and outer-space power systems. Instances of this discipline at prior stages of development were reported (though not explicitly labeled as HPM) in three prior NASA Tech Briefs articles: "Ultracapacitors Store Energy in a Hybrid Electric Vehicle"(LEW-16876), Vol. 24, No. 4 (April 2000), page 63; "Photovoltaic Power Station With Ultracapacitors for Storage" (LEW-17177), Vol. 27, No. 8 (August 2003), page 38; and "Flasher Powered by Photovoltaic Cells and Ultracapacitors" (LEW-17246), Vol. 24, No. 10 (October 2003), page 37. As the titles of the cited articles indicate, the use of ultracapacitors as energy-storage devices lies at the heart of HPM. An ultracapacitor is an electrochemical energy-storage device, but unlike in a conventional rechargeable electrochemical cell or battery, chemical reactions do not take place during operation. Instead, energy is stored electrostatically at an electrode/electrolyte interface. The capacitance per unit volume of an ultracapacitor is much greater than that of a conventional capacitor because its electrodes have much greater surface area per unit volume and the separation between the electrodes is much smaller. Power-control circuits for ultracapacitors can be simpler than those for batteries, for two reasons: (1) Because of the absence of chemical reactions, charge and discharge currents can be greater than those in batteries, limited only by the electrical resistances of conductors; and (2) whereas the charge level of a battery depends on voltage, temperature, age, and load condition, the charge level of an ultracapacitor, like that of a conventional capacitor, depends only on voltage.

Eichenberg, Dennis↗

The Cognition Battery: Developing a Normative Database for Spaceflight and Examining the Impact of Prolonged Isolation and Confinement on Cognitive Performance

INTRODUCTION: Astronauts on future long duration space exploration will be required to execute complex tasks in which even minor errors could have devastating consequences. Intact cognition is critical to maintain exceptional performance standards and it is possible that variability even at the highest ends of the performance spectrum will impact operational tasks. Exposure to spaceflight hazards could compromise cognitive performance, and decrements have been documented under conditions of altered gravity and radiation exposure. The cognitive impacts of prolonged isolation and confinement remain relatively unknown. Traditional neuropsychological assessments cannot support earth independent monitoring, do not have normative comparisons for high functioning individuals, and most are not sensitive enough to detect small performance decrements. The Cognition Battery was developed to address these limitations but currently lacks comprehensive normative data. In this project, we aimed to 1) develop a preliminary normative database for astronauts and astronaut surrogates using the Cognition Battery, and 2) characterize differences in cognitive performance after short and long duration analog missions. PARTICIPANTS & METHODS: We assessed baseline cognitive performance by administering the Cognition Battery to 97 astronaut and astronaut surrogates recruited to approximate astronaut demographics (mean age: 39.38, SD=7.62; 35.1% female; 91.7% advanced degrees). For aim 1, we calculated speed and accuracy outcomes for each subtest and summarized the data with descriptive statistics. We examined the relationship between age and performance with Pearsons’s correlations and the relationship between gender and performance with independent samples t-tests. A subset of individuals on short duration (n=48; mean age: 38.18, SD=7.14; 37.5% female; 91.7% advanced degrees) missions of 45 days and long duration (n=34; mean age: 42.12, SD=8.39; 38.2% female; 94.1% advanced degrees) missions ranging from 4-8 months were administered the Cognition Battery during and after their respective missions. For aim 2, we accounted for practice effects using published corrections, and z-transformed post-mission scores using the full sample’s baseline scores. One-way analysis of covariance tests determined the main effect of analog duration on post-mission performance, after accounting for age and gender. The False Discovery Rate method was applied to adjust for multiple comparisons. RESULTS: In the full normative sample, older age was associated with slower reaction times on a processing speed task (r=.39, p=.02), and men were more accurate on processing speed (t=-2.19, p=.03) and faster on sustained attention (t=2.02, p=.049) and risk-taking tasks (t=2.49, p=.02). We observed a main effect of duration on performance on tasks of visual memory (f(1)=5.62, p=.04), processing speed (f(1)=5.48, p=.03), and sensorimotor functioning (f(1)=39.52, p < .001), such that slower performance was observed after long duration missions relative to short. Only sensorimotor functioning was significant after adjustments for multiple comparisons (adjusted p<.001). DISCUSSION: The full sample represents the largest dataset of cognitive performance assessed by the Cognition Battery available and can be used for further research in spaceflight and high-performance populations. Relationships between performance and key demographic variables suggest future research that include age and gender stratification is needed. Our results also show minimal changes in cognitive performance between longer and shorter periods of isolation and confinement.

