Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “barriers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Overcoming Barriers to Radiopharmaceutical Therapy (RPT): An Overview From the NRG-NCI Working Group on Dosimetry of Radiopharmaceutical Therapy

Radiopharmaceutical therapy (RPT) continues to demonstrate tremendous potential in improving the therapeutic gains in radiation therapy by specifically delivering radiation to tumors that can be well assessed in terms of dosimetry and imaging. Dosimetry in external beam radiation therapy is standard practice. This is not the case, however, in RPT. This NRG (acronym formed from the first letter of the 3 original groups: National Surgical Adjuvant Breast and Bowel Project, the Radiation Therapy Oncology Group, and the Gynecologic Oncology Group)-National Cancer Institute Working Group review describes some of the challenges to improving RPT. The main priorities for advancing the field include (1) developing and adopting best practice guidelines for incorporating patient-specific dosimetry for RPT that can be used at both large clinics with substantial resources and more modest clinics that have limited resources, (2) establishing and improving strategies for introducing new radiopharmaceuticals for clinical investigation, (3) developing approaches to address the radiophobia that is associated with the administration of radioactivity for cancer therapy, and (4) solving the financial and logistical issues of expertise and training in the developing field of RPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A cost and community perspective on the barriers to microbiome data reuse

Microbiome research is becoming a mature field with a wealth of data amassed from diverse ecosystems, yet the ability to fully leverage multi-omics data for reuse remains challenging. To provide a view into researchers’ behavior and attitudes towards data reuse, we surveyed over 700 microbiome researchers to evaluate data sharing and reuse challenges. We found that many researchers are impeded by difficulties with metadata records, challenges with processing and bioinformatics, and problems with data repository submissions. We also explored the cost constraints of data reuse at each step of the data reuse process to better understand “pain points” and to provide a more quantitative perspective from sixteen active researchers. The bioinformatics and data processing step was estimated to be the most time consuming, which aligns with some of the most frequently reported challenges from the community survey. From these two approaches, we present evidence-based recommendations for how to address data sharing and reuse challenges with concrete actions for future work.

59 BASIC BIOLOGICAL SCIENCES↗

Zero-Valent Iron Permeable Reactive Barrier to Remediate Volatile Organic Compounds in Groundwater - 20209

