Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “badge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Native Fluorescence Detection Methods, Devices, and Systems for Organic Compounds

Naphthalene, benzene, toluene, xylene, and other volatile organic compounds VOCs have been identified as serious health hazards. Embodiments of the invention are directed to methods and apparatus for near-real-time in-situ detection and accumulated dose measurement of exposure to naphthalene vapor and other hazardous gaseous VOCs. The methods and apparatus employ excitation of fluorophors native or endogenous to compounds of interest using light sources emitting in the ultraviolet below 300 nm and measurement of native fluorescence emissions in distinct wavebands above the excitation wavelength. The apparatus of some embodiments are cell-phone-sized sensor/dosimeter "badges" to be worn by personnel potentially exposed to hazardous VOCs. The badge sensor of some embodiments provides both real time detection and data logging of exposure to naphthalene or other VOCs of interest from which both instantaneous and accumulated dose can be determined.

Hug, William F.↗

Native Fluorescence Detection Methods, Devices, and Systems for Organic Compounds

Naphthalene, benzene, toluene, xylene, and other volatile organic compounds VOCs have been identified as serious health hazards. Embodiments of the invention are directed to methods and apparatus for near-real-time in-situ detection and accumulated dose measurement of exposure to naphthalene vapor and other hazardous gaseous VOCs. The methods and apparatus employ excitation of fluorophors native or endogenous to compounds of interest using light sources emitting in the ultraviolet below 300 nm and measurement of native fluorescence emissions in distinct wavebands above the excitation wavelength. The apparatus of some embodiments are cell-phone-sized sensor/dosimeter "badges" to be worn by personnel potentially exposed to hazardous VOCs. The badge sensor of some embodiments provides both real time detection and data logging of exposure to naphthalene or other VOCs of interest from which both instantaneous and accumulated dose can be determined.

Hug, William F.↗

Development of a Photoacoustic Formaldehyde Monitor

Key indoor air quality pollutant formaldehyde (H2CO) is tracked on International Space Station (ISS) using passive badges returned to the ground periodically for analysis. The process is time-consuming both in preparation and for analysis upon return 6-12 months later. Badges also require precious crew time for deploy, retrieval and stow. As NASA’s focus in space exploration shifts to the Moon and Mars, archival sample return becomes increasingly impractical, so the aim of this project is to develop a highly reliable real-time analyzer for H2CO at low concentrations with data downlinked. Potential sources of H2CO include materials off gassing, use of formalin as a tissue fixative in biological payloads and overheating of acetal polymers. The Spacecraft Maximum Allowable Concentration (SMAC) for H2CO is 100 ppb for exposures of 7 days or longer. ISS concentrations recently run only 10 - 30 ppb but have spiked as high as 60 ppb in the past. Gateway real time monitoring requirements call for a range of 8 - 140 ppb. For this project, a concentration range of 5 - 500 ppb H2CO is targeted. The core tunable diode laser spectroscopy (TDLS) technology was developed by Vista Photonics through the NASA and US Navy Small Business Innovation Research (SBIR) programs. Monitors based on this technology have been demonstrated on ISS, trialed on a nuclear submarine and are in production as Anomaly Gas Analyzers for both ISS and Orion. Initially, direct absorption TDLS was used exclusively in these monitors, however, the H2CO target concentration is much lower, and a longer wavelength required, so a photoacoustic spectroscopy (PAS) technique was adapted, where the laser excitation is detected by a sensitive microphone vs. a conventional photodetector. This paper will discuss the results of NASA-JSC laboratory testing of a prototype PAS based formaldehyde monitor and explore potential adaptations for Gateway missions and beyond.

Paul D Mudgett↗

Development of a Photoacoustic Formaldehyde Monitor

Key indoor air quality pollutant formaldehyde (H 2 CO) is tracked on International Space Station (ISS) using passive badges returned to the ground periodically for analysis. The process is time-consuming both in preparation and for analysis upon return 6-12 months later. Badges also require precious crew time for deploy, retrieval and stow. As NASA’s focus in space exploration shifts to the Moon and Mars, archival sample return becomes increasingly impractical, so the aim of this project is to develop a highly reliable real-time analyzer for H 2 CO at low concentrations with data downlinked. Potential sources of H 2 CO include materials off gassing, use of formalin as a tissue fixative in biological payloads and overheating of acetal polymers. The Spacecraft Maximum Allowable Concentration (SMAC) for H 2 CO in air is 100 ppb for exposures of 7 days or longer. ISS concentrations of H 2 CO are running only 10 - 30 ppb in the recent several years but have spiked as high as 60 ppb. Gateway real time monitoring requirements for H 2 CO call for a range of 8 - 138 ppb. For this project, a concentration range of 5 - 500 ppb H 2 CO is targeted. The core tunable diode laser spectroscopy (TDLS) technology used for this project was developed by Vista Photonics through the NASA and US Navy Small Business Innovation Research (SBIR) programs. Monitors based on TDLS have been demonstrated on ISS, trialed on a nuclear submarine and are being certified as portable Anomaly Gas Analyzers (AGA) for both ISS and Orion. Initially, direct absorption TDLS was used exclusively in these devices. The H 2 CO target concentration, however, is low ppb, and a longer wavelength is required, so a photoacoustic spectroscopy (PAS) technique was adapted, where the laser excitation is detected by a sensitive microphone vs. a conventional photodetector. This paper will discuss the results of NASA-JSC laboratory testing of a prototype PAS based formaldehyde in air monitor and briefly discuss next steps.

