Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “balance calibration analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Analysis and Evaluation of NASA's MK40B Six-Component Task Balance

The MK40B balance is NASA's newest balance of Task design. Its load range was optimized for use in the NASA Ames 11-ft Transonic Wind Tunnel. The balance was calibrated in 2019 in Calspan's Automatic Balance Calibration System. The data analysis was performed at the Ames Balance Calibration Laboratory. First, bi-directional characteristics of the six gage outputs of the balance were assessed by applying a semi-empirical test to the calibration data. These tests indicated that four of the six gages have bi-directional characteristics. Therefore, the use of absolute value terms in the regression models of the calibration data is justified. Then, the machine calibration data was analyzed using both the Non-Iterative and the Iterative Method. Analysis results for the two methods were compared using the percent contributions, the calibration load residuals, the primary sensitivities, and the principle linear terms. These results confirmed that the two methods describe bi-directional characteristics of the balance gages correctly. In addition, it was concluded that the load prediction accuracies of the two methods are the same for all practical purposes.

wind tunnel balance↗

Development of a Non-Iterative Balance Load Prediction Algorithm for the NASA Ames Unitary Plan Wind Tunnel

A non-iterative load prediction algorithm for strain-gage balances was developed for the NASA Ames Unitary Plan Wind Tunnels that computes balance loads from the electrical outputs of the balance bridges and a set of state variables. A state variable could be, for example, a balance temperature difference or the bellows pressure of a flow-through balance. The algorithm directly uses regression models of the balance loads for the load prediction that were obtained by applying global regression analysis to balance calibration data. This choice greatly simplifies both implementation and use of the load prediction process for complex balance configurations as no load iteration needs to be performed. The regression model of a balance load is constructed by using terms from a total of nine term groups. Four term groups are derived from a Taylor Series expansion of the relationship between the load, gage outputs, and state variables. The remaining five term groups are defined by using absolute values of the gage outputs and state variables. Terms from these groups should only be included in the regression model if calibration data from a balance with known bi-directional outputs is analyzed. It is illustrated in detail how global regression analysis may be applied to obtain the coefficients of the chosen regression model of a load component assuming that no linear or massive near-linear dependencies between the regression model terms exist. Data from the machine calibration of a six-component force balance is used to illustrate both application and accuracy of the non-iterative load prediction process.

Ulbrich, Norbert M.↗

Detection of Unexpected High Correlations between Balance Calibration Loads and Load Residuals

An algorithm was developed for the assessment of strain-gage balance calibration data that makes it possible to systematically investigate potential sources of unexpected high correlations between calibration load residuals and applied calibration loads. The algorithm investigates correlations on a load series by load series basis. The linear correlation coefficient is used to quantify the correlations. It is computed for all possible pairs of calibration load residuals and applied calibration loads that can be constructed for the given balance calibration data set. An unexpected high correlation between a load residual and a load is detected if three conditions are met: (i) the absolute value of the correlation coefficient of a residual/load pair exceeds 0.95; (ii) the maximum of the absolute values of the residuals of a load series exceeds 0.25 % of the load capacity; (iii) the load component of the load series is intentionally applied. Data from a baseline calibration of a six-component force balance is used to illustrate the application of the detection algorithm to a real-world data set. This analysis also showed that the detection algorithm can identify load alignment errors as long as repeat load series are contained in the balance calibration data set that do not suffer from load alignment problems.

strain-gage balance↗

Influence of Primary Gage Sensitivities on the Convergence of Balance Load Iterations

The connection between the convergence of wind tunnel balance load iterations and the existence of the primary gage sensitivities of a balance is discussed. First, basic elements of two load iteration equations that the iterative method uses in combination with results of a calibration data analysis for the prediction of balance loads are reviewed. Then, the connection between the primary gage sensitivities, the load format, the gage output format, and the convergence characteristics of the load iteration equation choices is investigated. A new criterion is also introduced that may be used to objectively determine if the primary gage sensitivity of a balance gage exists. Then, it is shown that both load iteration equations will converge as long as a suitable regression model is used for the analysis of the balance calibration data, the combined influence of non linear terms of the regression model is very small, and the primary gage sensitivities of all balance gages exist. The last requirement is fulfilled, e.g., if force balance calibration data is analyzed in force balance format. Finally, it is demonstrated that only one of the two load iteration equation choices, i.e., the iteration equation used by the primary load iteration method, converges if one or more primary gage sensitivities are missing. This situation may occur, e.g., if force balance calibration data is analyzed in direct read format using the original gage outputs. Data from the calibration of a six component force balance is used to illustrate the connection between the convergence of the load iteration equation choices and the existence of the primary gage sensitivities.