The US DOE-SRS, the US EPA, and the South Carolina Department of Health and Environmental Control determined it was appropriate to perform a non-time critical removal action at the P-Area Groundwater Operable Unit at the SRS to reduce the mass and downgradient transport of trichloroethylene in the P-Area groundwater plume. Contaminated groundwater discharges to a nearby stream, Steel Creek, within the SRS boundaries, resulting in trichloroethylene concentrations above the maximum contaminant level. Impact to surface water is limited in areal extent and supported by recently collected characterization data. The P-Area Groundwater Operable Unit encompasses the groundwater beneath an industrial area within SRS, P Area, where the P-Reactor once operated. The boundaries of the P-Area Groundwater Operable Unit extend northwest to Steel Creek, northeast toward PAR Pond, and southeast to Meyers Branch. Groundwater in the Upper Three Runs Aquifer of the P-Area Groundwater Operable Unit has been impacted by reactor and facility operations between 1954 and 1991, including tritium and volatile organic compounds. The P-Area surface units contributing to groundwater contamination were remediated as part of the P-Area Operable Unit in 2011. The P-Reactor closure is one of the first of its kind in the DOE Complex and is one of only a few full-sized production reactors in the US to undergo completion of final closure activities. The nature and extent of groundwater contamination was determined using a variety of investigative approaches such as groundwater monitoring wells, direct-push technology, and surface water samples. Groundwater contamination associated with trichloroethylene is primarily exhibited in a narrow plume that extends from the source area at P-Reactor and west to Steel Creek. Maximum contaminant level exceedances in groundwater occur over an area of ∼6.9 hectares for trichloroethylene with concentrations as high as 7.7 milligrams per liter. To the west of the P-Area facility area, the trichloroethylene groundwater plume is controlled by a buried geologic feature, assumed to be an old stream bed, that further narrows the groundwater plume in what has been designated as the 'neck area.' This narrowing of the groundwater plume provides an ideal location for a treatment barrier. The non-time critical removal action alternative chosen is to install a zero-valent iron permeable reactive barrier within the neck area of the trichloroethylene groundwater plume, perpendicular to groundwater flow direction. This technology will provide a treatment barrier that will reduce trichloroethylene groundwater concentrations by 90% and has an anticipated useful life of at least 25 years. A pre-design investigation was performed in the neck area to confirm site lithology, hydrogeology, geochemistry, and extent of trichloroethylene contamination prior to a final design. A treatability study, conducted as part of the pre-design investigation, indicated that the subsurface and groundwater in the PArea Groundwater Operable Unit is compatible with the zero-valent iron and will not lead to excessive buildup from mineralization/precipitation or biofouling. Probabilistic modeling was conducted using field and laboratory data to determine the expected performance of the zero-valent iron permeable reactive barrier. The model simulations indicated that a 3.81-centimeter thick barrier would provide greater than 90% reduction of trichloroethylene groundwater concentration. The final design of the zero-valent iron permeable reactive barrier is a barrier that will extend 80.5 linear meters in a 'zigzag' orientation to best transect the trichloroethylene plume and account for varying groundwater flow. The barrier will be installed from 13.7 meters below ground surface to 41.1 meters below ground surface for 65.8 linear meters and from 13.7 meters below ground surface to 36.6 meters below ground surface for 14.6 linear meters, the base of which is 'keyed' into a low permeability zone. The barrier is designed to a thickness of 10.2 centimeters, which was determined to reduce the trichloroethylene groundwater concentrations by greater than 90% with a safety factor of 2.67. A total of approximately 689 metric tons of zero-valent iron will be injected through 22 injection wells spaced 3.66 meters apart, using guar to suspend the zero-valent iron. Zero-valent iron permeable reactive barrier construction will be monitored through 23 installed resistivity receivers offset 7.32 meters from the zerovalent iron permeable reactive barrier. The zero-valent iron will be energized with a low-voltage 100 Hertz signal during injection and will be monitored using the resistivity receivers to ensure complete coalescence of the zero-valent iron permeable reactive barrier. The zero-valent iron was sized to have a hydraulic conductivity greater than the natural subsurface, thus promoting groundwater flow through the barrier. As contaminated groundwater contacts the zero-valent iron, volatile organic compounds, including trichloroethylene, are immediately degraded to harmless compounds such as ethylene. The performance of the zero-valent iron permeable reactive barrier will be monitored using three upgradient monitoring well clusters, six downgradient monitoring well clusters, and four in-wall monitoring wells. The in-wall monitoring wells will indicate immediate reduction of trichloroethylene mass in the groundwater and allow analyses of the zero-valent iron permeable reactive barrier health. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Complementary Barrier Infrared Detector

The complementary barrier infrared detector (CBIRD) is designed to eliminate the major dark current sources in the superlattice infrared detector. The concept can also be applied to bulk semiconductor- based infrared detectors. CBIRD uses two different types of specially designed barriers: an electron barrier that blocks electrons but not holes, and a hole barrier that blocks holes but not electrons. The CBIRD structure consists of an n-contact, a hole barrier, an absorber, an electron barrier, and a p-contact. The barriers are placed at the contact-absorber junctions where, in a conventional p-i-n detector structure, there normally are depletion regions that produce generation-recombination (GR) dark currents due to Shockley-Read- Hall (SRH) processes. The wider-bandgap complementary barriers suppress G-R dark current. The barriers also block diffusion dark currents generated in the diffusion wings in the neutral regions. In addition, the wider gap barriers serve to reduce tunneling dark currents. In the case of a superlattice-based absorber, the superlattice itself can be designed to suppress dark currents due to Auger processes. At the same time, the barriers actually help to enhance the collection of photo-generated carriers by deflecting the photo-carriers that are diffusing in the wrong direction (i.e., away from collectors) and redirecting them toward the collecting contacts. The contact layers are made from materials with narrower bandgaps than the barriers. This allows good ohmic contacts to be made, resulting in lower contact resistances. Previously, THALES Research and Technology (France) demonstrated detectors with bulk InAsSb (specifically InAs0.91Sb0.09) absorber lattice-matched to GaSb substrates. The absorber is surrounded by two wider bandgap layers designed to minimize impedance to photocurrent flow. The wide bandgap materials also serve as contacts. The cutoff wavelength of the InAsSb absorber is fixed. CBIRD may be considered as a modified version of the THALES double heterostructure (DH) p-i-n device, but with even wider bandgap barriers inserted at the contact layer/absorber layer interfaces. It is designed to work with either bulk semiconductors or superlattices as the absorber material. The superlattice bandgap can be adjusted to match the desired absorption cutoff wavelength. This infrared detector has the potential of high-sensitivity operation at higher operating temperatures. This would reduce cooling requirements, thereby reducing the power, mass, and volume of the equipment and allowing an increased mission science return.