S I Dev↗

Characterization of physiochemical properties of polymeric and electrochemical materials for aerospace flight

Nickel-cadmium rechargeable batteries are a vital and reliable energy storage source for aerospace applications. As the demand for longer life and more reliable space batteries increases, the understanding and solving of cell aging factors and mechanisms become essential. Over the years, many cell designs and manufacturing process changes have been developed and implemented. Cells fabricated with various design features were life cycled in a simulated low-Earth orbit regime. Following the test program, a comprehensive electrochemical analysis of cell components was undertaken to study cell degradation mechanisms. Discharge voltage degradation or voltage plateau has been observed during orbit cycling, but, its cause and explanation have been the subject of much discussion. A Hg/HgO reference electrode was used to monitor the reference versus each electrode potential during the discharge of a cycled cell. The results indicate that the negative electrode was responsible for the voltage plateau. Cell analysis revealed large crystals of cadmium hydroxide on the surface of the negative electrode and throughout the separator.

Rock, M.↗

A Physics-Based Modeling Framework for Prognostic Studies

Prognostics and Health Management (PHM) methodologies have emerged as one of the key enablers for achieving efficient system level maintenance as part of a busy operations schedule, and lowering overall life cycle costs. PHM is also emerging as a high-priority issue in critical applications, where the focus is on conducting fundamental research in the field of integrated systems health management. The term diagnostics relates to the ability to detect and isolate faults or failures in a system. Prognostics on the other hand is the process of predicting health condition and remaining useful life based on current state, previous conditions and future operating conditions. PHM methods combine sensing, data collection, interpretation of environmental, operational, and performance related parameters to indicate systems health under its actual application conditions. The development of prognostics methodologies for the electronics field has become more important as more electrical systems are being used to replace traditional systems in several applications in the aeronautics, maritime, and automotive fields. The development of prognostics methods for electronics presents several challenges due to the great variety of components used in a system, a continuous development of new electronics technologies, and a general lack of understanding of how electronics fail. Similarly with electric unmanned aerial vehicles, electrichybrid cars, and commercial passenger aircraft, we are witnessing a drastic increase in the usage of batteries to power vehicles. However, for battery-powered vehicles to operate at maximum efficiency and reliability, it becomes crucial to both monitor battery health and performance and to predict end of discharge (EOD) and end of useful life (EOL) events. We develop an electrochemistry-based model of Li-ion batteries that capture the significant electrochemical processes, are computationally efficient, capture the effects of aging, and are of suitable accuracy for reliable EOD prediction in a variety of usage profiles.

Li-ion Batteries↗

Polymer research

Aging, viscoelastic, and electrical conductivity of elastomers, molecular weight determination, and battery separators

Source record↗

Electrochemistry-based Battery Modeling for Prognostics

Batteries are used in a wide variety of applications. In recent years, they have become popular as a source of power for electric vehicles such as cars, unmanned aerial vehicles, and commericial passenger aircraft. In such application domains, it becomes crucial to both monitor battery health and performance and to predict end of discharge (EOD) and end of useful life (EOL) events. To implement such technologies, it is crucial to understand how batteries work and to capture that knowledge in the form of models that can be used by monitoring, diagnosis, and prognosis algorithms. In this work, we develop electrochemistry-based models of lithium-ion batteries that capture the significant electrochemical processes, are computationally efficient, capture the effects of aging, and are of suitable accuracy for reliable EOD prediction in a variety of usage profiles. This paper reports on the progress of such a model, with results demonstrating the model validity and accurate EOD predictions.

battery↗

Usage-based Lifing of Lithium-Ion Battery with HybridPhysics-Informed Neural Networks

Lithium-ion batteries are commonly used to power unmanned aircraft vehicles (UAVs).The ability to model and forecast the remaining useful life of these batteries enables UAV reliability assurance. Building accurate models for battery state of charge and state of health based on first principles is challenging due to the complex electrochemistry that governs battery operations and computational complexity required to solve them. Therefore, reduced order models are often used due to their ability to capture the overall battery discharge. Un-fortunately, these simplifications lead to residual discrepancy between model predictions and observed data. In this paper, we present a hybrid modeling approach merging reduced-order models and neural networks. In this approach, while most of the input-output relationship is captured by Nernst and Butler-Volmer equations, data-driven kernels reduce the gap between predictions and observations. We validate our approach using data publicly available through the NASA Prognostics Center of Excellence repository. Results showed that our hybrid battery prognosis model can be successfully calibrated, even with a limited number of observations.