Ulbrich, Norbert Manfred↗

Analysis and Evaluation of NASA's MK40B Six-Component TASK Balance

The paper discusses the physical characteristics NASA's MK40B TASK balance. It is NASA's newest TASK balance that was optimized for the testing of wind tunnel models in the NASA Ames 11-ft Transonic Wind Tunnel. The calibration data of the MK40B balance was obtained in Calspan's Automatic Balance Calibration System. A machine load schedule design was used for the calibration that was developed at the NASA Ames Balance Calibration Laboratory. The calibration data was analyzed using both the Non-Iterative Method and the Iterative Method. Then, the chosen regression models of the calibration data were assessed and compared using the percent contribution, the variance inflation factor, and the calibration load residuals. Interactions of single-component loads were also quantified. In addition, the bi-directional characteristics of the six gage outputs of the balance were assessed by applying a semi-empirical test that was developed at the Ames Balance Calibration Laboratory. It was concluded that four of the six gages of the balance have bi-directional characteristics. Finally, the accuracy of the load prediction equations of the balance was tested by applying the equations to independent check load data that was obtained at the NASA Ames Balance Calibration Laboratory. The standard deviation of the check load residuals met expectations. The check load data also confirmed that the interactions of the forward and aft normal forces on the axial force gage output are very small. - This paper is to be presented in the invited special session titled: "65 Years of TASK Wind Tunnel Balances - Past, Present, and Future".

wind tunnel balance↗

Analysis of uncertainty in force balance calibration

In order to reduce errors encountered in the measurement and identification of loads using force balances, a third-order forward polynomial relation between loads and output voltages is proposed. This full third-order model represents an alternative to the second-order model currently in use at NASA Langley Research Center (LaRC) and many other installations worldwide. The new model requires the identification of 84 coefficients (including the 28 used presently) for each of the six outputs. The existing LaRC calibration loading sequence is insufficient for identification of many of these 504 coefficients because critical three-load combinations are absent. Accordingly, a new loading sequence that permits the identification of all 504 coefficients has been developed and is described fully. It is apparent from numerical tests that the new third-order model is clearly superior to second-order models in the presence of small amounts of random measurement noise, assuming that there are indeed higher-order interactions between loads. As the amount of noise increases, however, a third-order model becomes less attractive due to its ability to match the noise itself more faithfully than a second-order model. Numerical results suggest that the transition occurs when the magnitude of random noise becomes of the same order as that of the physical higher-order interactions.

Bursal, Faruk H.↗

Comparative Analysis of Two Cryogenic Force Balance Calibration Systems

Cryogenic wind-tunnel facilities face unique challenges in the calibration and operation of various measurement systems and instrumentation. Instruments that are subjected to the cryogenic conditions of the test plenum require careful design and calibration procedures to maintain instrument performance. NASA’s National Transonic Facility (NTF) and the European Transonic Windtunnel (ETW) are two cryogenic wind-tunnel facilities, each with the ability to calibrate force measurement systems (FMS) at cryogenic conditions. These facilities have different methodologies and processes for calibrating these systems. This paper discusses differences in the methodologies and processes and compares the results of two separate cryogenic calibrations of the NTF-118A force balance that were completed at both wind-tunnel facilities.

Toro, Kenneth G.↗

Calibration and Data Analysis Recommendations for Three-Component Moment Balances

Fundamental characteristics of design, calibration, and application of three-component moment balances are investigated in great detail. These balances are typically used to determine loads on control surfaces, canards, or other parts that are attached to a wind tunnel model. First, three different descriptions of the load state of a moment balance are reviewed. Then, load transformations between different load formats and the combined load diagram for two of the three load components are discussed. An error analysis showed that it is critical to maximize the product of the distance between the bending moment gages and their sensitivities in order to minimize the overall error in the normal force prediction. In addition, it is important to apply a sufficient number of calibration loadings near the first bending moment gage. Then, unwanted near-linear dependencies between the two bending moment gage outputs can be avoided. The error in the bending moment prediction is also investigated that results from the elastic deformation of the metric part of the balance under load. Finally, the application of the Non-Iterative Method to three-component moment balance calibration data is described in order to obtain regression models that can be used to predict loads from measured outputs during a wind tunnel test.