Ting, David Z.↗

Algebraic expressions for estimating the impact depths of a surface barrier over a homogeneous soil

Engineered surface barriers are used to isolate subsurface contaminants for effective long-term containment of municipal solid waste, other nonhazardous solid and liquid waste, hazardous and toxic wastes, and radioactive waste. The impact depths of a surface barrier are affected by the pre-barrier recharge rate and the properties of the soil beneath the barrier. In this paper, the pore-size-specific (PSS) water velocity is defined and an algebraic expression of PSS velocity is derived based on the stream tube concept and the Brooks and Corey hydraulic retention model. Algebraic expressions are developed to estimate drainage velocities and barrier impact depths after the emplacement of a surface barrier. Four impact depth terms are used to convey the protective effect: drainage front, average drainage, the location with 50% impact, and drainage tail. The drainage front depth is the deepest point at which the barrier has a detectable impact at a specific time (also called the near zero-impact depth). The average-impact depth is the depth at which average drainage occurs. At the 50% impact depth, the water flux rate is reduced by half because of the surface barrier. Lastly, the drainage tail depth (also called the full-impact depth) is the deepest depth at which the water conditions above it are in equilibrium with the barrier. The algebraic expressions show that the average-impact depth is no more than 1/3 of near zero-impact depth, while the 50% impact depth is slightly larger than 1/2 of the near zero-impact depth. The full-impact depth, depending on the final recharge rate from the surface barrier, is usually much smaller than the other impact depths. These differences lead to a very large transition zone beneath a surface barrier. Numerical simulations were conducted to replicate the same conditions. The numerical results corroborated the analytical models by predicting very similar water content profiles and near zero-, average-, 50%, and full-impact depths. The algebraic expressions provided in this paper are useful for quickly identifying sites where the depth of the existing contaminants could be beyond the protection of a surface barrier.

54 ENVIRONMENTAL SCIENCES↗

Prototype Hanford Barrier Performance Monitoring Report: Fiscal Year 2024

This report provides an annual update on performance monitoring of the Prototype Hanford Barrier (PHB) at the Hanford Site. The PHB is part of a long-term study that serves as the scientific basis for many of the evapotranspiration-capillary barrier designs currently used globally and for future engineered barrier designs planned for remedial actions over waste and demolition sites at the Hanford Site. The PHB allows us to identify potential future issues and develop better monitoring techniques before these engineered barriers are constructed. Surface barriers like the PHB are essential for preventing water infiltration and curbing the spread of contaminants to groundwater. Effective monitoring of soil moisture levels above and below these barriers is crucial given that performance metrics could span up to 1,000 years. From July 2023 to June 2024, the water flux (as measured by tipping buckets) through the 2-m-thick silt loam layer of the PHB – a fine silty material that stores water under high capillary tension – remained well below the 0.5-mm-per-year performance threshold, demonstrating its effectiveness in preventing water penetration. In 2024, degraded tipping bucket gauges were replaced to ensure the accuracy of future data. Additionally, neutron probes revealed that the wetting front from the rainy season only penetrated to a maximum depth of 1.2 m into the silt loam. This further demonstrated the barrier's efficiency, as the wetting front did not fully penetrate the 2-m-thick capillary barrier. The western gravel slope of the PHB, composed of Hanford Site pit gravel of varying sizes, demonstrated low flux rates. In contrast, the eastern riprap slope exhibited higher flux rates. Zhang (2017) found that the riprap side slope of the PHB had the highest drainage rates in January and the lowest in late summer or early fall, indicating significant summer evaporation. Drainage rates increased significantly under enhanced precipitation conditions, far exceeding the design criterion, which could lead to water infiltration into the waste zone. The study introduced the “edge effect,” where elevated drainage rates from the riprap may migrate laterally beneath the barrier, compromising its ability to isolate waste, and recommended expanding the barrier and conducting further research to mitigate this issue. This report provides a review on surface barrier edge effects and their potential impact to subsurface contaminant migration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of an Opaque Reflecting Layer on the Thermal Behavior of a Thermal Barrier Coating