Lithium-ion Battery↗

Effects of Vestibular Loss on Orthostatic Responses to Tilts in the Pitch Plane

The purpose of this study was to determine the extent to which vestibular loss might impair orthostatic responses to passive tilts in the pitch plane in human subjects. Data were obtained from six subjects having chronic bilateral vestibular loss and six healthy individuals matched for age, gender, and body mass index. Vestibular loss was assessed with a comprehensive battery including dynamic posturography, vestibulo-ocular and optokinetic reflexes, vestibular evoked myogenic potentials, and ocular counterrolling. Head up tilt tests were conducted using a motorized two-axis table that allowed subjects to be tilted in the pitch plane from either a supine or prone body orientation at a slow rate (8 deg/s). The sessions consisted of three tilts, each consisting of20 min rest in a horizontal position, tilt to 80 deg upright for 10 min, and then return to the horizontal position for 5 min. The tilts were performed in darkness (supine and prone) or in light (supine only). Background music was used to mask auditory orientation cues. Autonomic measurements included beat-to-beat recordings of blood pressure (Finapres), heart rate (ECG), cerebral blood flow velocity in the middle cerebral artery (transcranial Doppler), end tidal CO2, respiratory rate and volume (Respritrace), and stroke volume (impedance cardiography). For both patients and control subjects, cerebral blood flow appeared to exhibit the most rapid adjustment following transient changes in posture. Outside of a greater cerebral hypoperfusion in patients during the later stages of tilt, responses did not differ dramatically between the vestibular loss and control subjects, or between tilts performed in light and dark room conditions. Thus, with the 'exception of cerebrovascular regulation, we conclude that orthostatic responses during slow postural tilts are not substantially impaired in humans following chronic loss of vestibular function, a result that might reflect compensation by nonvisual graviceptor inputs (e.g., somatosensory) or other circulatory reflex mechanisms.

Wood, Scott J.↗

Current developments in electrochemical storage systems for satellites

The need for batteries with greater power capacity and service life for power satellites is examined. The Ni/Cd and Ni/H batteries now being used must be upgraded to meet advanced space requirements. Improvements in power capacity, service life, and cycle count for various satellites in LEO and GEO orbits are discussed. The Ni/Cd and Ni/H cell reactions are explained, and the solubility and volume changes for various charged and uncharged masses are described. A chart of the energy content and cycle count for various cell systems is presented, and the factors which cause aging and failure in the Ni/Cd and Ni/H cell systems are discussed. The advantages of the Ni/H battery are given and the need for more developed electrochemical storage systems because of an increase in the mass of satellites is explained. The requirements for space batteries and the work currently done by NASA and West Germany on advanced batteries are discussed.

Gutmann, G.↗

Effects of Acute Exposures to Carbon Dioxide upon Cognitive Functions

Carbon dioxide (CO2) originates from human metabolism and typically remains about 10-fold higher in concentration on the International Space Station (ISS) than at the earth's surface. There have been recurring complaints by crew members of episodes of "mental viscosity" adversely affecting their performance, and there is evidence from the ISS that associates CO2 levels with reports of headaches by crewmembers. Consequently, flight rules have been employed to control CO2 below 3 mm Hg, which is well below the existing Spacecraft Maximum Allowable Concentration (SMAC) of 10 mm Hg for 24-hour exposures, and 5.3 mm Hg for exposures of 7 to 180 days. Headaches, while sometime debilitating themselves, are also symptoms that can provide evidence that physiological defense mechanisms have been breached, and there is evidence that CO2 has effects at levels below the threshold for headaches. This concern appears to be substantiated in reports that CO2 at concentrations below 2 mm Hg substantially reduced some cognitive functions that are associated with the ability to make complex decisions in conditions that are characterized by volatility, uncertainty, complexity, ambiguity, and delayed feedback. These are conditions that could be encountered by crews in off-nominal situations or during the first missions beyond low earth orbit. Therefore, we set out to determine if decision-making under volatile, uncertain, confusing and ambiguous circumstances, where feedback is delayed or absent, is correlated with low levels of CO2 during acute exposures (several hours) in crew-like subjects and to determine if additional cognitive domains are sensitive to concentrations of CO2 at, or below, current ISS levels by using a test battery that is currently available onboard ISS. We enrolled 22 volunteers (8 females, 14 males) between the ages of 30-55 (38.8 +/- 7.0) years whose training and professional experience reflect that of the astronaut corps. Subjects were divided among 4 study groups. Exposures occurred in the 20-foot environmental chamber in Bldg 7 at JSC. Each group was exposed to each of four concentrations of CO2 (600, 1200, 2500, and 5000 ppm), and the exposure order was balanced across the groups which were randomly assigned to 4 possible complete exposure orders. Study participants and investigators were blinded to the exposure order. Each exposure lasted 4 hours and occurred on the same day each week for 4 consecutive weeks. Testing included the Strategic Management Simulation (SMS) methodology and the Cognition battery of psychometric measures that are being utilized aboard the ISS. Subjects participated in a familiarization session one week prior to the start of exposure sessions. Each exposure session followed the schedule noted in Figure 1 below. On the morning of each exposure, subjects completed the Cognition battery in a conference room at indoor ambient CO2 levels. Subjects then entered the exposure chamber and were acclimated to the environment for 15 minutes before completing another round of the Cognition battery. After a 20 minute rest, subject completed the approx.80 minute SMS. Subjects were allowed another 20 minute rest period before completing the final Cognition test battery in the exposure chamber. Subjects then returned to the conference room where they completed one final round of Cognition. Data from both testing methodologies are currently being analyzed and will be presented. Study investigators have not yet been unblinded to the coded exposure concentrations, but preliminary results suggest differences.