Strain-Gage Balance↗

Evaluation of a Traditional Regression Model Term Selection Process for Balance Calibration Data Sets

Key elements of a traditional regression model term selection process for the analysis of wind tunnel strain-gage balance calibration data are discussed. The traditional process is sometimes applied when regression models of the gage outputs are needed and an analyst does not have access to a term selection algorithm. In principle, the traditional process identifies supported regression model terms of a gage output by combining an analyst's subject- matter knowledge with a visual examination of selected plots of the calibration loads. Twelve empirical rules are listed that may be used to select regression model terms. Data from the manual calibration of a force balance is used to illustrate the application of the traditional term selection process. The data example shows that the traditional process can become very complex. Its successful application highly depends on an analyst's experience and skills. Therefore, it is suggested to replace the traditional term selection process with an automated term selection algorithm. Then, objective metrics are systematically applied during the term selection that make the identification of the regression model more repeatable and less dependent on an analyst's personal skills.

strain-gage balance↗

Preliminary Statistical Analysis of the 1995 Evaluation by NASA LaRC of the IAI Automatic Balance Calibration Machine

The NASA Langley Research Center (LARC) participated in a national cooperative evaluation of the Israel Aircraft Industries (IAI) automatic balance calibration machine at Microcraft, San Diego in September 1995. A LaRC-designed six-component strain gauge balance was selected for test and calibration during LaRC's scheduled evaluation period. Eight calibrations were conducted using three selected experimental designs. Raw data were exported to LaRC facilities for reduction and statistical analysis using the techniques outlined in Tripp and Tcheng (1994). This report presents preliminary assessments of the results, and compares IAI calibration results with manual calibration results obtained at the Modern Machine and Tool Co., Inc. (MM & T). Newport News, VA. A more comprehensive report is forthcoming.

Tcheng, Ping↗

The Use of Absolute-Value Terms in Regression Modeling of Multi-Piece Force Balances

Different aspects of the use of absolute-value terms in regression models of the electrical outputs of multi-piece force balance calibration data are discussed. First, characteristics of a variety of regression model term combinations with absolute-value terms are reviewed that are currently used in the aerospace testing community to fit the gage outputs of a balance. Then, a semi-empirical test is presented that quantifies bidirectional characteristics of the balance bridge outputs. Several diagnostic methods are discussed to assess the severity of near-linear dependencies between regressors of models with absolute-value terms. In particular, connections between the linear, absolute-value, quadratic, signed quadratic, and cubic terms are studied in greater detail. Data from an automated calibration of NASAs MK29B force balance are used to illustrate the most important observations and results. Rules of thumb that variance-inflation factors be less than 10 must be relaxed when using absolute-value terms to describe bidirectional balances.

calibration analysis↗

Numerical analysis of the first static calibration of the RSRA helicopter active-isolator rotor balance system

The helicopter version of the Rotor Systems Research Aircraft (RSRA) is designed to make simultaneous measurements of all rotor forces and moments in a manner analogous to a wind-tunnel balance. Loads are measured by a combination of load cells, strain gages, and hydropneumatic active isolators with built-in pressure gages. Complete evaluation of system performance requires calibration of the rotor force- and moment-measurement system when installed in the aircraft. Derivations of calibration corrections for various combinations of calibration data are discussed.

Acree, C. W., Jr.↗

Load Schedule Design Improvements for the Calibration of NASA's Semi-span Balances

Improvements of the load schedule design for the calibration of NASA's semi-span balances are discussed. These improvements became possible after a minor hardware change was made to Calspan's Large Load Rig. This change moves normal and axial force load points 12 inches closer to the balance moment center. Resulting data quality improvements are significant because Calspan's Large Load Rig cannot currently apply forces at the balance moment center of a semi-span balance. Now, the supported set of rolling and yawing moment arms is 28 inches, 38 inches, and 48 inches. Consequently, the new load schedule design better supports expected normal and axial force locations on semi-span models that are tested in the NASA Ames 11-ft Transonic Wind Tunnel. In addition, estimates of the primary sensitivities of the normal force, axial force, rolling moment, and yawing moment have become more accurate as the applied normal and axial forces have moved closer to the balance moment center. Fundamental moment arm range requirements and Calspan's hardware updates are discussed in detail. In addition, calibration analysis results of NASA's ARC30K semi-span balance are presented to illustrate benefits of the hardware changes.

wind tunnel test↗

Evaluation of Regression Models of Balance Calibration Data Using an Empirical Criterion