A parametric study using a two-flux approximation of the radiative transfer equation was performed to examine the effects of an opaque reflective layer on the thermal behavior of a typical semitransparent thermal barrier coating on an opaque substrate. Some ceramic materials are semitransparent in the wavelength ranges where thermal radiation is important. Even with an opaque layer on each side of the semitransparent thermal barrier coating, scattering and absorption can have an effect on the heat transfer. In this work, a thermal barrier coating that is semitransparent up to a wavelength of 5 micrometers is considered. Above 5 micrometers wavelength, the thermal barrier coating is opaque. The absorption and scattering coefficient of the thermal barrier was varied. The thermal behavior of the thermal barrier coating with an opaque reflective layer is compared to a thermal barrier coating without the reflective layer. For a thicker thermal barrier coating with lower convective loading, which would be typical of a combustor liner, a reflective layer can significantly decrease the temperature in the thermal barrier coating and substrate if the scattering is weak or moderate and for strong scattering if the absorption is large. The layer without the reflective coating can be about as effective as the layer with the reflective coating if the absorption is small and the scattering strong. For low absorption, some temperatures in the thermal barrier coating system can be slightly higher with the reflective layer. For a thin thermal barrier coating with high convective loading, which would be typical of a blade or vane that sees the hot sections of the combustor, the reflective layer is not as effective. The reflective layer reduces the surface temperature of the reflective layer for all conditions considered. For weak and moderate scattering, the temperature of the TBC-substrate interface is reduced but for strong scattering, the temperature of the substrate is increased slightly.

Spuckler, Charles M.↗

Depth-Penetrating Luminescence Thermography of Thermal- Barrier Coatings

A thermographic method has been developed for measuring temperatures at predetermined depths within dielectric material layers . especially thermal-barrier coatings. This method will help satisfy a need for noncontact measurement of through-the-thickness temperature gradients for evaluating the effectiveness of thermal- barrier coatings designed to prevent overheating of turbine blades, combustor liners, and other engine parts. Heretofore, thermography has been limited to measurement of surface and near-surface temperatures. In the thermographic method that is the immediate predecessor of the present method, a thermographic phosphor is applied to the outer surface of a thermal barrier coating, luminescence in the phosphor is excited by illuminating the phosphor at a suitable wavelength, and either the time dependence of the intensity of luminescence or the intensities of luminescence spectral lines is measured. Then an emissivity-independent surface-temperature value is computed by use of either the known temperature dependence of the luminescence decay time or the known temperature dependence of ratios between intensities of selected luminescence spectral lines. Until now, depth-penetrating measurements have not been possible because light of the wavelengths needed to excite phosphors could not penetrate thermal-barrier coating materials to useful depths. In the present method as in the method described above, one exploits the temperature dependence of luminescence decay time. In this case, the phosphor is incorporated into the thermal-barrier coat at the depth at which temperature is to be measured. To be suitable for use in this method, a phosphor must (1) exhibit a temperature dependence of luminescence decay time in the desired range, (2) be thermochemically compatible with the thermal-barrier coating, and (3) exhibit at least a minor excitation spectral peak and an emission spectral peak, both peaks being at wavelengths at which the thermal-barrier coating is transparent or at least translucent. Conventional thermographic phosphors are not suitable because they are most efficiently excited by ultraviolet light, which does not penetrate thermal- barrier coating materials. (Typical thermal-barrier coating materials include or consist of various formulations of yttria-stabilized zirconia.) Only a small fraction of phosphor candidates have significant excitation at wavelengths long enough (>500 nm) for sufficient penetration of thermal-barrier coatings. One suitable phosphor material . yttria doped with europium (Y2O3:Eu) . has a minor excitation peak at 532 nm and an emission peak at 611 nm. In experiments, this material was incorporated beneath a 100-microns-thick thermal-barrier coating and subjected to excitation and measurement by the luminescence-decay-time technique. These experiments were found to yield reliable temperature values up to 1,100 C. At the time of reporting the information for this article, a search for suitable phosphors other than (Y2O3:Eu) was continuing.