Ryder, V. E.↗

Nickel cadmium battery operations and performance

The Earth Radiation Budget Satellite (ERBS), Compton Gamma Ray Observatory (CGRO), Upper Atmosphere Research Satellite (UARS), and Extreme Ultraviolet Explorer (EUVE) spacecraft are operated from NASA's Goddard Space Flight Center (GSFC) in Greenbelt, Maryland. On-board power subsystems for each satellite employ NASA Standard 50 Ampere-hour (Ah) nickel-cadmium batteries in a parallel configuration. To date, these batteries have exhibited degradation over periods from several months (anomalous behavior, UARS and CGRO (MPS-1); to little if any, EUVE) to several years (old age, normal behavior, ERBS). Since the onset of degraded performance, each mission's Flight Operations Team (FOT), under the direction of their cognizant GSFC Project Personnel and Space Power Application Branch's Engineers has closely monitored the battery performance and implemented several charge control schemes in an effort to extend battery life. Various software and hardware solutions have been developed to minimize battery overcharge. Each of the four sections of this paper covers a brief overview of each mission's operational battery management and its associated spacecraft battery performance. Also included are new operational procedures developed on-orbit that may be of special interest to future mission definition and development.

Rao, Gopalakrishna↗

Temperature Pill

Ingestible Thermal Monitoring System was developed at Johns Hopkins University as means of getting internal temperature readings for treatments of such emergency conditions as dangerously low (hypothermia) and dangerously high (hyperthermia) body temperatures. ITMS's accuracy is off no more than one hundredth of a degree and provides the only means of obtaining deep body temperature. System has additional applicability in fertility monitoring and some aspects of surgery, critical care obstetrics, metabolic disease treatment, gerontology (aging) and food processing research. Three-quarter inch silicone capsule contains telemetry system, micro battery, and a quartz crystal temperature sensor inserted vaginally, rectally, or swallowed.

Source record↗

The Mars Reconnaissance Orbiter Mission: 2018 Status

The Mars Reconnaissance Orbiter (MRO) continues its dual-mode mission of scientific exploration and programmatic support. Now in its 13th year of flight (and its 12th year in its low-altitude, sun-synchronous orbit around Mars), the spacecraft continues in its normal flight mode and its science instruments continue to acquire a treasure trove of data which is being used to study the Martian environment (surface, sub-surface, and atmosphere). To date (July 2018), more than 333 TB of scientific data have been returned to Earth. Building onto the 2017 IAC paper: “The Mars Reconnaissance Orbiter Mission: Continuing a Record of Exploration from Mars Orbit,” [1] this paper provides a 2018 status update on the MRO Mission. A signature event since the 2017 writing is the onset and evolution of a planet-encircling dust event (PEDE), the first such event since 2007. Additional recent science highlights for MRO include the discovery of mid-latitude ice cliffs, polar cap characterization, daily global mapping of the 2018 PEDE dust activity and the atmospheric thermal response, further characterization of the tantalizing recurring slope lineae (RSL), and continued detection of surface changes. Programmatically, UHF relay support for the Mars Science Laboratory (MSL) rover Curiosity and the Mars Exploration Rover (MER) rover Opportunity continues at a pace that provides the engineers and scientists operating those surface vehicles timely information to support their mission planning and science analysis. Most of the landing site characterization requests for the NASA Mars 2020 rover and the ESA ExoMars Rover/Surface Platform (RSP) missions have been completed, with final acquisitions delayed due to the obscuring dust haze from the current PEDE. In parallel, the flight team has faced new engineering challenges as the spacecraft has aged. The team has developed and is implementing actions that are aimed at stretching spacecraft battery life. A new all-stellar capability using the spacecraft’s star trackers now allows for normal spacecraft operations without IMUs. In addition to its current relay duties, MRO will be synchronized to provide critical communications support for the InSight Entry, Descent, and Landing (EDL) event on November 26, 2018, and will be readied to support InSight’s critical commissioning phase with UHF relay support and environmental characterization. A new split-pass relay capability has been developed which will allow MRO to relay with two surface vehicles in “close proximity” on the same overflight, i.e. the InSight lander and the Curiosity rover. Extended for another year of operations by NASA, this paper will highlight recent scientific progress and describe actions that will extend MRO’s life well into the 2020’s as a key element of the Mars Exploration Program.