An empirical criterion for assessing the significance of individual terms of regression models of wind tunnel strain gage balance outputs is evaluated. The criterion is based on the percent contribution of a regression model term. It considers a term to be significant if its percent contribution exceeds the empirical threshold of 0.05%. The criterion has the advantage that it can easily be computed using the regression coefficients of the gage outputs and the load capacities of the balance. First, a definition of the empirical criterion is provided. Then, it is compared with an alternate statistical criterion that is widely used in regression analysis. Finally, calibration data sets from a variety of balances are used to illustrate the connection between the empirical and the statistical criterion. A review of these results indicated that the empirical criterion seems to be suitable for a crude assessment of the significance of a regression model term as the boundary between a significant and an insignificant term cannot be defined very well. Therefore, regression model term reduction should only be performed by using the more universally applicable statistical criterion.

Ulbrich, Norbert↗

Graphical and Numerical Description of Strain-Gage Balance Interactions

A new approach for the graphical and numerical description of balance interactions is presented. The approach uses data from single-component loads as input. This choice has the two advantages. First, the number of applied loads is at the minimum needed for interactions to be observed. In addition, the loads used for the description of interactions can easily be repeated at different sites. Output differences relative to the outputs of the zero load point of a load series are used for the description of interactions. Similarly, load differences relative to the loads of the zero load point of a load series are used for the description of the loads. Interactions are plotted versus the load differences for each load component while omitting the outputs of the primary gage of the chosen load component. The resulting plots have a characteristic star pattern as interactions are zero at zero load. Numerical estimates of the slopes of the interactions can be reverse-engineered from the load prediction equations of a balance if calibration data is examined. The slopes are the off-diagonal coefficients of the inverse of the matrix that has the coefficients of the linear terms of the fitted loads if the Non-Iterative Method is used for the analysis. Similarly, the slopes are the off-diagonal coefficients of the inverse of the matrix that is the non-iterative part of the primary load iteration equation if the Iterative Method is used for the analysis. Data from the calibration of a force balance is processed to illustrate the proposed graphical and numerical description of interactions.

wind tunnel test↗

A Universal Threshold for the Assessment of Load and Output Residuals of Strain-Gage Balance Data

A new universal residual threshold for the detection of load and gage output residual outliers of wind tunnel strain{gage balance data was developed. The threshold works with both the Iterative and Non{Iterative Methods that are used in the aerospace testing community to analyze and process balance data. It also supports all known load and gage output formats that are traditionally used to describe balance data. The threshold's definition is based on an empirical electrical constant. First, the constant is used to construct a threshold for the assessment of gage output residuals. Then, the related threshold for the assessment of load residuals is obtained by multiplying the empirical electrical constant with the sum of the absolute values of all first partial derivatives of a given load component. The empirical constant equals 2.5 microV/V for the assessment of balance calibration or check load data residuals. A value of 0.5 microV/V is recommended for the evaluation of repeat point residuals because, by design, the calculation of these residuals removes errors that are associated with the regression analysis of the data itself. Data from a calibration of a six-component force balance is used to illustrate the application of the new threshold definitions to real{world balance calibration data.

wind tunnel balance↗

Load Schedule Design Improvements for the Calibration of NASA's Semi-span Balances

Improvements of the load schedule design for the calibration of NASA's semi-span balances are discussed. These improvements became possible after a minor hardware change was made to Calspan's Large Load Rig. This change moves normal and axial force load points 12 inches closer to the balance moment center. Resulting data quality improvements are significant because Calspan's Large Load Rig cannot currently apply forces at the balance moment center of a semi-span balance. Now, the supported set of rolling and yawing moment arms is 28, 38, and 48 inches. Consequently, the new load schedule design better supports expected normal and axial force locations on semi-span models that are tested in the NASA Ames 11-ft Transonic Wind Tunnel. In addition, estimates of the primary sensitivities of the normal force, axial force, rolling moment, and yawing moment have become more accurate as the applied normal and axial forces have moved closer to the balance moment center. Fundamental moment arm range requirements and Calspan's hardware updates are discussed. In addition, calibration and check load analysis results of NASA's ARC30K semi-span balance are presented to illustrate benefits of the hardware changes.

wind tunnel test↗

Design of a three-component wall-mounted balance

The design and evaluation of a three-component, wall-mounted pyramidal balance for a small wind tunnel is discussed. The balance was designed to measure lift, drag, pitching moment, and angle of attack. The specific design of each component and mathematical models used to design the balance are covered. Balance evaluation consisted of calibration, tare, and interaction analysis.

Winkelmann, Allen E.↗