Photoacoustic Formaldehyde Monitor↗

Evolution of area access safety training required for gaining access to Space Shuttle launch and landing facilities

Assuring personnel and equipment are fully protected during the Space Shuttle launch and landing operations has been a primary concern of NASA and its associated contractors since the inception of the program. A key factor in support of this policy has been the area access safety training requirements for badging of employees assigned to work on Space Shuttle Launch and Facilities. This requirement was targeted for possible cost savings and the transition of physical on-site walkdowns to the use of television tapes has realized program cost savings while continuing to fully satisfy the area access safety training requirements.

Willams, M. C.↗

Length of stain dosimeter

Payload customers for the Space Shuttle have recently expressed concerns about the possibility of their payloads at an adjacent pad being contaminated by plume effluents from a shuttle at an active pad as they await launch on an inactive pad. As part of a study to satisfy such concerns a ring of inexpensive dosimeters was deployed around the active pad at the inter-pad distance. However, following a launch, dosimeters cannot be read for several hours after the exposure. As a consequence factors such as different substrates, solvent systems, and possible volatilization of HCl from the badges were studied. This observation led to the length of stain (LOS) dosimeters of this invention. Commercial passive LOS dosimeters are sensitive only to the extent of being capable of sensing 2 ppm to 20 ppm if the exposure is 8 hours. To map and quantitate the HCl generated by Shuttle launches, and in the atmosphere within a radius of 1.5 miles from the active pad, a sensitivity of 2 ppm HCl in the atmospheric gases on an exposure of 5 minutes is required. A passive length of stain dosimeter has been developed having a sensitivity rendering it capable of detecting a gas in a concentration as low as 2 ppm on an exposure of five minutes.

Lueck, Dale E.↗

Devices Would Detect Drugs In Sweat

Proposed devices worn on skin detect such substances as methamphetamine, morphine, tetrahydrocannabinol (THC), and cocaine in wearers' sweat and transmits radio signals in response to computer queries. Called Remote Biochemical Assay Telemetering System (R-BATS), commonly referred to as "drug badge," attached to wearer by use of adhesive wristband. Used for noninvasive monitoring of levels of prescribed medications in hospital and home-care settings and to detect overdoses quickly.

Mintz, Fredrick W.↗

High-Power Ion Thruster Technology

Performance data are presented for the NASA/Hughes 30-cm-diam 'common' thruster operated over the power range from 600 W to 4.6 kW. At the 4.6-kW power level, the thruster produces 172 mN of thrust at a specific impulse of just under 4000 s. Xenon pressure and temperature measurements are presented for a 6.4-mm-diam hollow cathode operated at emission currents ranging from 5 to 30 A and flow rates of 4 sccm and 8 sccm. Highly reproducible results show that the cathode temperature is a linear function of emission current, ranging from approx. 1000 C to 1150 C over this same current range. Laser-induced fluorescence (LIF) measurements obtained from a 30-cm-diam thruster are presented, suggesting that LIF could be a valuable diagnostic for real-time assessment of accelerator-arid erosion. Calibration results of laminar-thin-film (LTF) erosion badges with bulk molybdenum are presented for 300-eV xenon, krypton, and argon sputtering ions. Facility-pressure effects on the charge-exchange ion current collected by 8-cm-diam and 30-cm-diam thrusters operated on xenon propellant are presented to show that accel current is nearly independent of facility pressure at low pressures, but increases rapidly under high-background-pressure conditions.

Beattie, J. R.↗

Investigation of Chemically Treated Test-Strips for Ozone Measurement

A colorimetric passive ozone monitoring system is currently in use in the GLOBE project, as well as several other environmental studies, as commercially supplied as Eco-Badge by Vistanomics. This simple, but effective, system consists of papers treated with a chemical preparation, tin(II) diphenylcarbazidel that reacts with ozone to change them from white to purple. The intensity of the purple coloration is dependent on the concentration of ozone. Our previous contributions to that method of analysis involved modest modifications to the chemical substrate employed. The new formulation improved the reproducibility and linearity of the color change of treated papers.