Eldridge, Jeffrey↗

Research to Develop Flood Barrier Testing Strategies for Nuclear Power Plants

The U.S. Nuclear Regulatory Commission has developed regulations regarding the siting and design of nuclear power plants (NPPs) that are aimed at addressing various natural hazards, including flooding. Flood barriers are designed to prevent water from entering NPP areas containing structures, systems, and components (SSCs) important to safety. The barriers are used at NPPs along with drains, sumps, pumps, valves, plugs, and site grading as part of the plant flood protection features that protect SSCs from experiencing external or internal flooding and mitigate the effects of flooding on NPP operations. The performance of flood protection features, including flood barriers at NPPs, has been an ongoing concern. Domestic and international operational experience provides clear indications that flood barrier performance has significant safety implications, especially for aging NPPs. The observed deficiencies show that flood barriers should be designed and installed properly, then adequately tested, inspected, and maintained in order to ensure that they perform their intended functions during flooding events. Here, this paper reviews available information related to flood barriers employed at U.S. NPPs and provides an overview and categorization of NPP flood barriers. It identifies potential domestic and international flood barrier testing facilities, including operating and decommissioned U.S. NPPs. Finally, this paper presents the technical and logistical considerations that should be made when developing specific testing strategies and protocols for flood barriers, such as the selection of flood barriers, test locations, testing approach, performance criteria, and testing parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analytic model of electron transport through and over non-linear barriers

Tunneling barriers are an essential component of electron sources, sensors, detectors, and vacuum nanoelectronics, and a pivotal factor in their performance, but the barriers themselves routinely depart from the analytic models used to model their behavior. Here, a new formalism is developed to analytically and accurately model emission through and over barriers associated with depletion layers, nanotip barriers, and MIM structures. The transmission probability for depletion layer and metal-insulator-metal (MIM) and metaloxide-semiconductor (MOS) barriers is accurately modeled as the electron energy exceeds the barrier height using approaches designed for rapid implementation demanded by simulation codes, and extensible to general barriers. The models supersede conventional thermal and field models in depletion and MIM/MOS barrier studies. Thermal-field methods are used to treat the transmission probability, and shape factor methods to treat the tunneling factor. Analytic formulae for current density are obtained. The methods ease device simulation and characterization of current-voltage relations for emerging technologically interesting barriers with better accuracy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of supplementary cementitious materials on the degradation of cement-based barriers in radioactive waste repository: A case study in Korea

This study focuses on investigating the chemical degradation characteristics of cementitious barriers used in low- and intermediate-level radioactive waste repository by reactive transport modeling. The impact of the blending with supplementary cementitious materials (SCMs) in the barriers on the chemical degradation was evaluated to find the optimum barrier design. A number of different barrier designs were examined by replacing ordinary Portland cement (OPC) by SCMs (i.e., fly ash, silica fume, and blast-furnace slag). The simulation results showed that silica fume blended barrier has better durability against chemical degradation by rainwater compared to fly ash or blast-furnace slag blended barriers. In addition, the chemical durability of silica fume-based barrier increased with increasing replacement level up to about 20 %. It seems that the amount of formed calcium silicate hydrate (CSH) in the initial cement-based barrier highly affects the overall chemical durability. The newly developed reactive transport model demonstrated its capability for understanding the barrier performance and investigating the optimal design of the barrier system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