Zurek, Richard W.↗

Portable Multigas Monitors for International Space Station

The Environmental Health System (EHS) on International Space Station (ISS) includes portable instruments to measure various cabin gases that acutely impact crew health. These hand-held devices measure oxygen, carbon dioxide, carbon monoxide, hydrogen chloride and hydrogen cyanide. The oxygen and carbon dioxide units also serve to back up key functions of the Major Constituent Analyzers. Wherever possible, commercial off-the-shelf (COTS) devices are employed by EHS to save development and sustaining costs. COTS hardware designed for general terrestrial applications however has limitations such as no pressure compensation, limited life of the active sensor, calibration drift, battery issues, unpredictable vendor support and obsolescence. The EHS fleet (inflight and ground inventory) of instruments is both aging and dwindling in number. With the retirement of the US Space Shuttle, maintenance of on-orbit equipment becomes all the more difficult. A project is underway to search for gas monitoring technology that is highly reliable and stable for years. Tunable Diode Laser Spectroscopy (TDLS) seems to be the front-runner technology, but generally is not yet commercially available in portable form. NASA has fostered the development of TDLS through the Small Business Innovative Research (SBIR) program. A number of gases of interest to the aerospace and submarine communities can be addressed by TDLS including the list mentioned above plus hydrogen fluoride, ammonia and water (humidity). There are several different forms of TDLS including photoacoustic and direct absorption spectroscopy using various multipass cell geometries. This paper describes the history of portable gas monitoring on NASA spacecraft and provides a status of the development of TDLS based instruments. Planned TDLS flight experiments on ISS could lead both to operational use on ISS and important roles in future Exploration spacecraft and habitats.

Mudgett, Paul D.↗

Modeling for Battery Prognostics

For any battery-powered vehicles (be it unmanned aerial vehicles, small passenger aircraft, or assets in exoplanetary operations) to operate at maximum efficiency and reliability, it is critical to monitor battery health as well performance and to predict end of discharge (EOD) and end of useful life (EOL). To fulfil these needs, it is important to capture the battery's inherent characteristics as well as operational knowledge in the form of models that can be used by monitoring, diagnostic, and prognostic algorithms. Several battery modeling methodologies have been developed in last few years as the understanding of underlying electrochemical mechanics has been advancing. The models can generally be classified as empirical models, electrochemical engineering models, multi-physics models, and molecular/atomist. Empirical models are based on fitting certain functions to past experimental data, without making use of any physicochemical principles. Electrical circuit equivalent models are an example of such empirical models. Electrochemical engineering models are typically continuum models that include electrochemical kinetics and transport phenomena. Each model has its advantages and disadvantages. The former type of model has the advantage of being computationally efficient, but has limited accuracy and robustness, due to the approximations used in developed model, and as a result of such approximations, cannot represent aging well. The latter type of model has the advantage of being very accurate, but is often computationally inefficient, having to solve complex sets of partial differential equations, and thus not suited well for online prognostic applications. In addition both multi-physics and atomist models are computationally expensive hence are even less suited to online application An electrochemistry-based model of Li-ion batteries has been developed, that captures crucial electrochemical processes, captures effects of aging, is computationally efficient, and is of suitable accuracy for reliable EOD prediction in a variety of operational profiles. The model can be considered an electrochemical engineering model, but unlike most such models found in the literature, certain approximations are done that allow to retain computational efficiency for online implementation of the model. Although the focus here is on Li-ion batteries, the model is quite general and can be applied to different chemistries through a change of model parameter values. Progress on model development, providing model validation results and EOD prediction results is being presented.

Prognostics↗