Bush, Linda C.↗

X-Ray Imaging System

The Model 60007A InnerView Real-time X-ray Imaging System, produced by National Imaging Systems, a division of FlouroScan Imaging Systems, Inc. (formerly HealthMate, Inc.), Northbrook, IL, is a third generation spinoff from x-ray astronomy technology. Goddard Space Flight Center developed the original technology into the Lixiscope, a small, portable, minimal radiation x-ray instrument that could be used at the scene of an accident. FlouroScan Imaging Systems, Inc., adapted this technology to develop the FlouroScan, a low-intensity, x-ray system that could be used without the lead aprons, film badges and lead-lined walls that conventional systems require. The InnerView is a spinoff of non-destructive testing and product inspection.

Source record↗

Observation of Dust Stream Formation Produced by Low Current, High Voltage Cathode Spots

Macro-particle acceleration driven by low current, high voltage cathode spots has been investigated. The phenomenon was observed to occur when nanometer and micrometer-sized particles in the presence of a discharge plasma were exposed to a high voltage pulse. The negative voltage pulse initiates the formation of multiple, high voltage, low current cathode spots which provides the mechanism of actual acceleration of the charged dust particles. Dust streams generated by this process were detected using laser scattering techniques. The particle impact craters observed at the surface of downstream witness badges were documented using SEM and light microscopy.

Foster, John E.↗

Soyuz 7 Return Samples: Assessment of Air Quality Aboard the International Space Station

The toxicological assessments of one grab sample canister (GSC), 6 dual sorbent tubes (DSTs), and 20 formaldehyde badges returned aboard Soyuz 7 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSC were 84-89%. The recoveries of the less volatile surrogates from the DSTs were 87 to 112%; however, 13C-acetone was only recovered at 53-59%. Formaldehyde recoveries from 2 lab controls were 87 and 95%; trip controls were not returned to ground.

James, John T.↗

STS 117 Return Samples: Assessment of Air Quality aboard the Shuttle (STS-117) and International Space Station

The toxicological assessments of 2 grab sample canisters (GSCs) and one pair of formaldehyde badges from the Shuttle are reported. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the 2 GSCs averaged 109, 95, and 97%, respectively. Three formaldehyde controls averaged 93% recovery. The Shuttle atmosphere was acceptable for human respiration.

James, John T.↗

STS 120 Return Samples: Assessment of Air Quality Aboard the Shuttle (STS-120) and International Space Station (10A)

The toxicological assessments of 2 grab sample canisters (GSCs) from the Shuttle are reported. Formaldehyde badges were not used. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the 2 GSCs averaged 111, 82, and 78%, respectively. The Shuttle atmosphere was acceptable for human respiration.

James, John T.↗

STS 129 Return Samples: Assessment of Air Quality aboard the Shuttle (STS-129) and International Space Station (ULF3)

Reports on the air quality aboard the Space Shuttle (STS-129), and the International Space station (ULF3). NASA analyzed the grab sample canisters (GSCs) and the formaldehyde badges aboard both locations for carbon monoxide levels. The three surrogates: (sup 13)C-acetone, fluorobenzene, and chlorobenzene registered 109, 101, and 109% in the space shuttle and 81, 87, and 55% in the International Space Station (ISS). From these results the atmosphere in both the Space Shuttle and the International Space Station (ISS) was found to be breathable.

James, John T.↗

Assessment of Air Quality in the International Space Station (ISS) and Space Shuttle Based on Samples Returned Aboard STS-110 (ISS-8A) in April 2002

The toxicological assessment of grab sample canisters (GSCs) returned aboard STS-110 is reported. Analytical methods have not changed from earlier reports, and surrogate standard recoveries from the GSCs were 77-121%, with one exception. Pressure tracking indicated no leaks in the canisters. Recoveries from lab and trip controls for formaldehyde analyses ranged from 87 to 96%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). Because of the inertness of Freon 218 (octafluoropropane, OFP), its contribution to the NMVOC is subtracted and tabulated separately. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols are also shown for each sample. Because formaldehyde is quantified from sorbent badges, its concentration is listed separately. These five indices of air quality are summarized.

James, John T.↗

STS 132 Return Samples: Assessment of Air Quality Aboard the Shuttle (STS-132) and International Space Station (ULF4)

The toxicological assessments of 2 grab sample canisters (GSCs) from the Shuttle are reported. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (13C-acetone, fluorobenzene, and chlorobenzene) from the 2 Shuttle GSCs averaged 93, 85%, and 88%, respectively. Based on the end-of-mission sample, the Shuttle atmosphere was acceptable for human respiration. The toxicological assessment of 7 GSCs from the ISS is also shown. The recoveries of the 3 standards (as listed above) from the GSCs averaged 78, 96 and 90%, respectively. Recovery from formaldehyde control badges ranged from 90 to 112%.

James. John T.↗